SIST EN 62931:2017
(Main)GX16t-5 capped tubular LED lamp - Safety specifications (IEC 62931:2017)
GX16t-5 capped tubular LED lamp - Safety specifications (IEC 62931:2017)
This document specifies the safety and interchangeability requirements together with the test
methods and conditions required to show compliance of non-integrated tubular LED lamps,
intended for general lighting purposes, having:
• a rated wattage up to 70 W,
• a rated voltage up to 190 V ripple free DC,
• GX16t-5 cap as listed in Table 1.
The requirements of this document relate only to type testing.
NOTE 1 Where in this document the term “lamp(s)” is used, it is understood to stand for “non-integrated GX16t-5
capped tubular LED-lamp(s)”, except where it is obviously assigned to other types of lamps.
NOTE 2 The lamp specified in this document is operated with a controlgear specified in Annex B. See Clause 18.
NOTE 3 This document includes photobiological safety.
Zweiseitig gesockelte LED-Lampen mit Passungssystem GX16t-5 - Sicherheitsanforderungen
Lampe à LED tubulaire munie d'un culot GX16t-5 - Spécification de sécurité (IEC 62931:2017)
L'IEC 62931:2017 Le présent document spécifie les exigences de sécurité et d’interchangeabilité, ainsi que les méthodes d’essai et les conditions exigées pour assurer la conformité des lampes à LED tubulaires non intégrées, destinées à l’éclairage général, ayant:
une puissance assignée allant jusqu’à 70 W,
une tension assignée allant jusqu’à 190 V en courant continu lisse,
un culot GX16t-5 tel que répertorié dans le Tableau 1.
Les exigences du présent document concernent uniquement les essais de type.
Dvopolna cevna LED-sijalka GX16t-5 - Varnostne specifikacije (IEC 62931:2017)
Ta dokument določa zahteve za varnost in zamenljivost vključno s preskusnimi metodami in pogoji, ki so potrebni za preverjanje skladnosti neintegriranih cevnih LED-sijalk, ki so namenjene za splošno razsvetljavo ter imajo:
• nazivno moč do 70 W;
• nazivno napetost do 190 V pri enosmernem toku brez valovitosti;
• osnovo GX16t-5, kot je navedeno v preglednici 1.
Zahteve iz tega dokumenta se nanašajo samo na tipsko preskušanje.
OPOMBA 1: Izraz »sijalka« v tem dokumentu označuje »neintegrirane dvopolne cevne LED-sijalke GX16t-5«, razen ko se izraz očitno uporablja za druge vrste sijalk.
OPOMBA 2: Sijalka, določena v tem dokumentu, se upravlja s krmilno napravo, določeno v dodatku B (glej točko 18).
OPOMBA 3: Ta dokument zajema fotobiološko varnost.
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 62931:2017
01-september-2017
Dvopolna cevna LED-sijalka GX16t-5 - Varnostne specifikacije (IEC 62931:2017)
GX16t-5 capped tubular LED lamp - Safety specifications (IEC 62931:2017)
Lampe à LED tubulaire munie d'un culot GX16t-5 - Spécification de sécurité (IEC
62931:2017)
Ta slovenski standard je istoveten z: EN 62931:2017
ICS:
29.140.01 Žarnice na splošno Lamps in general
SIST EN 62931:2017 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 62931:2017
---------------------- Page: 2 ----------------------
SIST EN 62931:2017
EUROPEAN STANDARD EN 62931
NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2017
ICS 29.140.10
English Version
GX16t-5 capped tubular led lamp -
Safety specifications
(IEC 62931:2017)
Lampe à led tubulaire munie d'un culot GX16t-5 - Zweiseitig gesockelte LED-Lampen mit Passungssystem
Spécifications de sécurité GX16t-5 - Sicherheitsanforderungen
(IEC 62931:2017) (IEC 62931:2017)
This European Standard was approved by CENELEC on 2017-06-01. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 62931:2017 E
---------------------- Page: 3 ----------------------
SIST EN 62931:2017
EN 62931:2017
European foreword
The text of document 34A/1957/FDIS, future edition 1 of IEC 62931, prepared by SC 34A "Lamps", of
IEC/TC 34 "Lamps and related equipment" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN 62931:2017.
The following dates are fixed:
• latest date by which the document has to be implemented at (dop) 2018-03-01
national level by publication of an identical national
standard or by endorsement
• latest date by which the national standards conflicting with (dow) 2020-06-01
the document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association.
Endorsement notice
The text of the International Standard IEC 62931:2017 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60081 NOTE Harmonized as EN 60081.
IEC 60529:1989 NOTE Harmonized as EN 60529:1991 (not modified)
+ A1:1999 + A1:2000 (not modified)
+ A2:2013 + A2:2013 (not modified).
IEC 60921 NOTE Harmonized as EN 60921.
IEC 61195 NOTE Harmonized as EN 61195.
IEC 61347-2-13 NOTE Harmonized as EN 61347-2-13.
IEC 62471 NOTE Harmonized as EN 62471.
2
---------------------- Page: 4 ----------------------
SIST EN 62931:2017
EN 62931:2017
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is
available here: www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60061-1 - Lamp caps and holders together with EN 60061-1 -
gauges for the control of
interchangeability and safety - Part 1:
Lamp caps
IEC 60061-2 - Lamp caps and holders together with EN 60061-2 -
gauges for the control of
interchangeability and safety - Part 2:
Lampholders
IEC 60061-3 - Lamp caps and holders together with EN 60061-3 -
gauges for the control of
interchangeability and safety - Part 3:
Gauges
IEC 60061-4 - Lamp caps and holders together with EN 60061-4 -
gauges for the control of
interchangeability and safety - Part 4:
Guidelines and general information
IEC 60360 - Standard method of measurement of lamp EN 60360 -
cap temperature rise
IEC 60400 2008 Lampholders for tubular fluorescent lamps EN 60400 2008
and starterholders
+ A1 2011 + A1 2011
+ A2 2014 + A2 2014
IEC 60598-1 (mod) 2014 Luminaires - Part 1: General requirements EN 60598-1 2015
and tests
1)
EN 60695-2-10 2001
IEC 60695-2-10 2000 Fire hazard testing - Part 2-10:
Glowing/hot-wire based test methods -
Glow-wire apparatus and common test
procedure
1) EN 60695-2-10:2001 is superseded by EN 60695-2-10:2013, which is based on IEC 60695-2-10:2013.
3
---------------------- Page: 5 ----------------------
SIST EN 62931:2017
EN 62931:2017
Publication Year Title EN/HD Year
IEC 60838-2-3 - Miscellaneous lampholders - Part 2-3: EN 60838-2-3 -
Particular requirements - Lampholders for
double-capped linear LED lamps
2)
EN 60695-2-11 2001
IEC 60695-2-11 2000 Fire hazard testing - Part 2-11:
Glowing/hot-wire based test methods -
Glow-wire flammability test method for
end-products
IEC 61347-1 2015 Lamp controlgear - Part 1: General and EN 61347-1 2015
safety requirement
IEC 62031 - LED modules for general lighting - Safety EN 62031 -
specifications
IEC 62504 - General lighting - Light emitting diode EN 62504 -
(LED) products and related equipment -
Terms and definitions
IEC/TR 62778 2014 Application of IEC 62471 for the - -
assessment of blue light hazard to light
sources and luminaires
ISO 4046-4 2016 Paper, board, pulps and related terms - - -
Vocabulary - Part 4: Paper and board
grades and converted products
2) EN 60695-2-11:2001 is superseded by EN 60695-2-11:2014, which is based on IEC 60695-2-11:2014.
4
---------------------- Page: 6 ----------------------
SIST EN 62931:2017
IEC 62931
®
Edition 1.0 2017-01
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
GX16t-5 capped tubular led lamp – Safety specifications
Lampe à led tubulaire munie d’un culot GX16t-5 – Spécifications de sécurité
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 29.140.10 ISBN 978-2-8322-3858-5
Warning! Make sure that you obtained this publication from an authorized distributor.
Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 7 ----------------------
SIST EN 62931:2017
– 2 – IEC 62931:2017 © IEC 2017
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 7
4 General requirements and general test requirements . 8
5 Marking . 8
5.1 Marking on the lamp . 8
5.2 Marking on the packing or in instructions . 9
5.3 Durability and legibility of marking . 9
6 Interchangeability . 10
6.1 Dimensional requirements of caps . 10
6.2 Mass . 10
6.3 Dimensions . 10
6.3.1 General . 10
6.3.2 Dimensions at 25 °C (non-operating) . 10
6.3.3 Dimension A at maximum ambient temperature (operating) . 10
6.3.4 Dimension A at minimum ambient temperature (non-operating) . 11
6.4 Temperature . 11
6.5 Lamp bowing (sag) . 11
6.6 Pin connection . 12
7 Protection against accidental contact with live parts . 12
8 Insulation resistance and electric strength after humidity treatment . 14
8.1 General . 14
8.2 Insulation resistance . 14
8.3 Electric strength . 14
9 Mechanical requirements for caps . 14
9.1 General . 14
9.2 Torque test on unused lamps . 14
9.3 Torque test after heat treatment . 15
9.4 Live part accessibility after mechanical tests . 15
10 Cap temperature rise . 15
11 Resistance to heat . 15
12 Resistance to flame and ignition . 16
13 Resistance to heat of insulating material of cap . 17
14 Fault conditions . 17
14.1 General . 17
14.2 Testing under extreme electrical conditions . 17
14.3 Short-circuit across capacitors . 18
14.4 Fault conditions across electronic components . 18
14.5 Compliance . 18
15 Creepage distances and clearances . 18
16 Ingress protection . 19
16.1 Aim of the test . 19
16.2 Thermal endurance . 19
16.3 IP testing . 19
---------------------- Page: 8 ----------------------
SIST EN 62931:2017
IEC 62931:2017 © IEC 2017 – 3 –
17 Photobiological safety . 19
17.1 UV radiation . 19
17.2 Blue light hazard . 19
17.3 Infrared radiation . 19
18 Information for controlgear design . 20
19 Information for lampholder design . 20
20 Information for luminaire design . 20
Annex A (normative) Test method for lamp cap temperature rise for GX16t-5 lamps . 21
Annex B (informative) Information for controlgear design . 22
B.1 Guidelines for safe lamp operation . 22
B.2 General . 22
B.3 Protection against electric shock . 22
B.3.1 No-load condition. 22
B.3.2 Overload condition, normal condition and short-circuit condition . 22
Annex C (informative) Information for luminaire design . 24
C.1 General . 24
C.2 Thermal variation of lamp length . 24
C.3 Lampholders . 24
Annex D (normative) Dimensions and information to electrical characteristics . 25
Bibliography . 31
Figure 1 – Lamp not suitable for use under dust and moisture . 9
Figure 2 – Standard test finger (according to IEC 60529) . 13
Figure 3 – Ball-pressure test apparatus . 16
Table 1 – Sheet references of IEC 60061-1 and IEC 60061-3 . 10
Table 2 – Test voltages for caps . 14
Table B.1 – No load output voltage of the controlgear . 22
---------------------- Page: 9 ----------------------
SIST EN 62931:2017
– 4 – IEC 62931:2017 © IEC 2017
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
GX16t-5 CAPPED TUBULAR LED LAMP –
SAFETY SPECIFICATIONS
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in
addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses
arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62931 has been prepared by subcommittee 34A: Lamps, of IEC
technical committee 34: Lamps and related equipment.
The text of this standard is based on the following documents:
FDIS Report on voting
34A/1957/FDIS 34A/1974/RVD
Full information on the voting for the approval of this International Standard can be found in the
report on voting indicated in the above table.
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.
In this standard, the following type is used:
– compliance statements: in italic type.
---------------------- Page: 10 ----------------------
SIST EN 62931:2017
IEC 62931:2017 © IEC 2017 – 5 –
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
---------------------- Page: 11 ----------------------
SIST EN 62931:2017
– 6 – IEC 62931:2017 © IEC 2017
GX16t-5 CAPPED TUBULAR LED LAMP –
SAFETY SPECIFICATIONS
1 Scope
This document specifies the safety and interchangeability requirements together with the test
methods and conditions required to show compliance of non-integrated tubular LED lamps,
intended for general lighting purposes, having:
• a rated wattage up to 70 W,
• a rated voltage up to 190 V ripple free DC,
• GX16t-5 cap as listed in Table 1.
The requirements of this document relate only to type testing.
NOTE 1 Where in this document the term “lamp(s)” is used, it is understood to stand for “non-integrated GX16t-5
capped tubular LED-lamp(s)”, except where it is obviously assigned to other types of lamps.
NOTE 2 The lamp specified in this document is operated with a controlgear specified in Annex B. See Clause 18.
NOTE 3 This document includes photobiological safety.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60061-1, Lamp caps and holders together with gauges for the control of interchangeability
and safety – Part 1: Lamp caps
IEC 60061-2, Lamp caps and holders together with gauges for the control of interchangeability
and safety – Part 2: Lampholders
IEC 60061-3, Lamp caps and holders together with gauges for the control of interchangeability
and safety – Part 3: Gauges
IEC 60061-4, Lamp caps and holders together with gauges for the control of interchangeability
and safety – Part 4: Guidelines and general information
IEC 60360, Standard method of measurement of lamp cap temperature rise
IEC 60400:2008, Lampholders for tubular fluorescent lamps and starterholders
IEC 60400:2008/AMD1:2011
IEC 60400:2008/AMD2:2014
IEC 60598-1:2014, Luminaires – Part 1: General requirements and tests
IEC 60695-2-10:2000, Fire hazard testing – Part 2-10: Glowing/hot-wire based test methods;
1
Glow-wire apparatus and common test procedure
1
Withdrawn
---------------------- Page: 12 ----------------------
SIST EN 62931:2017
IEC 62931:2017 © IEC 2017 – 7 –
IEC 60838-2-3, Miscellaneous lampholders – Part 2-3: Particular requirements – Lampholders
for double-capped linear LED lamps
IEC 60695-2-11:2000, Fire hazard testing – Part 2-11: Glowing/hot-wire based test methods –
2
Glow-wire flammability test method for end products (GWEPT)
IEC 61347-1:2015, Lamp controlgear – Part 1: General and safety requirements
IEC 62031, LED modules for general lighting – Safety specifications
IEC 62504, General lighting – Light emitting diode (LED) products and related equipment –
Terms and definitions
IEC TR 62778:2014, Application of IEC 62471 for the assessment of blue light hazard to light
sources and luminaires
ISO 4046-4:2016, Paper, board, pulps and related terms – Vocabulary – Part 4: Paper and board
grades and converted products
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 62504 and IEC 62031,
and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
non-integrated double-capped LED lamp
tubular LED lamp having two caps which needs a separate controlgear to operate
3.2
GX16t-5 capped LED lamp
non-integrated tubular LED lamp(s) equipped with the GX16t-5 cap system
3.3
cap temperature rise
∆ t
s
surface temperature rise (above ambient) of the lamp cap
3.4
ultraviolet hazard efficacy of luminous radiation
K
S,v
quotient of an ultraviolet hazard quantity to the corresponding photometric quantity
Note 1 to entry: The ultraviolet hazard efficacy of luminous radiation is obtained by weighting the spectral power
distribution of the lamp with the UV hazard function SUV(λ). Information about the relevant UV hazard function is
given in IEC 62471. It only relates to possible hazards regarding UV exposure of human beings. It does not deal with
the possible influence of optical radiation on materials, such as mechanical damage or discoloration.
Note 2 to entry: Ultraviolet hazard efficacy of luminous radiation is expressed in mW/klm.
2
Withdrawn
---------------------- Page: 13 ----------------------
SIST EN 62931:2017
– 8 – IEC 62931:2017 © IEC 2017
4 General requirements and general test requirements
4.1 The lamps shall be so designed and constructed that in normal use they function safely
causing no danger to the user or surroundings.
In general, compliance is checked by carrying out all the tests specified.
4.2 GX16t-5 capped LED lamps shall normally not be opened for any tests. In the case of
doubt based on the inspection of the lamp and the examination of the circuit diagram, and in
agreement with the manufacturer or responsible vendor, either the output terminals shall be
short-circuited or, in agreement with the manufacturer, lamps specially prepared so that a fault
condition can be simulated shall be submitted for testing (see Clause 14). Opened lamps or
inspection of internal component parts of the lamp may be required to verify conformity with
Clauses 11, 12 and 13.
4.3 In general, all tests are carried out on each type of lamp or, where a range of similar lamps
is involved, for each power in the range or on a representative selection from the range, as
agreed with the manufacturer.
4.4 When the lamp fails during one of the tests without any fire, smoke and flammable gas, it
is regarded as a safe failure and shall be replaced in the test. Further requirements on failing
safely are given in Clause 14.
4.5 Internal wiring shall be carried out according to the requirements in IEC 60598-1:2014,
5.3.
4.6 For the construction of the electrical circuit, the requirements in IEC 61347-1:2015, 15.1
and 15.2 shall be taken into account and for the construction of other parts, the requirements in
IEC 60598-1:2014, 4.11, 4.12 and 4.25 shall be taken into account.
NOTE Temperature conditions can be modified in the regional standards according to the climate there.
5 Marking
5.1 Marking on the lamp
Lamps shall be clearly and durably marked with the following marking:
a) mark of origin (this may take the form of a trademark, the manufacturer’s name or the name
of the responsible vendor);
b) lamp identification;
c) rated wattage (units: “W” or “watts”);
d) Information on the ingress of dust and water, see Figure 1:
– for lamps which do not comply with 16.3.
---------------------- Page: 14 ----------------------
SIST EN 62931:2017
IEC 62931:2017 © IEC 2017 – 9 –
EC
IEC 60417-6179:2012-10
Figure 1 – Lamp not suitable for use under dust and moisture
5.2 Marking on the packing or in instructions
In addition, the following information shall be given by the lamp manufacturer on immediate lamp
wrapping (or container) or in instructions.
a) Mark of origin (this may take the form of a trademark, the manufacturer’s name or the name
of the responsible vendor);
b) Lamp identification;
c) rated wattage (units: “W” or “watts”);
d) Rated lamp current (units: “A” or “ampere”);
e) Nominal dimensions;
– unit: mm;
– example of marking: 1 200 mm × 26 mm.
f) Rated ambient temperature range of the lamp;
The ambient temperature range for which the lamp is rated shall be declared. Where the
minimum ambient temperature of the range is higher than –20 °C or the maximum ambient
temperature of the range lower than +60 °C the instruction manual for the lamp shall contain
the following information.
“This lamp may not be suitable for use in all applications where a traditional fluorescent lamp
has been used. The temperature range of this lamp is more restricted. In cases of doubt
regarding the suitability of the applicat
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.