EN IEC 61760-4:2026
(Main)Surface mounting technology - Part 4: Classification, packaging, labelling and handling of moisture sensitive devices
- Abstract
This part of IEC 61760 specifies the classification of moisture sensitive device into moisture sensitivity level related to soldering heat, and provisions for packaging, labelling and handling.
It extends the classification and packaging methods to such components, where currently existing standards are not required or not appropriate. For such cases, this document
introduces additional moisture sensitivity levels and an alternative method for packaging. This document applies to devices intended for reflow soldering, like surface mount devices, including specific through-hole devices (where the device supplier has specifically documented support for reflow soldering), but not to
– semiconductor devices,
– devices for flow (wave) soldering.
NOTE Background of this document and its relation to currently existing standards, e.g. IEC 60749-20 [1] or J-STD-020F [2] and J-STD-033 [3], are described in the Introduction.
- Status
- Published
- Publication Date
- 23-Jul-2026
- Technical Committee
- CLC/SR 91 - Electronics assembly technology
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 24-Jul-2026
- Due Date
- 31-Dec-2025
- Completion Date
- 31-Dec-2025
EN IEC 61760-4:2026 is a CENELEC European Standard based on IEC 61760-4:2026. It specifies how moisture sensitive devices are classified, packaged, labelled and handled for reflow soldering, including surface mount devices and certain through-hole devices for which the supplier has documented reflow support. It is intended for component suppliers, distributors and electronics assemblers that need a common method to control moisture exposure before soldering.
What does EN IEC 61760-4:2026 specify?
EN IEC 61760-4:2026 specifies the moisture sensitivity level (MSL) system, the test method used to assign a level, and the packaging, labelling and handling provisions that go with that level. The standard applies to devices intended for reflow soldering and excludes semiconductor devices and devices for flow soldering.
The document is organized into clauses 1 to 9, followed by four annexes.
| Annex | What it covers |
|---|---|
| Annex A | Moisture sensitivity of assemblies |
| Annex B | Mass/gain loss analysis |
| Annex C | Baking of devices |
| Annex D | Moisture sensitivity labels |
Clause 1 states the scope, Clause 2 gives the normative reference, Clause 3 defines the main terms, Clauses 4 to 6 cover moisture sensitivity, testing and classification, Clauses 7 to 9 cover packaging, handling and drying, and Annex D gives the label system used on packaging.
What are the key requirements of EN IEC 61760-4:2026?
EN IEC 61760-4:2026 sets up a practical workflow: identify whether a device is moisture sensitive, classify it to an MSL, test it under controlled moisture and reflow conditions, then package and handle it so that the level remains valid.
Clause 5.1 - Non-moisture sensitive devices
EN IEC 61760-4:2026 allows a device to be declared level N when design and material analysis show that it does not absorb moisture or admit moisture into cavities. In practice, this is the simplest case: the supplier can state that special dry-pack controls are not required.Clause 5.2 - Classification into MSL
EN IEC 61760-4:2026 classifies moisture sensitive devices using the lowest level they can pass, based on the selected soak condition and classification temperature profile. The practical point is that the relevant specification should say which level applies, because that level drives packaging, floor life and rework handling.Clauses 6.2 to 6.4 - Preconditioning and reflow test
EN IEC 61760-4:2026 requires drying before moisture soak, then moisture soak, then three reflow cycles under the classification profile. The standard gives the temperature profile, soak conditions and special profiles for devices that do not fit the default case, so test labs and suppliers can use the same basis for evaluation.Clause 6.5 and 6.6 - Recovery and final checks
EN IEC 61760-4:2026 requires recovery under standard atmospheric conditions, then visual inspection, electrical measurements and, if specified, non-destructive inspection. In practice, this means the device must still meet appearance, mechanical integrity and electrical requirements after the moisture and reflow sequence.Clause 6.6.2 - Failure criteria
EN IEC 61760-4:2026 treats cracks, delamination affecting internal connections, damaging deformation, warpage, swelling, bulging and out-of-spec dimensions as failures. This matters because the document is focused on soldering reliability, not just visual appearance.Clause 6.7 - Extreme moisture sensitivity
EN IEC 61760-4:2026 treats devices that do not pass level 5 as extremely moisture sensitive. The supplier must warn the customer, and the label must indicate that the device must either be socket mounted or baked dry within the stated time before reflow soldering.Clauses 7 and 8 - Packaging, labels and handling
EN IEC 61760-4:2026 requires dry packing in a moisture barrier bag (MBB), with desiccant and humidity indication, plus labels showing the moisture sensitivity information. It also sets storage and handling expectations, including shelf life, floor life, ESD precautions and rules for opening, resealing and re-drying.Clause 9 - Drying before use or before dry pack
EN IEC 61760-4:2026 allows re-bake and pre-pack baking methods that reset floor life, and it limits baking conditions to protect solderability. In practice, this clause is the recovery route when devices have been exposed too long or when they must be dried before packing.
What terms does EN IEC 61760-4:2026 define?
- Moisture sensitive device (MSD) - a device that can suffer electrical or mechanical degradation during soldering because absorbed moisture vaporizes.
- Moisture sensitivity level (MSL) - the rating that shows how susceptible a device is to moisture damage during reflow soldering.
- Moisture barrier bag (MBB) - a bag designed to restrict water vapour transmission and used for dry packing MSDs.
- Manufacturer’s exposure time (MET) - the maximum time a component may remain unsealed after baking before it must be packed.
- Floor life - the time a device may stay in normal room conditions after opening the MBB and before reflow soldering.
- Shelf life - the acceptable storage time of products in their original packaging under specified conditions.
- Humidity indicator card (HIC) - a card that changes colour as relative humidity rises above the marked level.
- Water vapour transmission rate (WVTR) - the measure used to describe how much moisture can pass through the MBB material.
Who uses EN IEC 61760-4:2026?
EN IEC 61760-4:2026 is used by component suppliers, distributors, contract manufacturers and electronics assembly plants that handle moisture sensitive parts. Quality engineers use it to define acceptance criteria, packaging rules and inspection steps. Buyers and product engineers use it when they need a delivery, storage or reflow condition to be specified in the procurement or product specification. It is also relevant to packaging engineers, warehouse staff and test laboratories working with reflow-soldered electronic components.
What changed in EN IEC 61760-4:2026 from the previous edition?
EN IEC 61760-4:2026 supersedes EN 61760-4:2015 and its Amendment 1:2018. The IEC foreword says this second edition is a technical revision.
The stated technical change is that the content has been updated to cover the classification conditions in the newer editions of J-STD-020F and IEC 60068-2-58. The European foreword also confirms that CENELEC approved the IEC text without modification.
Which standards are used with EN IEC 61760-4:2026?
EN IEC 61760-4:2026 cites IEC 60068-1:2013 as its normative reference for the atmospheric conditions used in recovery and measurement. The bibliography and annex notes also point to several related standards that support specific parts of the process:
- IEC 60068-2-58:2015 / IEC 60068-2-58 - alternative classification profiles for special devices.
- IEC 61760-2 - storage conditions for moisture sensitive devices.
- IEC 61340-5-1 - ESD handling guidance during dry, low-humidity processing.
- IEC 60068-2-78 - humidity test context that the introduction contrasts with this moisture/reflow method.
- IEC 60749-20, J-STD-020F and J-STD-033 - related moisture sensitivity and dry-pack methods referenced for context and equivalence.
- ISO 62, ASTM D 570 and MIL-PRF-131J - methods and references for water vapour transmission measurement of barrier films.
- ISO 2859-1 - sampling context for the specimen number example in the test procedure.
- IEC 60417 and JEDEC JEP113 - symbols and label examples used for moisture sensitivity marking.
What does the EN IEC 61760-4:2026 document contain?
EN IEC 61760-4:2026 contains the classification temperature profile, moisture soak conditions, MSL tables, packaging material guidance, desiccant calculation formulas and label examples needed to run a moisture sensitivity control process. It also includes figures showing the classification profile, humidity indicator cards, the baking process and the standardized moisture sensitive device symbol.
The document gives procedures for drying, soaking, reflow testing, recovery, visual inspection, optional non-destructive inspection and final pass/fail decision making. Annex B and Annex C provide practical baking and mass-change guidance, while Annex D provides the labels and symbols used on bags and shipping containers.
For a plant or supplier, the value of the document is that it links the test result to the real handling rules: how long parts may stay open, how they should be packed, what humidity indication is acceptable, and when re-drying is required before reflow soldering.
Relations
- Effective Date
- 09-Apr-2024
- Effective Date
- 09-Apr-2024
- Effective Date
- 23-Jun-2026
- Effective Date
- 28-Jul-2026
- Effective Date
- 28-Jul-2026
- Effective Date
- 28-Jul-2026
- Effective Date
- 28-Jul-2026
Frequently Asked Questions
EN IEC 61760-4:2026 is a standard published by CLC. Its full title is "Surface mounting technology - Part 4: Classification, packaging, labelling and handling of moisture sensitive devices". This standard covers: This part of IEC 61760 specifies the classification of moisture sensitive device into moisture sensitivity level related to soldering heat, and provisions for packaging, labelling and handling. It extends the classification and packaging methods to such components, where currently existing standards are not required or not appropriate. For such cases, this document introduces additional moisture sensitivity levels and an alternative method for packaging. This document applies to devices intended for reflow soldering, like surface mount devices, including specific through-hole devices (where the device supplier has specifically documented support for reflow soldering), but not to – semiconductor devices, – devices for flow (wave) soldering. NOTE Background of this document and its relation to currently existing standards, e.g. IEC 60749-20 [1] or J-STD-020F [2] and J-STD-033 [3], are described in the Introduction.
This part of IEC 61760 specifies the classification of moisture sensitive device into moisture sensitivity level related to soldering heat, and provisions for packaging, labelling and handling. It extends the classification and packaging methods to such components, where currently existing standards are not required or not appropriate. For such cases, this document introduces additional moisture sensitivity levels and an alternative method for packaging. This document applies to devices intended for reflow soldering, like surface mount devices, including specific through-hole devices (where the device supplier has specifically documented support for reflow soldering), but not to – semiconductor devices, – devices for flow (wave) soldering. NOTE Background of this document and its relation to currently existing standards, e.g. IEC 60749-20 [1] or J-STD-020F [2] and J-STD-033 [3], are described in the Introduction.
EN IEC 61760-4:2026 is classified under the following ICS (International Classification for Standards) categories: 31.190 - Electronic component assemblies. The ICS classification helps identify the subject area and facilitates finding related standards.
EN IEC 61760-4:2026 has the following relationships with other standards: It is inter standard links to EN 61760-4:2015/A1:2018, EN 61760-4:2015, EN 60068-1:2014, EN IEC 62878-1:2019, EN IEC 62435-8:2020, EN IEC 61760-1:2026, EN IEC 61760-1:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN IEC 61760-4:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 moisture sensitive device
- 3.2 moisture sensitivity level
- 3.3 moisture barrier bag
- 3.4 manufacturer’s exposure time
- 3.5 floor life
- 3.6 shelf life
- 3.7 active desiccant
- 3.8 moisture indicating desiccant
- 3.9 humidity indicator card
- 3.10 water vapour transmission rate
- 4 General information
- 4.1 Moisture sensitive devices
- 4.2 Moisture sensitivity level (MSL)
- 4.3 Relation to other environmental test methods (humidity tests)
- 5 Assessment of moisture sensitivity
- 5.1 Identification of non-moisture sensitive devices
- 5.2 Classification
- 6 Test procedure
- 6.1 General
- 6.2 Drying
- 6.3 Moisture soak
- 6.4 Temperature load
- 6.5 Recovery
- 6.6 Final measurements
- 6.7 Classification
- 6.8 Information to be given in the relevant specification
- 7 Requirements to packaging and labelling
- 7.1 Packaging process
- 7.2 Packaging material for dry pack
- 7.3 Information to be given on labels
- 8 Handling of moisture sensitive devices
- 8.1 Storage
- 8.2 ESD
- 8.3 Humidity indication
- 8.4 Unpacking and re-packing
- 9 Drying
- 9.1 Drying options
- 9.2 Methods
- Annex A
- Annex B
- Annex C
- Annex D
- Bibliography
INTRODUCTION Due to the higher temperature profiles of reflow soldering processes using tin-silver-copper alloys or other lead-free solder alloys with higher melting temperatures than Sn-Pb eutectic solder, the sensitivity of components against soldering heat, when being exposed to moisture before soldering, becomes an increasingly important factor.
The currently existing standards describing the moisture sensitivity classification of devices are applicable for plastic encapsulated semiconductors and similar solid state packages (e.g. IEC 60749-20 [1]), but not for other types of components.
This part of IEC 61760 also extends the classification and packaging methods as described in J-STD-020F [2] and J-STD-033 [3]. It is intended to be used for such type of components, where J-STD-020F [2] and J-STD-033 [3] are not required or not appropriate. It is important to note that moisture sensitivity levels existing in both J-STD-020F [2] and this document are equivalent.
SIST EN IEC 61760-4:2026
1 Scope
This part of IEC 61760 specifies the classification of moisture sensitive device into moisture sensitivity level related to soldering heat, and provisions for packaging, labelling and handling. It extends the classification and packaging methods to such components, where currently existing standards are not required or not appropriate. For such cases, this document introduces additional moisture sensitivity levels and an alternative method for packaging. This document applies to devices intended for reflow soldering, like surface mount devices, including specific through-hole devices (where the device supplier has specifically documented support for reflow soldering), but not to - semiconductor devices, - devices for flow (wave) soldering.
NOTE Background of this document and its relation to currently existing standards, e.g. IEC 60749-20 [1] or J-STD-020F [2] and J-STD-033 [3], are described in the Introduction.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60068-1:2013, Environmental testing - Part 1: General and guidance
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- IEC Electropedia: available at https://www.electropedia.org/
- ISO Online browsing platform: available at https://www.iso.org/obp
3.1 moisture sensitive device
MSD device where during soldering the evaporation of absorbed moisture is likely to deteriorate its electrical or mechanical performance compared to what is given in the relevant specification Note 1 to entry: This note applies to the French language only.
3.2 moisture sensitivity level
MSL rating indicating a device’s susceptibility to damage due to absorbed moisture when subjected to reflow soldering Note 1 to entry: This note applies to the French language only.
SIST EN IEC 61760-4:2026
3.3 moisture barrier bag
MBB bag designed to restrict the transmission of water vapour and used to pack moisture sensitive devices (3.1) Note 1 to entry: This note applies to the French language only.
3.4 manufacturer’s exposure time
MET maximum time after baking that the component manufacturer requires to process components prior to sealing of the bag Note 1 to entry: The manufacturer’s exposure time also includes the maximum time allowed at the distributor in order to keep the bag open to split up its content into smaller shipments. Note 2 to entry: This note applies to the French language only.
3.5 floor life
allowable time for a device or semi-finished assembly to be exposed to normal room environment humidity and temperature after removal from a moisture barrier bag (3.3) or storage chamber and before a solder reflow process
3.6 shelf life
recommendation of time that products can be stored in the original packaging, during which the defined quality of the goods remains acceptable under specified conditions of transportation, storage and handling
3.7 active desiccant
absorbent material used to maintain a low relative humidity
3.8 moisture indicating desiccant
desiccant whose colour (hue) changes perceptibly, when a certain relative humidity is exceeded Note 1 to entry: Typically a colour change due to a moisture indicating desiccant is from blue to pink, when the change from dry state to wet state is detected.
3.9 humidity indicator card
HIC card on which a moisture sensitive chemical is printed such that it changes colour from dry to wet when the indicated relative humidity is exceeded Note 1 to entry: This note applies to the French language only.
3.10 water vapour transmission rate
WVTR measure of the permeability of a plastic film material to moisture, used to specify a moisture barrier bag (3.3) for dry packing Note 1 to entry: This note applies to the French language only.
SIST EN IEC 61760-4:2026
4 General information
4.1 Moisture sensitive devices
Certain materials, plastic polymers and fillers are hygroscopic and can absorb moisture dependent on time and the storage environment. Absorbed moisture will vaporize during rapid heating in the solder reflow process, generating - pressure in the material, - deformation, - swelling, - delamination, - cracking, - degradation of inner connection.
The penetration of moisture into the absorbing material is generally caused through exposure to the ambient air. Moisture absorption or moisture penetrating into cavities can lead to moisture concentrations in the device which are high enough to cause cracking or delamination to the device during the soldering process (e.g. “popcorn phenomenon”), which can adversely affect reliability.
NOTE “Popcorn phenomenon” defines internal stress causes the package to bulge and then crack with an audible “pop”.
Moisture can also influence the bonding strength of adhesives, sealings, encapsulants, plastics with galvanic coating, etc.
Moisture exposure also can induce the transport of ionic contaminations into the device, thereby increasing the potential for circuit failure due to corrosion. Hence it is necessary to dry moisture sensitive devices , to seal them in a moisture barrier bag and to remove them immediately prior to soldering onto the circuit board. The permissible time, from the opening of the moisture barrier bag until the final soldering process, that a device can remain unprotected in an environment with a level of humidity approximating to real-world conditions (e.g. 30 °C/60 % RH) is a measure of the sensitivity of the device to ambient humidity. This amount of time is called floor life.
4.2 Moisture sensitivity level (MSL)
The moisture sensitivity level (MSL) is determined at the classification temperature, which is set above practical soldering temperatures. The actual soldering temperature measured at the top surface of the component therefore shall be less than the classification temperature. Packaging, storage, floor life and pre-treatment of moisture sensitive devices before being subjected to reflow soldering processes are identified by the MSL (see Clause 5 and Table 1). The method for classification of devices into MSL is described in Clause 6.
4.3 Relation to other environmental test methods (humidity tests)
In humidity tests, for example as in IEC 60068-2-78 [4], devices are tested either in unmounted or in mounted condition (e.g. soldered to a test board). These tests detect the influence of adsorbed or absorbed moisture to the performance of the device (e.g. electrical characteristics, corrosion effects), but cannot detect the influence of absorbed moisture to the sensitivity against heat stresses of the soldering processes.
The target of the test method described in this document is to test the resistance of devices against the soldering heat in combination with the humidity load as preconditioning process.
SIST EN IEC 61760-4:2026
Other effects of humidity, like deterioration of electrical characteristics or isolation properties, are not covered by this document and shall be tested separately.
5 Assessment of moisture sensitivity
5.1 Identification of non-moisture sensitive devices
Non-moisture sensitive devices shall be identified by analysis of design and materials of devices depending on whether they can absorb humidity, or humidity can penetrate into cavities. If the materials apparently do not absorb humidity, the devices can be declared by the manufacturer as non-moisture sensitive.
Such non-moisture sensitive devices shall be designated as level “N”. There are no requirements for non-moisture sensitive devices .
5.2 Classification
The procedure to classify moisture sensitive devices into MSL is described in Clause 6. The devices are classified at the appropriate classification temperature selected from Table 3 and Table 4. See Annex A for the classification of semi-finished assemblies. The recommended procedure is to start testing at the lowest moisture sensitivity level, which the evaluation package is reasonably expected to pass (based on knowledge of other similar evaluation packages).
If suppliers and users agree, components can be classified at temperatures other than those in Table 4.
If the conditions in Table 1 or Table 2 are not suitable for a specific product, other conditions can be applied according to the agreement between users and suppliers. Table 1 – Moisture sensitivity levels LEVEL floor life Floor life shelf life Protective packaging Desicca Humidity time condition nt indicator (reference condition) 1 a ≤30 °C/85 % RH 12 months No requirement
or as 2 a ≤30 °C/60 % RH b No Optional specified 1 year MBB type 1 , <60 % RH in
by the MBB no pre-drying supplier C2a 4 weeks ≤30 °C/60 % RH b Yes c MBB type 1 , <30 % RH in Yes MBB no pre-drying 2a b MBB type 2 , <10 % RH in MBB pre-drying C3 168 h ≤30 °C/60 % RH b Yes c MBB type 1 , <30 % RH in Yes MBB no pre-drying 3 b MBB type 2 , <10 % RH in MBB pre-drying 4 72 h ≤30 °C/60 % RH b Yes c MBB type 2 , <10 % RH Yes in MBB pre-drying 5 48 h ≤30 °C/60 % RH c Yes c MBB type 2 , <10 % RH Yes in MBB pre-drying
SIST EN IEC 61760-4:2026
LEVEL floor life Floor life shelf life Protective packaging Desicca Humidity time condition nt indicator (reference condition) The floor life can be longer if the environmental conditions are less severe than the reference condition, or shorter, if more severe.
Extended shelf life can be agreed upon, but requires recalculation of the amount of desiccant. a The sum of keeping time at floor and storage time should not exceed the maximum storage period as specified by the supplier.
b The required shelf life and humidity in packed condition shall be assured by the amount of the desiccant, calculated by the use of water vapour transmission rate (WVTR) of the applied MBB. For the description of MBB type, see Table 5.
Humidity indicator can be HIC or moisture indicating desiccant.
6 Test procedure
6.1 General
6.1.1 Structurally similar components
Classification may be performed for a group of structurally similar components. Information about structural similarity shall be given in the relevant specification.
6.1.2 Verification and validation tests
The relevant specification shall describe the minimum number of specimens to be tested. The minimum number should be at least 11 pieces.
NOTE A sample of 11 pieces tested with an acceptance number zero represents a Lot Tolerance Percent Defective (LTPD) of 20 % with a confidence level (C.L.) of 90 %. See ISO 2859-1 [5] for further information.
6.1.3 Selection of applicable soak conditions and temperature profile
The soak conditions related to the MSL shall be selected from Table 2, the applicable temperature profile for classification (Figure 1) from Table 3 and Table 4.
6.2 Drying
The specimen shall be baked at 125 °C ± 5 °C for at least 24 h, unless otherwise specified in the relevant specification.
However, alternative baking conditions may be applied, when confirmed by the mass gain or loss analysis as described in Annex B.
6.3 Moisture soak
Table 2 – Moisture soak conditions LEVEL Soak time (h) a Alternative Soak condition 1 (168 +5/−0) (85 ± 2) °C, (85 ± 5) % RH (336 +5/−0) h; (85 ± 2) °C, (60 ± 5) % RH 2 (168 +5/−0) (85 ± 2) °C, (60 ± 5) % RH – C2a (168 +5/−0) (85 ± 2) °C, (30 ± 5) % RH, – followed by followed by (30 ± 2) °C, (672 +5/−0) (60 ± 5) % RH 2a (696 + 5/−0) (30 ± 2) °C, (60 ± 5) % RH C3 (168 +5/−0) (85 ± 2) °C, (30 ± 5) % RH, followed by followed by (30 ± 2) °C, (168 +5/−0) (60 ± 5) % RH
SIST EN IEC 61760-4:2026
LEVEL Soak time (h) a Alternative Soak condition 3 (192 +5/−0) (30 ± 2) °C, (60 ± 5) % RH 4 (96 +2/−0) (30 ± 2) °C, (60 ± 5) % RH 5 (72 +2/−0) In levels C2a and C3, the first stage of soak condition corresponds to shelf life (≤30 °C, ≤30 % RH, one year) in the MBB type 1. The second stage of soak condition corresponds to floor life (as in IEC 60749-20 [1]). a Soak conditions according to J-STD-020F [2]. Alternatively accelerated equivalent soak conditions from Table 4 in J-STD-020F [2] may be applied in case the activation energy is confirmed by the manufacturer.
6.4 Temperature load
6.4.1 Classification temperature profile
Key Minimum preheating temperature T
Maximum preheating temperature T
Liquidus temperature T
Classification temperature T
Preheating duration t
Time at liquidus t
t Time within (T – 5 °C) 3 c t Time to T 4 c a Temperature gradient of the increasing slope b Preheat area c Temperature gradient of the decreasing slope The temperature gradient of the increasing slope shall not exceed 3 K/s and the temperature gradient of the decreasing slope shall not exceed 6 K/s.
Figure 1 – Classification temperature profile
SIST EN IEC 61760-4:2026
Table 3 – Parameters of the classification temperature profile Solder Sn-Pb (or equivalent) SnAgCu (or equivalent) Sn-Bi (or equivalent) process 100 °C 150 °C 100 °C T
150 °C 200 °C 120 °C T
(60 to 120) s (60 to 120) s (30 to 90) s t
183 °C 217 °C 139 °C T
(60 to 150) s (60 to 150) s (60 to 150) s t
20 s 30 s 20 s t
See Table 4 T
≤6 min ≤8 min ≤4 min t
Table 4 – Classification temperatures T
Solder process Package Classification temperature T for package volume
thickness 3 3 3 <350 mm 350 mm to >2 000 mm
2 000 mm mm °C °C °C
SnPb (or <2,5 235 220 220 equivalent) ≥2,5 220 220 220 SnAgCu (or <1,6 260 260 260 equivalent) 1,6 to 2,5 260 250 245 >2,5 250 245 245 >2,5 plus high not applicable b b 230 230 a thermal capacity Sn-Bi (or All package thickness and volume: 190 equivalent) [LTS] a This condition may be applied for devices with high thermal mass, where peak package temperature does not reach 245 °C when soldered with a profile typical to soldering processes using SnAgCu alloy solder, or for very temperature sensitive devices. The peak package temperature is measured at the device surface or any other point specified in the relevant specification.
b T measured at the device terminal or solder joint shall achieve the minimum temperature and time necessary
for a specific solder alloy to form a solder joint.
6.4.2 Classification temperature profile for special devices
When the classification temperature profiles of Table 3 and Table 4 are not applicable to a device (e.g. components with high thermal mass or thermal sensitivity) the temperature profiles in IEC 60068-2-58:2015 [6], Table 7, can be used. Other profiles may be specified in the relevant specification according to the agreement between user and supplier. For information see also J-STD 075A [7].
6.4.3 Reflow
The sample shall be subjected to 3 cycles of the appropriate reflow conditions as defined in Figure 1, Table 3 and Table 4, starting in a time interval of 15 min to 4 h after removal from the temperature/humidity chamber. The recovery period between two successive cycles shall be the time it takes until the temperature of the specimen drops below 50 °C.
SIST EN IEC 61760-4:2026
If the timing between removal from climatic test chamber and initial reflow cannot be met, the parts shall be rebaked and resoaked according to 6.2 and 6.3.
...