Lamp controlgear - Part 2-1: Particular requirements for starting devices (other than glow starters)

Corrigendum to EN issued November 2006

Geräte für Lampen - Teil 2-1: Besondere Anforderungen an Startgeräte (andere als Glimmstarter)

Appareillages de lampes - Partie 2-1: Prescriptions particulières pour les dispositifs d'amorçage (autres que starters à lueur)

Regulatorji žarnic – 2-1. del: Posebne zahteve za vžigne naprave (ki niso tlivni starterji) (IEC 61347-2-1:2000/A1:2005)

General Information

Status
Published
Publication Date
09-Mar-2006
Withdrawal Date
31-Jan-2009
Drafting Committee
IEC/SC 34C - IEC_SC_34C
Parallel Committee
IEC/SC 34C - IEC_SC_34C
Current Stage
6060 - Document made available - Publishing
Start Date
10-Mar-2006
Completion Date
10-Mar-2006

Relations

Effective Date
28-Jul-2020
Effective Date
29-Jan-2023

Overview

EN 61347-2-1:2001/A1:2006 is a European Standard issued by the CLC that specifies particular requirements for starting devices used in lamp controlgear, excluding glow starters. This corrigendum, released in November 2006, introduces amendments and normative updates to ensure compliance with evolving technical and safety criteria. The standard is closely aligned with IEC 61347-2-1:2000/A1:2005 and addresses controlgear components critical for lamp ignition.

Key Topics

  • Scope and Applicability
    Defines starting devices (also called ignitors) other than glow starters used in electrical lamp systems and provides safety and performance requirements specific to these devices.

  • Normative References Update
    Includes updated references to IEC standards such as IEC 60052:2002 for voltage measurement with standard air gaps, IEC 60068-2-75:1997 for environmental hammer tests, and IEC 60255-8:1990 on thermal electrical relays. This ensures harmonized testing procedures and consistency with related international standards.

  • Definitions and Terminology
    Clarifies terms such as starting device/ignitor, short-circuit power, and spherical spark gap to provide precise technical definitions crucial for standard interpretation.

  • Electrical Strength and Safety Tests
    Specifies electric strength tests for starting devices without high-voltage windings according to IEC 61347-1 to verify insulation and durability under electrical stress.

  • Fault Conditions and Thermal Requirements
    Sets limits on temperature rise during abnormal operation and outlines testing criteria to ensure devices maintain performance and safety under short-circuit and fault conditions.

  • Time Limitation for High-Voltage Ignitors
    Requires starting devices producing pulse voltages above 10 kV to include a time limitation feature that interrupts pulse generation after a preset maximum duration (typically 3 seconds, extendable up to 30 seconds with appropriate labelling) to prevent damage and improve safety.

  • Testing and Labeling Requirements
    Includes protocols for heating tests and mandatory labelling information to guide safe installation and maintenance of lamp controlgear starting devices.

Applications

  • Lighting Systems
    EN 61347-2-1 applies to auxiliary starting devices integrated into lighting controlgear across commercial, industrial, and residential environments.

  • Controlgear Manufacturing
    Manufacturers use the standard to design and evaluate starting devices ensuring they meet international safety and performance benchmarks.

  • Compliance and Safety Certification
    Ensures that lamp controlgear starting devices meet essential health and safety requirements to protect end-users and equipment under normal and fault conditions.

  • Testing Laboratories
    Provides standardized methods for laboratory testing including electrical strength, thermal behavior, and performance of starting devices to certify conformity.

Related Standards

  • IEC 61347-1
    General requirements for lamp controlgear, which form the foundation for the specific clauses in EN 61347-2-1 regarding testing and safety.

  • IEC 60052:2002
    Standard for voltage measurement using air gaps, critical for validating voltage withstand capabilities of starting devices.

  • IEC 60068-2-75:1997
    Environmental hammer tests relevant for assessing the mechanical robustness of starting devices.

  • IEC 60255-8:1990
    Pertains to thermal electrical relays, providing context for thermal testing and limits on heating in lamp controlgear components.

Practical Value

Adherence to EN 61347-2-1:2001/A1:2006 ensures that starting devices used in lamp controlgear are designed, tested, and labeled according to rigorous European and international standards, promoting reliability, operational safety, and consistency in lighting technology. This standard plays a critical role in the manufacturing and certification process for starting devices that facilitate the ignition of lamps while preventing electrical faults, overheating, and operational hazards. Manufacturers, installers, and compliance authorities benefit from clear guidelines that help reduce failures and improve product quality in lighting control systems.

Amendment

EN 61347-2-1:2002/A1:2006

English language
6 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

EN 61347-2-1:2001/A1:2006 is a amendment published by CLC. Its full title is "Lamp controlgear - Part 2-1: Particular requirements for starting devices (other than glow starters)". This standard covers: Corrigendum to EN issued November 2006

Corrigendum to EN issued November 2006

EN 61347-2-1:2001/A1:2006 is classified under the following ICS (International Classification for Standards) categories: 29.140.99 - Other standards related to lamps. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 61347-2-1:2001/A1:2006 has the following relationships with other standards: It is inter standard links to EN IEC 61347-2-1:2024, EN 61347-2-1:2001. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 61347-2-1:2001/A1:2006 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase EN 61347-2-1:2001/A1:2006 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.

Standards Content (Sample)


SLOVENSKI STANDARD
01-junij-2006
Regulatorji žarnic – 2-1. del: Posebne zahteve za vžigne naprave (ki niso tlivni
starterji) (IEC 61347-2-1:2000/A1:2005)
Lamp controlgear -- Part 2-1: Particular requirements for starting devices (other than
glow starters)
Geräte für Lampen -- Teil 2-1: Besondere Anforderungen an Startgeräte (andere als
Glimmstarter)
Appareillages de lampes -- Partie 2-1: Prescriptions particulières pour les dispositifs
d'amorçage (autres que starters à lueur)
Ta slovenski standard je istoveten z: EN 61347-2-1:2001/A1:2006
ICS:
29.130.01 Stikalne in krmilne naprave Switchgear and controlgear
na splošno in general
29.140.99 Drugi standardi v zvezi z Other standards related to
žarnicami lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

Corrigendum to EN 61347-2-1:2001/A1:2006
English version
___________
Foreword
the last paragraph by:
Replace
Annex ZA has been added by CENELEC.

Annex ZA (see overleaf):
Add
November 2006
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year

Replace the reference to IEC 60052 by the following new reference:

IEC 60052 2002 Voltage measurement by means of standard EN 60052 2002
air gaps
Insert a date for the references to IEC 60068-2-75 and IEC 60255-8:

IEC 60068-2-75 1997 Environmental testing EN 60068-2-75 1997
Part 2-75: Tests - Test Eh: Hammer tests

IEC 60255-8 (mod) 1990 Electrical relays EN 60255-8 1998
Part 8: Thermal electrical relays

___________
NORME CEI
INTERNATIONALE
IEC
61347-2-1
INTERNATIONAL
STANDARD
AMENDEMENT 1
AMENDMENT 1
2005-11
Amendement 1
Appareillages de lampes –
Partie 2-1:
Prescriptions particulières pour les dispositifs
d'amorçage (autres que starters à lueur)

Amendment 1
Lamp controlgear –
Part 2-1:
Particular requirements for starting devices
(other than glow starters)
 IEC 2005 Droits de reproduction réservés  Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
D
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue

61347-2-1 Amend. 1  IEC:2005 – 3 –
FOREWORD
This amendment has been prepared by subcommittee 34C: Auxiliaries for lamps, of IEC
technical committee 34: Lamps and related equipment.
The text of this amendment is based on the following documents:
FDIS Report on voting
34C/697/FDIS 34C/709/RVD
Full information on the voting for the approval of this amendment can be fo
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...