Hand-held motor-operated electric tools - Safety -- Part 2-21: Particular requirements for drain cleaners

This clause of Part 1 is applicable, except as follows: Addition: This standard applies to drain cleaners.

Handgeführte motorbetriebene Elektrowerkzeuge - Sicherheit -- Teil 2-21: Besondere Anforderungen für Rohrreinigungsgeräte

Outils électroportatifs à moteur - Sécurité -- Partie 2-21: Règles particulières pour les curettes

Traite de la sécurité des outils dont la tension assignée n'est pas supérieure à 250 V en courant  monophasé alternatif ou courant continu et 440 V en courant alternatif triphasé. Complète ou modifie les articles correspondants de la CEI 60745-1.

Električna ročna orodja - Varnost - 2-21. del: Posebne zahteve za čistilnike odtokov (IEC 60745-2-21:2002, spremenjen)

General Information

Status
Withdrawn
Publication Date
17-Nov-2009
Withdrawal Date
07-Jun-2023
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
07-Jun-2023
Due Date
30-Jun-2023
Completion Date
08-Jun-2023

Relations

Buy Standard

Standard
EN 60745-2-21:2009
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60745-2-21:2009
01-december-2009
1DGRPHãþD
SIST EN 60745-2-21:2008
(OHNWULþQDURþQDRURGMD9DUQRVWGHO3RVHEQH]DKWHYH]DþLVWLOQLNHRGWRNRY
,(&VSUHPHQMHQ
Hand-held motor-operated electric tools - Safety -- Part 2-21: Particular requirements for
drain cleaners
Handgeführte motorbetriebene Elektrowerkzeuge - Sicherheit -- Teil 2-21: Besondere
Anforderungen für Rohrreinigungsgeräte
Outils électroportatifs à moteur - Sécurité -- Partie 2-21: Règles particulières pour les
curettes
Ta slovenski standard je istoveten z: EN 60745-2-21:2009
ICS:
25.140.20 (OHNWULþQDRURGMD Electric tools
91.140.70 Sanitarne naprave Sanitary installations
SIST EN 60745-2-21:2009 en,fr
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60745-2-21:2009

---------------------- Page: 2 ----------------------

SIST EN 60745-2-21:2009

EUROPEAN STANDARD
EN 60745-2-21

NORME EUROPÉENNE
July 2009
EUROPÄISCHE NORM

ICS 25.140.20; 91.140.70 Supersedes EN 60745-2-21:2007


English version


Hand-held motor-operated electric tools -
Safety -
Part 2-21: Particular requirements for drain cleaners
(IEC 60745-2-21:2002, modified)


Outils électroportatifs à moteur -  Handgeführte motorbetriebene
Sécurité - Elektrowerkzeuge -
Partie 2-21: Règles particulières Sicherheit -
pour les curettes Teil 2-21: Besondere Anforderungen
(CEI 60745-2-21:2002, modifiée) für Rohrreinigungsgeräte
(IEC 60745-2-21:2002, modifiziert)




This European Standard was approved by CENELEC on 2009-07-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: Avenue Marnix 17, B - 1000 Brussels


© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60745-2-21:2009 E

---------------------- Page: 3 ----------------------

SIST EN 60745-2-21:2009
- 2 - EN 60745-2-21:2009
Foreword
The text of the International Standard IEC 60745-2-21:2002, prepared by SC 61F (transformed into
IEC TC 116, Safety of hand-held motor-operated electric tools), together with the common
modifications prepared by the Technical Committee CENELEC TC 61F (transformed into TC 116),
was submitted to the Unique Acceptance Procedure and was approved as EN 60745-2-21 on
2007-05-01.
A draft amendment (prAA), extending Annex ZZ to include the new MD 2006/42/EC, was submitted to
the formal vote.
The combined texts were approved by CENELEC as a new edition of EN 60745-2-21 on 2009-07-01.
This European Standard supersedes EN 60745-2-21:2007.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2010-05-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2010-05-01
This standard is divided into two parts:
Part 1: General requirements which are common to most hand-held electric motor operated tools (for
the purpose of this standard referred to simply as tools) which could come within the scope of
this standard;
Part 2: Requirements for particular types of tools which either supplement or modify the requirements
given in Part 1 to account for the particular hazards and characteristics of these specific tools.
This European Standard has been prepared under a mandate given to CENELEC by the European
Commission and the European Free Trade Association and covers essential requirements of
EC Directive 98/37/EC (Machinery Directive), amended by Directive 98/79/EC, and of EC Directive
2006/42/EC. See Annex ZZA and Annex ZZB.
Compliance with the clauses of Part 1 together with this Part 2 provides one means of conforming with
the essential health and safety requirements of the Directives concerned.
Warning: Other requirements and other EC Directives can be applicable to the products falling within
the scope of this standard.
This standard follows the overall requirements of EN ISO 12100-1 and EN ISO 12100-2.
This Part 2-21 is to be used in conjunction with EN 60745-1:2009. When this standard states
"addition", "modification" or "replacement", the relevant text in Part 1 is to be adapted accordingly.
Subclauses, tables and figures which are additional to those in Part 1 are numbered starting from 101.
Subclauses, tables and figures which are additional to those in IEC 60745-2-21 are prefixed “Z”.
Annexes ZZA and ZZB have been added by CENELEC.
NOTE In this standard the following print types are used:
- requirements proper: in roman type;
- test specifications: in italic type;
- explanatory matter: in smaller roman type.
__________

---------------------- Page: 4 ----------------------

SIST EN 60745-2-21:2009
- 3 - EN 60745-2-21:2009
Endorsement notice
The text of the International Standard IEC 60745-2-21:2002 was approved by CENELEC as a
European Standard with agreed common modifications as given below.
COMMON MODIFICATIONS
6 Void
Replace by:
6 Environmental requirements
This clause of Part 1 is applicable except as follows:
6.1.2.4 Modification:
Drain cleaners are suspended at an angle of 45° downwards from the horizontal.
6.1.2.5 Modification:
Drain cleaners are tested at no load in the forward direction. During the test, the drain cleaner cable is
inside the drum.
6.2 Vibration
6.2.4.2 Location of the measurement
Addition:
Figure Z101 shows the positions for drain cleaners.
6.2.6.3 Operating conditions
Modification:
Table Z101 - Operating conditions for drain cleaners
Orientation Drain cleaners are tested at no load in the forward direction.
The drain cleaner is held at an angle of 45° downwards from the horizontal.
Tool bit
The drain cleaner cable is inside the drum.
Grip force Hold the machine with normal gripping force, at the pistol handle and the drum
hand grip surface, avoiding excessive gripping force.
Test cycle
One test cycle is given when the tool is switched on for no load at maximum
speed for more than 10 s and then switched off again.
The measurement is conducted during 10 s within this period.
NOTE  For drain cleaners, no load condition is the worst case for vibration. Typically these tools carry 8 m to 12 m of drain
cleaner cable and a large portion of any vibration is due to the cable in the drum not running true. Also, the highest speed is at
idle and therefore will cause the highest vibration. Little or no vibration is transmitted from the cable being in the drain since the
drain cleaner cable is basically a large spring and acts as a dampener.

---------------------- Page: 5 ----------------------

SIST EN 60745-2-21:2009
- 4 - EN 60745-2-21:2009
6.2.7.2 Declaration of the vibration total value
Addition:
The vibration total value a of the handle with the highest emission and the uncertainty K shall be
h
declared.
21 Construction
Replace by:
This clause of Part 1 is applicable except as follows:
21.Z1 This clause of Part 1 is not applicable.

Add the following figure:


Figure Z101 - Positions of transducers for drain cleaners

---------------------- Page: 6 ----------------------

SIST EN 60745-2-21:2009
- 5 - EN 60745-2-21:2009
Add the following annex:
Annex ZZ
(informative)

Coverage of Essential Requirements of EC Directives
Annex ZZA
(informative)

Coverage of Essential Requirements of Directive 98/37/EC
This European Standard has been prepared under a mandate given to CENELEC by the European
C
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.