SIST EN ISO 22032:2026
(Main)Water quality - Determination of polybrominated diphenyl ethers (PBDE) in sediment, suspended particulate matter and biota - Method using gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) or with high resolution mass spectrometry (GC-HRMS) (ISO 22032:2026)
- Abstract
This document specifies a method for the determination of selected polybrominated diphenylethers (PBDE) (see Figure 1 and Table 1) in sediment, suspended particulate matter and biota using gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) or with high resolution mass spectrometry (GC-HRMS) in the electron impact (EI), negative ion chemical ionization (NCI) or atmospheric pressure ionization (APCI) mode.
The method is applicable to sediment and suspended particulate matter samples with limits of quantification of 0,2 µg/kg dry mass (dm) for brominated diphenylether (BDE) BDE-28 to BDE-183, of 2 µg/kg dry mass (dm) for BDE‑209.
The method is applicable as well with lower limits of quantification (LOQ), if specific clean-up methods, described in Clause 10, Table 3, method 1 and method 2 in combination with measurement methods GC-MS/MS or GC-HRMS after electron impact ionization (El) or negative ion chemical ionization (NCI) for BDE-209 are used. Depending on the analytical capability of the instrument, limits of quantification down to 0,003 µg/kg dm for BDE-28 to BDE-154 and 0,02 µg/kg dm for BDE-183 and 1 µg/kg dm for BDE-209 and lower are possible.
The method is applicable to biota samples with limits of quantification down to 0,000 2 µg/kg fresh mass (fm) (BDE-28 to BDE-154) and 0,03 μg/kg fresh mass (fm) (BDE-183), if specific clean-up methods, described in Table 4 in combination with measurement methods GC-MS/MS or GC-HRMS after electron impact ionization (El) are used.
Performance data are listed in Annex E.
- Status
- Published
- Public Enquiry End Date
- 24-Jun-2025
- Publication Date
- 18-Jun-2026
- Technical Committee
- KAV - Water quality
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 02-Jun-2026
- Due Date
- 07-Aug-2026
- Completion Date
- 19-Jun-2026
SIST EN ISO 22032:2026 is the Slovenian adoption of EN ISO 22032:2026, identical in content to ISO 22032:2026. It specifies a laboratory method for determining selected polybrominated diphenyl ethers (PBDE) in sediment, suspended particulate matter and biota using gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) or high resolution mass spectrometry (GC-HRMS).
The standard is written for analysts who need trace-level PBDE results with defined extraction, clean-up, identification, quantification and reporting steps. In practice, it tells a laboratory how to prepare the sample, separate interferences, check calibration, and decide whether a result can be reported.
What does SIST EN ISO 22032:2026 specify?
SIST EN ISO 22032:2026 specifies a GC-MS/MS or GC-HRMS method for selected PBDE congeners in sediment, suspended particulate matter and biota. The method uses electron impact (EI), negative ion chemical ionization (NCI) or atmospheric pressure ionization (APCI) depending on the instrument setup.
The document is organized into clauses 1 to 16 and five annexes. The clauses cover scope, references, principle, interferences, reagents, apparatus, sampling and pretreatment, extraction, clean-up, measurement, calibration, identification, quantification, expression of results and the test report.
| Annex | What it covers |
|---|---|
| Annex A | Programs for pressurized liquid extraction and alternative extraction procedures |
| Annex B | Clean-up methods for sediment, suspended particulate matter and biota |
| Annex C | Typical GC-MS conditions and m/z values for identification and quantification |
| Annex D | Examples of linearity check and calibration working solutions |
| Annex E | Performance data from validation work |
What are the key requirements of SIST EN ISO 22032:2026?
SIST EN ISO 22032:2026 is built around extraction, clean-up, instrumental measurement and internal-standard calibration. The practical point is that a laboratory must control contamination, recover the analytes from the matrix, and show that the instrument and calibration remain valid.
Sample handling and extraction
Clause 8 requires sampling, storage and pretreatment that protect the analytes and the sample condition. Samples are kept in the dark and cooled, then homogenized and freeze-dried or mixed with sodium sulfate, and dried material is protected from moisture.
Clause 9 then separates the sample types. Sediment and suspended particulate matter are extracted with pressurized liquid extraction (PLE) or Soxhlet, while biota can be extracted by PLE, Soxhlet or Twisselmann extraction, and biota also has a cold extraction alternative. This matters because the matrix drives the extraction choice and the method gives the lab defined options for different sample types.
Clean-up and matrix control
Clause 10 requires the analyst to choose one of several clean-up methods according to the matrix and PBDE load. For sediment and suspended particulate matter, the standard gives five clean-up routes, and for biota it gives three routes, including column chromatography, gel permeation chromatography (GPC), and automated clean-up.
The document also allows options that avoid dichloromethane and toluene in some clean-up steps. In practice, this gives laboratories flexibility to match local safety practices or instrumentation, while still using a validated clean-up sequence that removes sulfur, lipids and other co-extractives.
Instrumental measurement
Clause 11 requires GC-MS system conditions to be optimized and checked against a calibration standard before analysis. The method uses capillary gas chromatography and mass spectrometric detection, and Annex C gives example conditions and example ion transitions.
For BDE-209, the standard gives special attention to thermal stability, because high injector and separation temperatures can degrade it. That means the laboratory has to limit heat exposure during injection and separation if it wants reliable decabromodiphenyl ether results.
Calibration and quality control
Clause 12 requires calibration and quantification in line with ISO 8466-1 and ISO/TS 13530, and EN 16190 is also named for soil, treated biowaste and sludge. The method uses internal-standard calibration with matrix-free calibration solutions and C-labelled internal standards, with at least one C-labelled internal standard per degree of bromination.
The standard also requires a linearity check using multiple concentration levels, with the lowest calibration point at or below the LOQ of the solid sample. In practice, this tells the lab how to build the calibration range around the reporting limit rather than around a convenient instrument range.
Identification, quantification and reporting
Clause 13 identifies an analyte by retention time and by the ion ratio compared with the calibration standard. Clause 14 quantifies using internal standards and checks internal-standard recovery, and a sample cannot be quantified if the recovery rate is below 25 %.
Clause 15 requires results in micrograms per kilogram, with the mass basis stated as dry mass (dm) or fresh mass (fm), and the results are given to two significant figures. Clause 16 lists what the test report has to include, including the method reference, sample identity, deviations, circumstances affecting the result, sample-preparation date and test date. For the user, this means the report must be traceable enough to support audits, data review and regulatory use.
Practical scope limits
The scope states that the method applies to sediment and suspended particulate matter at 0,2 µg/kg dm for BDE-28 to BDE-183 and 2 µg/kg dm for BDE-209. With specific clean-up and detection choices, lower LOQs are possible, and the biota application reaches much lower fresh-mass levels for selected congeners. That matters if the laboratory is working on environmental background levels or needs low detection limits for monitoring.
Who uses SIST EN ISO 22032:2026?
SIST EN ISO 22032:2026 is used by environmental and water-analysis laboratories that measure PBDE in sediment, suspended particulate matter and biota. It is also relevant to quality managers, technical reviewers and buyers who need a defined method for trace organic contaminants in environmental samples.
The method fits routine monitoring, contract testing, and validation work where sample preparation, mass spectrometric identification and recovery checks have to be documented. It is especially relevant where results need to be comparable across laboratories.
What changed in SIST EN ISO 22032:2026 from the previous edition?
SIST EN ISO 22032:2026 supersedes SIST EN ISO 22032:2009 and EN ISO 22032:2009. The second edition cancels and replaces ISO 22032:2006 and is technically revised.
The stated main changes are:
- the scope is expanded to include biota
- GC-MS/MS is included as a detection method
- a clean-up set with manual and automated methods for sediment, suspended particulate matter and biota is included
Which standards are used with SIST EN ISO 22032:2026?
SIST EN ISO 22032:2026 names three normative references:
- ISO 8466-1:2021 - used for linear calibration function and evaluation of analytical methods
- ISO/TS 13530 - used for analytical quality control for chemical and physicochemical water analysis
- EN 16190 - used where calibration and quantification in soil, treated biowaste and sludge are carried out
The bibliography also points to sampling guidance and related analytical and validation standards that support the method, especially for sample collection, preservation and performance evaluation.
What does the SIST EN ISO 22032:2026 document contain?
SIST EN ISO 22032:2026 contains the general structure of PBDE congeners in Figure 1, the target congeners in Table 1, C-labelled internal standards in Table 2, and method choices for sediment, suspended particulate matter and biota clean-up in Tables 3 and 4. Annex A gives extraction programs, Annex B gives detailed clean-up procedures, Annex C gives example GC-MS conditions and example ions and transitions, Annex D gives calibration working solutions, and Annex E presents performance data from an interlaboratory validation.
It also gives practical details on reagents, solvents, apparatus, sampling and pretreatment, calibration checking, identification criteria and test-report content. For a laboratory, that means the document is not only a scope statement but a complete analytical workflow from sample receipt to reported result.
Relations
- Effective Date
- 01-Jul-2026
- Effective Date
- 21-Oct-2026
- Effective Date
- 21-Oct-2026
- Effective Date
- 21-Oct-2026
- Effective Date
- 27-May-2026
- Effective Date
- 27-May-2026
- Referred By
SIST EN ISO 5211:2023 - Industrial valves - Part-turn actuator attachments (ISO 5211:2023) - Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard

ECOCERT
Organic and sustainability certification.
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Eurofins Food Testing Global
Global leader in food, environment, and pharmaceutical product testing.
Sponsored listings
Frequently Asked Questions
SIST EN ISO 22032:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Water quality - Determination of polybrominated diphenyl ethers (PBDE) in sediment, suspended particulate matter and biota - Method using gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) or with high resolution mass spectrometry (GC-HRMS) (ISO 22032:2026)". This standard covers: This document specifies a method for the determination of selected polybrominated diphenylethers (PBDE) (see Figure 1 and Table 1) in sediment, suspended particulate matter and biota using gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) or with high resolution mass spectrometry (GC-HRMS) in the electron impact (EI), negative ion chemical ionization (NCI) or atmospheric pressure ionization (APCI) mode. The method is applicable to sediment and suspended particulate matter samples with limits of quantification of 0,2 µg/kg dry mass (dm) for brominated diphenylether (BDE) BDE-28 to BDE-183, of 2 µg/kg dry mass (dm) for BDE‑209. The method is applicable as well with lower limits of quantification (LOQ), if specific clean-up methods, described in Clause 10, Table 3, method 1 and method 2 in combination with measurement methods GC-MS/MS or GC-HRMS after electron impact ionization (El) or negative ion chemical ionization (NCI) for BDE-209 are used. Depending on the analytical capability of the instrument, limits of quantification down to 0,003 µg/kg dm for BDE-28 to BDE-154 and 0,02 µg/kg dm for BDE-183 and 1 µg/kg dm for BDE-209 and lower are possible. The method is applicable to biota samples with limits of quantification down to 0,000 2 µg/kg fresh mass (fm) (BDE-28 to BDE-154) and 0,03 μg/kg fresh mass (fm) (BDE-183), if specific clean-up methods, described in Table 4 in combination with measurement methods GC-MS/MS or GC-HRMS after electron impact ionization (El) are used. Performance data are listed in Annex E.
This document specifies a method for the determination of selected polybrominated diphenylethers (PBDE) (see Figure 1 and Table 1) in sediment, suspended particulate matter and biota using gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) or with high resolution mass spectrometry (GC-HRMS) in the electron impact (EI), negative ion chemical ionization (NCI) or atmospheric pressure ionization (APCI) mode. The method is applicable to sediment and suspended particulate matter samples with limits of quantification of 0,2 µg/kg dry mass (dm) for brominated diphenylether (BDE) BDE-28 to BDE-183, of 2 µg/kg dry mass (dm) for BDE‑209. The method is applicable as well with lower limits of quantification (LOQ), if specific clean-up methods, described in Clause 10, Table 3, method 1 and method 2 in combination with measurement methods GC-MS/MS or GC-HRMS after electron impact ionization (El) or negative ion chemical ionization (NCI) for BDE-209 are used. Depending on the analytical capability of the instrument, limits of quantification down to 0,003 µg/kg dm for BDE-28 to BDE-154 and 0,02 µg/kg dm for BDE-183 and 1 µg/kg dm for BDE-209 and lower are possible. The method is applicable to biota samples with limits of quantification down to 0,000 2 µg/kg fresh mass (fm) (BDE-28 to BDE-154) and 0,03 μg/kg fresh mass (fm) (BDE-183), if specific clean-up methods, described in Table 4 in combination with measurement methods GC-MS/MS or GC-HRMS after electron impact ionization (El) are used. Performance data are listed in Annex E.
SIST EN ISO 22032:2026 is classified under the following ICS (International Classification for Standards) categories: 13.060.50 - Examination of water for chemical substances; 71.040.50 - Physicochemical methods of analysis. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN ISO 22032:2026 has the following relationships with other standards: It is inter standard links to SIST EN ISO 22032:2009, SIST-TS ISO/TS 13530:2013, SIST ISO 8466-1:2026, SIST EN 16190:2019, SIST EN 17331:2024, SIST-TS CEN/TS 17331:2019, SIST EN ISO 5211:2023. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN ISO 22032:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Principle
- 5 Interferences
- 6 Reagents and standards
- 7 Apparatus
- 7.10 Automatic sample processing system, e.g. DexTech/DexTech Plus from LC-Tech, MiuraTM GO-2HT
- 7.14 Gel permeation chromatography (GPC) clean-up system (with modular design), pump, sampling
- 8 Sampling and sample pretreatment
- 9 Procedure
- 9.1 Extraction of sediment or particulate matter samples by pressurized liquid extraction
- 9.2 Extraction of biota samples
- 10 Clean-up of sample extracts
- 11 Measurement and integration of the chromatogram
- 12 Calibration
- 12.1 General
- 12.2 Estimation of the linear range
- 12.4 Injection standard
- 13 Identification
- 14 Quantification
- 14.1 Quantification using internal standards, including quality checks of the recovery of the
- 14.2 Testing the validity of calibration
- 15 Expression of results
- 16 Test report
- Annex A
- 2 Twisselmann extractor
- Annex B
- Annex C
- Annex D
- Annex E
- Bibliography
Introduction
This document enables the analysis of polybrominated diphenyl ethers (PBDE) related to 91/271/EEC - the Urban Waste Water Treatment Directive, the European Union directive concerning the collection, treatment and discharge of urban waste water and the treatment and discharge of waste water from certain industrial sectors.
SIST EN ISO 22032:2026
SIST EN ISO 22032:2026 International Standard ISO 22032:2026(en) Water quality — Determination of polybrominated diphenyl ethers (PBDE) in sediment, suspended particulate matter and biota — Method using gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) or with high resolution mass spectrometry (GC-HRMS) WARNING — Persons using this document should be familiar with normal laboratory practice. This document does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices. IMPORTANT — It is absolutely essential that tests conducted in accordance with this document be carried out by suitably qualified staff.
1 Scope
This document specifies a method for the determination of selected polybrominated diphenylethers (PBDE) (see Figure 1 and Table 1) in sediment, suspended particulate matter and biota using gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) or with high resolution mass spectrometry (GC- HRMS) in the electron impact (EI), negative ion chemical ionization (NCI) or atmospheric pressure ionization (APCI) mode.
The method is applicable to sediment and suspended particulate matter samples with limits of quantification of 0,2 µg/kg dry mass (dm) for brominated diphenylether (BDE) BDE-28 to BDE-183, of 2 µg/kg dry mass (dm) for BDE-209.
The method is applicable as well with lower limits of quantification (LOQ), if specific clean-up methods, described in Clause 10, Table 3, method 1 and method 2 in combination with measurement methods GC- MS/MS or GC-HRMS after electron impact ionization (El) or negative ion chemical ionization (NCI) for BDE- 209 are used. Depending on the analytical capability of the instrument, limits of quantification down to 0,003 µg/kg dm for BDE-28 to BDE-154 and 0,02 µg/kg dm for BDE-183 and 1 µg/kg dm for BDE-209 and lower are possible.
The method is applicable to biota samples with limits of quantification down to 0,000 2 µg/kg fresh mass (fm) (BDE-28 to BDE-154) and 0,03 μg/kg fresh mass (fm) (BDE-183), if specific clean-up methods, described in Table 4 in combination with measurement methods GC-MS/MS or GC-HRMS after electron impact ionization (El) are used.
Performance data are listed in Annex E.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 8466-1:2021, Water quality — Calibration and evaluation of analytical methods — Part 1: Linear calibration function ISO/TS 13530, Water quality — Guidance on analytical quality control for chemical and physicochemical water analysis
SIST EN ISO 22032:2026 ISO 22032:2026(en) EN 16190, Soil, treated biowaste and sludge — Determination of dioxins and furans and dioxin-like polychlorinated biphenyls by gas chromatography with high resolution mass selective detection (HR GC-MS)
3 Terms and definitions
No terms and definitions are listed in this document.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
4 Principle
Brominated diphenyl ethers are extracted from dried sample material (sediment, suspended particulate matter, biota) using organic solvents.
Figure 1 — General structure of polybrominated diphenyl ethers Table 1 — PBDE congeners determined by this method a b No. Congener Formula Abbreviation CAS-RN Molar mass g/mol 1 2,4,4'-Tribromodiphenyl ether C H Br O BDE-28 41318-75-6 406,9 12 7 3 2 2,2',4,4'-Tetrabromodiphenyl ether C H Br O BDE-47 5436-43-1 485,8 12 6 4 3 2,2',4,4',5-Pentabromodiphenyl ether C H Br O BDE-99 60348-60-9 564,7 12 5 5 4 2,2',4,4',6-Pentabromodiphenyl ether C H Br O BDE-100 189084-64-8 564,7 12 5 5 5 2,2',4,4',5,5'-Hexabromodiphenyl ether C H Br O BDE-153 68631-49-2 643,6 12 4 6 6 2,2',4,4',5,6'-Hexabromodiphenyl ether C H Br O BDE-154 207122-15-4 643,6 12 4 6 7 2,2',3,4,4',5',6-Heptabromodiphenyl ether C H Br O BDE-183 207122-16-5 722,5 12 3 7 8 Decabromodiphenyl ether C Br O BDE-209 1163-19-5 959,2 12 10 a Numbering analogous to IUPAC nomenclature for Polychlorinated Biphenylethers PCB. b Chemical Abstracts Service (CAS) Registry Number® is a trademark of the American Chemical Society (ACS). This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of the product named. Equivalent products may be used if they can be shown to lead to the same results. Clean-up of the extract is carried out by various methods as specified in this document. Depending on the matrix and the concentration of PBDE in the samples five different clean-up methods for sediment samples and three methods for biota samples can be selected, e.g. column chromatography or gel permeation chromatography. Options for avoiding dichloromethane and toluene in the sample clean-up are available. After clean-up and concentration, separation of the brominated diphenyl ethers is accomplished by capillary gas chromatography. For detection, different types of GC-MS equipment can be used, applying either mass spectrometry in multiple reaction mode, or high resolution mass spectrometry with different ionisation techniques as electron impact (EI), negative ion chemical ionization (NCI) or atmospheric pressure chemical ionisation (APCI).
SIST EN ISO 22032:2026 ISO 22032:2026(en) For the determination of the analyte concentration in the sample, an internal standard calibration is used.
5 Interferences
Non-specific matrix interferences, as well as interferences from other environmental contaminants are dealt with using the given clean-up procedures.
Sources of contamination of the samples can be the following: brominated diphenyl ethers used as flameretardants or for other purposes in organic polymers, used in vial covers, Pasteur pipette fillers, recycled paper and are possibly transported also via air dust. Therefore, any contact of samples, reagents or any material used with these organic polymers shall be avoided.
PCB-180 can interfere with BDE-47 if a short column is used. The application of MS/MS detection as well as avoiding m/z 323,87 in the detection by GC-HRMS allows for separation the compounds via mass spectrometry.
Interferences with other chlorinated substances can occur, if chromatographic separation is not sufficient as described in Reference [14]:
- BDE-47 at m/z 323,878 5 with Heptachlorobiphenyl at m/z 323,864 7 such as PCB-180;
- BDE-100 and BDE-99 at m/z 403,787 0 with Octachloronaphthalene at m/z 403,745 0;
- BDE-100 and BDE-99 at m/z 405,784 9 with Heptachlorodibenzofurans at m/z 405,784 7. MS/MS detection at optional m/z values (see Table C.1) can solve the problem. Therefore, careful evaluation of instrumentation, masses and mass transitions used in MS shall be done. Further interferences from BDE-congeners not listed in this document, as well as by other brominated compounds can be found in Reference [15]. Coelutions can occur especially when using short columns and short oven programs. Such potential interferences depending on the analytical column are:
- BDE-16, BDE-33 interfering with BDE-28;
- BDE-184, BDE-182 and BDE-175 interfering with BDE-183.
These and further interferences should be overcome by a sufficient chromatographic separation.
6 Reagents and standards
Use only reagents and materials with negligibly low concentrations of brominated diphenyl ethers, verify this in every analysis series by blank determinations over the total procedure. The blank over the total procedure shall be less than the reported limit of detection (see the definition of the limit of detection in ISO/TS 13530). If necessary, traces of PBDE in solid materials can be reduced by heating at 400 °C. 6.1 Solvents for extraction, preparation of stock solutions and clean-up. 6.1.1 n-Heptane, C H .
7 16 6.1.2 Toluene, C H .
7 8 6.1.3 Acetone (2-propanone), C H O.
3 6 6.1.4 Dichloromethane, CH Cl .
2 2 6.1.5 Cyclohexane, C H .
6 12 6.1.6 Dodecane, C H for automatized clean-up or as a keeper.
12 26,
SIST EN ISO 22032:2026 ISO 22032:2026(en) 6.1.7 n-Hexane, C H .
6 14 6.1.8 Ethanol, C H O.
2 6 6.1.9 Ethyl acetate, C H O .
4 8 2 6.2 Reference stock solutions.
See Table 1. Solutions of reference substances are commercially available. Store the prepared solutions in a refrigerator at (5 ± 3) °C, alternatively according to the manufacturer. 6.3 Internal standard stock solutions.
Solutions of C-labelled reference substances for use as internal standards are commercially available. Store the prepared solutions in a refrigerator at (5 ± 3) °C, alternatively according to the manufacturer. See Table 2.
Table 2 — List of C-labelled internal standards No Name Formula Abbreviation Molar mass g/mol 13 13 13 1 2,4,4'-Tribromo[ C ]diphenyl ether C H Br O C-BDE-28 418,8 12 12 7 3 13 13 13 2 2,2',4,4'-Tetrabromo[ C ]diphenyl ether C H Br O C-BDE-47 497,7 12 12 6 4 13 13 13 3 2,2',4,4',5-Pentabromo[ C ]diphenyl ether C H Br O C-BDE-99 576,6 12 12 5 5 13 13 13 4 2,2',4,4',6-Pentabromo[ C ]diphenyl ether C H Br O C-BDE-100 576,6 12 12 5 5 13 13 13 5 2,2',4,4',5,5'-Hexabromo[ C ]diphenyl ether C H Br O C-BDE-153 655,5 12 12 4 6 13 13 13 6 2,2',4,4',5,6'-Hexabromo[ C ]diphenyl ether C H Br O C-BDE-154 655,5 12 12 4 6 13 13 13 7 2,2',3,4,4',5',6-Heptabromo[ C ]diphenyl ether C H Br O C-BDE-183 734,4 12 12 3 7 13 13 13 8 Decabromo[ C ]diphenyl ether C Br O C-BDE-209 971,1 12 12 10 6.4 Internal standard working solutions for calibration and addition to the samples, see Annex D. 6.5 Sodium sulfate, Na SO , anhydrous powdered baked in oven (7.5) for 4 hours at 400 °C. 2 4 6.6 Water, free of blanks and potential interferences.
6.7 Extraction filters, e.g. cellulose for PLE-extractor.
6.8 Soxhlet thimbles, (e.g. 27 mm × 100 mm) (pre-cleaned).
6.9 Sand (blank free), e.g. Ottawa sand or sea sand for blank analysis over the total procedure and as a filling of the extraction cells; alternative: glass granulate. 6.10 Basic alumina, (Al O ), activity Super I, particle size 0,063 mm to 0,2 mm, pH 10 (100 g/l, H O, 20 °C) 2 3 2 3 1) (in slurry) density 3,94 g/cm , e.g. MP Alumina B – Super I for Dioxin Analysis 1344-28-1 (mpbio.com), avoid long storage and contact with air humidity.
1) This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of the product named. Equivalent products may be used if they can be shown to lead to the same results.
SIST EN ISO 22032:2026 ISO 22032:2026(en) 6.11 Basic alumina, (Al O ), activity I, particle size 0,063 mm to 0,2 mm, pH 8,5 to pH 10,5 (100 g/l, H O, 2 3 2
20 °C) (in slurry) density 4 g/cm , (20 °C), pore size 9 nm, avoid long storage and contact with air humidity. 6.12 Silica 60, (70 mesh to 230 mesh).
6.13 Silver nitrate, (AgNO ).
6.14 Sulfuric acid, H SO , 95 % to 97 %.
2 4 6.15 Hydrochloric acid, HCl, 2 mol/l.
6.16 Material for fixing the adsorbent materials in the clean-up columns, e.g. quartz wool or glass wool, silanised glass wool.
6.17 Copper powder, grain size < 63 µm.
6.18 Silica-sulfuric acid.
Add 44 g sulfuric acid (6.14) dropwise to 56 g silica (6.12). Subsequently shake for 30 min. Store tightly closed in brown glass bottles. The mixture is stable for at least 1 month. 6.19 Silica-silver nitrate.
Dissolve 10 g AgNO (6.13) in 40 ml water (6.6), add solution stepwise to 90 g silica (6.12) and stir, activate
at 125 °C for 5 hours. Store tightly closed in brown glass bottles. The mixture is stable at least for 1 month. 6.20 Operating gases, for GC-MS, of high purity and in accordance with manufacturer’s specifications. 6.21 Nitrogen, N , for concentrating of extracts.
6.22 Linearity check and calibration working solutions.
Considering the working range and the sample amount, prepare calibration solutions using syringes (7.17) with the lowest point corresponding to the LOQ of the method (example given in Annex D). The concentration of the internal standard should be between the medium and the top level of the calibration range (example given in Annex D).
6.23 Injection standards.
The following C-labelled injection standards are commercially available and have proven to be practicable:
13 13 - 3,3',4,4'-Tetrabromo( C )diphenyl ether ( C-BDE-77);
13 13 - 3,3',4,5'-Tetrabromo( C )diphenyl ether ( C-BDE-79);
13 13 - 2,3’,4,4’,5-Pentabromo( C )diphenyl ether ( C-BDE-118);
13 13 - 2,2',3,4,4',5-Hexabromo( C )diphenyl ether ( C-BDE-137);
13 13 - 2,2',3,4,4',5’-Hexabromo( C )diphenyl ether ( C-BDE-138);
13 13 - 2,2',3,4,4',6-Hexabromo( C )diphenyl ether ( C-BDE-139);
13 13 - 2,2',3,4,4',5,5'-Heptabromo( C )diphenyl ether ( C-BDE-180);
13 13 - 2,3,3',4,4',5,6-Heptabromo( C )diphenyl ether ( C-BDE-190);
13 13 - 2,2',3,4,4',5,5',6-Octabromo( C )diphenyl ether ( C-BDE-203);
SIST EN ISO 22032:2026 ISO 22032:2026(en) 13 13 - 2,3,3',4,4',5,5',6-Octabromo( C )diphenyl ether ( C-BDE-205);
13 13 - 2,2',3,3',4,4',5,5',6-Nonabromo( C )diphenyl ether ( C-BDE-206).
Use commercially available solutions (6.2, 6.3) (e.g. in nonane, toluene or iso-octane) or prepare stock solutions, e.g. by dissolving 10 mg of each of the reference substances in n-heptane (6.1.1) in an amber, 10-ml volumetric flask (7.15) and bring to volume (concentration: 1 mg/ml). Examples for calibration working solutions are given in Annex D. For the linearity check use at least six concentration levels.
The solutions may be stored in a refrigerator at (5 ± 3) °C in the dark for at least 1 year. Check the concentration of the calibration solutions against an independently prepared standard prior to use.
7 Apparatus
Clean all glassware at least by rinsing with acetone (2-propanone) (6.1.3). 7.1 Wide-necked bottle, 1 000 ml up to 5 000 ml capacity, for wet sediment, particulate matter or biota. 7.2 Freeze drying apparatus.
7.3 Deep freezer.
7.4 Mortar and pestle, or a grinding mill.
7.5 Drying ovens, capable of maintaining temperatures in the ranges of 100 °C to 400 °C for baking of clean-up materials, for baking of glassware and for dry residue determination of samples. 7.6 Sieve shaker with appropriate sieve meshes (aperture size), 2 mm. 7.7 Desiccator.
7.8 Pressurized liquid extractor (PLE) and appropriate filter materials suited for the device, alternatively Soxhlet extraction apparatus, consisting of round bottom flasks (e.g. 250 ml), Soxhlet extractors and Soxhlet thimbles (e.g. 27 mm × 100 mm) see 6.8, vertical condensers (e.g. 300 mm) and heating apparatus or Twisselmann extraction system.
7.9 Evaporation device, e.g. rotary evaporator or concentration device with suitable gases 6.21.
7.10 Automatic sample processing system, e.g. DexTech/DexTech Plus from LC-Tech, MiuraTM GO-2HT
2) (Miura Co. Ltd).
7.11 Small glass columns for chromatographic clean-up, 1 cm inner diameter, approximately 12 mm × 140 mm with a stopcock.
7.12 Big glass columns for chromatographic clean-up, > 2 cm inner diameter, approximately 25 mm × 150 mm with a stopcock.
7.13 Ready to use columns for automatized clean-up from, e.g. LC-Tech or Miura-system: see Clause B.7. 2) DexTech/DexTech Plus from LC-Tech, MiuraTM GO-2HT (Miura Co. Ltd) are automatic sample processing systems. This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of the automatic sample processing systems. Equivalent systems may be used if they can be shown to lead to the same results.
SIST EN ISO 22032:2026 ISO 22032:2026(en)
7.14 Gel permeation chromatography (GPC) clean-up system (with modular design), pump, sampling
injector, sample rack; fraction collector, column: e.g. Ashahipak GF 310 HQ 7,5 mm × 300 mm, 5 µm particle size.
7.15 Volumetric flasks, 1 ml, 2 ml, 10 ml and 25 ml, preferable amber glass. 7.16 Pasteur pipettes, e.g. 2 ml.
7.17 Syringes, 2 µl, 5 µl, 10 µl and 50 µl, volume precision ±2 %. 7.18 GC-sample vials, e.g. 2 ml, amber glass with a micro insert and a fluoropolymer-lined screw-cap is most suitable.
7.19 Gas chromatograph, with operating gases 6.20 with a splitless injection port or a temperature programmable injection port, coupled to a tandem mass spectrometer (GC-MS/MS) or GC-HRMS with electron impact or chemical ionization and appropriate reactant gas (e.g. CH ) or atmospheric pressure
ionization.
7.20 Analytical column, fused silica column with non-polar low bleed separating phase (see Annex C for examples); inner diameter < 0,25 mm, length 15 m, film thickness of 0,1 µm is recommended.
8 Sampling and sample pretreatment
Take samples, see e.g. ISO 5667-12, ISO 5667-13 or ISO 5667-17, in a bottle (7.1). Store and transport in the dark at approximately 4 °C (see ISO 5667-15). Pre-treat the samples immediately in the laboratory by homogenizing and freeze-drying (7.2), alternatively mix them with sodium sulfate (6.5). If an immediate pre-treating is not possible, samples can be frozen (7.3) and stored in a freezer at a temperature below −15 °C (see ISO 5667-15). Deagglomerize the dried samples using apparatus e.g. (7.4) and sieve it using device (7.6) according to the analytical task.
Take and pretreat biota samples, see e.g. EN 14011, EN 14757, EN 16150, EN 17218, ISO 10870 or EN 13946, immediately either before or after homogenizing by freezing. Freeze dry to remove water and to enhance the surface for later extraction.
Store the dried samples protected against air humidity, e.g. in a desiccator (7.7).
9 Procedure
9.1 Extraction of sediment or particulate matter samples by pressurized liquid extraction
(PLE) or Soxhlet Place the filter (6.7) or thimble (6.8) and, if applicable, the sand (6.9) in the extractor according to the instructions for the extractor (PLE) (7.8) or Soxhlet extractor (7.8). Transfer a suitable amount, e.g. 5 g, of the pre-treated, dry sample into the prepared extractor cell. Add a suitable amount of the internal standard working solution (6.4) prepared from the internal standard stock solutions (6.3) to the sample and add 2 ml of the extraction solvent (6.1) to avoid losses of the internal standard. Add sand (6.9) on the top. The extraction programs and solvents for PLE or Soxhlet given in Clauses A.1 and A.3 shall be applied. Protect samples and extracts carefully from sunlight to avoid photodegradation of the PBDE, especially BDE-209.
NOTE 1 Other extraction techniques can be used after performing comparability exercise with PLE and the given program or Soxhlet extraction. Extraction of BDE-209 requires specific attention and, sometimes, longer extraction times than for other PBDE congeners.
NOTE 2 Other extraction solvents, can be used after performing comparability exercise.
SIST EN ISO 22032:2026 ISO 22032:2026(en) Concentrate the extract from the extractor gently (at a temperature of 40 °C) to 1 ml ± 0,5 ml using a suitable evaporation device (7.9).
...



