Automatic electrical controls for household and similar use - Part 2-7: Particular requirements for timers and time switches (IEC 60730-2-7:2008, modified)

In general, this part of IEC 60730 applies to timers and time switches for household and similar use that may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof, including heating, air conditioning and similar applications. This standard is also applicable to individual timers utilized as part of a control system or timers which are mechanically integral with multifunctional controls having non-electrical outlets. This standard does not apply to time-delay switches (TDS) within the scope of IEC 60669-2-3. Throughout this standard, the word “timers” means timers and time switches, unless the type is specifically mentioned. Devices which only indicate time or passage of time are not included. This standard does not apply to multi-functional controls having an integrated timing function which is not capable of being tested as a separate timing device.

Automatische elektrische Regel- und Steuergeräte für den Hausgebrauch und ähnliche Anwendungen - Teil 2-7: Besondere Anforderungen an Zeitsteuergeräte und Schaltuhren (IEC 60730-2-7:2008, modifiziert)

Dispositifs de commande électrique automatiques à usage domestique et analogue - Partie 2-7: Règles particulières pour les minuteries et les minuteries cycliques (CEI 60730-2-7:2008, modifiée)

La CEI 60730-2-7:2008 s'applique aux minuteries et aux minuteries cycliques à usage domestique et analogue qui peuvent utiliser l'électricité, le gaz, le pétrole, un combustible solide, l'énergie thermique solaire, etc., ou une combinaison de ces énergies, y compris des applications de chauffage, climatisation et usages analogues. Cette deuxième édition annule et remplace la première édition publiée en 1990 et son amendement 1 (1994). Cette deuxième édition constitue une révision technique. Cette nouvelle édition incorpore les exigences pour les charges par lampes à filament de tungstène et met à jour la norme par rapport à la CEI 60730-1:1999, Amendement 2 (2007). La présente Partie 2-7 doit être utilisée conjointement avec la CEI 60730-1. Elle a été établie sur la base de la troisième édition de cette norme (1999), de son Amendement 1 (2003) et de son Amendement 2 (2007). Les éditions futures de la CEI 60730-1, ou ses amendements, pourront être pris en considération.

Avtomatske električne krmilne naprave za gospodinjstva in podobno uporabo - 2-7. del: Posebne zahteve za stikalne ure in časovna stikala (IEC 60730-2-7:2008, spremenjen)

Na splošno ta del IEC 60730 velja za stikalne ure in časovna stikala za gospodinjstva in podobno uporabo, ki lahko porabljajo elektriko, plin, nafto, trdno gorivo, solarno termalno energijo ali njihove kombinacije, vključno z ogrevanjem, prezračevanjem in podobnimi rabami. Ta standard prav tako velja za posamične stikalne ure, uporabljene kot del nadzornega sistema ali stikalne ure, ki so mehansko združene v večfunkcijske krmilne naprave, z priključki, ki niso električni.  Ta standard ne velja za stikala s časovno zakasnitvijo (TDS) znotraj področja uporabe IEC 60669-2-3. V tem standardu besedna zveza »stikalne ure« pomeni stiskalne ure in časovna stikala, razen če je vrsta posebej omenjena. Naprave, ki kažejo zgolj čas ali minevanje časa, niso vključene. Ta standard ne velja za večfunkcijske krmilne naprave, ki imajo vgrajeno funkcijo za izbiro časa, ki je ni možno preskusiti kot ločeno napravo za izbiro časa.

General Information

Status
Withdrawn
Publication Date
15-Nov-2010
Withdrawal Date
28-May-2023
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
29-May-2023
Due Date
21-Jun-2023
Completion Date
29-May-2023

Relations

Buy Standard

Standard
EN 60730-2-7:2010
English language
32 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60730-2-7:2010
01-december-2010
1DGRPHãþD
SIST EN 60730-2-7:1995
SIST EN 60730-2-7:1995/A1:1998
SIST EN 60730-2-7:1995/A11:1998
SIST EN 60730-2-7:1995/A12:1998
SIST EN 60730-2-7:1995/A13:2003
SIST EN 60730-2-7:1995/A14:2003
$YWRPDWVNHHOHNWULþQHNUPLOQHQDSUDYH]DJRVSRGLQMVWYDLQSRGREQRXSRUDER
GHO3RVHEQH]DKWHYH]DVWLNDOQHXUHLQþDVRYQDVWLNDOD ,(&
VSUHPHQMHQ
Automatic electrical controls for household and similar use - Part 2-7: Particular
requirements for timers and time switches (IEC 60730-2-7:2008, modified)
Automatische elektrische Regel- und Steuergeräte für den Hausgebrauch und ähnliche
Anwendungen - Teil 2-7: Besondere Anforderungen an Zeitsteuergeräte und Schaltuhren
(IEC 60730-2-7:2008, modifiziert)
Dispositifs de commande électrique automatiques à usage domestique et analogue -
Partie 2-7: Règles particulières pour les minuteries et les minuteries cycliques (CEI
60730-2-7:2008, modifiée)
Ta slovenski standard je istoveten z: EN 60730-2-7:2010
ICS:
97.120 Avtomatske krmilne naprave Automatic controls for
za dom household use
SIST EN 60730-2-7:2010 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60730-2-7:2010

---------------------- Page: 2 ----------------------

SIST EN 60730-2-7:2010

EUROPEAN STANDARD
EN 60730-2-7

NORME EUROPÉENNE
October 2010
EUROPÄISCHE NORM

ICS 97.120 Supersedes EN 60730-2-7:1991 + corr. Mar.2001 + A1:1997 + corr. Mar.2001 + A11:1994 +
corr. Mar.2001 + A12:1993 + corr. Mar.2001 + A13:2003 + A14:2003


English version


Automatic electrical controls for household and similar use -
Part 2-7: Particular requirements for timers and time switches
(IEC 60730-2-7:2008, modified)


Dispositifs de commande électrique Automatische elektrische Regel- und
automatiques à usage domestique et Steuergeräte für den Hausgebrauch und
analogue - ähnliche Anwendungen -
Partie 2-7: Règles particulières pour les Teil 2-7: Besondere Anforderungen an
minuteries et les minuteries cycliques Zeitsteuergeräte und Schaltuhren
(CEI 60730-2-7:2008, modifiée) (IEC 60730-2-7:2008, modifiziert)




This European Standard was approved by CENELEC on 2010-10-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60730-2-7:2010 E

---------------------- Page: 3 ----------------------

SIST EN 60730-2-7:2010
EN 60730-2-7:2010 – 2 –
Foreword
The text of the International Standard IEC 60730-2-7:2008, prepared by IEC TC 72, Automatic
controls for household use, together with the common modifications prepared by the Technical
Committee CENELEC TC 72, Automatic controls for household use, was submitted to the CENELEC
Unique Acceptance Procedure and was approved as EN 60730-2-1 on 2010-10-01.
This document supersedes EN 60730-2-7:1991 + A1:1997 + A11:1994 + A12:1993 + A13:2003 +
A14:2003.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates are fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2011-10-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2013-10-01
This Part 2-7 is to be used in conjunction with EN 60730-1:2000, Automatic electrical controls for
household and similar use – Part 1: General requirements, and any subsequent amendments.
This European Standard has been prepared under a mandate given to CENELEC by the European
Commission and the European Free Trade Association and covers essential requirements of
EC Directive 2004/108/EC. See Annex ZZ.
Annexes ZA and ZZ have been added by CENELEC.
__________

---------------------- Page: 4 ----------------------

SIST EN 60730-2-7:2010
– 3 – EN 60730-2-7:2010
Endorsement notice
The text of the International Standard IEC 60730-2-7:2008 was approved by CENELEC as a
European Standard with agreed common modifications as given below.
COMMON MODIFICATIONS
4 General notes on test
4.1.4 Delete the addition relating to the USA.
4.3.2.1 Delete the addition relating to Canada and the USA.
6 Classification
6.3.6 According to their purpose

6.3.6.101 – TV timer;
Delete the text relating to Canada and the USA.
7 Information
Table 7.2
- item 102 column “Method” Delete “D” and replace with “C"
- Delete the additional notes to Table 7.2.
7.2.9
Delete “In Germany…” and replace with “Where symbols are used …”
11 Constructional requirements
11.4.103 Type 1.S or 2.S action
In the note delete “In Germany”
11.4.104 Type 1.T or 2.T action
In the notes delete “In Germany”
14 Heating
14.101 Temperature stress test
Delete this additional subclause.

---------------------- Page: 5 ----------------------

SIST EN 60730-2-7:2010
EN 60730-2-7:2010 – 4 –
17 Endurance
17.16 Test for particular purpose controls
17.16.101 Tungsten-filament lamp loads
17.16.101.3 Delete the text of this subclause.
17.16.103 TV timers
Delete the subordinate subclauses 17.16.103.1 to 17.16.103.1.5 inclusive and Table 17.16.103.1.2.
21 Fire hazard testing
21.101 Delete this additional subclause.
Annex D Heat, fire and tracking
Delete Annex D.
Annex H Requirements for electronic controls
H.26.11 Electrostatic discharge test
Delete the last sentence relating to Canada and the USA.

---------------------- Page: 6 ----------------------

SIST EN 60730-2-7:2010
– 5 – EN 60730-2-7:2010
Add the following Annexes.
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE  Where an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
Publication Year Title EN/HD Year

IEC 60669-1 (mod) 1998 Switches for household and similar fixed- EN 60669-1 1999
+ A1 (mod) 1999 electrical installations - + A1 2002
+ A2 (mod) 2006 Part 1: General requirements + A2 2008


IEC 61010-1 - Safety requirements for electrical equipment EN 61010-1 -
for measurement, control, and laboratory
use -
Part 1: General requirements

---------------------- Page: 7 ----------------------

SIST EN 60730-2-7:2010
EN 60730-2-7:2010 – 6 –
Annex ZZ
(informative)

Coverage of Essential Requirements of EC Directives
This European Standard has been prepared under a mandate given to CENELEC by the European
Commission and the European Free Trade Association and within its scope the standard covers all
relevant essential requirements as given in Article 1 of Annex I of the EC Directive EMC (2004/108/EC).
Compliance with this standard provides one means of conformity with the specified essential
requirements of the Directive concerned.
WARNING: Other requirements and other EC Directives may be applicable to the products falling
within the scope of this standard.

---------------------- Page: 8 ----------------------

SIST EN 60730-2-7:2010
IEC 60730-2-7
Edition 2.0 2008-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE


Automatic electrical controls for household and similar use –
Part 2-7: Particular requirements for timers and time switches

Dispositifs de commande électrique automatiques à usage domestique et
analogue –
Partie 2-7: Règles particulières pour les minuteries et les minuteries cycliques

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
U
CODE PRIX
ICS 97.120 ISBN 2-8318-9708-4

---------------------- Page: 9 ----------------------

SIST EN 60730-2-7:2010
– 2 – 60730-2-7 © IEC:2008
CONTENTS
FOREWORD.3
1 Scope and normative references .6
2 Definitions .7
3 General requirements .8
4 General notes on tests .8
5 Rating .8
6 Classification.9
7 Information .10
8 Protection against electric shock .11
9 Provision for protective earthing .11
10 Terminals and terminations .11
11 Constructional requirements .11
12 Moisture and dust resistance .12
13 Electric strength and insulation resistance.12
14 Heating .12
15 Manufacturing deviation and drift.13
16 Environmental stress .13
17 Endurance.13
18 Mechanical strength .18
19 Threaded parts and connections.18
20 Creepage distances, clearances and distances through solid insulation .18
21 Fire hazard testing .18
22 Resistance to corrosion .19
23 Electromagnetic compatibility (EMC) requirements – emission .19
24 Components .19
25 Normal operation.19
26 Electromagnetic compatibility (EMC) requirements – immunity .19
27 Abnormal operation .19
28 Guidance on the use of electronic disconnection .19
Annex D (normative) Heat, fire and tracking (applicable in Canada and the USA) .20
Annex H (normative) Requirements for electronic controls .24
Annex AA (normative) Number of cycles, automatic and manual action.26

Figure D.101 – Positioning of electrodes.22
Figure D.102 – Arc resistance test circuit.23

Table 17.16.103.1.2 – Electrical conditions for overload and endurance testing .17
Table D.101 – Sequence of 1-min current steps.22
Table AA.1 – Values for free standing, independently mounted and in-line cord timers
a
and time switches .26

---------------------- Page: 10 ----------------------

SIST EN 60730-2-7:2010
60730-2-7 © IEC:2008 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

AUTOMATIC ELECTRICAL CONTROLS
FOR HOUSEHOLD AND SIMILAR USE –

Part 2-7: Particular requirements for timers and time switches


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60730-2-7 has been prepared by IEC technical committee 72:
Automatic controls for household use.
This second edition cancels and replaces the first edition published in 1990 and its
Amendment 1 (1994). This second edition constitutes a technical revision. This new edition
incorporates requirements for tungsten filament lamp loadings as well as updates the
standard to IEC 60730-1:1999, Amendment 2 (2007).
The text of this standard is based on the following documents:
FDIS Report on voting
72/760/FDIS 72/764/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.

---------------------- Page: 11 ----------------------

SIST EN 60730-2-7:2010
– 4 – 60730-2-7 © IEC:2008
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
This Part 2-7 is to be used in conjunction with IEC 60730-1. It was established on the basis of
the third edition of that standard (1999) and its Amendment 1 (2003) and Amendment 2
(2007). Consideration may be given to future editions of, or amendments to, IEC 60730-1.
This Part 2-7 supplements or modifies the corresponding clauses in IEC 60730-1 so as to
convert that publication into the IEC standard: Particular requirements for timers and time
switches.
Where this Part 2-7 states "addition", "modification" or "replacement", the relevant require-
ment, test specification or explanatory matter in Part 1 should be adapted accordingly.
Where no change is necessary, this Part 2-7 indicates that the relevant clause or subclause
applies.
In the development of a fully international standard, it has been necessary to take into
consideration the differing requirements resulting from practical experience in various parts of
the world and to recognize the variation in national electrical systems and wiring rules.
The “in some countries” notes regarding differing national practice are contained in the following clauses and
subclauses:
– 4.1.4
– 4.3.2
– 6.3.6.101
– Table 7.2, Notes 101 and 103
– 7.2.9
– 11.4.103
– 11.4.104
– 14.101
– 17.16.101.3
– 17.16.103.1
– Table 17.2-2, Notes 101 and 102
– Table 17.2-3, Notes 101 and 102
– 21.101
– Annex D
– H.26.11
In this publication:
1) The following print types are used:
– Requirements proper: in roman type.
– Test specifications: in italic type.
– Explanatory matter: in smaller roman type
2) Subclauses, notes, tables or figures which are additional to those in Part 1 are numbered
starting from 101, additional annexes are lettered AA, BB, etc.
A list of all parts of the IEC 60730 series, under the general title: Automatic electrical controls
for household and similar use, can be found on the IEC website.

---------------------- Page: 12 ----------------------

SIST EN 60730-2-7:2010
60730-2-7 © IEC:2008 – 5 –
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

---------------------- Page: 13 ----------------------

SIST EN 60730-2-7:2010
– 6 – 60730-2-7 © IEC:2008
AUTOMATIC ELECTRICAL CONTROLS
FOR HOUSEHOLD AND SIMILAR USE –

Part 2-7: Particular requirements for timers and time switches



1 Scope and normative references
This clause of Part 1 is applicable except as follows:
1.1 Replacement:
In general, this part of IEC 60730 applies to timers and time switches for household and
similar use that may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a
combination thereof, including heating, air conditioning and similar applications.
This standard is also applicable to individual timers utilized as part of a control system or
timers which are mechanically integral with multifunctional controls having non-electrical
outlets. This standard does not apply to time-delay switches (TDS) within the scope of
1)
IEC 60669-2-3 .
Throughout this standard, the word “timers” means timers and time switches, unless the type is specifically
mentioned.
Devices which only indicate time or passage of time are not included.
This standard does not apply to multi-functional controls having an integrated timing function which is not capable
of being tested as a separate timing device.
1.1.1 This standard applies to the inherent safety, to the operating characteristics where
such are associated with equipment protection and to the testing of automatic electrical
control devices used in appliances and other apparatus, electrical and non-electrical, for
household and similar purposes, but also extended to industrial purposes when no dedicated
product standards exist, such as that for central heating, air conditioning, process heating,
etc.
Timers for equipment not intended for normal household use, but which nevertheless may be
used by the public, such as equipment intended to be used by laymen in shops, in light
industry and on farms, are within the scope of this standard.
This standard is also applicable to timers for appliances within the scope of IEC 60335-1.
This standard does not apply to timers designed exclusively for industrial applications.
Throughout this standard, the word "equipment" means "appliance and equipment".
1.1.2 This standard applies to automatic electrical control devices, mechanically,
electromechanically, electrically or electronically operated, responsive to or controlling
parameters such as temperature, pressure, passage or time, humidity, light, electrostatic
effect, flow or liquid level.
___________
1)
 IEC 60669-2-3:2006, Switches for household and similar fixed electrical installations – Part 2-3: Particular
requirements – Time-delay switches (TDS)

---------------------- Page: 14 ----------------------

SIST EN 60730-2-7:2010
60730-2-7 © IEC:2008 – 7 –
1.1.3 This standard applies to automatic electrical control devices serving the starting of
small motors that are used principally in appliances and apparatus for household and similar
purposes. Such control devices may be built into or be separate from the motor.
1.1.4 This standard applies to non-automatic control devices when such are associated with
automatic control devices.
1.2 Replacement:
This standard applies to controls with a rated voltage not exceeding 690 V and a rated current
not exceeding 63 A.
1.3 Replacement:
This standard does not take into account the response value of an automatic action of a
control, if such a response value is dependent upon the method of mounting the control in the
equipment. If a response value is of significant purpose for the safety of the user or
surroundings, the value defined in the appropriate household equipment standard or as
determined by the manufacturer shall apply.
1.4 Replacement:
This standard applies also to timers incorporating electronic devices, requirements for which
are contained in Annex H.
1.5 Normative references
This subclause of Part 1 applies except as follows:
Addition:
IEC 60669-1:1998, Switches for household and similar fixed-electrical installations – Part 1:
)
2
General requirements
Amendment 1 (1999)
Amendment 2 (2006)

IEC 61010-1, Safety requirements for electrical equipment for measurement, control, and
laboratory use – Part 1: General requirements
2 Definitions
This clause of Part 1 is applicable except as follows:
2.3 Definitions relating to the function of controls
Additional definition:
2.3.101
timing cycle
program including all the switching activities involved in a start-to-finish operation of a
controlled appliance
___________
)
2
There exists a consolidated edition 3.2 (2007) that includes edition 3 and its Amendments 1 and 2.

---------------------- Page: 15 ----------------------

SIST EN 60730-2-7:2010
– 8 – 60730-2-7 © IEC:2008
2.5 Definitions of types of control according to construction
Additional definitions:
2.5.101
plug-in timer
timer or time switch designed for direct plug-in to a socket-outlet
NOTE The plug-in timer is equipped with conductor blades, pins or other means, protruding from the enclosure of
the control or the control body itself, to match the dimensional parameters of the socket-outlet to which the control
will be connected.
2.5.102
TV timer
control for television equipment that can be set by the user, switching very high inrush
currents of a very short duration generated by electrical power supply components and
associated electronic component parts with various electrical characteristics
NOTE Examples are power transformers, electronic tube filaments, large electric capacitors and others in
television receivers, radio and video products.
2.5.103
synchronous timer
timer or a time switch in which the transmission is effected by a device that is time-based on
the frequency of the power supply for the prime mover or the load
2.5.104
hand-wound timer
timer or time switch in which the transmission is provided by actuation
3 General requirements
This clause of Part 1 is applicable.
4 General notes on tests
This clause of Part 1 is applicable except as follows:
4.1.4 Addition:
In the USA, the test in 14.101 is conducted first and the remaining tests are carried out in the order of the clauses
of this standard.
4.3.2.1 Addition:
In Canada and the USA, to reduce testing, a timer that is classified for use with motor loads at more than one rated
voltage is to be tested at the current and voltage in Table 17.2-2 corresponding to the highest rated voltage. If the
current in Table 17.2-2 corresponding to a lower rated voltage is greater than 135 % of the current corresponding
to the highest rated voltage, then the timer is also to be tested at the lower rated voltage. The greater current
involved at a lower rated voltage may necessitate a separate heating test under Clause 14. If more than one test is
conducted, one sample is to be used for each test.
5 Rating
This clause of Part 1 is applicable.

---------------------- Page: 16 ----------------------

SIST EN 60730-2-7:2010
60730-2-7 © IEC:2008 – 9 –
6 Classification
This clause of Part 1 is applicable except as follows:
6.3 According to their purpose
6.3.6 Additional subclause:
6.3.6.101 – TV timer;
In Canada and the USA, timers for use on televisions have to be declared and tested as indicated in this standard.
6.4 According to features of automatic action
6.4.3 Additional subclauses:
6.4.3.101 – a timing action which automatically resets upon loss of the electrical supply
(Type 1.Q or 2.Q);
6.4.3.102 – a timing action which is interrupted upon loss of the electrical supply and
resumes at the point of interruption upon restoration of the electrical supply (Type 1.R or 2.R);
6.4.3.103 – a timing action of a time switch which, after interruption of the electrical supply
for any interval up to the declared period of power reserve, resumes its intended operating
sequence as if no interruption of the supply has occurred (Type 1.S or 2.S);
6.4.3.104 – a timing action with a declared running accuracy in an ambient temperature of
20 °C to 25 °C (Type 1.T or 2.T);
6.4.3.105 – a timing action in which the difference between set time and actual switching
time does not exceed the declared amount (Type 1.U or 2.U).
6.5 According to the degree of protection and control pollution degree
Additional subclause:
6.5.101 According to declared industrial environmental conditions (see IEC 61010-1):
6.10 According to number of cycles of actuation (M) for each manual actuation
Additional subclauses:
6.10.101 – 500 cycles;
6.10.102 – 2 500 cycles;
6.10.103 – 5 000 cycles.
6.15 According to construction
Additional subclause:
6.15.101  – plug-in timer.

---------------------- Page: 17 ----------------------

SIST EN 60730-2-7:2010
– 10 – 60730-2-7 © IEC:2008
7 Information
This clause of Part 1 is applicable except as follows:
7.2 Methods of providing information
7.2.9 Addition:
In Germany, for Type 1.S or 2.S actions, the power reserve is to be marked on the timer by the letter "R", followed
by the duration of the power reserve
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.