General Information

Abstract

IEC 60494-1:2013 specifies the general assembly characteristics which are to be applied to pantographs, to enable current collection from the overhead contact line system. It also specifies the tests the pantographs have to perform, excluding insulators. The main technical changes with regard to the previous edition are as follows: - simplification and standardization of the tolerances for static contact force; - definition of a new investigation test "Measurement of mean static contact force at ambient temperature"; - deletion of combined test "Total contact force"; - definition of a new combined test "Check of operating system at maximum speed"; - new Annex "Static contact force tolerances in Japan".

Status
Published
Publication Date
12-Sep-2013
Drafting Committee
MT 60494 - TC 9/MT 60494
Current Stage
PPUB - Publication issued
Start Date
13-Sep-2013
Completion Date
30-Sep-2013

Buy Documents

Standard

IEC 60494-1:2013 - Railway applications - Rolling stock - Pantographs - Characteristics and tests - Part 1: Pantographs for main line vehicles Released:9/13/2013

ISBN:978-2-8322-1091-8
English and French language (58 pages)
sale 15% off
Preview
sale 15% off
Preview

Overview

IEC 60494-1:2013 is an international standard developed by the International Electrotechnical Commission (IEC) specifically for railway applications concerning rolling stock pantographs. This part 1 standard focuses on pantographs designed for main line vehicles and outlines their essential characteristics and testing requirements. The standard ensures that pantographs provide reliable and efficient current collection from overhead contact line systems, maintaining safety and performance across various railway operations.

This edition introduces significant technical updates including simplified and standardized tolerances for static contact force, a new investigation test measuring mean static contact force at ambient temperature, and new combined tests like the check of the operating system at maximum speed. Additionally, it includes a specific annex addressing static contact force tolerances applicable in Japan.

Key Topics

  • General Assembly Characteristics: Specifies design criteria for pantographs ensuring compatibility and effective current collection from overhead lines without including insulators.

  • Static Contact Force: Defines tolerances and tests (including a new measurement at ambient temperature) critical for maintaining optimal contact pressure between pantograph and overhead wire.

  • Tests and Testing Regimens:

    • Type Tests assess conformity of pantograph design and components.
    • Routine Tests cover visual inspection, identification, and functional checks such as those of the Automatic Dropping Device (ADD).
    • Investigation Tests address detailed measurements like static contact force under ambient conditions.
    • Combined Tests verify system operation at maximum speed and overall current collection performance.
  • Mechanical and Operational Requirements:

    • Gauge specifications, extension capacity, transverse rigidity, mass, and roof force parameters.
    • Collector head dimensions, profile, and contact strip characteristics.
    • Automatic Dropping Device functionality and reliability.
  • Reliability and Maintenance Guidelines: Procedures to ensure pantograph durability and maintainability during service life.

  • Annexes:

    • Normative annexes covering static contact force tolerances and tests catalog.
    • Informative annexes detailing customer specification items and regional static force tolerances in Japan.

Applications

The IEC 60494-1:2013 standard applies primarily to main line railway vehicles equipped with pantographs for electric current collection. Its practical applications include:

  • Designing and manufacturing pantographs that meet international performance and safety expectations.
  • Performing standardized testing protocols for quality assurance before deployment or during maintenance cycles.
  • Supporting railway operators in maintaining consistent electrical contact integrity to optimize vehicle traction and reduce wear on overhead infrastructure.
  • Facilitating international rail equipment interoperability and compliance, particularly where differing force tolerances or environmental conditions must be accounted for (e.g., Japan-specific tolerances).
  • Aiding manufacturers and engineers to harmonize product design processes with the globally recognized IEC standards, enhancing market access and reliability.

Related Standards

IEC 60494-1:2013 is part of a broader series and related standards that cover railway pantographs and their components, including:

  • Other parts of IEC 60494 series addressing pantographs for different types of railway vehicles or additional technical aspects.
  • IEC standards on electrical equipment and systems for railways, such as those related to overhead contact lines and electrical safety.
  • Regional and national standards that may reference or align with IEC 60494-1 for pantograph testing and characteristics.
  • Standards addressing railway rolling stock interoperability and mechanical requirements, complementing the functional specifications of pantographs.

By adhering to IEC 60494-1:2013, railway stakeholders ensure pantograph designs meet rigorous international requirements, enhancing safety, operational stability, and longevity of electric traction systems. The standard’s comprehensive test methods and technical specifications make it an essential reference for manufacturers, operators, and maintenance teams in the global railway industry.

Relations

Effective Date
05-Sep-2023

Buy Documents

Standard

IEC 60494-1:2013 - Railway applications - Rolling stock - Pantographs - Characteristics and tests - Part 1: Pantographs for main line vehicles Released:9/13/2013

ISBN:978-2-8322-1091-8
English and French language (58 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

IRIS Certification (UNIFE)

International Railway Industry Standard certification.

BELAC Belgium Verified

TÜV SÜD Rail GmbH

TÜV SÜD railway certification services.

DAKKS Germany Verified

BSMI (Bureau of Standards, Metrology and Inspection)

Taiwan's standards and inspection authority.

TAF Taiwan Verified

Sponsored listings

Frequently Asked Questions

IEC 60494-1:2013 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Railway applications - Rolling stock - Pantographs - Characteristics and tests - Part 1: Pantographs for main line vehicles". This standard covers: IEC 60494-1:2013 specifies the general assembly characteristics which are to be applied to pantographs, to enable current collection from the overhead contact line system. It also specifies the tests the pantographs have to perform, excluding insulators. The main technical changes with regard to the previous edition are as follows: - simplification and standardization of the tolerances for static contact force; - definition of a new investigation test "Measurement of mean static contact force at ambient temperature"; - deletion of combined test "Total contact force"; - definition of a new combined test "Check of operating system at maximum speed"; - new Annex "Static contact force tolerances in Japan".

IEC 60494-1:2013 specifies the general assembly characteristics which are to be applied to pantographs, to enable current collection from the overhead contact line system. It also specifies the tests the pantographs have to perform, excluding insulators. The main technical changes with regard to the previous edition are as follows: - simplification and standardization of the tolerances for static contact force; - definition of a new investigation test "Measurement of mean static contact force at ambient temperature"; - deletion of combined test "Total contact force"; - definition of a new combined test "Check of operating system at maximum speed"; - new Annex "Static contact force tolerances in Japan".

IEC 60494-1:2013 is classified under the following ICS (International Classification for Standards) categories: 17.140.50 - Electroacoustics; 45.060.01 - Railway rolling stock in general. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 60494-1:2013 has the following relationships with other standards: It is inter standard links to IEC 60494-1:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 60494-1:2013 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


IEC 60494-1 ®
Edition 2.0 2013-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Railway applications – Rolling stock – Pantographs – Characteristics and tests –
Part 1: Pantographs for main line vehicles

Applications ferroviaires – Matériel roulant – Pantographes – Caractéristiques et
essais –
Partie 1: Pantographes pour véhicules grandes lignes

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni
utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les
microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.

Useful links:
IEC publications search - www.iec.ch/searchpub Electropedia - www.electropedia.org
The advanced search enables you to find IEC publications The world's leading online dictionary of electronic and
by a variety of criteria (reference number, text, technical electrical terms containing more than 30 000 terms and
committee,…). definitions in English and French, with equivalent terms in
It also gives information on projects, replaced and additional languages. Also known as the International
withdrawn publications. Electrotechnical Vocabulary (IEV) on-line.

IEC Just Published - webstore.iec.ch/justpublished Customer Service Centre - webstore.iec.ch/csc
Stay up to date on all new IEC publications. Just Published If you wish to give us your feedback on this publication
details all new publications released. Available on-line and or need further assistance, please contact the
also once a month by email. Customer Service Centre: csc@iec.ch.

A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.

Liens utiles:
Recherche de publications CEI - www.iec.ch/searchpub Electropedia - www.electropedia.org
La recherche avancée vous permet de trouver des Le premier dictionnaire en ligne au monde de termes
publications CEI en utilisant différents critères (numéro de électroniques et électriques. Il contient plus de 30 000
référence, texte, comité d’études,…). termes et définitions en anglais et en français, ainsi que
Elle donne aussi des informations sur les projets et les les termes équivalents dans les langues additionnelles.
publications remplacées ou retirées. Egalement appelé Vocabulaire Electrotechnique
International (VEI) en ligne.
Just Published CEI - webstore.iec.ch/justpublished
Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications de la CEI.
Just Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur
Disponible en ligne et aussi une fois par mois par email. cette publication ou si vous avez des questions
contactez-nous: csc@iec.ch.
IEC 60494-1 ®
Edition 2.0 2013-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Railway applications – Rolling stock – Pantographs – Characteristics and tests –

Part 1: Pantographs for main line vehicles

Applications ferroviaires – Matériel roulant – Pantographes – Caractéristiques et

essais –
Partie 1: Pantographes pour véhicules grandes lignes

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX U
ICS 45.060 ISBN 978-2-8322-1091-8

– 2 – 60494-1 © IEC:2013
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions, symbols and abbreviations . 8
3.1 General . 8
3.2 Design . 8
3.3 General characteristics . 10
3.4 Symbols and abbreviations . 10
4 Technical requirements . 11
4.1 General . 11
4.2 Gauge . 11
4.3 Extension of the pantograph . 11
4.4 Electrical values . 11
4.5 Force requirements . 11
4.6 Transverse rigidity . 11
4.7 Collector head . 12
4.7.1 Length . 12
4.7.2 Width . 12
4.7.3 Head profiles . 12
4.7.4 Contact strips . 12
4.8 Operating system . 12
4.9 Automatic dropping device (ADD) . 12
4.10 Pantograph mass and force on the roof . 13
4.11 Protection against corrosion . 13
5 Marking . 13
6 Tests . 13
6.1 Categories of tests . 13
6.1.1 Overview . 13
6.1.2 Type tests . 13
6.1.3 Routine tests . 14
6.1.4 Investigation tests . 14
6.1.5 Combined tests . 14
6.2 General tests . 14
6.2.1 Visual inspection (routine test). 14
6.2.2 Weighing (type test) . 14
6.2.3 Dimensions. 14
6.2.4 Identification (routine test) . 15
6.2.5 Functional check of ADD (type test) . 15
6.2.6 Functional check of ADD (routine test) . 15
6.3 Operating tests . 15
6.3.1 Measurement of static contact force at ambient temperature (routine

test) . 15
6.3.2 Checking of the operating system of the pantograph (routine test) . 16
6.3.3 Operating climatic tests (type test) . 16
6.3.4 Measurement of mean static contact force at ambient temperature
(investigation test) . 16

60494-1 © IEC:2013 – 3 –
6.4 Endurance tests . 16
6.4.1 Raising/lowering operations (type test) . 16
6.4.2 Collector head suspension (type test) . 17
6.4.3 Resistance to vibrations . 17
6.5 Resistance to shocks (supplementary type test) . 18
6.6 Transverse rigidity test (type test) . 19
6.7 Air tightness tests . 19
6.7.1 General . 19
6.7.2 Air tightness tests on pantograph mounted pneumatic equipment
(routine test) . 19
6.7.3 Air tightness climatic test (type test) . 20
6.8 Measurement of degrees of freedom of collector head (routine test) . 20
6.9 Measurement of housing force (type test) . 20
6.10 Total mean uplift force (combined test) . 20
6.11 Current collection tests (combined test) . 21
6.12 Current heating tests . 21
6.12.1 Heating tests: rated and maximum current, vehicle at standstill
(supplementary type test) . 21
6.12.2 Heating test: simulation of running vehicle (supplementary type test) . 21
6.12.3 Field test (combined test) . 21
6.13 Check of operating system at maximum speed (combined test) . 22
7 Inspection plan . 22
8 Reliability . 22
8.1 General . 22
8.2 Specification. 22
8.3 In-service reliability demonstration . 23
9 Maintenance . 23
9.1 Structure . 23
9.2 Collector head structure . 23
9.3 Maintainability . 23
Annex A (normative) Static contact force tolerances . 24
Annex B (normative) List of tests . 25
Annex C (informative) Items to be specified in customer specification . 27
Annex D (informative) Static contact force tolerances in Japan . 28
Bibliography . 29

Figure 1 – Pantograph terminology . 9
Figure 2 – Test principle . 19
Figure A.1 – Static contact force tolerances (grey area) . 24

Table 1 – Design definitions . 8
Table B.1 – Catalogue of tests . 25
Table D.1 – Static contact force tolerances in Japan . 28

– 4 – 60494-1 © IEC:2013
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RAILWAY APPLICATIONS –
ROLLING STOCK – PANTOGRAPHS –
CHARACTERISTICS AND TESTS –
Part 1: Pantographs for main line vehicles

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard 60494-1 has been prepared by IEC technical committee 9: Electrical
equipment and systems for railways.
This standard is based on EN 50206-1.
This second edition cancels and replaces the first edition issued in 2002 and constitutes a
technical revision.
The main technical changes with regard to the previous edition are as follows:
– simplification and standardization of the tolerances for static contact force (Annexes A
and B);
– definition of a new investigation test "Measurement of mean static contact force at ambient
temperature" (6.3.4);
– deletion of combined test "Total contact force" (6.11);

60494-1 © IEC:2013 – 5 –
– definition of a new combined test "Check of operating system at maximum speed" (6.13);
– adjustment of terms (static contact force instead of static force);
– deletion of Clause 10;
– new Annex D " Static contact force tolerances in Japan ".
The text of this standard is based on the following documents:
FDIS Report on voting
9/1821/FDIS 9/1845/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 60494 series, published under the general title Railway
applications – Rolling stock – Pantographs – Characteristics and tests, can be found on the
IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
– 6 – 60494-1 © IEC:2013
INTRODUCTION
The electrical power supply of a tractive unit is achieved by the collection of current from one
or more contact wires by means of one or more pantograph(s), installed on the traction unit or
on the trainset's vehicle.
The contact strips of the pantograph which slide along the contact wire facilitate the
transmission of power.
The pantograph and the overhead contact line system form two oscillating sub-systems which
can be displaced. There exists a unilateral sliding linkage between them, which shall ensure
continuous contact. Their design shall allow for minimum wear of both sub-systems when
used.
60494-1 © IEC:2013 – 7 –
RAILWAY APPLICATIONS –
ROLLING STOCK – PANTOGRAPHS –
CHARACTERISTICS AND TESTS –
Part 1: Pantographs for main line vehicles

1 Scope
This part of IEC 60494 specifies the general assembly characteristics which are to be applied
to pantographs, to enable current collection from the overhead contact line system. It also
specifies the tests the pantographs have to perform, excluding insulators.
This Standard is not applicable to pantograph dielectric tests, which are to be performed on
the pantograph installed on the vehicle roof. If no other requirement is agreed between
customer and supplier, insulation coordination according to IEC 62497-1 may be used.
This Standard is not applicable to pantographs used on isolated metros and light rail systems.
These pantographs are considered in IEC 60494-2.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60077 (all parts), Railway applications – Electric equipment for rolling stock
IEC 60850, Railway applications – Supply voltages of traction systems
IEC 60913:2013, Railway applications – Fixed installations – Electric traction overhead
contact lines
IEC 61373, Railway applications – Rolling stock equipment – Shock and vibration tests
IEC 62278 (all parts), Railway applications – Specification and demonstration of reliability,
availability, maintainability and safety (RAMS)
IEC 62486, Railway applications – Current collection systems – Technical criteria for the
interaction between pantograph and overhead line (to achieve free access)
IEC 62498-1, Railway applications – Environmental conditions for equipment – Part 1:
Equipment on board rolling stock
IEC 62499, Railway applications – Current collection systems – Pantographs, testing methods
for carbon contact strips
– 8 – 60494-1 © IEC:2013
EN 50317, Railway applications – Current collection systems – Requirements for and
validation of measurements of the dynamic interaction between pantograph and overhead
contact line
3 Terms and definitions, symbols and abbreviations
For the purposes of this document, the following terms and definitions apply.
3.1 General
3.1.1
supplier
manufacturer of the pantograph
3.1.2
customer
either operating authority or vehicle manufacturer
3.1.3
pantograph (see Figure 1)
apparatus for collecting current from one or more contact wires, formed of a hinged device
designed to allow vertical movement of the pantograph head
[IEC 60050-811:1991, 811-32-02]
3.2 Design
Table 1 – Design definitions
Def. Term Item Definition
No. No.
frame 1 articulated structure which enables the collector head to move in a
3.2.1
vertical direction with respect to the base frame of the pantograph
base frame 2 fixed part of the pantograph which supports the frame and is mounted
3.2.2
on insulators fixed to the vehicle roof
collector head 3 part of the pantograph supported by the frame which includes contact
3.2.3
strips, horns and may include a suspension
contact strip 4 replaceable wearing part of the collector head which interfaces with
3.2.4
the overhead contact line system
horns 5 ends of the collector head which ensure smooth engagement with the
3.2.5
contact wire
collector head length 6 dimension of collector head measured transversely in the horizontal
3.2.6
plane in relation to the vehicle
collector head width 7 maximum distance measured along the axis of the track between the
3.2.7
outer edges of the contact strips
collector head height 8 vertical distance between the lowest point of the horns and the
3.2.8
uppermost point of the contact strips
collector head pivot 9 pitching axis of the collector head
3.2.9
length of contact strips 10 total length of wearable material intended for normal interaction
3.2.10
measured transversely in relation to the vehicle
_____________
EN 50317 is under consideration at the IEC and will be published as IEC 62846.

60494-1 © IEC:2013 – 9 –
Def. Term Item Definition
No. No.
height at "lower 11 vertical distance between the pantograph mounting plane on the top of
3.2.11
operating position" insulators and the upper surface of contact strips, the pantograph
being raised to the lowest level at which it is designed to collect
current
height at "upper 12 vertical distance between the pantograph mounting plane on the top of
3.2.12
operating position" insulators and the upper surface of the contact strips, the pantograph
being raised to the highest level at which it is designed to collect
current
working range 13 difference between the "upper operating position" height and the
3.2.13
"lower operating position" height
housed height 14 vertical distance between the pantograph mounting plane on the top of
3.2.14
insulators and the upper surface of the contact strips or any other part
of the pantograph structure if higher (pantograph being in the housed
position)
pantograph "electrical 15 vertical distance between the highest live part and the lowest live part
3.2.15
thickness" of the pantograph at housed position
operating system 16 device which provides a force to raise or to lower the pantograph
3.2.16
maximum extension 17 maximum extended height to mechanical stops (vertical distance
3.2.17
between the pantograph mounting plane on the top of insulators and
the upper surface of contact strips, without any device which will limit
the pantograph extension within the working range)
limited maximum 18 reduced extension allowed by intermediate mechanical stops (vertical
3.2.18
extension distance between the pantograph mounting plane on the top of
insulators and the upper surface of contact strips)
19 Device that lowers the pantograph in the event of pantograph head
3.2.19 Automatic dropping
failure or damage of the pantograph head.
device
NOTE The definitions are related to Figure 1, except items 9, 15, 16, 17, 18, and 19.

4 3
13 8
IEC  2234/13
NOTE The sketch in Figure 1 is an example only and does not exclude other types of pantographs (diamond type,
for example).
Figure 1 – Pantograph terminology

– 10 – 60494-1 © IEC:2013
3.3 General characteristics
3.3.1
rated voltage
voltage at which the pantograph is designed to function
3.3.2
rated current, vehicle at standstill
average value of that current withstood for 30 min by the pantograph at standstill
3.3.3
maximum current, vehicle at standstill
maximum value of that current withstood by the pantograph at standstill for a given time
3.3.4
rated current, vehicle running
continuous current transfer capacity of the pantograph
3.3.5
static contact force
vertical force exerted upward by the collector head on the overhead contact line system at
standstill
3.3.6
nominal static contact force
specified set point for the static contact force
3.3.7
mean static contact force
average of the actual values of static contact forces
Note 1 to entry: evaluated as follows: the static contact forces are measured continually within the working range
during raising (F ) and lowering (F ) operation. By convention, the mean static contact force at any point is equal
r l
F+F
r l
to
.
3.3.8
target static contact force
upward force measured at the standard working height of the pantograph when the
pantograph is raised at 0,05 m/s under the same conditions as in actual use
3.3.9
total mean uplift force
vertical force measured at the collector head, the latter not touching the contact wire
Note 1 to entry: It is equal to the sum of static contact force and the aerodynamic force caused by the air at the
considered speed for a given collector height, the results being referred to zero ambient wind conditions.
3.3.10
total contact force
total force between collector head and contact wire while running
3.3.11
housing force
force applied vertically to the collector head to maintain the whole pantograph in housed
position
3.4 Symbols and abbreviations
AC Alternating current
60494-1 © IEC:2013 – 11 –
ADD Automatic dropping device
DC Direct current
F Natural transverse frequency
F Force during raising the pantograph
r
F Force during lowering the pantograph
l
MDBF Mean distance between failure
Γ Acceleration at collector head pivot
4 Technical requirements
4.1 General
All general characteristics are given in the customer specifications. Unless otherwise
specified, environmental conditions are defined in IEC 62498-1. The category of environment
has to be specified by the customer.
4.2 Gauge
The pantograph, at housed position and operating position, shall comply with the gauge
specified in the customer specifications or shall be in accordance with IEC 62486.
4.3 Extension of the pantograph
The customer specifications shall state the values in relationship with items 10 to 13 in
Table 1. In the absence of specifications in the tender documents, when the pantograph is
raising or lowering, the collector head trajectory over the working range shall be within a
range of ± 50 mm in the longitudinal direction, and ± 10 mm in the lateral direction in relation
to the vertical line.
4.4 Electrical values
The supply voltages of traction systems are specified in IEC 60850.
The customer specifications shall also state the duration and values of the exceptional
voltages for operating pantographs and housed pantographs.
Values defined in 3.3.2 to 3.3.4 shall be given in the customer specifications.
4.5 Force requirements
Unless larger tolerances are agreed between user and supplier, static contact forces
measured during raising and lowering shall lie within the boundaries defined in Annex A.
Operating requirements for static contact force, total mean uplift force and total contact force
shall follow the requirements in IEC 62486 if not specified in the customer specifications.
4.6 Transverse rigidity
When a transverse force is exerted on the part of the frame which supports the collector head
at the upper operating position, the deflection shall not exceed the value defined in 6.6 and no
permanent deformation shall occur.

– 12 – 60494-1 © IEC:2013
4.7 Collector head
4.7.1 Length
If not specified in the customer specification, lengths defined in IEC 62486 shall be used.
4.7.2 Width
The collector head width shall be defined according to the type of suspension, the number of
wear strips and the system characteristics of the overhead contact line system.
4.7.3 Head profiles
If not specified in the customer specification, the collector head outline profiles and maximum
allowable tilt defined in IEC 62486 shall be used.
4.7.4 Contact strips
When not specified in IEC 62486 wear strip material, maximum current at standstill and under
running conditions shall be specified in the customer specifications. If applicable, testing
methods according to IEC 62499 are recommended.
4.8 Operating system
The installation and the definition of the operating system shall be provided by the supplier.
If not specified by the customer, the operating system shall be designed to ensure, at
standstill and up to the maximum speed of the traction unit, a break from the contact wire,
within 3 s, over the minimum insulation distance.
The housing force shall prevent the pantograph from raising from the housed position at all
speeds up to maximum speed of the vehicle.
The housing force may be agreed between the customer and the supplier. Alternatively,
provision may be made for the fitting of a holding down device.
4.9 Automatic dropping device (ADD)
The automatic dropping device has to be mounted only when the customer so requires.
Impact or damage occurring to contact strips liable to cause subsequent damage to overhead
contact line system shall be detected by ADD. Impacts or damages to other parts of the
collector head like horns can be included in the ADD, if specified by the customer.
When designing, the following characteristics shall be taken into account:
• ADD reaction time;
• ADD failure to safe condition;
• ADD self-test in workshop;
• ADD reliability;
• pantograph integrity after work of ADD.
The ADD system shall be designed to ensure that minor damage to the contact strips as may
be experienced in daily service shall not cause operation of ADD system.
The ADD shall not cause additional damage to the pantograph.

60494-1 © IEC:2013 – 13 –
4.10 Pantograph mass and force on the roof
The supplier shall specify the mass of the pantograph with or without insulators and the
maximum force at every fixing point. In addition the supplier shall specify all relevant
parameters to enable the calculation of the maximum efforts at every fixing point.
4.11 Protection against corrosion
The specifications regarding the application requirements and type of corrosion protection
shall be given in the customer specifications.
5 Marking
As a minimum the following shall be labelled on the pantograph:
• manufacturer's name;
• pantograph serial number;
• type of pantograph;
• month and year of production.
6 Tests
6.1 Categories of tests
6.1.1 Overview
There are four categories of tests:
• type tests;
• routine tests;
• investigation tests;
• combined tests.
The above tests are described in 6.1.2 to 6.1.5.
Annex B summarises the tests which shall be performed.
6.1.2 Type tests
This International Standard distinguishes the basic model of a pantograph from the derived
model of the same pantograph. The derived model can incorporate modifications to the basic
design which shall be considered to be covered by the existing relevant type tests. This is
provided that any such changes can be demonstrated to be at least equal to the basic design
through calculation or operational experience of at least two years on operational lines, and
with technical requirements at least equal to those for which the basic model was designed.
Type tests shall be performed on a single piece of apparatus of a given design.
Equipment in current manufacture shall be considered to have satisfied the type tests and
shall be exempted from them, if the manufacturer provides signed reports of type tests
already made on identical apparatus constructed previously.
Supplementary type tests shall be required if they are requested in the customer specification
and after agreement with the supplier.

– 14 – 60494-1 © IEC:2013
6.1.3 Routine tests
Routine tests shall be carried out to verify that the properties of a product correspond to those
measured during the type test. Routine tests shall be performed by the supplier on each
equipment. For certain apparatus, after agreement between customer and supplier, routine
tests may be replaced by sampling tests (tests performed on a number of apparatus taken at
random from a batch).
6.1.4 Investigation tests
Investigation tests are special tests, which are supplementary, and performed on a single item
in order to obtain additional information. They are required only if they are specified in the
customer specifications.
The acceptance of the apparatus shall not rely on the results of those investigation tests.
6.1.5 Combined tests
Combined tests are special and supplementary tests which can only be carried out in an
operating environment. They shall take into account the type of vehicle to be used, its speed
and direction of travel. They shall be carried out using the track and/or overhead contact line
system defined in the customer specifications.
These tests apply to both basic and derived pantograph models.
6.2 General tests
6.2.1 Visual inspection (routine test)
The pantograph shall be completely assembled.
Test acceptance criteria:
The pantograph shall include all electrical and mechanical components, shall be free from
physical defects and surface treatments shall have been carried out (see 4.11).
6.2.2 Weighing (type test)
The pantograph shall be completely assembled.
Test acceptance criteria:
The mass of the pantograph shall comply with the contractual mass as specified in 4.10.
6.2.3 Dimensions
The dimensions of pantograph (including tolerances), as specified on the drawings, shall be
verified with appropriate measurement devices.
As a minimum, the following measurements shall be carried out:
• collector head length (routine test);
• collector head height (routine test);
• collector head width (type test);
• head profile (type test);
• length of contact strips (type test);

60494-1 © IEC:2013 – 15 –
• housed height (routine test);
• maximum extension (routine test);
• limited maximum extension (routine test);
• electrical thickness (routine test);
• distance between mounting points (routine test).
Test acceptance criteria:
The dimensions shall be within the tolerances specified on the drawings.
6.2.4 Identification (routine test)
Test acceptance criteria:
The marking shall comply with the requirements described in Clause 5.
6.2.5 Functional check of ADD (type test)
The test shall be performed for two extensions of the pantograph:
• upper operating position;
• 20 % of the working range above housed position.
After the pantograph is raised to the considered extension, the ADD shall be released by
simulating damage. The simulation shall be carried out with the same physical signal as in
real operation. The reaction time shall be measured from generating the signal to 20 cm
below the considered extension.
Test acceptance criteria:
The reaction time shall be less or equal to 1 s. There shall be no damage on the pantograph
structure.
6.2.6 Functional check of ADD (routine test)
The pantograph shall be raised to the extensions described in 6.2.5 and then the ADD shall
be released by simulating a damage.
Test acceptance criteria:
The ADD shall operate.
6.3 Operating tests
6.3.1 Measurement of static contact force at ambient temperature (routine test)
If a damper is fitted, this shall be disconnected.
The static contact force shall be measured between upper and lower operating position
directly under the collector head suspension during a continuous cycle of raising and lowering,
at a speed of 0,05 m/s ± 10 %.
The measuring device, which shall include load measuring, signal processing and data
logging shall have a system accuracy better than 3 %.
Test acceptance criteria:
– 16 – 60494-1 © IEC:2013
The measured forces shall comply with 4.5.
6.3.2 Checking of the operating system of the pantograph (routine test)
The pantograph shall be coupled to the whole operating system. The test shall be carried out
at ambient temperature and at rated air supply pressure or rated voltage in the case of
electrical operating system.
Test acceptance criteria:
A smooth, steady rise to maximum working height shall be attained free from shocks liable to
cause damage.
The rise from housed height to maximum working height shall be achieved in a time not
exceeding 10 s from the moment the pantograph starts to rise.
The lowering movement from any height in the working range shall operate with a rapid
commencement.
The lowering action shall be free from shocks liable to cause damage.
The lowering of the pantograph from maximum working height shall be achieved in a time not
exceeding 10 s from the moment the pantograph starts to lower.
6.3.3 Operating climatic tests (type test)
The tests as described in 6.3.2 shall be carried out at the extremes of temperature and
humidity specified in the customer specifications. If the values are not specified, the tests
shall be carried out at –25 °C and +40 °C, ambient humidity.
The above tests, at the extremes of temperature shall also be carried out at the minimum and
maximum values of air pressure or voltage specified in the customer specifications.
Test acceptance criteria:
During and after the tests, the pantograph shall operate satisfactorily in accordance with the
acceptance criteria given in 6.3.2.
6.3.4 Measurement of mean static contact force at ambient temperature
(investigation test)
If a damper is fitted, the test described in 6.3.1 shall be repeated with the damper in place.
6.4 Endurance tests
6.4.1 Raising/lowering operations (type test)
6.4.1.1 Operation between housed position and upper operating position
The pantograph fitted with a collector head which has the largest mass designed for that
pantograph, shall be submitted to 10 000 raising and lowering consecutive operations from
housed position up to upper operating position. For the first 500 and last 500 operations, the
pantograph shall raise to the maximum extension while the operating system energy (air or
electricity) supply is at the minimum value indicated in IEC 60077 series. If the customer
specification requires a different number of operations, then the test and the acceptance
requirement shall be the subject of agreement between customer and supplier.
NOTE The number of 10 000 was derived from assumptions about average figures of life time, days of operation
per year and number of raising and lowering operations per day.

60494-1 © IEC:2013 – 17 –
Test acceptance criteria:
After the test, all parameters shall be adjusted to the nominal values.
There shall be no abnormal wear. The pantograph shall meet the requirements of 6.3.1 and
6.3.2.
There shall be no distortions or fractures.
6.4.1.2 Operation within working range
The pantograph with a collector head in the same conditions as described in 6.4.1.1 shall be
submitted to 75 000 raising and lowering consecutive operations within the working range at a
speed of 0,1 m/s (if damper is fitted this shall be disconnected).
NOTE The number of 75 000 was
...