SIST EN 50264-2-1:2008
Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
EN 50264-2-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: 0,6/1 kV unscreened, unsheathed (1 mm² to 400 mm²); 1,8/3 kV unscreened, unsheathed (1,5 mm² to 400 mm²); 1,8/3 kV unscreened, sheathed (1,5 mm² to 400 mm²); 3,6/6 kV unscreened, sheathed (2,5 mm² to 400 mm²). All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-2-1 should be read in conjunction with Part 1 "General requirements".
Bahnanwendungen - Starkstrom- und Steuerleitungen für Schienenfahrzeuge mit verbessertem Verhalten im Brandfall -- Teil 2-1: Leitungen mit vernetzter elastomerer Isolierung - Einadrige Leitungen
EN 50264-2-1 legt Anforderungen an und Aufbauten und Abmessungen von einadrigen Leitungen für folgende Bauarten und Nennspannungen fest: • 0,6/1 kV ohne Schirm, ohne Mantel (1 mm² bis 400 mm²); • 1,8/3 kV ohne Schirm, ohne Mantel (1,5 mm² bis 400 mm²); • 1,8/3 kV ohne Schirm, mit Mantel (1,5 mm² bis 400 mm²); • 3,6/6 kV ohne Schirm, mit Mantel (2,5 mm² bis 400 mm²). Alle Leitungen haben einen verzinnten Kupferleiter Klasse 5 nach EN 60228, eine halogenfreie Isolierung und gegebenenfalls einen halogenfreien Mantel. Sie sind für feste Verlegung im Schienenfahrzeug bestimmt oder für Verdrahtungen, bei denen im Betrieb begrenzt mit Bewegungen gerechnet werden muss. Die Anforderungen berücksichtigen eine dauernde Leitertemperatur von nicht mehr als 90 °C und eine maximale Kurzschlusstemperatur von 200 °C bei einer Dauer von 5 s. Unter Brandbedingungen zeigen die Leitungen besondere Leistungsmerkmale hinsichtlich der maximal zulässigen Weiterleitung der Flammen (Ausbreitung der Flammen) und der höchsten zulässigen Emission von Rauch und giftigen Gasen. EN 50264-2-1 sollte in Verbindung mit Teil 1 „Allgemeine Anforderungen“ gelesen werden.
Applications ferroviaires - Câbles de puissance et de contrôle à comportement au feu spécifié pour matériel roulant ferroviaire -- Partie 2-1: Câbles à enveloppe isolante réticulée - Câbles monoconducteurs
La EN 50264-2-1 spécifie les prescriptions, les constructions et les dimensions des câbles monoconducteurs des types et tensions assignées suivants: • 0,6/1 kV sans blindage ni gaine (de 1 mm² à 400 mm²); • 1,8/3 kV sans blindage ni gaine (de 1,5 mm² à 400 mm²); • 1,8/3 kV gainé sans blindage (de 1,5 mm² à 400 mm²); • 3,6/6 kV gainé sans blindage (de 2,5 mm² à 400 mm²). Tous les câbles monoconducteurs possèdent une âme en cuivre étamé de classe 5 selon la EN 60228, une isolation et une gaine sans halogènes. Ils sont destinés aux installations fixes ou soumis à de faibles flexions en service des matériels roulants ferroviaires. Les prescriptions sont basées pour une température permanente à l’âme ne dépassant pas 90 °C et à une température maximale de 200 °C pour une durée de 5 s en cas de court-circuit. Les câbles monoconducteurs présentent, en cas d’incendie, des performances particulières de propagation maximale admissible de la flamme (longueur brûlée) et d’émission de fumées et de gaz toxiques. Il est recommandé de lire la EN 50264-2-1 conjointement avec la Partie 1 “Prescriptions générales”.
Železniške naprave - Energetski in krmilni kabli za železniška vozna sredstva, ki imajo posebne ognjevarne lastnosti - 2-1. del: Kabli z zamreženo elastomerno izolacijo - Enožilni kabli
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 50264-2-1:2008
01-september-2008
1DGRPHãþD
SIST EN 50264-2:2003
Železniške naprave - Energetski in krmilni kabli za železniška vozna sredstva, ki
imajo posebne ognjevarne lastnosti - 2-1. del: Kabli z zamreženo elastomerno
izolacijo - Enožilni kabli
Railway applications - Railway rolling stock power and control cables having special fire
performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core
cables
Bahnanwendungen - Starkstrom- und Steuerleitungen für Schienenfahrzeuge mit
verbessertem Verhalten im Brandfall -- Teil 2-1: Leitungen mit vernetzter elastomerer
Isolierung - Einadrige Leitungen
Applications ferroviaires - Câbles de puissance et de contrôle à comportement au feu
spécifié pour matériel roulant ferroviaire -- Partie 2-1: Câbles à enveloppe isolante
réticulée - Câbles monoconducteurs
Ta slovenski standard je istoveten z: EN 50264-2-1:2008
ICS:
13.220.20 3RåDUQD]DãþLWD Fire protection
29.060.20 Kabli Cables
45.060.01 Železniška vozila na splošno Railway rolling stock in
general
SIST EN 50264-2-1:2008 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 50264-2-1:2008
---------------------- Page: 2 ----------------------
SIST EN 50264-2-1:2008
EUROPEAN STANDARD
EN 50264-2-1
NORME EUROPÉENNE
June 2008
EUROPÄISCHE NORM
ICS 13.220.20; 29.060.20; 45.060.01 Supersedes EN 50264-2:2002
English version
Railway applications -
Railway rolling stock power and control cables
having special fire performance -
Part 2-1: Cables with crosslinked elastomeric insulation -
Single core cables
Applications ferroviaires - Bahnanwendungen -
Câbles de puissance et de contrôle Starkstrom- und Steuerleitungen
à comportement au feu spécifié für Schienenfahrzeuge
pour matériel roulant ferroviaire - mit verbessertem Verhalten im Brandfall -
Partie 2-1: Câbles à enveloppe Teil 2-1: Leitungen mit vernetzter
isolante réticulée - elastomerer Isolierung -
Câbles monoconducteurs Einadrige Leitungen
This European Standard was approved by CENELEC on 2008-03-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50264-2-1:2008 E
---------------------- Page: 3 ----------------------
SIST EN 50264-2-1:2008
EN 50264-2-1:2008 – 2 –
Foreword
This European Standard was prepared by Working Group 12, Railway cables, of the Technical Committee
CENELEC TC 20, Electric cables, as part of the overall programme of work in the Technical Committee
CENELEC TC 9X, Electrical and electronic applications for railways.
The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50264-2-1 on
2008-03-01.
This European Standard supersedes EN 50264-2:2002.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
(dop) 2009-03-01
national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2011-03-01
with the EN have to be withdrawn
__________
---------------------- Page: 4 ----------------------
SIST EN 50264-2-1:2008
– 3 – EN 50264-2-1:2008
Contents
Page
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Definitions . 7
4 Rated voltage . 7
5 Marking and identification . 7
5.1 Marking of cable . 7
5.2 Core identification. 8
5.3 Sheath . 8
6 Construction of cables . 8
6.1 General . 8
6.2 Conductor . 8
6.3 Conductor screening . 8
6.4 Separator . 8
6.5 Insulation system. 8
6.6 Sheath . 9
6.7 Constructional components . 9
7 Tests . 15
7.1 Definitions relating to tests . 15
7.2 Conductor resistance . 15
7.3 Voltage test . 15
7.4 Insulation resistance . 15
7.5 Dielectric strength. 15
7.6 Spark test . 16
7.7 DC stability . 16
7.8 Surface resistance. 16
7.9 Ageing test . 16
7.10 Hot set test . 17
7.11 Compatibility . 17
7.12 Water absorption on sheath . 17
7.13 Ozone resistance . 17
7.14 Mineral oil resistance . 18
7.15 Fuel resistance . 18
7.16 Acid and alkali resistance . 19
7.17 Bending test at low temperature (cables with OD ≤ 12,5 mm) . 19
7.18 Cold elongation test (cables with OD > 12,5 mm) . 19
7.19 Impact test at low temperature . 20
7.20 Reaction to fire – Cable . 20
7.21 Reaction to fire – Components . 20
Annex A (normative) Code designation . 24
Bibliography . 25
---------------------- Page: 5 ----------------------
SIST EN 50264-2-1:2008
EN 50264-2-1:2008 – 4 –
Tables
Table 1 – General data – Cable type (0,6/1 kV unsheathed) . 11
Table 2 – General data – Cable type (1,8/3 kV unsheathed) . 12
Table 3 – General data – Cable type (1,8/3 kV sheathed) . 13
Table 4 – General data – Cable type (3,6/6 kV sheathed) . 14
Table 5 – Schedule of tests for cables . 21
---------------------- Page: 6 ----------------------
SIST EN 50264-2-1:2008
– 5 – EN 50264-2-1:2008
Introduction
The EN 50264 series covers a range of cables, based upon halogen free materials, for use in railway rolling
stock. It is divided into 5 parts under the generic title “Railway applications - Railway rolling stock power and
control cables having special fire performance”:
– Part 1 General requirements;
– Part 2-1 Cables with crosslinked elastomeric insulation – Single core cables;
– Part 2-2 Cables with crosslinked elastomeric insulation – Multicore cables;
– Part 3-1 Cables with crosslinked elastomeric insulation with reduced dimensions – Single core
cables;
– Part 3-2 Cables with crosslinked elastomeric insulation with reduced dimensions – Multicore cables.
Information regarding selection and installation of cables, including current ratings can be found in EN 50355
and EN 50343. The procedure for selection of cable cross-sectional area, including reduction factors for
ambient temperature and installation type, is described in EN 50343.
Special test methods referred to in EN 50264 are given in EN 50305.
The cables in EN 50264-2-1 may also be used in EN 50264-2-2 to build up multicore sheathed cables.
Part 1, “General requirements”, contains a more extensive introduction to EN 50264, and should be read in
conjunction with this Part 2-1.
---------------------- Page: 7 ----------------------
SIST EN 50264-2-1:2008
EN 50264-2-1:2008 – 6 –
1 Scope
EN 50264-2-1 specifies requirements for, and constructions and dimensions of, single core cables of the
following types and voltage ratings:
• 0,6/1 kV unscreened, unsheathed (1 mm² to 400 mm²);
• 1,8/3 kV unscreened, unsheathed (1,5 mm² to 400 mm²);
• 1,8/3 kV unscreened, sheathed (1,5 mm² to 400 mm²);
• 3,6/6 kV unscreened, sheathed (2,5 mm² to 400 mm²).
All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free
sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is
encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a
maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s.
Under fire conditions the cables exhibit special performance characteristics in respect of maximum
permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases.
EN 50264-2-1 should be read in conjunction with Part 1 “General requirements”.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 10002-1 Metallic materials – Tensile testing – Methods of test at ambient temperature
EN 50264-1:2008 Railway applications – Railway rolling stock power and control cables having
special fire performance – Part 1: General requirements
EN 50266-2-4 Common test methods for cables under fire conditions – Test for vertical flame
spread of vertically-mounted bunched wires or cables –
Part 2-4: Procedures – Category C
EN 50266-2-5 Common test methods for cables under fire conditions – Test for vertical flame
spread of vertically-mounted bunched wires or cables –
Part 2-5: Procedures – Small cables – Category D
EN 50305:2002 Railway applications – Railway rolling stock cables having special fire performance
– Test methods
EN 60228 Conductors of insulated cables (IEC 60228)
EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions –
Part 1-2: Test for vertical flame propagation for a single insulated wire or cable –
Procedure for 1 kW pre-mixed flame (IEC 60332-1-2)
EN 60811-1-1:1995 Insulating and sheathing materials of electric and optical cables – Common test
methods – Part 1-1: General application – Measurement of thickness and overall
dimensions – Tests for determining the mechanical properties
(IEC 60811-1-1:1993)
---------------------- Page: 8 ----------------------
SIST EN 50264-2-1:2008
– 7 – EN 50264-2-1:2008
EN 60811-1-2:1995 Insulating and sheathing materials of electric cables – Common test methods –
Part 1-2: General application – Thermal ageing methods
(IEC 60811-1-2:1985 + A1:1989 + corr. May 1986)
EN 60811-1-3:1995 Insulating and sheathing materials of electric and optical cables – Common test
methods – Part 1-3: General application – Methods for determining the density –
Water absorption tests – Shrinkage test (IEC 60811-1-3:1993)
EN 60811-1-4:1995 Insulating and sheathing materials of electric and optical cables – Common test
methods – Part 1-4: General application – Tests at low temperature
(IEC 60811-1-4:1985 + A1:1993 + corr. May 1986)
EN 60811-2-1:1998 Insulating and sheathing materials of electric and optical cables – Common test
methods – Part 2-1: Methods specific to elastomeric compounds – Ozone
resistance, hot set and mineral oil immersion tests
(IEC 60811-2-1:1998)
EN 61034-2 Measurement of smoke density of cables burning under defined conditions –
Part 2: Procedure and requirements (IEC 61034-2)
HD 308 Identification of cores in cables and flexible cords
3 Definitions
For the purposes of this document, the terms and definitions given in EN 50264-1 apply.
4 Rated voltage
The rated voltage for single-core insulated cables shall be as follows:
a) unsheathed: 0,6/1 kV; 1,8/3 kV;
b) sheathed: 1,8/3 kV; 3,6/6 kV.
5 Marking and identification
5.1 Marking of cable
Cables shall be marked with the following:
• manufacturer’s name;
• EN reference;
• voltage rating (U );
o
• conductor size;
• a code designation according to Annex A.
An example of a complete mark is:
XYZ EN 50264-2-1 1800 V 400 FF
The marking shall conform to the requirements of EN 50264-1, Clause 5.
---------------------- Page: 9 ----------------------
SIST EN 50264-2-1:2008
EN 50264-2-1:2008 – 8 –
5.2 Core identification
The core insulation of all cables shall be black unless otherwise specified. If a colour other than black is
specified it shall be a colour in accordance with HD 308. The colour shall be on the surface or throughout the
insulation.
The colour shall be clearly identifiable and durable. Durability shall be checked by the test given in
EN 50305, 10.1.
Conformity with these requirements shall be verified by visual examination.
5.3 Sheath
The sheath shall be black unless otherwise specified.
6 Construction of cables
6.1 General
The cable shall conform to the applicable general requirements given in EN 50264-1 and to the specific
requirements of this part.
Conformity with the requirements shall be checked by inspection and by the tests given in Table 5.
The cable dimensions shall be as given in Tables 1 to 4 as appropriate to the cable type.
6.2 Conductor
Conductors shall be tin-coated annealed copper, class 5, according to EN 60228.
When tested in accordance with EN 10002-1 the minimum average elongation of the wires from the
conductor shall be 15 %, with a minimum value of 10 % for any individual wire.
NOTE It is not necessary to test every individual wire. 5 % of wires or 10 wires, whichever is the least number, should be selected at
random.
6.3 Conductor screening
For cables in Table 4 conductor screening shall be as given in EN 50264-1, 6.1.6.
6.4 Separator
6.4.1 A separator may be used over the conductor if the cable construction does not include a conductor
screen.
6.4.2 A separator may be included between the insulation and the sheath.
6.5 Insulation system
The insulation shall be one or more extruded materials as defined in EN 50264-1 applied so as to meet the
requirements of EI 101 to EI 105.
---------------------- Page: 10 ----------------------
SIST EN 50264-2-1:2008
– 9 – EN 50264-2-1:2008
For single-core unsheathed and sheathed cable:
EI 101 low temperature resistant, oil resistant;
EI 102 extra low temperature resistant, oil resistant;
EI 103 low temperature resistant, extra oil and fuel resistant;
EI 104 extra low temperature resistant, extra oil and fuel resistant.
For sheathed cables:
EI 105 extra low temperature resistant, non oil resistant.
EI 105 may be used as the inner layer of a multilayer insulation system.
To claim extra low temperature performance both insulation and sheath shall be extra low temperature
resistant.
The insulation shall be applied to meet the requirements of EN 50264-1, 6.2.
The insulation thickness shall conform to the specified value g
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.