Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-22: Cables for general applications - High flexibility braided cables with crosslinked elastomeric insulation

EN 50525-2-22 applies to crosslinked EPR insulated and textile braided flexible cables. The cables are of rated voltage U0/U 300/300 V. The cables are intended for the connection of domestic appliances to the fixed supply, where an extra flexible connection is required. The maximum conductor operating temperature for the cables in this standard is 60 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-22 should be read in conjunction with EN 50525-1, which specifies general requirements.

Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) - Teil 2-22: Starkstromleitungen für allgemeine Anwendungen - Hochflexible umflochtene Leitungen mit vernetzter Elastomer-Isolierung

Câbles électriques - Câbles d’énergie basse tension de tension assignée au plus égale à 450/750 V (U0/U) - Partie 2-22: Câbles pour applications générales - Câbles sous tresse à flexibilité élevée isolés en matériau élastomère réticulé

Električni kabli - Nizkonapetostni energetski kabli z nazivno napetostjo do vključno 450/750 V (U0/U) - 2-22. del: Kabli za splošno uporabo - Pleteni kabli visoke stopnje zvijavosti z zamrežno elastomerno izolacijo

EN 50525-2-22 velja za zvijave kable z zamreženo elastomreno izolacijo, pletene iz tkanine. Ti kabli imajo nazivno napetost 300/300 V (UO/U). Kabli so namenjeni povezavi gospodinjskih aparatov s fiksnim napajanjem, kjer je potrebna dodatna fleksibilna povezava. Maksimalna delovna temperatura pretvornika za kable iz tega standarda je 60 °C.

General Information

Status
Published
Publication Date
05-May-2011
Withdrawal Date
16-Jan-2014
Technical Committee
CLC/TC 20 - Electric cables
Drafting Committee
CLC/TC 20 - Electric cables
Current Stage
9093 - Decision to confirm - Review Enquiry
Start Date
23-Oct-2024
Completion Date
20-Feb-2026

Relations

Effective Date
28-Jan-2023
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
03-Feb-2026

Overview

EN 50525-2-22:2011 is a European standard published by CENELEC (CLC), specifying the requirements for low voltage energy cables with rated voltages up to and including 450/750 V (U₀/U). Specifically, this standard addresses high flexibility braided cables with crosslinked elastomeric insulation, designed for general applications. The standard applies to flexible cables insulated with crosslinked ethylene propylene rubber (EPR) and covered by a textile braid. With a rated voltage of 300/300 V and a maximum conductor operating temperature of 60°C, these cables are primarily used to connect domestic appliances where extra flexibility is essential.

EN 50525-2-22 forms part of the broader EN 50525 series and should be used in conjunction with EN 50525-1, which outlines general cable requirements. It partially supersedes the older HD 22.14 S3:2007 standard.

Key Topics

  • Cable Construction: The cables covered feature class 6 flexible conductors, EPR insulation, textile fillers, and an external textile braid offering high flexibility and durability.
  • Rated Voltage: Intended for applications up to 300/300 V.
  • Insulation and Braid: EPR (ethylene propylene rubber) insulation provides resistance and reliability, while the textile braid increases flexibility and mechanical protection.
  • Testing and Compliance: Requirements include electrical tests, dimensional checks, textile braid coverage, insulation thickness, and mechanical strength tests (e.g., flexing and kink resistance).
  • Identification and Marking: Compliant cables are marked with the CENELEC code H03RT-H for easy identification.

Applications

EN 50525-2-22 cables are specially designed to meet the needs of situations where extra flexibility and mechanical protection are required, making them ideal for:

  • Domestic Appliances: Used to connect equipment such as vacuum cleaners, mixers, irons, and other handheld or movable household devices to the fixed supply.
  • Small Machinery and Portable Tools: Suitable for environments requiring frequent movement or regular handling.
  • General Indoor Use: Applicable wherever flexible, robust cables are necessary for linking appliances to the power supply.

Safety note: Extensive guidance on the safe use of these cables is provided in HD 516, which should be consulted to ensure correct installation and maintenance.

Related Standards

For a comprehensive understanding and proper application of EN 50525-2-22, the following standards are also relevant:

  • EN 50525-1: General requirements for low voltage energy cables of rated voltages up to and including 450/750 V (U₀/U).
  • EN 50363-1: Specifies crosslinked elastomeric insulating compounds for low voltage cables.
  • EN 50395: Details electrical test methods for low voltage energy cables.
  • EN 50396: Outlines non-electrical test methods such as dimensional and mechanical testing.
  • EN 60228: Specifies requirements for conductors of insulated cables.
  • HD 516: Provides guidance on the use of low voltage harmonized cables.
  • EN 60719 & EN 60811-2-1: Offer additional methods for dimensioning and special tests for elastomeric materials.

Practical Value

Adherence to EN 50525-2-22 ensures that flexible braided cables are robust, safe, and suitable for demanding domestic and light industrial conditions. By standardizing construction, marking, and testing, the document guarantees consistent performance, enhanced safety, and interoperability across the European market for low voltage flexible cables. This standard is essential for manufacturers, installers, and specifiers seeking compliance and optimal cable performance in applications requiring both flexibility and reliability.

Buy Documents

Standard

EN 50525-2-22:2011

English language (10 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

EN 50525-2-22:2011 is a standard published by CLC. Its full title is "Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-22: Cables for general applications - High flexibility braided cables with crosslinked elastomeric insulation". This standard covers: EN 50525-2-22 applies to crosslinked EPR insulated and textile braided flexible cables. The cables are of rated voltage U0/U 300/300 V. The cables are intended for the connection of domestic appliances to the fixed supply, where an extra flexible connection is required. The maximum conductor operating temperature for the cables in this standard is 60 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-22 should be read in conjunction with EN 50525-1, which specifies general requirements.

EN 50525-2-22 applies to crosslinked EPR insulated and textile braided flexible cables. The cables are of rated voltage U0/U 300/300 V. The cables are intended for the connection of domestic appliances to the fixed supply, where an extra flexible connection is required. The maximum conductor operating temperature for the cables in this standard is 60 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-22 should be read in conjunction with EN 50525-1, which specifies general requirements.

EN 50525-2-22:2011 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 50525-2-22:2011 has the following relationships with other standards: It is inter standard links to HD 22.14 S3:2007, EN 16282-3:2016, EN 16282-3:2016+A1:2021, EN 1648-1:2018, EN 16282-2:2016, EN 1648-2:2018, EN 60335-1:2012/A13:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 50525-2-22:2011 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU, 2014/53/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 50525-2-22:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-2011
(OHNWULþQLNDEOL1L]NRQDSHWRVWQLHQHUJHWVNLNDEOL]QD]LYQRQDSHWRVWMRGR
YNOMXþQR9 88 GHO.DEOL]DVSORãQRXSRUDER3OHWHQLNDEOL
YLVRNHVWRSQMH]YLMDYRVWL]]DPUHåQRHODVWRPHUQRL]RODFLMR
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750
V (U0/U) - Part 2-22: Cables for general applications - High flexibility braided cables with
crosslinked elastomeric insulation
Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) -
Teil 2-22: Starkstromleitungen für allgemeine Anwendungen - Hochflexible umflochtene
Leitungen mit vernetzter Elastomer-Isolierung
Câbles électriques - Câbles d’énergie basse tension de tension assignée au plus égale à
450/750 V (U0/U) - Partie 2-22: Câbles pour applications générales - Câbles sous tresse
à flexibilité élevée isolés en matériau élastomère réticulé
Ta slovenski standard je istoveten z: EN 50525-2-22:2011
ICS:
29.060.20 Kabli Cables
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 50525-2-22
NORME EUROPÉENNE
May 2011
EUROPÄISCHE NORM
ICS 29.060.20 Supersedes HD 22.14 S3:2007 (partially)

English version
Electric cables -
Low voltage energy cables of rated voltages up to and including 450/750 V
(U /U) -
Part 2-22: Cables for general applications -
High flexibility braided cables with crosslinked elastomeric insulation

Câbles électriques -  Kabel und Leitungen -
Câbles d’énergie basse tension de tension Starkstromleitungen mit Nennspannungen
assignée au plus égale à 450/750 V bis 450/750 V (U /U) -
(U /U) -
Teil 2-22: Starkstromleitungen für
Partie 2-22: Câbles pour applications allgemeine Anwendungen -
générales - Hochflexible umflochtene Leitungen mit
Câbles sous tresse à flexibilité élevée vernetzter Elastomer-Isolierung
isolés en matériau élastomère réticulé

This European Standard was approved by CENELEC on 2011-01-17. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50525-2-22:2011 E
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 20, Electric cables.
The text of the draft was submitted to the formal vote and was approved by CENELEC as
EN 50525-2-22 on 2011-01-17.
This document, which is one of a multipart series, partially supersedes HD 22.14 S3:2007.
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any
or all such patent rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2012-01-17
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-01-17

________________
- 3 - EN 50525-2-22:2011
Contents
Page
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Flexible cables - H03RT-H . 4
4.1 Construction . 4
4.2 Requirements . 5
Annex A (normative) Tests for cables to EN 50525-2-22 . 6
Annex B (normative) . 7
General data . 7
Annex C (normative) . 8
Measurement of coverage by textile braid. 8
C.1 Terms and definitions . 8
C.2 Test methods . 8
Bibliography . 10

Figures
Figure C.1 ― Textile braid . 9
Tables
Table A.1 . 6
Table B.1 . 7

1 Scope
EN 50525-2-22 applies to crosslinked EPR insulated and textile braided flexi
...