Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-081: Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes

NEW! IEC 61010-2-081:2015 is available as IEC Standards+ 61010-2-081:2015 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61010-2-081:20 15 applies to automatic and semi-automatic laboratory equipment for analysis and other purposes. Automatic and semi-automatic laboratory equipment consists of instruments or systems for measuring or modifying one or more characteristics or parameters of samples, performing the complete process or parts of the process without manual intervention. Equipment forming part of such a system is within the scope of this standard. This second edition cancels and replaces the first edition published in 2003. It constitutes a technical revision and includes the following signif icant changes from the first edition, as well as numerous other changes: - excluded IEC 61010-2-101 (IVD Equipment) from scope. This separates IEC 61010-2-081 and IEC 61010-2-101 equipment; - added biological risks symbol to Table 1 in Clause 5; - added requirement for statement on hazardous substances and gases in Instructions for Use to Clause 5; - Added marking requirement for flow direction to Clause 5; - added requirement for OPERATOR maintenance instructions to Clause 7; - excluded equipment whose size and weight make unintentional movement unlikely from drop test in Clause 8; - added requirement for biohazard marking to Clause 13; - added requirement for interlock systems containing electric/electronic or programmable components to Clause 15. It has the status of a group safety publication in accordance with IEC Guide 104.

Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regel- und Laborgeräte - Teil 2-081: Besondere Anforderungen an automatische und semiautomatische Laborgeräte für Analysen und andere Zwecke

Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 2-081: Exigences particulières pour les appareils de laboratoire, automatiques et semi-automatiques, destinés à l’analyse et autres usages

NEW! IEC 61010-2-081:2015 est disponible sous forme de IEC Standards+ 61010-2-081:2015 qui contient la Norme internationale et sa version Redline, illustrant les modifications du contenu technique depuis l'édition précédente. L'IEC 61010-2-081:2015 s'applique aux appareils de laboratoire, automatiques et semi-automatiques, destinés à l'analyse et autres usages. Les appareils de laboratoire automatiques et semi-automatiques comprennent les instruments ou systèmes utilisés pour mesurer ou modifier un ou plusieurs paramètres ou caractéristiques d'échantillons, réalisant tout ou partie du processus sans intervention manuelle. Les équipements faisant partie d'un tel système sont couverts par le domaine d'application de la présente norme. Cette deuxième édition annule et remplace la première édition parue en 2003. Cette édition constitue une révision technique et inclut les modifications techniques majeures suivantes par rapport à la première édition, ainsi que de nombreuses autres modifications: - exclusion de l'IEC 61010-2-101 (appareils DIV) du domaine d'application, ce qui distingue les appareils de l'IEC 61010-2-081 et ceux de l'IEC 61010-2-101; - ajout d'un symbole relatif aux risques biologiques dans le Tableau 1 à l'Article 5; - ajout d'une exigence relative aux indications sur les substances et gaz dangereux dans les Instructions d'utilisation à l'Article 5; - ajout d'une exigence relative au marquage du sens de circulation à l'Article 5; - ajout d'une exigence relative aux instructions d'entretien par l'OPÉRATEUR à l'Article 7; - exclusion des appareils dont la taille et le poids rendent improbable un mouvement involontaire de l'essai de chute à l'Article 8; - ajout d'une exigence relative au marquage des dangers biologiques à l'Article 13; - ajout d'une exigence relative aux systèmes de verrouillage incluant des composants électriques/électroniques ou programmables à l'Article 15. Cette norme a le statut de publication groupée de sécurité, conformément au Guide 104 de l'IEC.

Varnostne zahteve za električno opremo za meritve, nadzor in laboratorijsko uporabo - 2-081. del: Posebne zahteve za avtomatsko in polavtomatsko laboratorijsko opremo, ki se uporablja za analizo in druge namene (IEC 61010-2-081:2015)

Standard IEC 61010-2-081 se uporablja za avtomatsko in polavtomatsko laboratorijsko opremo, ki se uporablja za analizo in druge namene. Avtomatska in polavtomatska laboratorijska oprema zajema instrumente ali sisteme za merjenje ali spreminjanje ene ali več karakteristik ali parametrov vzorcev, izvajanje celotnega procesa ali delov procesa brez ročnega posredovanja. Področje uporabe tega standarda zajema opremo, ki tvori del takega sistema. Med primere opreme znotraj področja uporabe tega standarda spadajo: – analizna oprema; – avtomatska naprava za vzorčenje (pipetor, naprava za odvzem alikvota); – oprema za razmnoževanje in pomnoževanje vzorcev.
Ta revidirana različica zagotavlja hiter in enostaven način za primerjavo vseh sprememb med tem standardom in njegovo prejšnjo izdajo. Spremembe so na robu označene z navpičnim stolpcem. Dodatki in izbrisi so prikazani v rdeči barvi, pri čemer so izbrisi prečrtani.

General Information

Status
Withdrawn
Publication Date
19-Mar-2015
Withdrawal Date
26-Feb-2018
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
22-May-2023
Completion Date
22-May-2023

Relations

Buy Standard

Standard
EN 61010-2-081:2015
English language
14 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61010-2-081:2015
01-oktober-2015
9DUQRVWQH]DKWHYH]DHOHNWULþQRRSUHPR]DPHULWYHQDG]RULQODERUDWRULMVNR
XSRUDERGHO3RVHEQH]DKWHYH]DDYWRPDWVNRLQSRODYWRPDWVNR
ODERUDWRULMVNRRSUHPRNLVHXSRUDEOMD]DDQDOL]RLQGUXJHQDPHQH ,(&

Safety requirements for electrical equipment for measurement, control and laboratory
use - Part 2-081: Particular requirements for automatic and semi-automatic laboratory
equipment for analysis and other purposes (IEC 61010-2-081:2015)
Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regel- und Laborgeräte - Teil 2
-081: Besondere Anforderungen an automatische und semiautomatische Laborgeräte für
Analysen und andere Zwecke (IEC 61010-2-081:2015)
Règles de sécurité pour appareils électriques de mesurage, de régulation et de
laboratoire - Partie 2-081: Prescriptions particulières pour les appareils de laboratoire,
automatiques et semi-automatiques, destinés à l’analyse et autres usages (IEC 61010-2-
081:2015)
Ta slovenski standard je istoveten z: EN 61010-2-081:2015
ICS:
19.080 (OHNWULþQRLQHOHNWURQVNR Electrical and electronic
SUHVNXãDQMH testing
71.040.10 Kemijski laboratoriji. Chemical laboratories.
Laboratorijska oprema Laboratory equipment
SIST EN 61010-2-081:2015 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61010-2-081:2015

---------------------- Page: 2 ----------------------

SIST EN 61010-2-081:2015


EUROPEAN STANDARD EN 61010-2-081

NORME EUROPÉENNE

EUROPÄISCHE NORM
March 2015
ICS 19.080; 71.040.10 Supersedes EN 61010-2-081:2002
English Version
Safety requirements for electrical equipment for measurement,
control and laboratory use - Part 2-081: Particular requirements
for automatic and semi-automatic laboratory equipment for
analysis and other purposes
(IEC 61010-2-081:2015)
Règles de sécurité pour appareils électriques de mesurage, Sicherheitsbestimmungen für elektrische Mess-, Steuer-,
de régulation et de laboratoire - Partie 2-081: Exigences Regel- und Laborgeräte - Teil 2-081: Besondere
particulières pour les appareils de laboratoire, automatiques Anforderungen an automatische und semiautomatische
et semi-automatiques, destinés à l'analyse et autres usages Laborgeräte für Analysen und andere Zwecke
(IEC 61010-2-081:2015) (IEC 61010-2-081:2015)
This European Standard was approved by CENELEC on 2015-02-27. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 61010-2-081:2015 E

---------------------- Page: 3 ----------------------

SIST EN 61010-2-081:2015
EN 61010-2-081:2015 - 2 -
Foreword
The text of document 66/544/FDIS, future edition 2 of IEC 61010-2-081, prepared by
IEC/TC 66 "Safety of measuring, control and laboratory equipment" was submitted to the
IEC-CENELEC parallel vote and approved by CENELEC as EN 61010-2-081:2015.

The following dates are fixed:
(dop) 2015-11-27
• latest date by which the document has to be
implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2018-02-27
standards conflicting with the
document have to be withdrawn

This document supersedes EN 61010-2-081:2002.

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.

This standard
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.