Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz

CISPR 16-1-5:2014 specifies the requirements for calibration sites in the frequency range 5 MHz to 18 GHz used to perform antenna calibrations according to CISPR 16-1-6. It also specifies the requirements for reference test sites that are used for the validation of compliance test sites in the frequency range 30 MHz to 1 000 MHz according to CISPR 16-1-4. It has the status of a basic EMC standard in accordance with IEC Guide 107. Measurement instrumentation specifications are given in CISPR 16-1-1 and CISPR 16-1-4. Further information and background on uncertainties in general is given in CISPR 16-4, which can also be helpful in establishing uncertainty estimates for the calibration processes of antennas and site validation measurements. This second edition cancels and replaces the first edition published in 2003, and its Amendment 1 (2012). It constitutes a technical revision which includes the following significant technical changes with respect to the previous edition: - site validation methods for other sites covered in CISPR 16-1-6 are added; - smaller step sizes are specified for swept frequency measurements; - the minimum ground plane size is increased; - and other miscellaneous technical and editorial refinements are included.

Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 1-5: Geräte und Einrichtungen zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Messplätze für die Antennenkalibrierung und Referenz-Messplätze für den Frequenzbereich von 5 MHz bis 18 GHz

Spécification des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 1-5: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Emplacements d'étalonnage d'antenne et emplacements d'essai de référence pour la plage comprise entre 5 MHz et 18 GHz

Specifikacija za merilne naprave in metode za merjenje radijskih motenj in odpornosti - 1-5. del: Merilne naprave za merjenje radijskih motenj in odpornosti - Preskuševališča za kalibriranje anten in referenčna preskuševališča za 5 Mhz do 18 Mhz

Ta del standarda CISPR 16 določa zahteve za območja za umerjanje v frekvenčnem območju od 5 MHz do 18 GHz za umerjanje antene v skladu s standardom CISPR 16-1-6. Določa tudi zahteve za referenčna preskusna mesta (REFTS), ki se uporabljajo za preverjanje skladnosti preskusnih mest (COMTS) v frekvenčnem območju od 30 MHz do 1000 MHz v skladu s standardom CISPR 16-1-4.
Ima status osnovnega standarda o elektromagnetni združljivosti (EMC) v skladu z vodilom IEC Guide 107 Electromagnetic compatibility – Guide to the drafting of electromagnetic compatibility publications (Elektromagnetna združljivost – Vodilo za pripravo osnutkov publikacij o elektromagnetni združljivosti). Specifikacije za merilne instrumente so podane v standardih CISPR 16-1-1 [1]1 in CISPR 16-1- 4. Dodatne informacije o splošnih negotovostih so podane v standardu CISPR 16-4 [3], kar je lahko koristno pri ugotavljanju ocen negotovosti pri postopkih umerjanja anten in meritvah preverjanja mest.

General Information

Status
Published
Publication Date
05-Feb-2015
Withdrawal Date
20-Jan-2018
Current Stage
6060 - Document made available - Publishing
Start Date
06-Feb-2015
Completion Date
06-Feb-2015

Relations

Buy Standard

Standard
EN 55016-1-5:2015 - BARVE
English language
96 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2015
1DGRPHãþD
SIST EN 55016-1-5:2005
SIST EN 55016-1-5:2005/A1:2013
6SHFLILNDFLMD]DPHULOQHQDSUDYHLQPHWRGH]DPHUMHQMHUDGLMVNLKPRWHQMLQ
RGSRUQRVWLGHO0HULOQHQDSUDYH]DPHUMHQMHUDGLMVNLKPRWHQMLQRGSRUQRVWL
3UHVNXãHYDOLãþD]DNDOLEULUDQMHDQWHQLQUHIHUHQþQDSUHVNXãHYDOLãþD]D0K]GR
0K]
Specification for radio disturbance and immunity measuring apparatus and methods -
Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration
sites and reference test sites for 5 MHz to 18 GHz
Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur
Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil
1-5: Geräte und Einrichtungen zur Messung der hochfrequenten Störaussendung
(Funkstörungen) und Störfestigkeit - Messplätze für die Antennenkalibrierung und
Referenz-Messplätze für den Frequenzbereich von 5 MHz bis 18 GHz
Ta slovenski standard je istoveten z: EN 55016-1-5:2015
ICS:
17.220.20 0HUMHQMHHOHNWULþQLKLQ Measurement of electrical
PDJQHWQLKYHOLþLQ and magnetic quantities
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 55016-1-5

NORME EUROPÉENNE
EUROPÄISCHE NORM
February 2015
ICS 33.100.10; 33.100.20 Supersedes EN 55016-1-5:2004
English Version
Specification for radio disturbance and immunity measuring
apparatus and methods -
Part 1-5: Radio disturbance and immunity measuring apparatus -
Antenna calibration sites and reference
test sites for 5 MHz to 18 GHz
(CISPR 16-1-5:2014)
Spécification des méthodes et des appareils de mesure des Anforderungen an Geräte und Einrichtungen sowie
perturbations radioélectriques et de l'immunité aux Festlegung der Verfahren zur Messung der hochfrequenten
perturbations radioélectriques - Störaussendung (Funkstörungen) und Störfestigkeit -
Partie 1-5: Appareils de mesure des perturbations Teil 1-5: Geräte und Einrichtungen zur Messung der
radioélectriques et de l'immunité aux perturbations hochfrequenten Störaussendung (Funkstörungen) und
radioélectriques - Emplacements d'étalonnage d'antenne et Störfestigkeit - Messplätze für die Antennenkalibrierung und
emplacements d'essai de référence pour la plage comprise Referenz-Messplätze für den Frequenzbereich
entre 5 MHz et 18 GHz von 5 MHz bis 18 GHz
(CISPR 16-1-5:2014) (CISPR 16-1-5:2014)
This European Standard was approved by CENELEC on 2015-01-21. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 55016-1-5:2015 E
Foreword
The text of document CISPR/A/1086A/FDIS, future edition 2 of CISPR 16-1-5, prepared by
CISPR SC A “Radio-interference measurements and statistical methods" was submitted to the
IEC-CENELEC parallel vote and approved by CENELEC as EN 55016-1-5:2015.

The following dates are fixed:
(dop) 2015-10-21
• latest date by which the document has to be
implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2018-01-21
standards conflicting with the
document have to be withdrawn
This document supersedes EN 55016-1-5:2004.

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard CISPR 16-1-5:2014 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:

CISPR 16-1-1:2010 NOTE Harmonized as EN 55016-1-1:2010 (not modified).
CISPR 16-1-1:2010/A1:2010 NOTE Harmonized as EN 55016-1-1:2010/A1:2010 (not modified).
CISPR 16-2-3:2010 NOTE Harmonized as EN 55016-2-3:2010 (not modified).
CISPR 16-2-3:2010/A1:2010 NOTE Harmonized as EN 55016-2-3:2010/A1:2010 (not modified).
CISPR 16-4 Series NOTE Only Part 4-2 harmonized as EN 55016-4-2.

- 3 - EN 55016-1-5:2015
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu
Publication Year Title EN/HD Year

CISPR 16-1-4 2010 Specification for radio disturbance EN 55016-1-4 2010
and immunity measuring apparatus
+A1 2012 +A1 2012
and methods -
Part 1-4: Radio disturbance and immunity
measuring apparatus - Antennas and test
sites for radiated disturbance
measurements
CISPR 16-1-6 2014 Specification for radio disturbance EN 55016-1-6 2015
and immunity measuring apparatus
and methods -
Part 1-6: Radio disturbance
and immunity measuring apparatus -
EMC-antenna calibration
IEC 60050 Series International Electrotechnical Vocabulary - -

CISPR 16-1-5 ®
Edition 2.0 2014-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE

COMITÉ INTERNATIONAL SPÉCIAL DES PERTURBATIONS RADIOÉLECTRIQUES

BASIC EMC PUBLICATION
PUBLICATION FONDAMENTALE EN CEM

Specification for radio disturbance and immunity measuring apparatus and methods –

Part 1-5: Radio disturbance and immunity measuring apparatus – Antenna calibration

sites and reference test sites for 5 MHz to 18 GHz

Spécification des méthodes et des appareils de mesure des perturbations

radioélectriques et de l'immunité aux perturbations radioélectriques –

Partie 1-5: Appareils de mesure des perturbations radioélectriques et de l'immunité aux

perturbations radioélectriques – Emplacements d'étalonnage d'antenne et

emplacements d'essai de référence pour la plage comprise entre 5 MHz et 18 GHz

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX XD
ICS 33.100.10; 33.100.20 ISBN 978-2-8322-1932-4

– 2 – CISPR 16-1-5:2014  IEC 2014
CONTENTS
FOREWORD . 6
INTRODUCTION . 8
1 Scope . 10
2 Normative references . 10
3 Terms, definitions and abbreviations . 10
3.1 Terms and definitions . 10
3.1.1 Antenna terms . 11
3.1.2 Measurement site terms . 13
3.1.3 Other terms . 14
3.2 Abbreviations . 15
4 Specifications and validation procedures for CALTS and REFTS from 5 MHz to
1 000 MHz . 16
4.1 General . 16
4.2 Antenna calibration test site (CALTS) specification . 16
4.2.1 General . 16
4.2.2 Normative specification . 17
4.3 Test antenna specification . 17
4.3.1 General . 17
4.3.2 Details of the required characteristics of the test antenna . 18
4.4 Antenna calibration test site validation procedure . 20
4.4.1 General . 20
4.4.2 Test set-up . 20
4.4.3 Test frequencies and receive antenna heights . 22
4.4.4 SIL measurements . 22
4.4.5 Swept frequency SIL measurements . 25
4.4.6 Identifying and reducing reflections from antenna supports . 28
4.5 Antenna calibration test site acceptance criteria . 28
4.5.1 General . 28
4.5.2 Measurement uncertainties . 28
4.5.3 Acceptance criteria . 29
4.6 Calibration site with a metal ground plane for biconical antennas and tuned
dipole antennas over the frequency range 30 MHz to 300 MHz . 30
4.7 Validation of a REFTS . 31
4.7.1 General . 31
4.7.2 Validation for horizontal polarization . 31
4.7.3 Validation for vertical polarization . 31
4.8 Validation report for CALTS and REFTS . 33
4.8.1 General . 33
4.8.2 Validation report requirements . 33
4.9 Site validation for the calibration of biconical and dipole antennas, and the
biconical part of hybrid antennas in vertical polarization . 34
4.10 Validation of a CALTS using vertical polarization from 5 MHz to 30 MHz for
the calibration of monopole antennas . 35
4.10.1 General . 35
4.10.2 Uncertainty evaluation . 36
5 Validation methods for a FAR from 30 MHz to 18 GHz . 36
5.1 General . 36

CISPR 16-1-5:2014  IEC 2014 – 3 –
5.2 Validation procedure 1 GHz to 18 GHz . 37
5.2.1 Power transfer between two antennas . 37
5.2.2 Measurement procedure for validation from 1 GHz to 18 GHz . 37
5.2.3 Analysis of results .
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.