SIGNIFICANCE AND USE
5.1 The absorbance of liquids and the absorptivity of liquid and solids at specified wavelengths in the ultraviolet are useful in characterizing petroleum products.
SCOPE
1.1 This test method covers the measurement of the ultraviolet absorption of a variety of petroleum products. It covers the absorbance of liquids or the absorptivity of liquids and solids, or both, at wavelengths in the region from 220 nm to 400 nm of the spectrum.  
1.2 The use of this test method implies that the conditions of measurement—wavelength, solvent (if any), sample path length, and sample concentration—are specified by reference to one of the examples of the application of this test method in the annexes or by a statement of other conditions of measurement.  
1.3 Examples of the application of this test method are the absorptivity of refined petroleum wax, and the absorptivity of USP petrolatum.  
1.4 The values stated in SI units are to be regarded as the standard. The values stated in Fahrenheit, feet, and inches, indicated in parentheses, are for information only.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 7.3.1, 7.3.3, and 13.4.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    7 pages
    English language
  • Standard
    7 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method for naphthalene hydrocarbons is one of a group of tests used to assess the combustion characteristics of aviation turbine fuels of the kerosene boiling range. The naphthalene hydrocarbon content is determined because naphthalenes, when burned, tend to have a relatively larger contribution to a sooty flame, smoke, and thermal radiation than single ring aromatics.
SCOPE
1.1 This test method covers the determination, by ultraviolet spectrophotometry, of the total concentration of naphthalene, acenaphthene, and alkylated derivatives of these hydrocarbons in jet fuels. This test method is designed to analyze fuels containing not more than 5 % of such components and having end points below 315 °C (600 °F). The range of concentrations used in the interlaboratory test programs which established the precision statements for this test method was 0.08 % to 5.6 % by volume. This test method determines the maximum amount of naphthalenes that could be present.  
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 8.1 and 8.2.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method provides accurate biobased/biogenic carbon content results to materials whose carbon source was directly in equilibrium with CO2 in the atmosphere at the time of cessation of respiration or metabolism, such as the harvesting of a crop or grass living in a field. Special considerations are needed to apply the testing method to materials originating from within artificial environments with non-natural levels of 14C or if the biofeed was grown over the course of several years such as trees and contains “bomb-carbon.” Application of these test methods to materials derived from CO2 uptake within artificial environments is beyond the present scope of this standard.  
5.2 This method uses LSC techniques to quantify the biobased content of a liquid hydrocarbon fuels using sample carbon that has been unmodified. It is designed to be able to incorporate into a refinery laboratory to support biofeed and petroleum coprocessing or blending operations to determine the biocarbon content of the intermediate or finished products. The test results can then be used for optimizing internal parameters or reporting to regulatory agencies.  
5.3 The use of this method requires that a pure petroleum-based sample can be generated that has a similar matrix to each product or stream to be analyzed. For example, gasoline and diesel have very different matrices and will likely require the use of different background measurements for each. Refer to 10.2 for how to determine if the same background sample can be used for more than one product/stream.
SCOPE
1.1 This test method covers quantitatively determining biocarbon content of liquid hydrocarbon fuels with a focus on those produced in a typical petroleum refinery using liquid scintillation counting (LSC). The method is designed to generate analogous results as Test Method D6866 Method C, for low quench samples, without the need of benzene synthesis. The purpose is to be able to use the produced data to report biocarbon content of refinery products to regulatory agencies and monitor refinery operation. The method does not address regulatory reporting or fuel performance.  
1.2 The method is needed to support refinery operations when bio-feeds are co-processed with petroleum within a reactor with a focus on samples with 100 % biocarbon or less (not for 14C labeled species). It allows refineries to report the biocarbon content of refinery products to regulatory agencies such as the Environmental Protection Agency (EPA) or California Air Resources Board (CARB) to comply with regulatory statutes such as The Renewable Fuel Standard (RFS) or Low Carbon Fuel Standard (LCFS).  
1.3 This test method is applicable to any liquid fuel product, petroleum based (pure hydrocarbon), biobased (such as renewable diesel or those that can contain oxygenates such as ethanol), or blends, that contain 1 % to 100 % by mass biocarbon where an instrument background can be experimentally determined using a sample of similar matrix that contains no measurable carbon-14.  
1.4 This test method makes no attempt to teach the basic principles of the instrumentation used although minimum requirements for instrument selection are referenced in Refs (1-11).2 However, the preparation of samples for the above test methods is described. No details of instrument operation are included here. These are best obtained from the manufacturer of the specific instrument in use.  
1.5 Pre-Requisite Requirements For Method Execution—This test method uses artificial carbon-14 (14C) within the method. Great care shall be taken to prevent laboratory contamination of the elevated 14C. Once in the laboratory, artificial 14C can contaminate a variety of laboratory surfaces that can lead to artificially high sample biocarbon measurements. If vigorous cleaning attempts to remove the artificial 14C from a laboratory are unsuccessful, instrumentation and sample preparation may have to be moved to a ne...

  • Standard
    15 pages
    English language

SIGNIFICANCE AND USE
5.1 Biodiesel is a blendstock commodity primarily used as a value-added blending component with diesel fuel.  
5.2 This test method is applicable for quality control in the production and distribution of diesel fuel and biodiesel blends containing FAME.
SCOPE
1.1 This test method covers the determination of the content of fatty acid methyl esters (FAME) biodiesel in diesel fuel oils. It is applicable to concentrations from 1.00 % to 20 % by volume (see Note 1). This procedure is applicable only to FAME. Biodiesel in the form of fatty acid ethyl esters (FAEE) will cause a negative bias.
Note 1: Using the proper ATR sample accessory, the range may be expanded from 1 % to 100 % by volume, however precision data is not available above 20 % by volume.  
1.2 The values stated in SI units of measurement are to be regarded as the standard. The values given in parentheses are for information only.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    10 pages
    English language

SIGNIFICANCE AND USE
5.1 Benzene is a compound that endangers health, and the concentration is limited by environmental protection agencies to produce a less toxic gasoline.  
5.2 This test method is fast, simple to run, and inexpensive.  
5.3 This test method is applicable for quality control in the production and distribution of spark-ignition engine fuels.
SCOPE
1.1 This test method covers the determination of the percentage of benzene in spark-ignition engine fuels. It is applicable to concentrations from 0.1 % to 5 % by volume.  
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    10 pages
    English language

SIGNIFICANCE AND USE
5.1 Alcohols and ethers are added to gasoline to produce a reformulated lower emissions gasoline. Alcohols and ethers may also be added to gasoline to increase the octane number. Type and concentration of various oxygenates are specified and regulated to ensure acceptable commercial gasoline quality. Driveability, vapor pressure, phase separation, and evaporative emissions are some of the concerns associated with oxygenated fuels.  
5.2 This test method is faster, simpler, less expensive and more portable than current methods.  
5.3 This test method may be applicable for quality control in the production of gasoline.  
5.4 This test method is not suitable for testing for compliance with federal regulations.3  
5.5 False positive readings for some of the samples tested in the round robin were sometimes observed. As only extreme base gasolines were tested in the round robin, no definitive statement can be made as to the expected frequency or magnitude of false positives expected in a wider range of base gasolines.
SCOPE
1.1 This test method covers the determination of methanol, ethanol, tert-butanol, methyl tert-butyl ether (MTBE), ethyl tert-butyl ether (ETBE), tert-amyl methyl ether (TAME), and diisopropyl ether (DIPE) in gasoline by infrared spectroscopy. The test method is suitable for determining methanol from 1.7 % to 5.5 % by mass, ethanol from 1.5 % to 10 % by mass, tert-butanol from 1.6 % to 12 % by mass, DIPE from 1.2 % to 17 % by mass, MTBE from 2.0 % to 16.4 % by mass, ETBE from 2.0 % to 18.5 % by mass, and TAME from 1.5 % to 18.5 % by mass.  
1.2 This test method is applicable to oxygenate(s) in gasoline singularly or in multiple mixtures hereof according to the oxygenates and mass percent ranges given in 1.1.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    8 pages
    English language
  • Standard
    8 pages
    English language

SIGNIFICANCE AND USE
5.1 Methyl hydrogen content is a key characteristic of hydrocarbon lubricating oils and can affect a variety of properties of the oil including its boiling range, viscosity, low temperature flow, and oxidation stability.  
5.2 The NMR procedure does not require calibration standards of known methyl hydrogen content and is applicable to a wide range of hydrocarbon lubricating oils that are completely soluble in chloroform at ambient temperature.
SCOPE
1.1 This test method covers the determination of the total methyl hydrogen content of unadditized base stock (lubricating oils) hydrocarbon oils that are completely soluble in chloroform at ambient temperature using high-resolution nuclear magnetic resonance (NMR) spectrometers.  
1.2 The reported units are mol percent methyl hydrogen atoms. For pulse Fourier transform (FT) spectrometers, the detection limit is typically 0.1 % mol hydrogen atoms. The interim precision is applicable in the range 20.5 % to 38.7 % mol methyl hydrogen.  
1.3 This method is applicable to samples containing  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 7.2 and 7.3.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
5.1 The ultraviolet absorption of white mineral oils is used to determine their suitability for use in food, drug, and cosmetic applications.  
5.2 The U.S. Pharmacopeia and the National Formulary specifications for mineral oil require the measurement of ultraviolet absorption.
SCOPE
1.1 This test method describes a procedure for the examination and evaluation of NF and USP grade white mineral oils.  
1.2 This test method is not applicable to oils containing additives soluble in dimethyl sulfoxide (DMSO) that exhibit fluorescence or fluorescence quenching properties.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 7.1.1 – 7.1.3.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
5.1 Biodiesel is a fuel commodity primarily used as a blending component with diesel fuel. It is important to check the concentration of biodiesel in the diesel fuel in order to verify it is within limits or does not exceed the maximum allowable limit.  
5.2 This test method is applicable for quality control in the production and distribution of diesel fuel and biodiesel blends.  
5.3 This test is simple to run, completed in less than one minute, with no dilution of the test sample, no cleaning solvents are required, and the analyzer is portable and self-contained.
SCOPE
1.1 This test method covers the determination of the content of biodiesel (fatty acid methyl esters (FAME)) in diesel fuel oils for volume fractions of 0.1 % to 31.0 % by mid-infrared analyzer with a resolution of 0.1 %.
Note 1: ASTM and ISO specification fuels falling within the scope of this test method include Specifications: D975 grades No. 1D and No. 2D, D7467, distillate grades of D396, MIL-DTL-16884, and distillate grades of marine fuel specification ISO 8217.  
1.2 The accuracy of this test method is based on the molecular weight of C16 and C18 FAME species.  
1.2.1 Discussion—Biodiesel contains a variety of species with different molecular weights. Typical market FAMEs from North America and Europe, which are predominantly soy, rapeseed, and used cooking oil derived FAME were included in the pilot study. FAME derived from coconut, which predominantly contains C12, will over-read by approximately 30 %.  
1.3 This method cannot distinguish between vegetable oils, animal fats, FAEE, compounds containing carbonyl groups, and FAME. For more information, see Section 6.  
1.4 This test method has interim repeatability precision only, see Section 14 for more information.  
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language
  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
5.1 Biodiesel is a fuel commodity primarily used as a value-added blending component with diesel fuel.  
5.2 This test method is applicable for quality control in the production and distribution of diesel fuel and biodiesel blends containing FAME.  
5.3 The use of triglycerides in fuels is not approved for transportation applications within any ASTM specification. This test method allows the quantification of triglyceride concentration in biodiesel blends, thus enabling detection of out-of-specification blending.  
5.4 This test method is fast, simple to run, inexpensive and requires no sample preparation.
SCOPE
1.1 This test method covers the determination of fatty acid methyl ester (FAME) biodiesel and triglyceride (TAG) concentrations in traditional diesel and renewable diesel fuel blends using a portable mid-infrared spectrometer.  
1.2 The method applies to samples with biodiesel concentrations from 3 % to 40 % by volume. Additionally, it applies to samples with biodiesel concentrations from 2 % to 27 % by volume which contain triglycerides concentrations from 1 % to 10 % by volume. Triglycerides from 2 % to 10 % by volume can be determined in samples of diesel having biodiesel concentrations from 3 % to 27 % by volume. FAME and triglyceride can be simultaneously determined outside these stated ranges, but the stated precision estimates do not apply.  
1.3 The method is not able to distinguish TAG and FAME if the TAG concentrations is below 0.142× the measured FAME concentrations.  
1.4 This procedure is not appropriate for the determination of the concentration of biodiesel in the form of fatty acid ethyl esters (FAEE), see Section 6 for further discussion of possible interferences.  
1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    9 pages
    English language
  • Standard
    9 pages
    English language

SIGNIFICANCE AND USE
5.1 Biodiesel is a fuel commodity primarily used as a blending component with diesel fuel. It is important to check the concentration of biodiesel in the diesel fuel in order to make sure it is either not below the minimum allowable limit and or does not exceed the maximum allowable limit.  
5.2 This test method is applicable for quality control in the production and distribution of diesel fuel and biodiesel blends.
SCOPE
1.1 This test method determines fatty acid methyl esters (FAME or biodiesel) in diesel fuel oils. FAME can be quantitatively determined from 1.0 % to 30.0 % by volume. This test method uses linear variable filter (LVF) array based mid-infrared spectroscopy for monitoring FAME concentration.
Note 1: See Section 6 for a list of interferences that could affect the results produced from this method.  
1.2 This test method uses a horizontal attenuated total reflectance (HATR) crystal and a univariate calibration.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    7 pages
    English language

SIGNIFICANCE AND USE
5.1 Biodiesel is a fuel commodity primarily used as a blending component with diesel fuel. It is important to check the concentration of biodiesel in the diesel fuel in order to verify it is within limits or does not exceed the maximum allowable limit.  
5.2 This test method is applicable for quality control in the production and distribution of diesel fuel and biodiesel blends.  
5.3 This test is simple to run, completed in less than one minute, with no dilution of the test sample, no cleaning solvents are required, and the analyzer is portable and self-contained.
SCOPE
1.1 This test method covers the determination of the content of biodiesel (fatty acid methyl esters (FAME)) in diesel fuel oils for volume fractions of 0.1 % to 31.0 % by mid-infrared analyzer with a resolution of 0.1 %.
Note 1: ASTM and ISO specification fuels falling within the scope of this test method include Specifications: D975 grades No. 1D and No. 2D, D7467, distillate grades of D396, MIL-DTL-16884, and distillate grades of marine fuel specification ISO 8217.  
1.2 The accuracy of this test method is based on the molecular weight of C16 and C18 FAME species.  
1.2.1 Discussion—Biodiesel contains a variety of species with different molecular weights. Typical market FAMEs from North America and Europe, which are predominantly soy, rapeseed, and used cooking oil derived FAME were included in the pilot study. FAME derived from coconut, which predominantly contains C12, will over-read by approximately 30 %.  
1.3 It is not possible to distinguish between vegetable oils, animal fats, FAEE, and FAME. For more information, see Section 6.  
1.4 This test method has interim repeatability precision only, see Section 14 for more information.  
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language
  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
5.1 Biodiesel is a fuel commodity primarily used as a value-added blending component with diesel fuel. It is important to check the concentration of biodiesel in the diesel fuel in order to make sure it is within limits or does not exceed the maximum allowable limit.  
5.2 This test method is applicable for quality control in the production and distribution of diesel fuel and biodiesel blends.  
5.3 This test is simple to run, completed in less than one minute, with no dilution of the test sample, no cleaning solvents are required, and the analyzer is portable and self-contained.
SCOPE
1.1 This test method covers the determination of the content of biodiesel (fatty acid methyl esters (FAME)) in diesel fuel oils for volume fractions of 0.1 % to 31.0 % by mid-infrared analyzer with a resolution of 0.1 %.
Note 1: ASTM and ISO specification fuels falling within the scope of this test method include Specifications: D975 grades No. 1D and No. 2D, D7467, distillate grades of D396, MIL-DTL-16884, and distillate grades of marine fuel specification ISO 8217.  
1.2 The accuracy of this test method is based on the molecular weight of C16 and C18 FAME species.  
1.2.1 Discussion—Biodiesel contains a variety of species with different molecular weights. Typical market FAMEs from North America and Europe, which are predominantly soy, rapeseed, and used cooking oil derived FAME were included in the pilot study. FAME derived from coconut, which predominantly contains C12, will over-read by approximately 30 %.  
1.3 It is not possible to distinguish between vegetable oils, animal fats, FAEE, and FAME. For more information, see Section 6.  
1.4 This test method has interim repeatability precision only, see Section 14 for more information.  
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
5.1 The absorbance of liquids and the absorptivity of liquid and solids at specified wavelengths in the ultraviolet are useful in characterizing petroleum products.
SCOPE
1.1 This test method covers the measurement of the ultraviolet absorption of a variety of petroleum products. It covers the absorbance of liquids or the absorptivity of liquids and solids, or both, at wavelengths in the region from 220 nm to 400 nm of the spectrum.  
1.2 The use of this test method implies that the conditions of measurement—wavelength, solvent (if any), sample path length, and sample concentration—are specified by reference to one of the examples of the application of this test method in the annexes or by a statement of other conditions of measurement.  
1.3 Examples of the application of this test method are the absorptivity of refined petroleum wax, and the absorptivity of USP petrolatum.  
1.4 The values stated in SI units are to be regarded as the standard. The values stated in Fahrenheit, feet, and inches, indicated in parentheses, are for information only.  
1.5 Warning—Mercury has been designated by many regulatory agencies as a hazardous substance that can cause serious medical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Use Caution when handling mercury and mercury-containing products. See the applicable product Safety Data Sheet (SDS) for additional information. The potential exists that selling mercury or mercury-containing products, or both, is prohibited by local or national law. Users must determine legality of sales in their location.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 7.3.1, 7.3.3, and 13.4.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    7 pages
    English language
  • Standard
    7 pages
    English language

SIGNIFICANCE AND USE
5.1 Benzene is a compound that endangers health, and the concentration is limited by environmental protection agencies to produce a less toxic gasoline.  
5.2 This test method is fast, simple to run, and inexpensive.  
5.3 This test method is applicable for quality control in the production and distribution of spark-ignition engine fuels.
SCOPE
1.1 This test method covers the determination of the percentage of benzene in spark-ignition engine fuels. It is applicable to concentrations from 0.1 to 5 volume %.  
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    10 pages
    English language
  • Standard
    10 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method for naphthalene hydrocarbons is one of a group of tests used to assess the combustion characteristics of aviation turbine fuels of the kerosene boiling range. The naphthalene hydrocarbon content is determined because naphthalenes, when burned, tend to have a relatively larger contribution to a sooty flame, smoke, and thermal radiation than single ring aromatics.
SCOPE
1.1 This test method covers the determination, by ultraviolet spectrophotometry, of the total concentration of naphthalene, acenaphthene, and alkylated derivatives of these hydrocarbons in jet fuels. This test method is designed to analyze fuels containing not more than 5 % of such components and having end points below 315 °C (600 °F); however, the range of concentrations used in the interlaboratory test programs which established the precision statements for this test method were 0.03 % to 4.25 % by volume for Procedure A, and 0.08 % to 5.6 % by volume for Procedure B. This test method determines the maximum amount of naphthalenes that could be present.  
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 8.1 and 8.2.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 Alcohols and ethers are added to gasoline to produce a reformulated lower emissions gasoline. Alcohols and ethers may also be added to gasoline to increase the octane number. Type and concentration of various oxygenates are specified and regulated to ensure acceptable commercial gasoline quality. Driveability, vapor pressure, phase separation, and evaporative emissions are some of the concerns associated with oxygenated fuels.  
5.2 This test method is faster, simpler, less expensive and more portable than current methods.  
5.3 This test method may be applicable for quality control in the production of gasoline.  
5.4 This test method is not suitable for testing for compliance with federal regulations.3  
5.5 False positive readings for some of the samples tested in the round robin were sometimes observed. As only extreme base gasolines were tested in the round robin, no definitive statement can be made as to the expected frequency or magnitude of false positives expected in a wider range of base gasolines.
SCOPE
1.1 This test method covers the determination of methanol, ethanol, tert-butanol, methyl tert-butyl ether (MTBE), ethyl tert-butyl ether (ETBE), tert-amyl methyl ether (TAME), and diisopropyl ether (DIPE) in gasoline by infrared spectroscopy. The test method is suitable for determining methanol from 0.1 to 6 mass %, ethanol from 0.1 to 11 mass %, tert-butanol from 0.1 to 14 mass %, and DIPE, MTBE, ETBE and TAME from 0.1 to 20 mass %.  
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    5 pages
    English language
  • Standard
    5 pages
    English language

SIGNIFICANCE AND USE
5.1 The ultraviolet absorption of white mineral oils is used to determine their suitability for use in food, drug, and cosmetic applications.  
5.2 The U.S. Pharmacopeia and the National Formulary specifications for mineral oil require the measurement of ultraviolet absorption.
SCOPE
1.1 This test method describes a procedure for the examination and evaluation of NF and USP grade white mineral oils.  
1.2 This test method is not applicable to oils containing additives soluble in dimethyl sulfoxide (DMSO) that exhibit fluorescence or fluorescence quenching properties.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 7.1.1 – 7.1.3.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
5.1 Biodiesel is a fuel commodity primarily used as a blending component with diesel fuel. It is important to check the concentration of biodiesel in the diesel fuel in order to make sure it is either not below the minimum allowable limit and or does not exceed the maximum allowable limit.  
5.2 This test method is applicable for quality control in the production and distribution of diesel fuel and biodiesel blends.
SCOPE
1.1 This test method determines fatty acid methyl esters (FAME or biodiesel) in diesel fuel oils. FAME can be quantitatively determined from 1.0 % to 30.0 % by volume. This test method uses linear variable filter (LVF) array based mid-infrared spectroscopy for monitoring FAME concentration.
Note 1: See Section 6 for a list of interferences that could affect the results produced from this method.  
1.2 This test method uses a horizontal attenuated total reflectance (HATR) crystal and a univariate calibration.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    7 pages
    English language
  • Standard
    7 pages
    English language

SIGNIFICANCE AND USE
5.1 Biodiesel is a blendstock commodity primarily used as a value-added blending component with diesel fuel.  
5.2 This test method is applicable for quality control in the production and distribution of diesel fuel and biodiesel blends containing FAME.
SCOPE
1.1 This test method covers the determination of the content of fatty acid methyl esters (FAME) biodiesel in diesel fuel oils. It is applicable to concentrations from 1.00 to 20 volume % (see Note 1). This procedure is applicable only to FAME. Biodiesel in the form of fatty acid ethyl esters (FAEE) will cause a negative bias.
Note 1: Using the proper ATR sample accessory, the range maybe expanded from 1 to 100 volume %, however precision data is not available above 20 volume %.  
1.2 The values stated in SI units of measurement are to be regarded as the standard. The values given in parentheses are for information only.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    10 pages
    English language
  • Standard
    10 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method for naphthalene hydrocarbons is one of a group of tests used to assess the combustion characteristics of aviation turbine fuels of the kerosene boiling range. The naphthalene hydrocarbon content is determined because naphthalenes, when burned, tend to have a relatively larger contribution to a sooty flame, smoke, and thermal radiation than single ring aromatics.
SCOPE
1.1 This test method covers the determination, by ultraviolet spectrophotometry, of the total concentration of naphthalene, acenaphthene, and alkylated derivatives of these hydrocarbons in jet fuels. This test method is designed to analyze fuels containing not more than 5 % of such components and having end points below 315°C (600°F); however, the range of concentrations used in the interlaboratory test programs which established the precision statements for this test method were 0.03 to 4.25 volume % for Procedure A, and 0.08 to 5.6 volume % for Procedure B. This test method determines the maximum amount of naphthalenes that could be present.  
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 8.1 and 8.2.

  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 Benzene is a compound that endangers health, and the concentration is limited by environmental protection agencies to produce a less toxic gasoline.  
5.2 This test method is fast, simple to run, and inexpensive.  
5.3 This test method is applicable for quality control in the production and distribution of spark-ignition engine fuels.
SCOPE
1.1 This test method covers the determination of the percentage of benzene in spark-ignition engine fuels. It is applicable to concentrations from 0.1 to 5 volume %.  
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    10 pages
    English language

SIGNIFICANCE AND USE
5.1 Biodiesel is a fuel commodity primarily used as a value-added blending component with diesel fuel.  
5.2 This test method is fast and simple to run.  
5.3 This test method is applicable for quality control in the production and distribution of diesel fuel and biodiesel blends containing FAME.
SCOPE
1.1 This test method covers the determination of the content of biodiesel (fatty acid methyl esters—FAME) in diesel fuel oils. It is applicable to concentrations from 1 to 30 volume %. This procedure is applicable only to FAME. This test method is not appropriate for the determination of the concentration of biodiesel that is in the form of fatty acid ethyl esters (FAEE).  
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    8 pages
    English language

SIGNIFICANCE AND USE
5.1 The absorbance of liquids and the absorptivity of liquid and solids at specified wavelengths in the ultraviolet are useful in characterizing petroleum products.
SCOPE
1.1 This test method covers the measurement of the ultraviolet absorption of a variety of petroleum products. It covers the absorbance of liquids or the absorptivity of liquids and solids, or both, at wavelengths in the region from 220 to 400 nm of the spectrum.  
1.2 The use of this test method implies that the conditions of measurement—wavelength, solvent (if any), sample path length, and sample concentration—are specified by reference to one of the examples of the application of this test method in the annexes or by a statement of other conditions of measurement.  
1.3 Examples of the application of this test method are the absorptivity of refined petroleum wax, and the absorptivity of USP petrolatum.  
1.4 The values stated in SI units are to be regarded as the standard. The values stated in Fahrenheit, feet, and inches, indicated in parentheses, are for information only.  
1.5 Warning—Mercury has been designated by EPA and many state agencies as a hazardous material that can cause central nervous system, kidney, and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury-containing products. See the applicable product Material Safety Data Sheet (MSDS) for details and EPA’s website (http://www.epa.gov/mercury/faq.htm) for additional information. Users should be aware that selling mercury or mercury-containing products, or both, in your state may be prohibited by state law.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 7.3.1, 7.3.3, and 13.4.

  • Standard
    7 pages
    English language
  • Standard
    7 pages
    English language

SIGNIFICANCE AND USE
Biodiesel is a blendstock commodity primarily used as a value-added blending component with diesel fuel.
This test method is applicable for quality control in the production and distribution of diesel fuel and biodiesel blends containing FAME.
SCOPE
1.1 This test method covers the determination of the content of fatty acid methyl esters (FAME) biodiesel in diesel fuel oils. It is applicable to concentrations from 1.00 to 20 volume % (see Note 1). This procedure is applicable only to FAME. Biodiesel in the form of fatty acid ethyl esters (FAEE) will cause a negative bias.
Note 1—Using the proper ATR sample accessory, the range maybe expanded from 1 to 100 volume %, however precision data is not available above 20 volume %.
1.2 The values stated in SI units of measurement are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    10 pages
    English language
  • Standard
    10 pages
    English language

SIGNIFICANCE AND USE
Alcohols and ethers are added to gasoline to produce a reformulated lower emissions gasoline. Alcohols and ethers may also be added to gasoline to increase the octane number. Type and concentration of various oxygenates are specified and regulated to ensure acceptable commercial gasoline quality. Driveability, vapor pressure, phase separation, and evaporative emissions are some of the concerns associated with oxygenated fuels.
This test method is faster, simpler, less expensive and more portable than current methods.
This test method may be applicable for quality control in the production of gasoline.
This test method is not suitable for testing for compliance with federal regulations.  
False positive readings for some of the samples tested in the round robin were sometimes observed. As only extreme base gasolines were tested in the round robin, no definitive statement can be made as to the expected frequency or magnitude of false positives expected in a wider range of base gasolines.
SCOPE
1.1 This test method covers the determination of methanol, ethanol, tert-butanol, methyl tert-butyl ether (MTBE), ethyl tert-butyl ether (ETBE), tert-amyl methyl ether (TAME), and diisopropyl ether (DIPE) in gasoline by infrared spectroscopy. The test method is suitable for determining methanol from 0.1 to 6 mass %, ethanol from 0.1 to 11 mass %, tert-butanol from 0.1 to 14 mass %, and DIPE, MTBE, ETBE and TAME from 0.1 to 20 mass %.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    5 pages
    English language

SIGNIFICANCE AND USE
The ultraviolet absorption of white mineral oils is used to determine their suitability for use in food, drug, and cosmetic applications.
The U.S. Pharmacopeia and the National Formulary specifications for mineral oil require the measurement of ultraviolet absorption.
SCOPE
1.1 This test method describes a procedure for the examination and evaluation of NF and USP grade white mineral oils.
1.2 This test method is not applicable to oils containing additives soluble in dimethyl sulfoxide (DMSO) that exhibit fluorescence or fluorescence quenching properties.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 7.1.1-7.1.3.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
Aromatic content is a key characteristic of hydrocarbon oils and can affect a variety of properties of the oil including its boiling range, viscosity, stability, and compatibility of the oil with polymers.
Existing methods for estimating aromatic contents use physical measurements, such as refractive index, density, and number average molecular weight (see Test Method D 3238) or infrared absorbance and often depend on the availability of suitable standards. These NMR procedures do not require standards of known aromatic hydrogen or aromatic carbon contents and are applicable to a wide range of hydrocarbon oils that are completely soluble in chloroform at ambient temperature.
The aromatic hydrogen and aromatic carbon contents determined by this test method can be used to evaluate changes in aromatic contents of hydrocarbon oils due to changes in processing conditions and to develop processing models in which the aromatic content of the hydrocarbon oil is a key processing indicator.
SCOPE
1.1 This test method covers the determination of the aromatic hydrogen content (Procedures A and B) and aromatic carbon content (Procedure C) of hydrocarbon oils using high-resolution nuclear magnetic resonance (NMR) spectrometers. Applicable samples include kerosenes, gas oils, mineral oils, lubricating oils, coal liquids, and other distillates that are completely soluble in chloroform at ambient temperature. For pulse Fourier transform (FT) spectrometers, the detection limit is typically 0.1 mol % aromatic hydrogen atoms and 0.5 mol % aromatic carbon atoms. For continuous wave (CW) spectrometers, which are suitable for measuring aromatic hydrogen contents only, the detection limit is considerably higher and typically 0.5 mol % aromatic hydrogen atoms.
1.2 The reported units are mole percent aromatic hydrogen atoms and mole percent aromatic carbon atoms.
1.3 This test method is not applicable to samples containing more than 1 mass % olefinic or phenolic compounds.
1.4 This test method does not cover the determination of the percentage mass of aromatic compounds in oils since NMR signals from both saturated hydrocarbons and aliphatic substituents on aromatic ring compounds appear in the same chemical shift region. For the determination of mass or volume percent aromatics in hydrocarbon oils, chromatographic, or mass spectrometry methods can be used.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 7.2 and 7.3.

  • Standard
    7 pages
    English language

SIGNIFICANCE AND USE
The absorbance of liquids and the absorptivity of liquid and solids at specified wavelengths in the ultraviolet are useful in characterizing petroleum products.
SCOPE
1.1 This test method covers the measurement of the ultraviolet absorption of a variety of petroleum products. It covers the absorbance of liquids or the absorptivity of liquids and solids, or both, at wavelengths in the region from 220 to 400 nm of the spectrum.
1.2 The use of this test method implies that the conditions of measurement—wavelength, solvent (if any), sample path length, and sample concentration—are specified by reference to one of the examples of the application of this test method in the annexes or by a statement of other conditions of measurement.
1.3 Examples of the application of this test method are the determination of the absorbance of white mineral oil, the absorptivity of refined petroleum wax, and the absorptivity of USP petrolatum.
1.4 The values stated in SI units are to be regarded as the standard. The values stated in Fahrenheit, feet, and inches, indicated in parentheses, are for information only.
1.5 Warning—Mercury has been designated by EPA and many state agencies as a hazardous material that can cause central nervous system, kidney, and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury-containing products. See the applicable product Material Safety Data Sheet (MSDS) for details and EPA’s website (http://www.epa.gov/mercury/faq.htm) for additional information. Users should be aware that selling mercury or mercury-containing products, or both, in your state may be prohibited by state law.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 7.3.1, 7.3.3, and 13.4.

  • Standard
    8 pages
    English language
  • Standard
    8 pages
    English language

SIGNIFICANCE AND USE
This test method for naphthalene hydrocarbons is one of a group of tests used to assess the combustion characteristics of aviation turbine fuels of the kerosene boiling range. The naphthalene hydrocarbon content is determined because naphthalenes, when burned, tend to have a relatively larger contribution to a sooty flame, smoke, and thermal radiation than single ring aromatics.
SCOPE
1.1 This test method covers the determination, by ultraviolet spectrophotometry, of the total concentration of naphthalene, acenaphthene, and alkylated derivatives of these hydrocarbons in jet fuels. This test method is designed to analyze fuels containing not more than 5 % of such components and having end points below 315°C (600°F); however, the range of concentrations used in the interlaboratory test programs which established the precision statements for this test method were 0.03 to 4.25 volume % for Procedure A, and 0.08 to 5.6 volume % for Procedure B. This test method determines the maximum amount of naphthalenes that could be present.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 8.1 and 8.2.

  • Standard
    5 pages
    English language
  • Standard
    5 pages
    English language

SIGNIFICANCE AND USE
Benzene is a compound that endangers health, and the concentration is limited by environmental protection agencies to produce a less toxic gasoline.
This test method is fast, simple to run, and inexpensive.
This test method is applicable for quality control in the production and distribution of spark-ignition engine fuels.
SCOPE
1.1 This test method covers the determination of the percentage of benzene in spark-ignition engine fuels. It is applicable to concentrations from 0.1 to 5 volume %.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    10 pages
    English language
  • Standard
    10 pages
    English language

SIGNIFICANCE AND USE
Biodiesel is a fuel commodity primarily used as a value-added blending component with diesel fuel.
This test method is applicable for quality control in the production and distribution of diesel fuel and biodiesel blends containing FAME.
SCOPE
1.1 This test method covers the determination of the content of fatty acid methyl esters (FAME) biodiesel in diesel fuel oils. It is applicable to concentrations from 1.00 to 20 volume % (see Note 1). This procedure is applicable only to FAME. Biodiesel in the form of fatty acid ethyl esters (FAEE) will cause a negative bias.Note 1
Using the proper ATR sample accessory, the range maybe expanded from 1 to 100 volume %, however precision data is not available above 20 volume %.
1.2 The values stated in SI units of measurement are to be regarded as the standard. The values given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    10 pages
    English language

SIGNIFICANCE AND USE
Benzene is a compound that endangers health, and the concentration is limited by environmental protection agencies to produce a less toxic gasoline.
This test method is fast, simple to run, and inexpensive.
This test method is applicable for quality control in the production and distribution of spark-ignition engine fuels.
SCOPE
1.1 This test method covers the determination of the percentage of benzene in spark-ignition engine fuels. It is applicable to concentrations from 0.1 to 5 volume %.
1.2 SI units of measurement are preferred and used throughout this standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    10 pages
    English language

SIGNIFICANCE AND USE
Alcohols and ethers are added to gasoline to produce a reformulated lower emissions gasoline. Alcohols and ethers may also be added to gasoline to increase the octane number. Type and concentration of various oxygenates are specified and regulated to ensure acceptable commercial gasoline quality. Driveability, vapor pressure, phase separation, and evaporative emissions are some of the concerns associated with oxygenated fuels.
This test method is faster, simpler, less expensive and more portable than current methods.
This test method may be applicable for quality control in the production of gasoline.
This test method is not suitable for testing for compliance with federal regulations.3  
False positive readings for some of the samples tested in the round robin were sometimes observed. As only extreme base gasolines were tested in the round robin, no definitive statement can be made as to the expected frequency or magnitude of false positives expected in a wider range of base gasolines.
SCOPE
1.1 This test method covers the determination of methanol, ethanol, tert-butanol, methyl  tert-butyl ether (MTBE), ethyl tert-butyl ether (ETBE), tert-amyl methyl ether (TAME), and diisopropyl ether (DIPE) in gasoline by infrared spectroscopy. The test method is suitable for determining methanol from 0.1 to 6 mass %, ethanol from 0.1 to 11 mass %, tert-butanol from 0.1 to 14 mass %, and DIPE, MTBE, ETBE and TAME from 0.1 to 20 mass %.
1.2 SI units of measurement are preferred and used throughout this standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    5 pages
    English language

SIGNIFICANCE AND USE
The absorbance of liquids and the absorptivity of liquid and solids at specified wavelengths in the ultraviolet are useful in characterizing petroleum products.
SCOPE
1.1 This test method covers the measurement of the ultraviolet absorption of a variety of petroleum products. It covers the absorbance of liquids or the absorptivity of liquids and solids, or both, at wavelengths in the region from 220 to 400 nm of the spectrum.
1.2 The use of this test method implies that the conditions of measurement-wavelength, solvent (if any), sample path length, and sample concentration-are specified by reference to one of the examples of the application of this test method in the annexes or by a statement of other conditions of measurement.
1.3 Examples of the application of this test method are the determination of the absorbance of white mineral oil, the absorptivity of refined petroleum wax, and the absorptivity of USP petrolatum.
1.4 The values stated in SI units are to be regarded as the standard. The values stated in fahrenheit, feet, and inches, indicated in parentheses, are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 7.3.1, 7.3.3, and 13.4.

  • Standard
    8 pages
    English language

SIGNIFICANCE AND USE
The ultraviolet absorption of white mineral oils is used to determine their suitability for use in food, drug, and cosmetic applications.
The U.S. Pharmacopeia and the National Formulary specifications for mineral oil require the measurement of ultraviolet absorption.
SCOPE
1.1 This test method describes a procedure for the examination and evaluation of NF and USP grade white mineral oils.
1.2 This test method is not applicable to oils containing additives soluble in dimethyl sulfoxide (DMSO) that exhibit fluorescence or fluorescence quenching properties.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statement, see 7.1.1-7.1.3

  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
Aromatic content is a key characteristic of hydrocarbon oils and can affect a variety of properties of the oil including its boiling range, viscosity, stability, and compatibility of the oil with polymers.
Existing methods for estimating aromatic contents use physical measurements, such as refractive index, density, and number average molecular weight (see Test Method D 3238) or infrared absorbance and often depend on the availability of suitable standards. These NMR procedures do not require standards of known aromatic hydrogen or aromatic carbon contents and are applicable to a wide range of hydrocarbon oils that are completely soluble in chloroform at ambient temperature.
The aromatic hydrogen and aromatic carbon contents determined by this test method can be used to evaluate changes in aromatic contents of hydrocarbon oils due to changes in processing conditions and to develop processing models in which the aromatic content of the hydrocarbon oil is a key processing indicator.
TABLE 1 Sample and Instrument Conditions for Continuous Wave (CW) Measurements of 1 H NMR Spectra   Solvent Chloroform-d Sample concentrationUp to 50 % v/v for distillable oils Sample temperatureInstrument ambient Internal lockNone Sample spinning rateAs recommended by manufacturer, typically 20 Hz r-f Power levelAs recommended by instrument manufacturer Signal to noise levelA minimum of 5:1 for the maximum height of the smaller integrated absorption band Chemical shift referencePreferably tetramethylsilane (0.0 ppm) at no greater than 1 vol % concentration IntegrationIntegrate over the range − 0.5 to 5.0 ppm for the aliphatic band and 5.0 to 10.0 ppm for the aromatic band
SCOPE
1.1 This test method covers the determination of the aromatic hydrogen content (Procedures A and B) and aromatic carbon content (Procedure C) of hydrocarbon oils using high-resolution nuclear magnetic resonance (NMR) spectrometers. Applicable samples include kerosenes, gas oils, mineral oils, lubricating oils, coal liquids, and other distillates that are completely soluble in chloroform at ambient temperature. For pulse Fourier transform (FT) spectrometers, the detection limit is typically 0.1 mol % aromatic hydrogen atoms and 0.5 mol % aromatic carbon atoms. For continuous wave (CW) spectrometers, which are suitable for measuring aromatic hydrogen contents only, the detection limit is considerably higher and typically 0.5 mol % aromatic hydrogen atoms.
1.2 The reported units are mole percent aromatic hydrogen atoms and mole percent aromatic carbon atoms.
1.3 This test method is not applicable to samples containing more than 1 mass % olefinic or phenolic compounds.
1.4 This test method does not cover the determination of the percentage mass of aromatic compounds in oils since NMR signals from both saturated hydrocarbons and aliphatic substituents on aromatic ring compounds appear in the same chemical shift region. For the determination of mass or volume percent aromatics in hydrocarbon oils, chromatographic, or mass spectrometry methods can be used.
1.5 The values stated in SI units are to be regarded as the standard.
1.6 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 7.2 and 7.4.

  • Standard
    7 pages
    English language

SCOPE
1.1 This test method covers the determination of the aromatic hydrogen content (Procedures A and B) and aromatic carbon content (Procedure C) of hydrocarbon oils using high-resolution nuclear magnetic resonance (NMR) spectrometers. Applicable samples include kerosenes, gas oils, mineral oils, lubricating oils, coal liquids, and other distillates that are completely soluble in chloroform at ambient temperature. For pulse Fourier transform (FT) spectrometers, the detection limit is typically 0.1 mol % aromatic hydrogen atoms and 0.5 mol % aromatic carbon atoms. For continuous wave (CW) spectrometers, which are suitable for measuring aromatic hydrogen contents only, the detection limit is considerably higher and typically 0.5 mol % aromatic hydrogen atoms.
1.2 The reported units are mole percent aromatic hydrogen atoms and mole percent aromatic carbon atoms.
1.3 This test method is not applicable to samples containing more than 1 mass % olefinic or phenolic compounds.
1.4 This test method does not cover the determination of the percentage mass of aromatic compounds in oils since NMR signals from both saturated hydrocarbons and aliphatic substituents on aromatic ring compounds appear in the same chemical shift region. For the determination of mass or volume percent aromatics in hydrocarbon oils, chromatographic, or mass spectrometry methods can be used.
1.5 The values stated in SI units are to be regarded as the standard.
This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 7.2 and 7.4.

  • Standard
    7 pages
    English language

SIGNIFICANCE AND USE
Benzene is classed as a toxic material. A knowledge of the concentration of this compound may be an aid in evaluating the possible health hazard to persons handling and using the gasoline. This test method is not intended to evaluate such hazards.
SCOPE
1.1 This test method covers the determination of the percent benzene in full-range gasoline. It is applicable to concentrations from 0.1% to 5 volume %.
1.2 The values in SI units are regarded as the standard.
1.3 This test method has not been validated for gasolines containing oxygenates.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8 and 9.1.

  • Standard
    3 pages
    English language

SCOPE
1.1 This test method covers the determination of the percent benzene in full-range gasoline. It is applicable to concentrations from 0.1% to 5 volume %.
1.2 The values in SI units are regarded as the standard.
1.3 This test method has not been validated for gasolines containing oxygenates.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8 and 9.1.

  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
This test method for naphthalene hydrocarbons is one of a group of tests used to assess the combustion characteristics of aviation turbine fuels of the kerosene boiling range. The naphthalene hydrocarbon content is determined because naphthalenes, when burned, tend to have a relatively larger contribution to a sooty flame, smoke, and thermal radiation than single ring aromatics.
SCOPE
1.1 This test method covers the determination, by ultraviolet spectrophotometry, of the total concentration of naphthalene, acenaphthene, and alkylated derivatives of these hydrocarbons in jet fuels. This test method is designed to analyze fuels containing not more than 5 % of such components and having end points below 315°C (600°F); however, the range of concentrations used in the interlaboratory test programs which established the precision statements for this test method were 0.03 to 4.25 volume % for Procedure A, and 0.08 to 5.6 volume % for Procedure B. This test method determines the maximum amount of naphthalenes that could be present.
1.2 The values stated in SI units are to be regarded as the standard. The values stated in inch-pound units are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 8.1 and 8.2.

  • Standard
    5 pages
    English language

SCOPE
1.1 This test method covers the determination, by ultraviolet spectrophotometry, of the total concentration of naphthalene, acenaphthene, and alkylated derivatives of these hydrocarbons in straight-run jet fuels. This test method is designed to analyze fuels containing not more than 5 % of such components and having end points below 315°C (600°F); however, the range of concentrations used in the interlaboratory test programs which established the precision statements for this test method were 0.03 to 4.25 volume % for Procedure A, and 0.08 to 5.6 volume % for Procedure B. This test method determines the maximum amount of naphthalenes that could be present.
1.2 The values stated in SI units are to be regarded as the standard. The values stated in inch-pound units are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 8.1 and 8.2.

  • Standard
    4 pages
    English language

SCOPE
1.1 This test method covers the determination of methanol, ethanol,  tert-butanol, methyl tert-butyl ether (MTBE), ethyl tert-butyl ether (ETBE), tert-amyl methyl ether (TAME), and diisopropyl ether (DIPE) in gasoline by infrared spectroscopy. The test method is suitable for determining methanol from 0.1 to 6 mass %, ethanol from 0.1 to 11 mass %,  tert-butanol from 0.1 to 14 mass %, and DIPE, MTBE, ETBE and TAME from 0.1 to 20 mass %.  
1.2 SI units of measurement are preferred and used throughout this standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    5 pages
    English language

SCOPE
1.1 This test method covers the determination of methanol, ethanol,  tert-butanol, methyl tert-butyl ether (MTBE), ethyl tert-butyl ether (ETBE), tert-amyl methyl ether (TAME), and diisopropyl ether (DIPE) in gasoline by infrared spectroscopy. The test method is suitable for determining methanol from 0.1 to 6 mass %, ethanol from 0.1 to 11 mass %,  tert-butanol from 0.1 to 14 mass %, and DIPE, MTBE, ETBE and TAME from 0.1 to 20 mass %.  
1.2 SI units of measurement are preferred and used throughout this standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    5 pages
    English language

SCOPE
1.1 This test method covers the determination, by ultraviolet spectrophotometry, of the total concentration of naphthalene, acenaphthene, and alkylated derivatives of these hydrocarbons in straight-run jet fuels containing not more than 5 % of such components and having end points below 315°C (600°F). This test method determines the maximum amount of naphthalenes that could be present.
1.2 The values stated in SI units are to be regarded as the standard. The values stated in inch-pound units are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements see 8.1 and 8.2.

  • Standard
    4 pages
    English language

SCOPE
1.1 This test method covers the determination, by ultraviolet spectrophotometry, of the total concentration of naphthalene, acenaphthene, and alkylated derivatives of these hydrocarbons in straight-run jet fuels containing not more than 5 % of such components and having end points below 315°C (600°F). This test method determines the maximum amount of naphthalenes that could be present.
1.2 The values stated in SI units are to be regarded as the standard. The values stated in inch-pound units are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements see 8.1 and 8.2.

  • Standard
    4 pages
    English language

SCOPE
1.1 This test method covers the determination of the percentage of benzene in spark-ignition engine fuels. It is applicable to concentrations from 0.1 to 5 volume %.
1.2 SI units of measurement are preferred and used throughout this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    10 pages
    English language

SCOPE
1.1 This test method covers the determination of the percentage of benzene in spark-ignition engine fuels. It is applicable to concentrations from 0.1 to 5 volume %.
1.2 SI units of measurement are preferred and used throughout this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    10 pages
    English language

SCOPE
1.1 This test method describes a procedure for the examination and evaluation of NF and USP grade white mineral oils.
1.2 This test method is not applicable to oils containing additives soluble in dimethyl sulfoxide (DMSO) that exhibit fluorescence or fluorescence quenching properties.
1.3 The values in SI units are regarded as the standard. The values given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see .

  • Standard
    3 pages
    English language

Frequently Asked Questions

D02.04.0F is a Technical Committee within ASTM International. It is named "Absorption Spectroscopic Methods". This committee has published 56 standards.

D02.04.0F develops ASTM standards in the area of Information technology. Currently, there are 56 published standards from this technical committee.

ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.

A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.

Loading...