ISO 4064-2:2001
(Main)Measurement of water flow in closed conduits — Meters for cold potable water — Part 2: Installation requirements and selection
Measurement of water flow in closed conduits — Meters for cold potable water — Part 2: Installation requirements and selection
Mesurage de débit d'eau dans les conduites fermées — Compteurs d'eau potable froide — Partie 2: Conditions d'installation et choix
Merjenje pretoka vode v zaprtih vodih - Merila za hladno vodo - 2. del: Zahteve za vgradnjo in izbira
General Information
Relations
Buy Standard
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 4064-2
Second edition
2001-06-01
Measurement of water flow in closed
conduits — Meters for cold potable water —
Part 2:
Installation requirements and selection
Mesurage de débit d'eau dans les conduites fermées — Compteurs d'eau
potable froide —
Partie 2: Conditions d'installation et choix
Reference number
ISO 4064-2:2001(E)
©
ISO 2001
---------------------- Page: 1 ----------------------
ISO 4064-2:2001(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall not
be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this
file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat accepts no liability in this
area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters
were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event
that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2001
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic
or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's member body
in the country of the requester.
ISO copyright office
Case postale 56 � CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.ch
Web www.iso.ch
Printed in Switzerland
ii © ISO 2001 – All rights reserved
---------------------- Page: 2 ----------------------
ISO 4064-2:2001(E)
Contents Page
Foreword.iv
1 Scope .1
2 Normative reference .1
3 Terms and definitions .1
4 Examples of use of meters operating in parallel and multiple meter operation .2
5 Criteria for the selection of water meters.2
5.1 General considerations.2
5.2 Meters operating in parallel or in group.2
6 Associated fittings.3
6.1 Upstream side .3
6.2 Downstream side .3
6.3 Meters operating in parallel or in groups.3
7 Installation.3
7.1 General requirements.3
7.2 Installation requirements .4
7.3 Meters operating in parallel or in group.4
8 Special requirements governing the installation of Woltmann meters and single jet meters .5
8.1 General considerations.5
8.2 Types of disturbance.5
8.3 Methods to eliminate disturbances.5
9 First operation of new or repaired water meters.6
9.1 General considerations.6
9.2 Meters operating in parallel or in group.6
Bibliography.7
© ISO 2001 – All rights reserved iii
---------------------- Page: 3 ----------------------
ISO 4064-2:2001(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
member bodies). The work of preparing International Standards is normally carried out through ISO technical
committees. Each member body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, governmental and non-governmental, in
liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 3.
Draft International Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this part of ISO 4064 may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
International Standard ISO 4064-2 was prepared by Technical Committee ISO/TC 30, Measurement of fluid flow in
closed conduits, Subcommittee SC 7, Volume methods including water meters.
This second edition cancels and replaces the first edition (ISO 4064-2:1978) which has been technically revised.
ISO 4064 consists of the following parts, under the general title Measurement of water flow in closed conduits —
Meters for cold potable water:
� Part 1: Specifications
� Part 2: Installation requirements and selection
� Part 3: Test methods and equipment
iv © ISO 2001 – All rights reserved
---------------------- Page: 4 ----------------------
INTERNATIONAL STANDARD ISO 4064-2:2001(E)
Measurement of water flow in closed conduits — Meters for cold
potable water —
Part 2:
Installation requirements and selection
1 Scope
This part of ISO 4064 specifies criteria for the selection of water meters, associated fittings, installation, special
requirements for some meters and the first operation of new or repaired meters to ensure accurate constant
measurement and reliable reading of the meter.
This part of ISO 4064 deals only with single water meter installations and is also applicable to single meters
operating either in parallel or grouped together in one location. It is not applicable to “combination” meters, for
which specifications are given in ISO 7858-1.
Where legal national requirements exist, they will in all cases take precedence over the specifications in this part of
ISO 4064.
ISO 4064-1 deals with terminology, technical and dimensional characteristics, metrological characteristics and
pressure loss.
ISO 4064-3 deals with test methods and equipment.
2 Normative reference
The following normative document contains provisions which, through reference in this text, constitute provisions of
this part of ISO 4064. For dated references, subsequent amendments to, or revisions of, any of these publications
do not apply. However, parties to agreements based on this part of ISO 4064 are encouraged to investigate the
possibility of applying the most recent editions of the normative documents indicated below. For undated
references, the latest edition of the normative document referred to applies. Members of IEC and ISO maintain
registers of currently valid International Standards.
ISO 4064-1:1993, Measurement of water flow in closed conduits — Meters for cold potable water — Part 1:
Specifications.
3 Terms and definitions
For the purposes of this part of ISO 4064, the following terms and definitions apply.
3.1
parallel operation
operation of two or more meters grouped together and connected to a common source and a common delivery
© ISO 2001 – All rights reserved 1
---------------------- Page: 5 ----------------------
ISO 4064-2:2001(E)
3.2
multiple meter operation
operation of several meters grouped together where their inlets are connected to a common source, or their outlets
to a common delivery, but not both at same time
4 Examples of use of meters operating in parallel and multiple meter operation
Water meters may be operated in parallel where the installation of one large meter to meet the maximum water
demand or to cover the required flowrate range is impractical.
Water meters may be installed in parallel where “stand by” meters are necessary to ensure continuity of delivery
and flow measurement in the case of filter blockage or water meter breakdown.
Meters are grouped in multiple operation for ease of access, service and reading, where it is necessary to split a
water supply into a number of branches, e.g. in a block of flats, or where it is necessary to unite a number of
metered tributary flows into a common main, as in a water treatment plant.
5 Criteria for the selection of water meters
5.1 General considerations
The type, metrological class and sizes of water meters are determined according to the operating conditions of the
installation, particularly taking into account the following:
� the available supply pressure;
� physical and chemical characteristics of the water;
� acceptable pressure loss across the meter;
� the expected flowrates: the flowrates q , q , q of the meter (as defined in clause 3 of ISO 4064-1:1993) shall
min p s
be
...
SLOVENSKI STANDARD
SIST ISO 4064-2:2002
01-junij-2002
Merjenje pretoka vode v zaprtih vodih - Merila za hladno vodo - 2. del: Zahteve za
vgradnjo in izbira
Measurement of water flow in closed conduits -- Meters for cold potable water -- Part 2:
Installation requirements and selection
Mesurage de débit d'eau dans les conduites fermées -- Compteurs d'eau potable froide -
- Partie 2: Conditions d'installation et choix
Ta slovenski standard je istoveten z: ISO 4064-2:2001
ICS:
91.140.60 Sistemi za oskrbo z vodo Water supply systems
SIST ISO 4064-2:2002 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST ISO 4064-2:2002
---------------------- Page: 2 ----------------------
SIST ISO 4064-2:2002
INTERNATIONAL ISO
STANDARD 4064-2
Second edition
2001-06-01
Measurement of water flow in closed
conduits — Meters for cold potable water —
Part 2:
Installation requirements and selection
Mesurage de débit d'eau dans les conduites fermées — Compteurs d'eau
potable froide —
Partie 2: Conditions d'installation et choix
Reference number
ISO 4064-2:2001(E)
©
ISO 2001
---------------------- Page: 3 ----------------------
SIST ISO 4064-2:2002
ISO 4064-2:2001(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall not
be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this
file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat accepts no liability in this
area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters
were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event
that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2001
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic
or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's member body
in the country of the requester.
ISO copyright office
Case postale 56 � CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.ch
Web www.iso.ch
Printed in Switzerland
ii © ISO 2001 – All rights reserved
---------------------- Page: 4 ----------------------
SIST ISO 4064-2:2002
ISO 4064-2:2001(E)
Contents Page
Foreword.iv
1 Scope .1
2 Normative reference .1
3 Terms and definitions .1
4 Examples of use of meters operating in parallel and multiple meter operation .2
5 Criteria for the selection of water meters.2
5.1 General considerations.2
5.2 Meters operating in parallel or in group.2
6 Associated fittings.3
6.1 Upstream side .3
6.2 Downstream side .3
6.3 Meters operating in parallel or in groups.3
7 Installation.3
7.1 General requirements.3
7.2 Installation requirements .4
7.3 Meters operating in parallel or in group.4
8 Special requirements governing the installation of Woltmann meters and single jet meters .5
8.1 General considerations.5
8.2 Types of disturbance.5
8.3 Methods to eliminate disturbances.5
9 First operation of new or repaired water meters.6
9.1 General considerations.6
9.2 Meters operating in parallel or in group.6
Bibliography.7
© ISO 2001 – All rights reserved iii
---------------------- Page: 5 ----------------------
SIST ISO 4064-2:2002
ISO 4064-2:2001(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
member bodies). The work of preparing International Standards is normally carried out through ISO technical
committees. Each member body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, governmental and non-governmental, in
liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 3.
Draft International Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this part of ISO 4064 may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
International Standard ISO 4064-2 was prepared by Technical Committee ISO/TC 30, Measurement of fluid flow in
closed conduits, Subcommittee SC 7, Volume methods including water meters.
This second edition cancels and replaces the first edition (ISO 4064-2:1978) which has been technically revised.
ISO 4064 consists of the following parts, under the general title Measurement of water flow in closed conduits —
Meters for cold potable water:
� Part 1: Specifications
� Part 2: Installation requirements and selection
� Part 3: Test methods and equipment
iv © ISO 2001 – All rights reserved
---------------------- Page: 6 ----------------------
SIST ISO 4064-2:2002
INTERNATIONAL STANDARD ISO 4064-2:2001(E)
Measurement of water flow in closed conduits — Meters for cold
potable water —
Part 2:
Installation requirements and selection
1 Scope
This part of ISO 4064 specifies criteria for the selection of water meters, associated fittings, installation, special
requirements for some meters and the first operation of new or repaired meters to ensure accurate constant
measurement and reliable reading of the meter.
This part of ISO 4064 deals only with single water meter installations and is also applicable to single meters
operating either in parallel or grouped together in one location. It is not applicable to “combination” meters, for
which specifications are given in ISO 7858-1.
Where legal national requirements exist, they will in all cases take precedence over the specifications in this part of
ISO 4064.
ISO 4064-1 deals with terminology, technical and dimensional characteristics, metrological characteristics and
pressure loss.
ISO 4064-3 deals with test methods and equipment.
2 Normative reference
The following normative document contains provisions which, through reference in this text, constitute provisions of
this part of ISO 4064. For dated references, subsequent amendments to, or revisions of, any of these publications
do not apply. However, parties to agreements based on this part of ISO 4064 are encouraged to investigate the
possibility of applying the most recent editions of the normative documents indicated below. For undated
references, the latest edition of the normative document referred to applies. Members of IEC and ISO maintain
registers of currently valid International Standards.
ISO 4064-1:1993, Measurement of water flow in closed conduits — Meters for cold potable water — Part 1:
Specifications.
3 Terms and definitions
For the purposes of this part of ISO 4064, the following terms and definitions apply.
3.1
parallel operation
operation of two or more meters grouped together and connected to a common source and a common delivery
© ISO 2001 – All rights reserved 1
---------------------- Page: 7 ----------------------
SIST ISO 4064-2:2002
ISO 4064-2:2001(E)
3.2
multiple meter operation
operation of several meters grouped together where their inlets are connected to a common source, or their outlets
to a common delivery, but not both at same time
4 Examples of use of meters operating in parallel and multiple meter operation
Water meters may be operated in parallel where the installation of one large meter to meet the maximum water
demand or to cover the required flowrate range is impractical.
Water meters may be installed in parallel where “stand by” meters are necessary to ensure continuity of delivery
and flow measurement in the case of filter blockage or water meter breakdown.
Meters are grouped in multiple operation for ease of access, service and reading, where it is necessary to split a
water supply into a number of branches, e.g. in a block of flats, or where it is necessary to unite a number of
metered tributary flows into a common main, as in a water treatment plant.
5 Criteria for the
...
NORME ISO
INTERNATIONALE 4064-2
Deuxième édition
2001-06-01
Mesurage de débit d’eau dans les
conduites fermées — Compteurs d’eau
potable froide —
Partie 2:
Conditions d’installation et choix
Measurement of water flow in closed conduits — Meters for cold potable
water —
Part 2: Installation requirements and selection
Numéro de référence
ISO 4064-2:2001(F)
©
ISO 2001
---------------------- Page: 1 ----------------------
ISO 4064-2:2001(F)
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier peut
être imprimé ou visualisé, mais ne doit pas être modifiéà moins que l'ordinateur employéà cet effet ne bénéficie d'une licence autorisant
l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées acceptent de fait la
responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute responsabilité en la
matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la créationduprésent fichier PDF sont disponibles dans la rubrique General Info du
fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir l'exploitation de
ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation, veuillez en informer le
Secrétariat central à l'adresse donnée ci-dessous.
© ISO 2001
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous quelque
forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de l’ISO à
l’adresse ci-aprèsouducomité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 � CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax. + 41 22 749 09 47
E-mail copyright@iso.ch
Web www.iso.ch
Imprimé en Suisse
ii © ISO 2001 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO 4064-2:2001(F)
Sommaire Page
Avant-propos.iv
1 Domaine d'application.1
2Référence normative .1
3Termesetdéfinitions.2
4 Exemples d'utilisation de compteurs fonctionnant en parallèle et en groupe.2
5Critères pour le choix des compteurs d'eau.2
5.1 Considérations générales.2
5.2 Compteurs fonctionnant en parallèle et en groupe .2
6 Équipements d’installation du compteur d’eau.3
6.1 En amont.3
6.2 En aval .3
6.3 Compteurs fonctionnant en parallèle ou en groupe .3
7 Installation.4
7.1 Exigences générales .4
7.2 Règles d'installation .4
7.3 Compteurs fonctionnant en parallèle ou en groupe .5
8 Exigences particulières pour l'installation des compteurs Woltmann et des compteurs à jet
unique .5
8.1 Considérations générales.5
8.2 Types d’irrégularités .5
8.3 Méthodes permettant d’éliminer les irrégularités .5
9 Mise en service de compteurs neufs ou réparés .6
9.1 Considérations générales.6
9.2 Compteurs fonctionnant en parallèle ou en groupe .6
Bibliographie .7
© ISO 2001 – Tous droits réservés iii
---------------------- Page: 3 ----------------------
ISO 4064-2:2001(F)
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiéeaux
comités techniques de l'ISO. Chaque comité membre intéressé par une étude aledroit de fairepartie ducomité
technique créé à cet effet. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec la Commission
électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI, Partie 3.
Les projets de Normes internationales adoptés par les comités techniques sont soumis aux comités membres pour
vote. Leur publication comme Normes internationales requiert l'approbation de 75 % au moins des comités
membres votants.
L’attention est appelée sur le fait que certains des éléments delaprésente partie de l’ISO 4064 peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable de
ne pas avoir identifié de tels droits de propriété et averti de leur existence.
La Norme internationale ISO 4064-2 a étéélaboréepar le comité technique ISO/TC 30, Mesure de débit des
fluides dans les conduites fermées, sous-comité SC 7, Méthodes volumétriques, y compris les compteurs d'eau.
Cette deuxième édition annule et remplace la première édition (ISO 4064:1978), dont elle constitue une révision
technique.
L'ISO 4064 comprend les parties suivantes, présentées sous le titre général Mesurage de débit d'eau dans les
conduites fermées — Compteurs d'eau potable froide:
� Partie 1: Spécifications
� Partie 2: Conditions d'installation et choix
� Partie 3: Méthodes et matériels d’essai
iv © ISO 2001 – Tous droits réservés
---------------------- Page: 4 ----------------------
NORME INTERNATIONALE ISO 4064-2:2001(F)
Mesurage de débit d'eau dans les conduites fermées —
Compteurs d'eau potable froide —
Partie 2:
Conditions d'installation et choix
1 Domaine d'application
La présente partie de l’ISO 4064 définit les critères pour le choix des compteurs d'eau, les équipements
d'installation, l'installation, les exigences particulières pour certains compteurs et la mise en service des compteurs
neufs ou réparés afin de garantir l'exactitude du mesurage, la constance de mesure et la lecture sûre de l'indication
du compteur.
La présente partie de l’ISO 4064 est applicable uniquement aux installations comprenant un seul compteur d'eau;
elle est également applicable aux compteurs d'eau simples montés en parallèle ou groupés ensemble au même
emplacement. Elle n'est pas applicable aux compteurs «combinés» dont les spécifications figurent dans
l'ISO 7858-1.
Lorsque des réglementations nationales existent, elles doivent toujours prendre le pas sur les spécifications de la
présente partie de l’ISO 4064.
L’ISO 4064-1 traite de terminologie, de caractéristiques techniques et dimensionnelles, de caractéristiques
métrologiques et de perte de pression.
L’ISO 4064-3 traite de méthodes et matériels d’essai.
2Référence normative
Le document normatif suivant contient des dispositions qui, par suite de la référence qui y est faite, constituent des
dispositions valables pour la présente partie de l'ISO 4064. Pour les références datées, les amendements
ultérieurs ou les révisions de ces publications ne s’appliquent pas. Toutefois, les parties prenantes aux accords
fondés sur la présente partie de l'ISO 4064 sont invitées à rechercher la possibilité d'appliquer l’édition la plus
récente du document normatif indiqué ci-après. Pour les références non datées, la dernière édition du document
normatif en référence s’applique. Les membres de l'ISO et de la CEI possèdent le registre des Normes
internationales en vigueur.
ISO 4064-1:1993, Mesurage de débit d'eau dans les conduites fermées — Compteurs d'eau potable froide —
Partie 1: Spécifications.
© ISO 2001 – Tous droits réservés 1
---------------------- Page: 5 ----------------------
ISO 4064-2:2001(F)
3 Termes et définitions
Pour les besoins de la présente partie de l'ISO 4064, les termes et définitions suivants s’appliquent.
3.1
fonctionnement en parallèle
fonctionnement de deux ou plusieurs compteurs groupés ensemble, et raccordés à une alimentation commune et à
un circuit d'utilisation commun
3.2
fonctionnement en groupe
fonctionnement de plusieurs compteurs lorsque leurs entrées sont raccordées à une alimentation commune ou
lorsque leurs sorties sont raccordées à un circuit d'utilisation commun, mais pas les deux à la fois en même temps
4 Exemples d'utilisation de compteurs fonctionnant en parallèle et en groupe
Des compteurs d'eau peuvent être montés en parallèle quand l'installation d'un gros compteur unique ne permet
pas de satisfaire à la demande d'eau maximale ni de couvrir toute la gamme de débits exigée.
Des compteurs d'eau peuvent être montés en parallèle lorsque des compteurs «en réserve» sont nécessaires pour
assurer la continuité de la distribution et la mesure du débit, en cas de colmatage du filtre ou de détérioration du
compteur d'eau.
Des compteurs fonctionnent en groupe, ce qui facilite leur accessibilité, leur entretien et leur relevé, lorsqu'il est
nécessaire de répartir une fourniture d'eau en un certain nombre de dérivations, comme par exemple dans un
immeuble d’appartements, ou lorsqu'il est nécessaire de réunir dans une conduite principale commune plusieurs
alimentations faisant chacune l’objet d'un comptage, comme dans un complexe de traitement des eaux.
5Critères pour le choix des compteurs d'eau
5.1 Considérations générales
Le type, la classe métrologique et la taille du compteur d'eau sont déterminés d'après les caractéristiques
d’utilisation et celles du réseau, notamment:
� la pression d'alimentation disponible;
� les caractéristiques physico-chimiques de l'eau;
� la perte de pression admissible dans le compteur;
� les débits attendus: les débits q , q et q du compteur (tels que définis dans l'ISO 4064-1:1993, article 3)
min p s
doivent être compatibles avec les conditions de débits attendues des réseaux;
� l’adéquation du type de compteur aux conditions d’installation projetées.
5.2 Compteurs fonctionnant e
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.