Metal halide lamps - Performance specification

IEC 61167:2015 specifies the performance requirements for metal halide lamps for general lighting purposes. This third edition replaces the second edition published in 2011. This third edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. a) A set of new lamp data sheets (20 W, 35 W, 50 W, 100 W) is introduced. b) Reference to ILCOS (International lamp coding system) is removed from the lamp data sheets and now located in a new annex. c) Information on outer bulb temperature (and in some cases also on pin temperature and temperature adjacent to cap) is replaced with an explanation on differences in manufacturers' construction; this explanation is given in detail in a new annex.

Halogen-Metalldampflampen - Anforderungen an die Arbeitsweise

Lampes aux halogénures métalliques - Spécifications de performance

L'IEC 61167:2015 spécifie les exigences de performances relatives aux lampes aux halogénures métalliques pour l'éclairage à usage général. Cette troisième édition annule et remplace la deuxième édition parue en 2011. Cette édition constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente. a) Un jeu de nouvelles fiches techniques de lampes (20 W, 35 W, 50 W, 100 W) a été inséré. b) La référence à ILCOS (Système international de codification des lampes) a été retirée des fiches techniques de lampes et fait désormais l'objet d'une nouvelle annexe. c) Les informations sur la température de l'ampoule externe (et dans certains cas également sur la température de pincement et sur la température à proximité directe du culot) ont été remplacées par une explication sur les différences de construction entre les fabricants, cette explication étant détaillée dans une nouvelle annexe.

Sijalke s kovinskim halidom - Tehnične specifikacije (IEC 61167:2015)

Ta mednarodni standard določa zahteve glede zmogljivosti za sijalke s kovinskim halidom za splošno razsvetljavo.
Pri nekaterih zahtevah iz tega standarda je omenjen »tehnični list ustrezne sijalke«. Tehnični listi za nekatere sijalke so vključeni v ta standard. Ustrezne podatke za druge sijalke, ki sodijo v področje uporabe tega standarda, zagotovi njihov proizvajalec ali odgovorni prodajalec.
Zahteve iz tega standarda se nanašajo samo na tipsko preskušanje.
Zahteve in tolerance, ki jih dovoljuje standard, ustrezajo rezultatom tipskega preskušanja vzorca, ki ga proizvajalec predloži za ta namen. Ta vzorec naj bi načeloma vseboval enote z lastnostmi, ki so značilne za proizvajalčev izdelek, in katerih vrednosti so kar se da podobne srednjim vrednostim proizvedenih izdelkov.
S tolerancami, podanimi v standardu, se lahko pričakuje, da bo večina primerkov izdelka, ki je proizveden v skladu z vzorcem za tipsko preskušanje, skladna s standardom. Vendar zaradi razpršene proizvodnje ni mogoče zagotoviti, da bi bili vsi izdelki znotraj določenih toleranc. Za smernice glede načrtov vzorčenja in postopkov za kontrolo po opisnih spremenljivkah glejte standard IEC 60410.

General Information

Status
Withdrawn
Publication Date
09-Jun-2016
Withdrawal Date
09-Jun-2019
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
02-Nov-2021
Completion Date
02-Nov-2021

Relations

Buy Standard

Standard
EN 61167:2016
English language
218 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2016
1DGRPHãþD
SIST EN 61167:2011
6LMDONHVNRYLQVNLPKDOLGRP7HKQLþQHVSHFLILNDFLMH ,(&
Metal halide lamps - Performance specification (IEC 61167:2015)
Halogen-Metalldampflampen - Anforderungen an die Arbeitsweise
Lampes aux halogénures métalliques - Spécifications de performance
Ta slovenski standard je istoveten z: EN 61167:2016
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 61167
NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2016
ICS 29.140.30 Supersedes EN 61167:2011
English Version
Metal halide lamps - Performance specification
(IEC 61167:2015 , modified)
Lampes aux halogénures métalliques - Spécifications de Halogen-Metalldampflampen - Anforderungen an die
performance Arbeitsweise
(IEC 61167:2015 , modifiée) (IEC 61167:2015 , modifiziert)
This European Standard was approved by CENELEC on 2016-03-07. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61167:2016 E
European foreword
The text of document 34A/1809/FDIS, future edition 3 of IEC 61167, prepared by SC 34A “Lamps” of
IEC/TC 34 “Lamps and related equipment" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN 61167:2016.
A draft amendment, which covers common modifications to IEC 61167 (34A/1809/FDIS), was
prepared by CLC/TC 34A “Lamps” and approved by CENELEC.
The following dates are fixed:
• latest date by which the document has
(dop) 2016-12-10
to be implemented at national level by
publication of an identical
national standard or by endorsement
• latest date by which the national
(dow) 2019-06-10
standards conflicting with the document
have to be withdrawn
This document supersedes EN 61167:2011.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Clauses, subclauses, notes, tables, figures and annexes which are additional to those in
IEC 61167:2015 are prefixed “Z”.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association, and supports essential requirements of EU Directives.
For the relationship with EU Directives see informative Annexes ZZA, ZZB and ZZC, which are integral
parts of this document.
This standard provides test methods related to parameters as prescribed by EC Regulation 245/2009,
EU Regulation 1194/2012 and EU Regulation 874/2012 while conformity assessment (sampling,
conformity procedures as well as limits) for market surveillance are specified in the text of the above
Regulations.
Endorsement notice
The text of the International Standard IEC 61167:2015 was approved by CENELEC as a European
Standard with agreed common modifications.
COMMON MODIFICATIONS
CONTENTS Add the following annexes:
Annex ZA (normative) Normative references to international publications with
their corresponding European publications
Annex ZZA (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EC) No 245/2009
Annex ZZB (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EU) No 1194/2012
Annex ZZC (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EU) No 874/2012

Add the following clause before Clause 2:
Z1 Overall statement
Where a Commission Regulation specifies limits for parameters these limits shall be
used instead of the limits specified in this standard.
3 Terms and definitions
After 3.18 add new definitions 3.Z1 up to 3.Z7:
3.Z1
directional lamp
lamp having at least 80 % light output within a solid angle of π sr (corresponding to a
cone with angle of 120°)
[SOURCE: Regulation 1194/2012, Article 2]
3.Z2
beam angle
the angle between two imaginary lines in a plane through the optical beam axis, such
that these lines pass through the centre of the front face of the lamp and through
points at which the luminous intensity is 50 % of the centre beam intensity
[SOURCE: EN 61341]
3.Z3
partial luminous flux (of a light source, within a specified cone angle)
luminous flux emitted from a light source within a specified cone angle α determined
from the luminous intensity distribution I(θ, φ) of the source:
2π α / 2
= I(θ,ϕ)sinθdθdϕ (2)
α
∫ ∫
ϕ=0θ=0
Note 1 to entry: Partial luminous flux is expressed in lumen (lm).
Note 2 to entry: (θ, φ)=(0,0) is the direction of the cone axis.
Note 3 to entry: The cone angle α is the full angle (diameter) of the cone.
[SOURCE: EN 13032-4:2015, 3.41, modified, – Notes 4 and 5 removed]
Φ
3.Z4
useful luminous flux, Φuse
partial luminous flux of a lamp falling within the cone used for calculating the lamp’s
energy efficiency according Annex III, point 1.1 of regulation (EU) No 1194/2012
Note 1 to entry: Useful luminous flux is expressed in lumen (lm).
Note 2 to entry: The regulation specifies 90° or 120° cones according to the product characteristics.
Note 3 to entry: Useful luminous flux is similar to partial luminous flux. It is determined with the cone
axis coincident with the observed optical beam axis of the light source, the axis about which the luminous
intensity is substantially symmetrical.
3.Z5
efficacy
‘luminous efficacy of a source’, ‘light source efficacy’ or ‘lamp efficacy’
(ηsource)
the quotient of the luminous flux emitted (Ф) by the power consumed by the source
(Psource). ηsource = Ф / Psource. Unit: lm/W.
The power dissipated by auxiliary equipment such as ballasts is not included in the
power consumed by the source
[SOURCE: Regulation 245/2009 Annex II, 1.a)]
3.Z6
Lamp Lumen Maintenance Factor (LLMF)
the ratio of the luminous flux emitted by the lamp at a given time in its life to the initial
luminous flux
[SOURCE: Regulation 245/2009 Annex II, 1.b)]
3.Z7
Lamp Survival Factor (LSF)
the fraction of the total number of lamps which continue to operate at a given time
under defined conditions and switching frequency
[SOURCE: Regulation 245/2009 Annex II, 1.c)]
4 Lamp requirements
4.2 Marking
Add the following paragraph at the end of 4.2
Where a lamp is to be considered as a special purpose product according to
Regulation (EC) No 1194/2012 this shall be declared by the supplier.
4.8.4 Requirements and test conditions
Replace “Under consideration” with the following new text:
The chromaticity coordinates and correlated colour temperature of an individual lamp
shall be calculated according to CIE 15 from a measurement made under the
conditions of Annex B or Annex E as appropriate
The colour rendering index of an individual lamp shall be calculated according to
CIE 13.3 from a measurement made under the conditions of Annex B or Annex E as
appropriate.
4.Z1 After Subclause 4.7 add new Subclause 4.Z1 as follows:
4.Z1 Useful luminous flux
The useful luminous flux of a directional lamp shall be measured under the conditions
of Annex A or Annex E as appropriate, by luminous intensity integration as described
in EN 13032-4:2015 , 6.3 "Partial luminous flux".
Alternative measurement methods may be used if they can be shown to give
equivalent results for the product being tested, if necessary by applying correction
factors. Measurements with lamps operating horizontally are often much easier to
carry out. The reference method, however, uses the measurement position according
to A.1.
In case of doubt a goniophotometry measurement of EN 13032-4:2015, 6.3 shall be
used.
NOTE  Below are a few examples of alternative measurement methods. It is not an exhaustive list.
• For small beam angles shine into integrating sphere.
• Mount lamp on internal surface of integrating sphere.
• Mount lamp inside integrating sphere with screening (LM-20 technique).
• Illuminate a surface and measure the illuminance across the surface with a photometer.
• Illuminate a surface and measure the surface luminance with a luminance camera.
• Illuminate a translucent screen and measure the surface luminance of the rear side with a
luminance camera
4.Z2 After 4.9 add new Subclauses 4.Z2 up to 4.Z5 as follows:
4.Z2
The efficacy of an individual lamp shall be calculated from a measurement of luminous
flux and power according to the conditions of Annex B or Annex E as appropriate.
4.Z3
The lamp lumen maintenance factor of an individual lamp shall be calculated from
measurements of its luminous flux made at appropriate times according to the
conditions of Annex B or Annex E as appropriate. Lamp operation between these
measurements shall be as prescribed in Annex C.
4.Z4
The survival of an individual lamp shall be determined by operating lamps under the
conditions prescribed in Annex C until the lamp fails to remain alight or delivers low
light output (in case of doubt, low light output refers to noticeably less than 50 % of
rated light output).
4.Z5
The average mercury content shall be measured in accordance with the CV AAS
method as described in EN 62321-4.

Annex B (normative) Method of measuring electrical and photometrical characteristics
(lamps for operation on 50 Hz or 60 Hz supply frequencies
B.1 General
Replace the following paragraph in B.1
Photometric characteristics shall be measured in accordance with the relevant
recommendations of the CIE (Commission Internationale de l’Éclairage) 84. For
measurement for the centre beam intensity of reflector lamps, IEC/TR 61341 shall be
used.
By
Photometric characteristics shall be measured in accordance with EN 13032-1. For
determination of the centre beam intensity of reflector lamps, EN 61341 shall be used.
Annex E (normative) Method of measuring electrical and photometrical characteristics
on low frequency square wave reference ballast
E.1 Purpose of this annex
Replace the following paragraph in E.1
Photometric characteristics shall be measured in accordance with the relevant
recommendations of the CIE (Commission Internationale de l’Éclairage) 84. For
measurement for the centre beam intensity of reflector lamps, IEC/TR 61341 shall be
used.
By
Photometric characteristics shall be measured in accordance with EN 13032-1. For
determination of the centre beam intensity of reflector lamps, EN 61341 shall be used.
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu
Publication Year Title EN/HD Year
Light and lighting - Measurement and EN 13032-1 2004
presentation of photometric data of lamps +A1 2012
and luminaires -
Part 1: Measurement and file format
Light and lighting - Measurement and EN 13032-4 2015
presentation of photometric data of lamps
and luminaires -
Part 4: LED lamps, modules and
luminaires
IEC 60050-845 1987 International Electrotechnical Vocabulary - -
- Chapter 845: Lighting
IEC 60061-1 - Lamp caps and holders together with EN 60061-1 -
gauges for the control of
interchangeability and safety -
Part 1: Lamp caps
IEC 60598-1 - Luminaires - General requirements and EN 60598-1 -
tests
IEC 60923 - Auxiliaries for lamps - Ballasts for EN 60923 -
discharge lamps (excluding tubular
fluorescent lamps) - Performance
requirements
IEC 60927 - Auxiliaries for lamps - Starting devices EN 60927 -
(other than glow starters) - Performance
requirements
IEC/TR 61341 - Method of measurement of centre beam EN 61341 -
intensity and beam angle(s) of reflector
lamps
IEC 62035 - Discharge lamps (excluding fluorescent EN 62035 -
lamps) - Safety specifications
IEC 62321-4 Determination of certain substances in EN 62321-4
electrotechnical products -
Part 4: Mercury in polymers, metals
and electronics by CV-AAS, CV-AFS,
ICP-OES and ICP-MS
IEC 62471 - Photobiological safety of lamp and lamp EN 62471 -
systems
Publication Year Title EN/HD Year
...

Questions, Comments and Discussion