SIST EN 13732:2013
(Main)Food processing machinery - Bulk milk coolers on farms - Requirements for performance, safety and hygiene
Food processing machinery - Bulk milk coolers on farms - Requirements for performance, safety and hygiene
This European Standard specifies requirements for design, performance, safety and hygiene of refrigerated bulk milk coolers and the related methods of test. This standard deals with all significant hazards, hazardous situations and events relevant to bulk milk coolers on farms, when they are used as intended and under the conditions of misuse which are reasonably foreseeable by the manufacturer (see Clause 4). It applies to refrigerated bulk milk tanks with air cooled condensing units and automatic control intended for installation on farms or at milk collecting points. It applies to tanks for two milkings (24 h), four milkings (48 h) and six milkings (72 h), in which the cooling takes place totally (non-pre-cooled milk) or partially (in case of pre-cooled milk) within the tank. Performance requirements in 5.5.1.2.1 and 5.5.1.2.2 do not apply to tanks in combination with instant cooling or in association with a continuous system of milking (e.g. milking with robot).
Nahrungsmittelmaschinen - Behälter-Milchkühlanlagen für Milcherzeugerbetriebe - Anforderungen für Leistung, Sicherheit und Hygiene
1.1 Diese Europäische Norm legt die Anforderungen für die Konstruktion, Leistung, Sicherheit und Hygiene von Behälter-Milchkühlanlagen und die damit verbundenen Prüfverfahren fest.
Diese Norm behandelt alle signifikanten Gefährdungen, Gefährdungssituationen und Gefährdungsereignisse, die auf Behälter-Milchkühlanlagen für Milcherzeugerbetriebe zutreffen, wenn sie bestimmungsgemäß und unter Bedingungen von durch den Hersteller vernünftigerweise vorhersehbaren Fehlanwendungen verwendet werden (siehe Abschnitt 4).
Sie gilt für Behälter-Milchkühlanlagen mit luftgekühlten Verflüssigersätzen und automatischer Steuerung, die für die Aufstellung in Milcherzeugerbetrieben oder in Milchsammelstellen bestimmt sind. Sie gilt für Kühltanks für zwei Gemelke (24 Stunden), vier Gemelke (48 Stunden) und sechs Gemelke (72 Stunden), bei denen die Kühlung vollständig (nicht vorgekühlte Milch) oder teilweise (im Fall von vorgekühlter Milch) innerhalb des Kühltanks erfolgt.
Die Leistungsanforderungen in 5.5.1.2.1 und 5.5.1.2.2 gelten nicht für Tanks in Verbindung mit Durchlauf-kühlen oder in Verbindung mit einer kontinuierlichen Melkanlage (z. B. Melkautomat).
1.2 Diese Europäische Norm gilt nicht für:
- mobile Tanks;
- Tanks, die zur Entleerung gekippt werden;
- die Ausrüstung für die Befüllung des Tanks mit Milch;
- die Ausrüstung für das Vorkühlen oder Durchlaufkühlen der Milch;
- die Gefährdungen durch die Verwendung anderer Energie als Elektrizität;
- den Druckaspekt von Vakuumtanks.
1.3 Lärm wird nicht als signifikante Gefährdung für Behälter-Milchkühlanlagen angesehen. Die vorliegende Norm enthält in 7.1 und Anhang A Informationen über die Erklärung des Herstellers zum Geräuschemissions-pegel des Kühlbehälters.
1.4 Diese Norm enthält keine Anforderungen an die Kühltankkalibrierung, die für Abrechnungszwecke benutzt werden.
1.5 Diese Norm gilt nicht für Behälter-Milchkühlanlagen für Milcherzeugerbetriebe, die vor dem Datum ihrer Veröffentlichung als EN hergestellt wurden.
Machines pour les produits alimentaires - Refroidisseurs de lait en vrac à la ferme - Prescriptions pour les performances, la sécurité et l'hygiène
1.1 La présente Norme européenne spécifie les prescriptions relatives à la conception, aux performances, à la sécurité et à l'hygiène des refroidisseurs de lait en vrac avec groupe frigorifique ainsi que les méthodes d'essai correspondantes.
La présente norme traite tous les phénomènes dangereux, situations et événements dangereux significatifs spécifiques aux refroidisseurs de lait en vrac à la ferme, lorsqu'ils sont utilisés normalement et dans les conditions de mauvais usage raisonnablement prévisible par le constructeur (voir Article 4).
Elle s'applique aux refroidisseurs de lait en vrac avec groupe frigorifique refroidi par air et commande automatique, destinés à être installés dans des fermes ou dans des centres de ramassage du lait. Elle s’applique aux refroidisseurs « deux traites » (24 h), « quatre traites » (48 h) et « six traites » (72 h), dans lesquels le refroidissement s'effectue entièrement (lait non prérefroidi) ou partiellement (lait prérefroidi) dans la cuve.
Les prescriptions de performance du 5.5.1.2.1 et du 5.5.1.2.2 ne s'appliquent pas aux refroidisseurs associés à un équipement de refroidissement instantané ou associées à un système de traite en continu (par exemple traite effectuée par un robot).
1.2 La présente Norme européenne ne couvre pas :
les refroidisseurs mobiles ;
les refroidisseurs prévus pour être basculés lors de la vidange ;
l'équipement d'introduction du lait dans le refroidisseur ;
l'équipement de prérefroidissement ou de refroidissement instantané du lait ;
les phénomènes dangereux engendrés par l'utilisation d'une énergie autre qu'électrique ;
la question de la pression des refroidisseurs sous vide.
1.3 Le bruit n'est pas considéré comme un phénomène dangereux significatif mais comme un phénomène dangereux pertinent pour les refroidisseurs de lait en vrac. Par conséquent, la présente norme inclut, au 7.1 et à l'Annexe A, les informations relatives à la déclaration par le constructeur du niveau sonore du refroidisseur.
1.4 La présente norme ne couvre pas les prescriptions de jaugeage du refroidisseur à utiliser comme système de paiement.
1.5 La présente norme ne s’applique pas aux refroidisseurs de lait en vrac à la ferme construits avant sa date de publication en tant que norme EN.
Stroji za predelavo hrane - Hladilniki za shranjevanje namolzenega mleka - Zahteve za zmogljivost, varnost in higieno
Ta evropski standard določa zahteve za načrtovanje, delovanje, varnost in higieno hladilnikov za shranjevanje namolzenega mleka in povezanih metod preskusov. Ta standard obravnava vsa večja tveganja, nevarne situacije in nevarne dogodke v zvezi s hladilniki za shranjevanje namolzenega mleka, kadar se uporabljajo v skladu z njihovim namenom in pod pogoji pričakovane nepravilne uporabe, ki jih določa proizvajalec (glej točko 4). Uporablja se tudi za hlajene rezervoarje za shranjevanje mleka z zračno hlajenimi kondenzacijskimi enotami in avtomatskim upravljanjem, namenjene za uporabo na kmetijah ali točkah za zbiranje mleka. Uporablja se za rezervoarje za dve molži (24 h), štiri molže (48 h) in šest molž (72 h), v katerih hlajenje poteka v celoti (brez predhodnega hlajenja mleka) ali delno (v primeru predhodnega hlajenja mleka) v rezervoarju. Zahteve za delovanje v točkah 5.5.1.2.1 in 5.5.1.2.2 se ne uporabljajo za rezervoarje v kombinaciji z instantnim hlajenjem ali v povezavi s sistemom stalne molže (npr. molža z robotom).
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Stroji za predelavo hrane - Hladilniki za shranjevanje namolzenega mleka - Zahteve za zmogljivost, varnost in higienoNahrungsmittelmaschinen - Behälter-Milchkühlanlagen für Milcherzeugerbetriebe - Anforderungen für Leistung, Sicherheit und HygieneMachines pour les produits alimentaires - Refroidisseurs de lait en vrac à la ferme - Prescriptions pour les performances, la sécurité et l'hygièneFood processing machinery - Bulk milk coolers on farms - Requirements for performance, safety and hygiene67.260Tovarne in oprema za živilsko industrijoPlants and equipment for the food industry65.040.20Buildings and installations for processing and storage of agricultural produceICS:Ta slovenski standard je istoveten z:EN 13732:2013SIST EN 13732:2013en,fr,de01-november-2013SIST EN 13732:2013SLOVENSKI
STANDARDSIST EN 13732:2003+A2:20091DGRPHãþD
SIST EN 13732:2013
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13732
July 2013 ICS 65.040.10; 67.260 Supersedes EN 13732:2002+A2:2009English Version
Food processing machinery - Bulk milk coolers on farms - Requirements for performance, safety and hygiene
Machines pour les produits alimentaires - Refroidisseurs de lait en vrac à la ferme - Prescriptions pour les performances, la sécurité et l'hygiène
Nahrungsmittelmaschinen - Behältermilchkühlanlagen für Milcherzeugerbetriebe - Anforderungen an Leistung, Sicherheit und Hygiene This European Standard was approved by CEN on 7 June 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13732:2013: ESIST EN 13732:2013
EN 13732:2013 (E) 2 Contents
Page Foreword . 4 Introduction . 5 1 Scope . 6 2 Normative references . 7 3 Terms and definitions . 8 4 List of significant hazards . 12 5 Safety requirements and/or protective measures — Performance . 13 5.1 General . 13 5.2 Mechanical hazards . 13 5.3 Electrical hazards . 14 5.4 Thermal hazards and hazards generated by materials and substances used . 14 5.5 Hygiene . 14 5.6 Ergonomics . 19 5.7 Provisions for maintenance . 20 5.8 Other general requirements for tanks . 20 5.9 Additional requirements for special tanks - Ice bank tanks . 22 6 Verification and tests . 23 7 Information for use . 26 7.1 General . 26 7.2 Warning signs . 26 7.3 Instruction handbook for the user . 27 7.4 Instructions check list . 28 7.5 Installation and maintenance instructions . 29 7.6 Dismantling instructions. 30 7.7 Minimum marking. 30 Annex A (normative)
Noise test code (Grade 2 of accuracy) . 32 A.1 General . 32 A.2 Emission sound pressure level determination . 32 A.3 Mounting conditions . 32 A.4 Operating conditions . 33 A.5 Measurement uncertainties . 33 A.6 Information to be recorded . 33 A.7 Information to be reported . 34 A.8 Declaration and verification of the noise emission values . 34 Annex B (normative)
Electrical requirements for bulk milk coolers according to EN 60204-1:2006 . 36 B.1 Safety requirements related to electromagnetic phenomena . 36 B.2 Protection against electric shock . 36 B.3 Ambient air temperature . 36 B.4 Supply disconnecting device . 36 B.5 Power circuits . 36 B.6 Overload protection of motors . 36 B.7 Control circuit supply . 37 B.8 Emergency stop devices. 37 B.9 Degrees of protection . 37 B.10 Markings of control equipment . 37 SIST EN 13732:2013
EN 13732:2013 (E) 3 Annex C (normative)
Electrical requirements for bulk milk coolers according to EN 60335-1:2002 . 38 C.1 General . 38 C.2 Normal operation. 38 C.3 General conditions for the tests . 38 C.4 Classification . 38 C.5 Input and current . 38 C.6 Heating. 39 C.7 Leakage current and electric strength at operating temperature. 39 C.8 Moisture resistance . 40 C.9 Abnormal operation . 40 C.10 Stability and mechanical hazards . 42 C.11 Mechanical strength . 42 C.12 Supply connection and external flexible cords . 42 C.13 Provision for earthing . 43 C.14 Creepage distances, clearances and solid insulation . 43 C.15 Resistance to heat and fire . 43 Annex D (normative)
Test for cooling, thermal insulation, mixing tests . 44 D.1 General . 44 D.2 Performance tests . 45 Annex E (normative)
Test for cleanability and cleaning performance . 57 E.1 Introduction . 57 E.2 Definitions and steps for the test . 57 E.3 Installation of the tank to be tested . 58 E.4 Preparation of soiling milk (solution A) . 58 E.5 Soiling of the tank . 59 E.6 Automatic cleaning of the tank . 59 E.7 Tank rest phase . 60 E.8 Visual assessment of internal tank surfaces and equipment . 60 E.9 Taking method for bacteriological examinations . 60 E.10 Visual assessment of internal tank surfaces and equipment . 62 E.11 Bacteriological examination . 62 E.12 Chemical examination . 63 E.13 Interpretation of results . 64 Annex F (normative)
Sampling methods for milk mixing tests . 65 Annex G (normative)
Equipment and installation for the tests for cleanability and cleaning performance required in Annex E . 66 G.1 Equipment and installation for the examination dealing with the tank outlet . 66 G.2 Equipment and installation for the examination dealing with the internal tank surfaces and equipment . 67 Annex ZA (informative)
Relationship between this European Standard and the Essential Requirements of EU Directive 2006/42/CE . 71 Bibliography . 72
SIST EN 13732:2013
EN 13732:2013 (E) 4 Foreword This document (EN 13732:2013) has been prepared by Technical Committee CEN/TC 153 “Machinery intended for use with foodstuffs and feed”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2014, and conflicting national standards shall be withdrawn at the latest by January 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 13732:2002+A2:2009. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. The main changes compared to the previous edition are the following ones: a) specification of the scope: 1) pre-cooled milk is taken into account; 2) other energy than electrical energy as well as the pressure aspect of vacuum tanks are excluded; b) updating of normative references; c) specification of the electrical requirements (5.3 was revised and Annexes B and C were added); d) addition of subclause 7.2 "Warning signs”; e) specification of the noise test code; f) editorial modifications. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
SIST EN 13732:2013
EN 13732:2013 (E) 5 Introduction This document is a type C standard as stated in EN ISO 12100. The machinery concerned and the extent to which hazards, hazardous situations and events are covered are indicated in the scope of this document. When provisions of this type C standard are different from those which are stated in type A or B standards, the provisions of this type C standard take precedence over the provisions of the other standards, for machines that have been designed and built according to the provisions of this type C standard. SIST EN 13732:2013
EN 13732:2013 (E) 6 1 Scope 1.1 This European Standard specifies requirements for design, performance, safety and hygiene of refrigerated bulk milk coolers and the related methods of test. This standard deals with all significant hazards, hazardous situations and events relevant to bulk milk coolers on farms, when they are used as intended and under the conditions of misuse which are reasonably foreseeable by the manufacturer (see Clause 4). It applies to refrigerated bulk milk tanks with air cooled condensing units and automatic control intended for installation on farms or at milk collecting points. It applies to tanks for two milkings (24 h), four milkings (48 h) and six milkings (72 h), in which the cooling takes place totally (non-pre-cooled milk) or partially (in case of pre-cooled milk) within the tank. Performance requirements in 5.5.1.2.1 and 5.5.1.2.2 do not apply to tanks in combination with instant cooling or in association with a continuous system of milking (e.g. milking with robot). 1.2 This European Standard does not cover: — mobile tanks; — tanks intended to be tilted for drainage; — equipment for delivering the milk to the tank; — equipment for pre-cooling or instant cooling of the milk; — the hazards due to the use of other energy than electrical energy; — pression aspect of vacuum tanks. 1.3 Noise is not considered to be a significant hazard, but a relevant one for bulk milk coolers. This standard therefore includes information in 7.1 and in Annex A concerning the manufacturer's declaration of the noise emission level of the cooler. 1.4 This standard does not cover the calibration requirements for the tank to be used as a system for payment purpose. 1.5 This standard is not applicable to bulk milk coolers on farms which are manufactured before the date of its publication as an EN. SIST EN 13732:2013
EN 13732:2013 (E) 7 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 378-1:2008+A2:2012, Refrigerating systems and heat pumps — Safety and environmental requirements — Part 1: Basic requirements, definitions, classification and selection criteria EN 378-2, Refrigerating systems and heat pumps — Safety and environmental requirements — Part 2: Design, construction, testing, marking and documentation EN 378-3, Refrigerating systems and heat pumps — Safety and environmental requirements — Part 3: Installation site and personal protection EN 378-4, Refrigerating systems and heat pumps — Safety and environmental requirements — Part 4: Operation, maintenance, repair and recovery EN 1005-3, Safety of machinery — Human physical performance — Part 3: Recommended force limits for machinery operation EN 1088, Safety of machinery — Interlocking devices associated with guards — Principles for design and selection EN 1672-2:2005+A1:2009, Food processing machinery — Basic concepts — Part 2: Hygiene requirements EN 10088-2:2005, Stainless steels - Part 2: Technical delivery conditions for sheet/plate and strip of corrosion resisting steels for general purposes EN 60204-1:2006, Safety of machinery — Electrical equipment of machines — Part 1: General requirements (IEC 60204-1:2005, modified) EN 60335-1:2002, Household and similar electrical appliances — Safety — Part 1: General requirements (IEC 60335-1:2001, modified) EN 60335-2-34, Household and similar electrical appliances — Safety — Part 2-34: Particular requirements for motor-compressors (IEC 60335-2-34) EN 60529:1991,1) Degrees of protection provided by enclosures (IP Code) (IEC 60529:1989) EN 61310-1, Safety of machinery — Indication, marking and actuation — Part 1: Requirements for visual, acoustic and tactile signals (IEC 61310-1) EN ISO 1211, Milk — Determination of fat content — Gravimetric method (Reference method) (ISO 1211) EN ISO 3744, Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Engineering methods for an essentially free field over a reflecting plane (ISO 3744) EN ISO 4288, Geometrical product specifications (GPS) — Surface texture: Profile method — Rules and procedures for the assessment of surface texture (ISO 4288) EN ISO 4871, Acoustics — Declaration and verification of noise emission values of machinery and equipment (ISO 4871)
1) EN 60529:1991 is impacted by EN 60529:1991/A1:2000, Degrees of protection provided by enclosures (IP Code) (IEC 60529:1991/A1:2000). SIST EN 13732:2013
EN 13732:2013 (E) 8 EN ISO 11201:2010, Acoustics — Noise emitted by machinery and equipment — Determination of emission sound pressure levels at a work station and at other specified positions in an essentially free field over a reflecting plane with negligible environmental corrections (ISO 11201:2010) EN ISO 11202:2010, Acoustics — Noise emitted by machinery and equipment — Determination of emission sound pressure levels at a work station and at other specified positions applying approximate environmental corrections (ISO 11202:2010) EN ISO 12100:2010, Safety of machinery — General principles for design — Risk assessment and risk reduction (ISO 12100:2010) EN ISO 13732-1:2008, Ergonomics of the thermal environment — Methods for the assessment of human responses to contact with surfaces — Part 1: Hot surfaces (ISO 13732-1:2006) EN ISO 13849-1, Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design (ISO 13849-1) EN ISO 14122-2, Safety of machinery — Permanent means of access to machinery — Part 2: Working platforms and walkways (ISO 14122-2) EN ISO 14122-3, Safety of machinery — Permanent means of access to machinery — Part 3: Stairs, stepladders and guard-rails (ISO 14122-3) ISO 2852, Stainless steel clamp pipe couplings for the food industry ISO 2853, Stainless steel threaded couplings for the food industry 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN ISO 12100:2010, EN 1672-2:2005+A1:2009 and the following apply. 3.1 refrigerated bulk milk tank equipment for refrigeration, and bulk storage of refrigerated raw milk freshly milked Note 1 to entry: Referred to as “Tank” throughout this document. 3.2 open tank refrigerated bulk milk tank equipped with a lid which allows in open position manual washing of the inner vessel 3.3 closed tank refrigerated bulk milk tank equipped with automatic washing of the inner vessel Note 1 to entry: A manhole is only used for maintenance. 3.4 freshly milked milk less than 2 h after being milked 3.5 pre-cooled milk milk partially cooled before entering the tank SIST EN 13732:2013
EN 13732:2013 (E) 9 3.6 automatic control arrangement by which the equipment functions under normal operating conditions, without requiring action by the operator 3.7 atmospheric tank tank of which the inner vessel is designed to operate at atmospheric pressure 3.8 vacuum tank tank of which the inner vessel is designed to operate at a pressure below atmospheric pressure 3.9 agitator device to mix the milk to promote heat transfer and to ensure uniform distribution of butterfat 3.10 reference position position specified by the manufacturer for correct installation and operation of the tank 3.11 maximum volume Vm volume to which the inner vessel in its reference position and without agitation can be filled without overflowing (expressed in litres) 3.12 rated volume Vr volume of the maximum permissible filling of the tank under operating conditions as stated by the manufacturer (expressed in litres) 3.13 direct cooling system cooling system in which the evaporator of the refrigerating system is in direct thermal contact with the milk or the inner vessel 3.14 indirect cooling system cooling system in which the heat is transferred from the milk to the refrigerant through a cooling medium 3.15 ice bank tank tank with an indirect integrated cooling system in which the cooling medium is water and ice is built on the evaporator 3.16 milking quantity of milk (or test water) which is equivalent to 50 % of the theoretical maximum daily milk production 3.17 tank for two milkings tank intended to be emptied for milk collection each day and designed for cooling and storing its rated volume during 24 h SIST EN 13732:2013
EN 13732:2013 (E) 10 3.18 tank for four milkings tank intended to be emptied for milk collection every two days and designed for cooling and storing its rated volume during 48 h 3.19 tank for six milkings tank intended to be emptied for milk collection every three days and designed for cooling and storing its rated volume during 72 h 3.20 operating conditions state during which the tank is in use for the cooling and storage of milk in accordance with its design requirements and all accessories are functioning effectively 3.21 ambient atmosphere atmosphere surrounding the tank and in front of the air-cooled condenser of the refrigerating system 3.22 mean temperature calculated average of the different temperatures (in degrees Celsius) of a medium (air, test water, milk) measured at different measuring points, at the same time 3.23 ambient temperature mean temperature of the ambient atmosphere (in degrees Celsius) Note 1 to entry: See B.3. 3.24 performance temperature PT ambient temperature (in degrees Celsius) to be used when measuring the milk cooling time 3.25 safe operating temperature SOT highest limit of the range of ambient temperatures (in degrees Celsius) at which the equipment is required to function 3.26 initial temperature IT mean temperature (in degrees Celsius) of the milk to be cooled at the time of the commencement of the cooling test 3.27 storage temperature mean temperature (in degrees Celsius) to which the milk to be cooled is reduced for storage 3.28 cooling time time (in hours) required to cool a milking from initial temperature to + 4 °C SIST EN 13732:2013
EN 13732:2013 (E) 11 3.29 cooling cycle period between two successive milk collections Note 1 to entry: For tanks for two milkings, the cooling cycle is 24 h. For tanks for four milkings the cooling cycle is 48 h. For tanks for six milkings the cooling cycle is 72 h. 3.30 specific energy consumption energy consumption in watt-hours per litre of cooled milk, measured as the mean consumption of all components (excluding cleaning) during a cooling test under the test conditions appropriate to the performance class 3.31 milk bovine mammary secretion without either addition thereto or extraction therefrom, untreated and not standardized, complying with Code of principles concerning milk and milk products, international standards and standard methods of sampling and analysis for milk products of the Joint FAO/WHO Food Standards Programme 3.32 water water, suitable for human consumption, meeting the requirements specified in the EU Directive 80/778/EEC 3.33 test water TW water used for test purpose in place of milk Note 1 to entry: The cooling time for water is nearly the same as that for milk. 3.34 filling volume of the milk (or TW) in the tank 3.35 temperature of the milk (or TW) mean temperature of the milk (or TW) at a particular moment Note 1 to entry: See D.1.5. 3.36 compact and plug in tank tank where the condensing unit(s) is (are) mounted on the tank which leave(s) the manufacturer in a fully working condition
SIST EN 13732:2013
EN 13732:2013 (E) 12 4 List of significant h
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.