Abstract

The object of this technical report is to give general information  about the systems of plugs and socket-outlets for household and     similar purposes which are used in the IEC countries. The report    only contains National Systems which are commonly used in homes and offices. It is therefore limited to systems for a.c. with a rated   voltage above 50 V but not exceeding 440 V, intended for household  and similar purposes, either indoors or outdoors. The report only   contains systems for which standard sheets have been published in a National Standard, which may be a National Standard of the country  itself or any other IEC member country                             [
]This English-language version is derived from the original bilingual publication by leaving out all French-language pages. Missing page   numbers correspond to the French-language pages.

Status
Published
Public Enquiry End Date
29-Sep-2009
Publication Date
15-Oct-2009
Technical Committee
EPR - Electrical accessories
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
13-Oct-2009
Due Date
18-Dec-2009
Completion Date
16-Oct-2009

Buy Documents

Technical report

SIST-TP IEC/TR 60083:2009

English language (185 pages)
Preview
Preview
e-Library read for
×1 day

SIST-TP IEC/TR 60083:2009 is the Slovenian publication of the IEC technical report IEC/TR 60083 from the International Electrotechnical Commission (IEC). It gives general information on the national systems of plugs and socket-outlets used in IEC member countries for household and similar general use, including alternating-current (a.c.) systems above 50 V and up to 440 V. The report is a reference document for engineers, quality managers, buyers, and standards staff who need to identify which national plug and socket-outlet system applies in a given market.

What does SIST-TP IEC/TR 60083:2009 specify?

SIST-TP IEC/TR 60083:2009 specifies a country-by-country overview of plug and socket-outlet systems used for household and similar purposes in IEC member countries. It is an information report, not a design standard for one universal system.

Clause 1 limits the report to systems commonly used in homes and offices, for a.c., with rated voltage above 50 V and not exceeding 440 V, indoors or outdoors. It also limits the content to systems for which standard sheets have been published in a national standard.

Clause 2 contains the list of national systems used in IEC member countries. Each country appears as one or more standard sheets with sketches, ratings, compatibility notes, and a reference to the relevant national standard or regulation.

Annex A is informative and gives instructions for additional contributions and revisions. It also shows the form layout, the country code format, the data fields to be filled in, and the ISO 3166-1 two-letter country codes.

What are the key requirements of SIST-TP IEC/TR 60083:2009?

The main role of SIST-TP IEC/TR 60083:2009 is to define the boundaries and presentation of the country sheets, and to show how national systems are reported. The practical value is that a reader can quickly see which plug and socket-outlet patterns are used, what they are rated for, and what national document defines them.

What systems are included?

Clause 1 says the report covers only systems used for household and similar purposes, including homes and offices. It is limited to a.c. systems with rated voltage above 50 V and not exceeding 440 V.

In practice, that means the report is aimed at everyday mains accessories rather than special-purpose industrial or low-voltage systems. If you are selecting accessories for domestic use, this tells you whether the system belongs in the scope of the report.

Clause 1 also limits the report to systems that already have standard sheets published in a national standard. In practice, the report is a register of established national systems, not a collection of experimental or informal variants.

What does each country sheet show?

Clause 2 presents each national system as a sheet with sketch designations, rated values, and references. Many sheets also note whether the system is fixed, portable, or both, and whether the plug and socket-outlet are compatible with other listed systems.

This matters because compatibility is often the deciding issue in procurement, design, and certification. The sheet tells you whether a plug can enter a socket-outlet, whether a socket-outlet accepts more than one plug type, and whether a system is limited to a special use such as IT equipment, shavers, or class-specific equipment.

How are safety-related conditions recorded?

The national sheets often carry practical restrictions such as shuttering, polarisation, earthing contact, sleeving of pins, or fused plugs. Some sheets also state special installation conditions, such as use only in certain locations, or use only in switched socket-outlets.

For the reader, this is the part to check when deciding whether a product is acceptable in that country. It shows not only the shape of the accessory, but also the safety and usability features that the national system expects.

How is the report kept current?

The foreword says the content is based on information supplied by the IEC National Committees, and those committees are responsible for the accuracy of the information they submit. The introduction says that amendments, additions, and other revisions should be notified to the IEC Central Office.

In practice, this means the national sheets should be treated as country-maintained information. If a national system changes, the update path is through the relevant committee and the IEC maintenance process, not through ad hoc local interpretation.

What guidance is given for future systems?

The introduction says the report shows the diversity of systems in use and advises countries that need a new or replacement system to follow IEC 60906-1 and IEC 60906-2. It frames those publications as the recommended basis for future National Standards.

That matters to policy makers and standards bodies because the report is not only a catalogue of existing systems. It also points toward a more uniform future approach when a country is introducing or replacing a system.

How are revisions and contributions prepared?

Annex A gives the submission instructions for new or revised material. It specifies the page format, country code use, date format, pole notation, voltage and current entries, sketch presentation, and the reference fields to be completed.

For contributors, this is the working template for adding or updating a national system. For readers, it explains why the country sheets have a consistent layout and how to interpret the data fields.

What terms does SIST-TP IEC/TR 60083:2009 define?

  • a.c. - Alternating current; the report applies only to systems used on a.c. supplies.
  • National Committee - The IEC national body that submits, revises, and is responsible for the information on its country sheets.
  • standard sheet - The page format used for one national plug or socket-outlet system, showing sketches, ratings, and references.
  • fixed and portable - A description used on the sheets to show whether the accessory is intended for fixed installation, portable use, or both.
  • Class I equipment - Equipment intended to use protective earthing, as reflected in the notes on several national sheets.
  • Class II equipment - Equipment intended for use without protective earthing, also identified in some country notes.
  • IPX0 - A protection level mentioned in the country sheets, indicating no special protection against water ingress.

Who uses SIST-TP IEC/TR 60083:2009?

IEC National Committees use SIST-TP IEC/TR 60083:2009 to maintain their country sheets and submit revisions in a common format. National standards bodies use it as a reference when describing the national plug and socket-outlet system in force in their country.

Manufacturers of plugs, socket-outlets, adaptors, and appliances use it to identify the national system they have to match. That helps them choose the correct geometry, rating, and compatibility conditions for a target market.

Quality managers, buyers, compliance teams, and certification bodies use it to check whether a product is intended for the right national system and whether it carries the right reference to the relevant national standard or regulation. Installers and specifiers use it when selecting accessories for domestic, office, portable, or special-use applications.

What changed in SIST-TP IEC/TR 60083:2009 from the previous edition?

SIST-TP IEC/TR 60083:2009 is the fifth edition and it cancels and replaces the fourth edition published in 2004. The foreword describes it as a technical revision.

The changes stated in the document are:

  • Replacement of all sheets for Denmark, France, Japan, Norway, and Spain
  • Replacement of sheet No. 4 for Finland
  • Replacement of sheet No. 7 for Italy
  • Addition of a new sheet No. 3 for Germany
  • Addition of new sheets for Mexico
  • Addition of new sheets for Serbia and Montenegro
  • Replacement of sheet No. 3 for Slovakia
  • Replacement of sheet No. 4 and sheet No. 5 by a new sheet No. 4 for Sweden

Which standards are used with SIST-TP IEC/TR 60083:2009?

SIST-TP IEC/TR 60083:2009 is supported by several standards named in the document, each serving a different role.

  • IEC 60884-1 - Annex A uses it for the pole notation and table reference used in the submission format, and some national sheets refer to it for safety-related conformity.
  • IEC 60906-1 - The introduction recommends this standard for any country needing a new or replacement system.
  • IEC 60906-2 - The introduction gives the same recommendation for replacement or new national systems.
  • EN 50075 - Many country sheets cite it for compatibility with small two-pole plug systems.
  • National standards and regulations - Each country sheet names the national document that defines the listed system, such as AS/NZS 3112, NBR 14136, BS 1363, BS 546, NEMA WD6, NEN 1020, NEK 502, SS 145, and others.

What does the SIST-TP IEC/TR 60083:2009 document contain?

The document contains a foreword, an introduction, Clause 1 on scope and object, Clause 2 with the country-by-country list of systems, and Annex A with submission instructions. The body of the report is made up of national sheets that show sketch designations, rated values, and compatibility notes.

The country sheets also name the relevant national standard or regulation and often add practical notes such as shuttering, polarity, earthing, sleeving, fused plugs, or special-use limitations. Several sheets include contact details for the national standards body or other source of further information.

Annex A contains instructions for preparing additional contributions and revisions, example forms, blank forms, and a two-letter country code list according to ISO 3166-1. It shows how the report keeps a uniform layout across countries and across revisions.

Relations

Effective Date
01-Dec-2009

Buy Documents

Technical report

SIST-TP IEC/TR 60083:2009

English language (185 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

SIST-TP IEC/TR 60083:2009 is a technical report published by the Slovenian Institute for Standardization (SIST). Its full title is "Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC". This standard covers: The object of this technical report is to give general information about the systems of plugs and socket-outlets for household and similar purposes which are used in the IEC countries. The report only contains National Systems which are commonly used in homes and offices. It is therefore limited to systems for a.c. with a rated voltage above 50 V but not exceeding 440 V, intended for household and similar purposes, either indoors or outdoors. The report only contains systems for which standard sheets have been published in a National Standard, which may be a National Standard of the country itself or any other IEC member country [<BR>]This English-language version is derived from the original bilingual publication by leaving out all French-language pages. Missing page numbers correspond to the French-language pages.

The object of this technical report is to give general information about the systems of plugs and socket-outlets for household and similar purposes which are used in the IEC countries. The report only contains National Systems which are commonly used in homes and offices. It is therefore limited to systems for a.c. with a rated voltage above 50 V but not exceeding 440 V, intended for household and similar purposes, either indoors or outdoors. The report only contains systems for which standard sheets have been published in a National Standard, which may be a National Standard of the country itself or any other IEC member country [<BR>]This English-language version is derived from the original bilingual publication by leaving out all French-language pages. Missing page numbers correspond to the French-language pages.

SIST-TP IEC/TR 60083:2009 is classified under the following ICS (International Classification for Standards) categories: 29.120.30 - Plugs, socket-outlets, couplers. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST-TP IEC/TR 60083:2009 has the following relationships with other standards: It is inter standard links to SIST IEC/TR 60083:1999. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST-TP IEC/TR 60083:2009 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2009
1DGRPHãþD
SIST IEC/TR 60083:1999
9WLþLLQYWLþQLFH]DGRPDþRLQSRGREQRVSORãQRXSRUDERVWDQGDUGL]LUDQLYGUåDYDK
þODQLFDK,(&
Plugs and socket-outlets for domestic and similar general use standardized in member
countries of IEC
Ta slovenski standard je istoveten z: IEC/TR 60083
ICS:
29.120.30 9WLþLYWLþQLFHVSRMNH Plugs, socket-outlets,
couplers
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

TECHNICAL
IEC
REPORT
TR 60083
Fifth edition
2006-04
Plugs and socket-outlets for domestic
and similar general use standardized
in member countries of IEC
© IEC 2006 Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical,
including photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
XJ
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue

TR 60083 Ó IEC:2006 – 3 –
CONTENTS
Foreword…………………………………………………………………………………………….7
Introduction………………………………………………………………………………………….9
National systems used in    section
Argentina (information not available)
Australia…………………………………………………………………………………………….AU
Austria……………………………………………………………………………………………….AT
Belarus (information not available)
Belgium…………………………………………………………………………………………….BE
Bulgaria (information not available)
Brazil ……………………………………………………………………………………………….BR
Canada…………………………………………………………………………………………….CA
China……………………………………………………………………………………………….CN
Croatia (information not available)
Czech Republic…………………………………………………………………………………….CZ
Denmark…………………………………………………………………………………………….DK
Egypt (information not available)
Finland……………………………………………………………………………………………… FI
France……………………………………………………………………………………………….FR
Germany…………………………………………………………………………………………….DE
Greece (information not available)
Hungary (information not available)
India (information not available)
Indonesia (information not available)
Iran (information not available)
Ireland (information not available)
Israel (information not available)
Italy…………………………………………………………………………………………….….…IT
Japan…………………………………………………………………………………………………JP
Korea (Republic of) ……………………………………………………………………………….KR
Luxembourg (information not available)
Malaysia…………………………………………………………………………………………….MY
Mexico……………………………………………………………………………………………… MX
Netherlands…………………………………………………………………………………………NL
New Zealand……………………………………………………………………………………….NZ
Norway………………………………………………………………………………………………NO
Pakistan (information not available)
Poland……………………………………………………………………………………………….PO
Portugal…………………………………………………………………………………………….PT
Romania (information not available)
Russian Federation (information not available)
Saudi Arabia ………………………………………………………………………………….….SA
Serbia and Montenegro …………………………………………………………………….……CS
Singapore………………………………………………………………………………………….SG
Slovakia…………………………………………………………………………………………….SK
Slovenia (information not available)
South Africa (information not available)

TR 60083 Ó IEC:2006 – 5 –
Spain…………………………………………………………………………………………………ES
Sweden…………………………………………………………………………………………….SE
Switzerland…………………………………………………………………………………….….CH
Thailand (information not available)
Turkey (information not available)
Ukraine (information not available)
United Kingdom…………………………………………………………………………………….GB
United States of America…………………………………………………………………………US

TR 60083  IEC:2006 – 7 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
PLUGS AND SOCKET-OUTLETS FOR DOMESTIC AND SIMILAR GENERAL
USE STANDARDIZED IN MEMBER COUNTRIES OF IEC

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
The main task of IEC technical committees is to prepare International Standards. However, a
technical committee may propose the publication of a technical report when it has collected
data of a different kind from that which is normally published as an International Standard, for
example "state of the art".
IEC 60083, which is a technical report, has been prepared by subcommittee 23B: Plugs,
socket -outlets and switches, of IEC technical committee 23: Electrical accessories.
The fifth edition cancels and replaces the fourth edition published in 2004 and constitutes a
technical revision. It includes some replacements of the sheets concerning the following
countries: DK, FI, FR, DE, IT, JP, NO, SK, ES and SE. New sheets for MX and CS have been
added to those of the previous edition.

TR 60083  IEC:2006 – 9 –
The text of this technical report is based on the following documents:
Enquiry draft Report on voting
23B/807/DTR 23B/817/RVC
Full information on the voting for the approval of this technical report can be found in the
report on voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
TR 60083 © IEC:2006 – 11 –
INTRODUCTION
This technical report shows the great variety of systems in use today. In order to reduce this
variety in future, even though such a change may take many years, it is advised that the
recommendations in IEC 60906-1 and IEC 60906-2 be followed:
"that any country in need of a new or a replacement system adopt this standard as its future
National Standard".
The content of this report is based on the information submitted by the National Committees
of IEC which are responsible for the accuracy of the information given. Any revision caused
by amendments and additions as a consequence of further development of their National
System(s) or introduction of a different system should be notified to the IEC Central Office.
For additional contributions or revisions of already submitted information, reference is made
to Annex A which contains the instructions for submitting material to this technical report.
National Committees are asked to follow the instructions precisely in order to obtain a uniform
presentation in this report.
The IEC Central Office will maintain a register of the revised information received from
National Committees.
This fifth edition includes the following modifications to the previous edition:
Denmark replacement of all sheets
Finland replacement of sheet No. 4
France replacement of all sheets
Germany addition of new sheet No. 3
Italy replacement of sheet No. 7
Japan replacement of all sheets
Mexico new sheets (1 to 11)
Norway replacement of all sheets
Serbia and Montenegro new sheets (1 to 3)
Slovakia replacement of sheet No. 3
Spain replacement of all sheets
Sweden replacement of sheet No. 4 and 5 by a new sheet No. 4

TR 60083 © IEC:2006 – 13 –
PLUGS AND SOCKET-OUTLETS FOR DOMESTIC AND SIMILAR GENERAL
USE STANDARDIZED IN MEMBER COUNTRIES OF IEC

1 Scope and object
The object of this technical report is to give general information about the systems of plugs
and socket -outlets for household and similar purposes which are used in the IEC countries.
The report only contains National Systems which are commonly used in homes and offices. It
is therefore limited to systems for a.c. with a rated voltage above 50 V but not exceeding
440 V, intended for household and similar purposes, either indoors or outdoors.
The report only contains systems for which standard sheets have been published in a
National Standard, which may be a National Standard of the country itself or any other IEC
member country.
2 List of plugs and socket-outlets which are used in IEC member countries
The following sheets give the national systems used in IEC member countries.

TR 60083 © IEC:2006 – 15 –
AU 1 of AU 2
IEC National system used in
60083 AUSTRALIA
Date: 2006-01-25
Rated values of
Sketch designations
accessories
Number of
poles
Voltage Current
Socket-outlets Plugs
V A
2P+
250 10
2P+
250 10
Portable socket-outlets for cords are specified in AS/NZS 3120. AS/NZS 3112 provides for a two pin
10A plug which has the same shape as the three pin 10A plug but no earth pin. A 10A plug is
compatible with a 15A socket-outlet. A 15A plug is prevented from entering a 10A socket-outlet by the
size of the earth pin.
For reference and further information, see AU2

TR 60083 © IEC:2006 – 17 –
AU 2 of AU 2
IEC National system used in
60083 AUSTRALIA
Date: 2006-01-25
Rated values of
Sketch designations
accessories
Number of
poles
Voltage Current
Socket-outlets Plugs
V A
2P+
250 15
Reference of National Standard or Regulation: AS/NZS 3112

Further information obtainable Standards Australia Limited Telephone: +61 2 8206 6000
from: GPO Box 476 Fax: +61 2 8206 6001
Sydney NSW 2001 E-mail:    mail@standards.org.au
Australia Website:   www.standards.org.au

Distribution and subscription SAI Global Limited Telephone: +61 2 8206 6010
from: GPO Box 5420 Fax: +61 2 8206 6020
Sydney NSW 2001 E-mail:    sales@sai-global.com
Australia Website:   www.sai-global.com

TR 60083 © IEC:2006 – 19 –
IEC       National system used in                       AT1 of AT 5
60083 AUSTRIA                     Date: 2005-12-13
Rated values of
Sketch designation
accessories
Number of
poles
Voltage         Current
Socket-outlets
Plugs
V A
2P + T 250 10/16
or 16 ~
ÖNORM E 6622 part 1
Type A
ÖNORM E 6624
ÖNORM E 6622 part 2
Type B
ÖNORM E 6622 part 4
ÖNORM E 6622 part 9
(shutter)
ÖNORM E 6623
ÖNORM E 6622 part 10
(for incorporating)
ÖNORM E 6622 part 8
ÖNORM E 6622 part 7
2P + T 250 10/16
Splashproof
(splashproof, portable)
portable
or 16 ~
For reference and further information, see AT 5.

TR 60083 © IEC:2006 – 21 –
IEC       National system used in                       AT2 of AT 5
60083 AUSTRIA                     Date: 2005-12-13
Rated values of
Sketch designation
accessories
Number of
poles
Voltage         Current
Socket-outlets
Plugs
V A
2,5 + 10/16
or 16 ~
ÖNORM E 6623 part 3
2P + T
2,5 + 10/16
or 16 ~
ÖNORM E 6623 part 3
250 10/16
or 16 ~
ÖNORM E 6623 part 3
Portable socket-outlet
For reference and further information, see AT 5.

TR 60083 Ó IEC:2006 – 23 –
National system used in
IEC       AT3 of AT 5
60083 Date: 2005-12-13
AUSTRIA
Rated values of
Sketch designation
accessories
Number
of poles Voltage
Current
Plugs
Socket-outlets
Fich
V A
10/16
2P
or 16 ~
ÖNORM E 6624
2P
10/16
ÖNORM E 6622 part 6
or 16 ~
(splashproof, portable)
2P 250 2,5
ÖNORM E 6622-11
(portable)
ÖNORM E 6622-5
(adaptor)
For reference and further information, see AT 5.

TR 60083 Ó IEC:2006 – 25 –
IEC       National system used in                      AT4 of AT 5
60083 Date: 2005-12-13
AUSTRIA
Rated values of
Sketch designation
accessories
Number
of poles Voltage
Current
Plugs
Socket-outlets
Fich
V A
2P 250
2,5
EN 50075
ÖNORM E 6620
Plug of page 4 is compatible with socket-outlet of page 1
For reference and further information, see AT 5.

TR 60083 Ó IEC:2006 – 27 –
IEC       National system used in                       AT 5 of AT 5
60083 AUSTRIA                     Date: 2005 - 12 - 13
Rated values of
Sketch designation
accessories
Number of
poles Voltage         Current
Socket-outlets Plugs
V A
3P+N+T 230/400
ÖNORM E 6611
ÖNORM E 6610
ÖNORM E 6612 ÖNORM E 6613
Reference of National standard or Regulation:
ÖVE-IG 31
ÖEK
Further information
Eschenbachgasse 9 Telephone: + 43 1 587 63 73
obtainable
A-1010 Wien Telefax: + 43 1 586 74 08
from:
ÖEK
Distribution and
Telephone: + 43 1 587 63 73
Eschenbachgasse 9
subscription
A-1010 Wien Telefax: + 43 1 586 74 08
from:
TR 60083 Ó IEC:2006 – 29 –
IEC       National system used in                       BE 1 of BE 5
60083 BELGIUM                       Date: 1994 - 03 - 09
Rated values of
Sketch designation
accessories
Number of
poles Voltage         Current
Socket-outlets Plugs
V A
2P + 250 16
NBN C 61-112-1
VI
BNB C 61-112-1
V
Fixed and portable
1)
2P + 250 16
NBN C 61-112-1
VII
1) The socket-outlets also accept plugs according to Standard Sheet VII, XVI and XVII of
NBN C 61-112-1
For reference and further information, see BE 5

TR 60083 Ó IEC:2006 – 31 –
IEC       National system used in                       BE 2 of BE 5
60083 BELGIUM                       Date: 1994 - 03 - 09
Rated values of
Sketch designation
accessories
Number of
poles Voltage         Current
Socket-outlets Plugs
V A
2P 250 16
NBN C 61-112-1
XVII
2P 250 2,5
NBN C 61-112-1
XVI
For reference and further information, see BE 5

TR 60083 Ó IEC:2006 – 33 –
IEC       National system used in                       BE 3 of BE 5
60083 BELGIUM                       Date: 1994 - 03 - 09
Rated values of
Sketch designation
accessories
Number of
poles Voltage         Current
Socket-outlets Plugs
V A
2P 250 2,5
NBN C 61-112-1
XXIII
NBN C 61-112-1
XVI
2P 250 16
NBN C 61-112-1
I
For reference and further information, see BE 5

TR 60083 Ó IEC:2006 – 35 –
IEC       National system used in                       BE 4 of BE 5
60083 BELGIUM                       Date: 1 994 - 03 - 09
Rated values of
Sketch designation
accessories
Number of
poles Voltage         Current
Socket-outlets Plugs
V A
2P + 415
NBN C 61-112-1
XXI
NBN C 61-112-1
XXII
3P + 415
NBN C 61-112-1 NBN C 61-112-1
XXII
XXI
For reference and further information, see BE 5

TR 60083 Ó IEC:2006 – 37 –
IEC National system used in BE 5 of BE 5
60083 Belgium Date: 1994-03-09
Rated values of
Sketch designation
accessories
Number of
poles Voltage Current
Socket-outlets Plugs
V A
3P + N + 415 16      32
NBN C 61 - 112 - 1 NBN C 51 - 112 - 1
XXI XXII
Reference of National Standard or Regulation:
NBN C 61 - 112 - 1
Plugs and socket-outlets for domestic and similar purposes.
Belgian Electrotechnical Committee
Telephone: +32 2 706 85 70
Further information
obtainable Bld. Auguste Reyerslaan, 80
Telefax : +32 2 706 85 80
from:
B - 1030 BRUXELLES / BRUSSEL Telex:
Institut Belge de Normalisation
Telephone: +32 2 738 01 11
Distribution and
subscription Avenue de la BRABANCONNE, 29 Telefax : +32 2 733 42 64
from:
B - 1000 BRUXELLES / BRUSSEL Telex:

TR 60083 Ó IEC:2006 – 39 –
IEC       National system used in                       BR 1 of BR 2
60083 BRAZIL                       Date: 2002 - 12 - 29
Rated values of
Sketch designation
accessories
Number of
poles
Voltage         Current
Socket-outlets Plugs
V A
2P + 250 10
NBR 14136
Figures 1, 3, 5         NBR 14136
Fixed and portable Figure 7
2P 250 10
NBR 14136
Figures 9, 11        NBR 14136
Portable Figure 13
A 10A socket-outlet shall not allow the insert of a 20A plug, and the socket-outlets with
earthing contact shall allow the insert of plugs with and without earthing pin. The dimension of
+0,2
the entry holes corresponding to pin diameter is: Ø 4,3    mm. Insulation sleeves on the pins
- 0
are optional.
The rated voltage 250V corresponding to the application from 100V up to 250V.
For reference and further information, see BR 2.

TR 60083 Ó IEC:2006 – 41 –
IEC       National system used in                       BR 2 of BR 2
60083 BRAZIL                       Date: 2002 - 12 - 29
Rated values of
Sketch designation
accessories
Number of
poles
Voltage         Current
Socket-outlets Plugs
V A
2P + 250 20
NBR 14136
NBR 14136
Figure 6
Figures 2, 4, 6
Fixed and portable
2P 250 20
NBR 14136
Figures 10, 12
NBR 14136
Portable
Figure 14
Reference of National Standard or Regulation: NBR 14136
A 20A socket-outlet shall not allow the insert of a 10A and 20A plug, and the socket-outlets
with earthing contact shall allow the insert of plugs with and without earthing pin. The
+0,2
dimension of the entry holes corresponding to pin diameter is: Ø 5,0    mm. Insulation
- 0
sleeves on the pins are optional.
The rated voltage 250V corresponds to the application from 100V up to 250V.
COBEI Telephone: +55 11 3289-1544/0882
Further information
Av. Paulista, 1439 - Cj. 114 11°
Fax:     +55 11 3289-2179
obtainable
11° andar - CEP 01311-200 e-mail    cobei@cobei.org.br
from:
São Paulo - BRAZIL
COBEI Telephone: +55 11 3289-1544/0882
Distribution and
Av. Paulista, 1439 - Cj. 114 Fax:     +55 11 3289-2179
subscription
11° andar - CEP 01311-200 e-mail    cobei@cobei.org.br
from:
São Paulo - BRAZIL
TR 60083  IEC:2006 – 43 –
IEC National system used in CA 1 of CA 11
60083 CANADA Date: 2002-05 07
Rated values of Sketch designation
accessories
Number of
poles
Voltage Current Socket-outlets Plugs
V A
1P + N 125 15
NEMA 1-15 R NEMA 1-15 P
Fixed and Portable
2 P 250 15
NEMA 2-15 P
No socket-outlet configuration
2 P 250 20
NEMA 2-20 R NEMA 2-20 P
Fixed and Portable
NOTES: 1) X, Y, Z = Poles; W = N (Neutral); G (or  ) = Earth
2) Plug NEMA 1-15 P can be polarized or non-polarized
3) Plug NEMA 1-15 P also mates with socket-outlet NEMA 5-15 R (on page 2)
4) Plug NEMA 2-15 P mates with socket-outlet NEMA 6-15 R (on page 3)
For reference and further information, see CA11

TR 60083 © IEC:2006 – 45 –
IEC National system used in CA 2 of CA 11
60083 CANADA Date: 2002-05 07
Rated values of Sketch designation
accessories
Number of
poles
Voltage Current Socket-outlets Plugs
V A
1P + N 125 30
NEMA 1-30 P
No socket-outlet configuration
2 P 250 30
NEMA 2-30 R NEMA 2-30 P
Fixed and Portable
1P + N + 125 15
NEMA 5-15 R NEMA 5-15 P
Fixed and Portable
NOTES: 1) X, Y, Z = Poles; W = N (Neutral); G (or  ) = Earth
2) Plug NEMA 1-30 P mates with socket-outlet NEMA 5-30 R (on page 5)
3) Socket-outlet NEMA 5-15 R also mates with plug NEMA 1-15 P (on page 1)
For reference and further information, see CA11

TR 60083  IEC:2006 – 47 –
IEC National system used in CA 3 of CA 11
60083 CANADA Date: 2002-05 07
Rated values of Sketch designation
accessories
Number of
poles
Voltage Current Socket-outlets Plugs
V A
2P + 250 15
NEMA 6-15 R NEMA 6-15 P
Fixed and Portable
1P + N + 277 AC 15
NEMA 7-15 R NEMA 7-15 P
Fixed and Portable
1P + N + 125 20
CSA 5-20 R NEMA 5-20 P
Fixed and Portable
1P + N + 125 20
CSA 5-20 RA
(Alternate)
Fixed and Portable
NOTES: 1) X, Y, Z = Poles; W = N (Neutral); G (or  ) = Earth
2) Socket-outlet NEMA 6-15 R also mates with plug NEMA 2-15 R (on page 1)
3) Plug NEMA 5-20 P also mates with socket-outlet CSA 5-20 RA
For reference and further information, see CA11

TR 60083  IEC:2006 – 49 –
IEC National system used in CA 4 of CA 11
60083 CANADA Date: 2002-05 07
Rated values of Sketch designation
accessories
Number of
poles
Voltage Current Socket-outlets Plugs
V A
2P + 250 20
CSA 6-20 R NEMA 6-20 P
Fixed and Portable
2P + 250 20
CSA 6-20 RA
(Alternate)
Fixed and Portable
1P + N + 277 AC 20
NEMA 7-20 R NEMA 7-20 P
Fixed and Portable
2P + N 125 / 250 20
NEMA 10-20 R NEMA 10-20 P
Fixed and Portable
NOTES: 1) X, Y, Z = Poles; W = N (Neutral); G (or  ) = Earth
2) Plug NEMA 6-20 P also mates with socket-outlet CSA 6-20 RA
For reference and further information, see CA11

TR 60083  IEC:2006 – 51 –
IEC National system used in CA 5 of CA 11
60083 CANADA Date: 2002-05 07
Rated values of Sketch designation
accessories
Number of
poles
Voltage Current Socket-outlets Plugs
V A
1P + N + 125 30
NEMA 5-30 R NEMA 5-30 P
Fixed and Portable
2P + 250 30
NEMA 6-30 R NEMA 6-30 P
Fixed and Portable
1P + N + 277 AC 30
NEMA 7-30 R NEMA 7-30 P
Fixed and Portable
2P + N 125 / 250 30
NEMA 10-30 R NEMA 10-30 P
Fixed and Portable
NOTES: 1) X, Y, Z = Poles; W = N (Neutral); G (or  ) = Earth
2) Socket-outlet NEMA 5-30 R also mates with plug NEMA 1-30 P (on page 2)
For reference and further information, see CA11

TR 60083 © IEC:2006   – 53 –
IEC National system used in CA 6 of CA 11
60083 CANADA Date: 2002-05 07
Rated values of Sketch designation
accessories
Number of
poles
Voltage Current Socket-outlets Plugs
V A
1P + N + 125 50
NEMA 5-50 R NEMA 5-50 P
Fixed and Portable
2P + 250 50
NEMA 6-50 R NEMA 6-50 P
Fixed and Portable
1P + N + 277 AC 50
NEMA 7-50 R NEMA 7-50 P
Fixed and Portable
2P + N 125 / 250 50
NEMA 10-50 R NEMA 10-50 P
Fixed and Portable
NOTES: 1) X, Y, Z = Poles; W = N (Neutral); G (or  ) = Earth
For reference and further information, see CA11

TR 60083 © IEC:2006   – 55 –
IEC National system used in CA 7 of CA 11
60083 CANADA Date: 2002-05 07
Rated values of Sketch designation
accessories
Number of
poles
Voltage Current Socket-outlets Plugs
V A
2P 250 15
3 Phase
NEMA 11-15 R NEMA 11-15 P
Fixed and Portable
2P + N + 125 / 250 15
NEMA 14-15 R NEMA 14-15 P
Fixed and Portable
3P + 250 15
3 Phase
NEMA 15-15 R NEMA 15-15 P
Fixed and Portable
3P + N 120 / 208 15
3 Phase Y
NEMA 18-15 R NEMA 18-15 P
Fixed and Portable
NOTES: 1) X, Y, Z = Poles; W = N (Neutral); G (or  ) = Earth
2) Plug NEMA 11-15 P also mates with socket-outlet NEMA 11-20 R (on page 8)
For reference and further information, see CA11

TR 60083 © IEC:2006   – 57 –
IEC National system used in CA 8 of CA 11
60083 CANADA Date: 2002-05 07
Rated values of Sketch designation
accessories
Number of
poles
Voltage Current Socket-outlets Plugs
V A
3P 250 20
3 Phase
NEMA 11-20 R NEMA 11-20 P
Fixed and Portable
2P + N + 125 / 250 20
NEMA 14-20 R NEMA 14-20 P
Fixed and Portable
3P + 250 20
3 Phase
NEMA 15-20 R NEMA 15-20 P
Fixed and Portable
3P + N 120 / 208 20
3 Phase Y
NEMA 18-20 R NEMA 18-20 P
Fixed and Portable
NOTES: 1) X, Y, Z = Poles; W = N (Neutral); G (or  ) = Earth
2) Socket-outlet NEMA 11-20 R also mates with plug NEMA 11-15 P (on page 7)
For reference and further information, see CA11

TR 60083  IEC:2006 – 59 –
IEC National system used in CA 9 of CA 11
60083 CANADA Date: 2002-05 07
Rated values of Sketch designation
accessories
Number of
poles
Voltage Current Socket-outlets Plugs
V A
3P 250 30
3 Phase
NEMA 11-30 R NEMA 11-30 P
Fixed and Portable
2P + N + 125 / 250 30
NEMA 14-30 R NEMA 14-30 P
Fixed and Portable
3P + 250 30
3 Phase
NEMA 15-30 R NEMA 15-30 P
Fixed and Portable
3P + N 120 / 208 30
3 Phase Y
NEMA 18-30 R NEMA 18-30 P
Fixed and Portable
NOTES: 1) X, Y, Z = Poles; W = N (Neutral); G (or  ) = Earth
For reference and further information, see CA11

TR 60083  IEC:2006 – 61 –
IEC National system used in CA 10 of CA 11
60083 CANADA Date: 2002-05 07
Rated values of Sketch designation
accessories
Number of
poles
Voltage Current Socket-outlets Plugs
V A
3P 250 50
3 Phase
NEMA 11-50 R NEMA 11-50 P
Fixed and Portable
2P + N + 125 / 250 50
NEMA 14-50 R NEMA 14-50 P
Fixed and Portable
3P + 250 50
3 Phase
NEMA 15-50 R NEMA 15-50 P
Fixed and Portable
3P + N 120 / 208 50
3 Phase Y
NEMA 18-50 R NEMA 18-50 P
Fixed and Portable
NOTES: 1) X, Y, Z = Poles; W = N (Neutral); G (or  ) = Earth
For reference and further information, see CA11

TR 60083  IEC:2006 – 63 –
IEC National system used in CA 11 of CA 11
60083 CANADA Date: 2002-05 07
Rated values of Sketch designation
accessories
Number of
poles
Voltage Current Socket-outlets Plugs
V A
2P + N + 125 / 250 60
NEMA 14-60 R NEMA 14-60 P
Fixed and Portable
3P + 250 60
3 Phase
NEMA 15-60 R NEMA 15-60 P
Fixed and Portable
3P + N 120 / 208 60
3 Phase Y
NEMA 18-60 R NEMA 18-60 P
Fixed and Portable
Reference of National standard or Regulation: CSA C22.2 No. 42
NOTES: 1) X, Y, Z = Poles; W = N (Neutral); G (or  ) = Earth
2) For dimensional requirements see standard publication NEMA WD6
Further information obtainable EEMAC Telephone: +905 602 8877
from: 5800 Explorer Drive, Suite 200 Fax: +905 602 5686
Mississauga, ON, Canada L4W 5K9 E-mail: info@electrofed.com
Distribution and subscription Telephone:
from: Fax:
E-mail:
TR 60083 Ó IEC:2006 – 65 –
IEC       National system used in                       CN 1 of CN 7
60083 CHINA                      Date: 1995  - 07 - 30
Rated values of
Sketch designation
accessories
Number of
poles
Voltage         Current
Socket-outlets
Plugs
V A
2P 250 6 1)
GB 1002 Fig. 1 2)
1) For non-rewirable plugs only.
2) This 6 A plug is compatible with the 10 A socket-outlet of Fig. 2
For reference and further information, see CN 7

TR 60083 Ó IEC:2006 – 67 –
IEC       National system used in                       CN 2 of CN 7
60083 CHINA                       Date: 1995 - 07 - 30
Rated values of
Sketch designation
accessories
Number of
poles
Voltage         Current
Socket-outlets
Plugs
V A
2P 250 10
GB 1002 Fig. 2
Fixed and portable
GB 1002 Fig. 1
For reference and further information, see CN 7

TR 60083 Ó IEC:2006 – 69 –
IEC       National system used in                       CN 3 of CN 7
60083 CHINA                       Date: 1995 - 07 - 30
Rated values of
Sketch designation
accessories
Number of
poles Voltage         Current
Socket-outlets Plugs
V A
2P + 250 6 1)
GB 1002 Fig. 3 2)
1) For non-rewirable plugs only.
2) This 6 A plug is compatible with the 10 A socket-outlet of Fig. 4
For reference and further information, see CN 7

TR 60083 Ó IEC:2006 – 71 –
IEC       National system used in                       CN 4 of CN 7
60083 CHINA                       Date: 1995 - 07 - 30
Rated values of
Sketch designation
accessories
Number of
poles Voltage         Current
Socket-outlets Plugs
V A
2P + 250 10
GB 1002 Fig. 4
Fixed and portable
GB 1002 Fig. 3
For reference and further information, see CN 7

TR 60083 Ó IEC:2006 – 73 –
IEC       National system used in                       CN 5 of CN 7
60083 CHINA                       Date: 1995 - 07 - 30
Rated values of
Sketch designation
accessories
Number of
poles Voltage         Current
Socket-outlets Plugs
V A
2P + 250 16
GB 1002 Fig. 6
Fixed and portable
GB 1002 Fig. 5
For reference and further information, see CN 7

TR 60083 Ó IEC:2006 – 75 –
IEC       National system used in                       CN 6 of CN 7
60083 CHINA                       Date: 1995 - 07 - 30
Rated values of
Sketch designation
accessories
Number of
poles
Voltage         Current
Socket-outlets
Plugs
V A
2P 250 10
GB 1002 Fig. 7
Fixed and portable
For reference and further information, see CN 7

TR 60083 Ó IEC:2006 – 77 –
IEC       National system used in                       CN 7 of CN 7

60083 CHINA                       Date: 1995 - 07 - 30

Rated values of
Sketch designation
accessories
Number of
poles
Voltage         Current
Socket-outlets Plugs
V A
3P + 440 16 / 25 / 32
GB 1003 Fig. 1
GB 1003 Fig. 2
Reference of National Standard or Regulation:
Telephone: +86-20-84451171
Further information GEARI
obtainable         204 Xingang West Road            Telefax : +86-20-84192478
from: Guangzhou, China
E-mail: cnapc@geari.com
Telephone: +86-10-82262628
Distribution and SAC
Telefax : +86-10-82260660
subscription         9 Madian East Road, Haidian District
E-mail:
from: Beijing, China
webmaster_sac@sac.gov.cn
TR 60083 Ó IEC:2006 – 79 –
National system used in
CZ 1 of CZ 3
IEC
60083 THE CZECH REPUBLIC
Date: 2002-06-06
Rated values of
Sketch designation
accessories
Number
of poles
Voltage Current
Socket-outlets Plugs
V A
ÈSN 35 4516
(CEE 7 Standard sheet
VI)
250 16
2P +
ÈSN 35 4516
(CEE 7 Standard sheet
V)
Fixed and portable
ÈSN 35 4516
(CEE 7 Standard sheet
VII)
The socket-outlet accepts both plugs of CZ 1.
For reference and further information, see CZ 3

TR 60083 Ó IEC:2006 – 81 –
National system used in
CZ 2 of CZ 3
IEC
60083 THE CZECH REPUBLIC
Date: 2002-06-06
Rated values of
Sketch designation
accessories
Number
of poles
Voltage Current
Socket-outlets Plugs
V A
2P 250 16
ÈSN 35 4516
(CEE 7 Standard sheet
XVII)
2P 250 2,5
ÈSN 35 4516
(CEE 7 Standard sheet
XVI)
The plugs of CZ 2 are compatible with socket-outlet of CZ 1.
For reference and further information, see CZ 3

TR 60083 Ó IEC:2006 – 83 –
National system used in
CZ 3 of CZ 3
IEC
60083 THE CZECH REPUBLIC
Date: 2002-06-06
Rated values of
Sketch designation
accessories
Number
of poles
Voltage Current
Socket-outlets Plugs
V A
2P 250 2,5
ÈSN 35 4516
ÈSN 35 4516
(CEE 7 Standard sheet
Portable
XVI)
Reference of National standard or Regulation: ÈSN 35 4516 (in conformity with safety
requirements of IEC 60884-1 – see ÈSN IEC 60884-1:2003).

CZECH STANDARDS INSTITUTE
Telephone: + 42-2-21802111
Information division
Further information Fax :    + 42-2- 22328433
Biskupský dvur 5
obtainable from: E-mail:
110 02 Praha 1
ivana.novakova@csni.cz
Czech Republic
CZECH STANDARDS INSTITUTE
Telephone:+42-2-71961770
Distribution and
Hornomecholupská 40
Fax :    + 42-2-74866951
subscription from: 102 04 Praha 10
E-mail : odbyt@csni.cz
Czech Republic
TR 60083 Ó IEC:2006 – 85–
IEC       National system used in                       DK 1 of DK 9
60083 Denmark                      Date: 2005-07-07
Rated values of
Sketch designation
accessories
Number of
poles
Voltage         Current
Socket-outlets
Plugs
V A
2P + E  250 10 or 13
SB 107-2-D1
DK 1-1a
Fixed only
1)  2) 3)
SB 107-2-D1
DK 2-1a
2P+ E 250 13
SB 107-2-D1
DK 1-1b
Fixed only
2) 3)
1) The socket-outlets are only intended as part of switched socket-outlets or in double socket-outlets with the
outlets individually switched.
2) Shutters are mandatory for socket-outlets with IPX0 protection.
3) The socket-outlets also accept plugs according to Standard Sheets DK 2-5a, DKA 2-1a, DKA 2-1b,
EN 50075 and CEE7 Standard Sheets II, IV, VI, VII, XVI and XVII. The underlined types are for limited use only.
as they do not establish earth continuity.
For reference and further information, see DK 9.

TR 60083 Ó IEC:2006 – 87 –
IEC       National system used in                       DK 2 of DK 9
60083 Denmark                       Date: 2005-07-07
Rated values of
Sketch designation
accessories
Number of
poles
Voltage         Current
Socket-outlets
Plugs
V A
2P + E 250 10 or 13
SB 107-2-D1
SB 107-2-D1
DK 2-1a
DK 1-3a
Portable
1)  2) 3)
2P + E 250 10 or 13
SB 107-2-D1
SB 107-2-D1
DK 1-5a
DK 2-5a
Fixed and portable
4)
1) The socket-outlets are also used for integration in adaptors and equipment.
2) Note 2 and 3 on page 1 applies.
3) The marking with N is optional
4) For Information Technology. Only plugs according to Standard Sheet DK 2-5a can enter.
For reference and further information, see DK 9.

TR 60083 Ó IEC:2006 – 89 –
IEC       National system used in                       DK 3 of DK 9
60083 Denmark                     Date: 2005-07-07
Rated values of
Sketch designation
accessories
Number of
poles
Voltage         Current
Socket-outlets
Plugs
V A
2P + E 250 10 or 13
SB 107-2-D1
SB 107-2-D1
DK 1-7a
DK 2-5a
Portable only
1)
3P+N+E 250/440 16
N L L L
SB107-2-D1
SB107-2-D1
DK 5-1a
DK 6-1a
1) For Information Technology. Only plugs according to Standard Sheet DK 2-5a can enter.
For reference and further information, see DK 9.

TR 60083 Ó IEC:2006 – 91 –
IEC       National system used in                       DK 4 of DK 9
60083 Denmark                       Date: 2005-07-07
Rated values of
Sketch designation
accessories
Number of
poles
Voltage         Current
Socket-outlets
Plugs
V A
2P +E 250 10 or 13
SB 107-2-D1
DK 1-8a
Fixed only
1)  2) 3)
SB 107-2-D1
DK 2-8a
2P 250 13
SB 107-2-D1
DK 1-8b
Fixed only
1)  3)
1) For hospital use. Only plugs according to Standard Sheet DK 2-8a can enter
2) The socket -outlets are only intended to be used as part of switched socket-outlets or in double socket-
outlets with the outlets individually switched
3) Shutters are mandatory for socket-outlets with IPX0 protection.
For reference and further information, see DK 9.

TR 60083 Ó IEC:2006 – 93 –
IEC       National system used in                       DK 5 of DK 9
60083 Denmark                       Date: 2005-07-07
Rated values of
Sketch designation
accessories
Number of
poles Voltage         Current
Socket-outlets
Plugs
V A
2P +E 250 10 or 13
SB 107-2-D1              SB 107-2-D1
DK 1-8c DK 2-8a
Portable only
1)
2P 250 10 or 13
SB 107-2-D1
SB 107-2-D1
DKA 1-1c
DKA 2-1b
Fixed only
2)  3) 4)
1) Note 1 and 3 on pages 4 applies
...