SIGNIFICANCE AND USE
4.1 This test method is suitable for determining the quantity of aldehydes, both for quality control and quality assurance of the product.
SCOPE
1.1 This test method covers the wet chemical determination of total aldehydes in styrene monomer. Total aldehydes are calculated and reported as benzaldehyde.  
1.2 This test method is applicable to samples with aldehyde concentrations to 0.013 mass%. The Limit of Detection (LOD) is 0.0006 mass% and the Limit of Quantification (LOQ) is 0.0020 mass%. The LOD and LOQ were calculated based on the data in Table 1.  
1.3 In determining conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method is suitable for determining the quantity of aldehydes, both for quality control and quality assurance of the product.
SCOPE
1.1 This test method covers the wet chemical determination of aldehydes in styrene monomer. Aldehydes are calculated and reported as benzaldehyde.  
1.2 This test method is applicable to samples with aldehyde concentrations to 0.030 mass%. The limit of detection (LOD) is 0.0006 mass% and the limit of quantitation (LOQ) is 0.002 mass% based on the data in 13.1.  
1.3 In determining conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

ABSTRACT
This specification covers ethylbenzene. Different tests shall be conducted in order to determine the following properties of ethylbenzene: purity, benzene content, toluene content, xylene content, cumene content, diethylbenzene content, chloride content, sulfur content, and color.
SCOPE
1.1 This specification covers ethylbenzene.  
1.2 The following applies to all specified limits in this specification for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measure are included in this specification.  
1.4 Consult current OSHA regulations, supplier’s Safety Data Sheet for all materials, and local regulations used in this specification.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method can be used for determining polymer concentrations in styrene monomer.  
5.2 This test method will not detect dimers and trimers.  
5.3 This test method can be used for plant control and for specification analysis.
SCOPE
1.1 These test methods cover the determination of the polymer content of styrene monomer. It should be noted, however, that dimers and trimers are not measured by these test methods.  
1.2 Test Method A, which is based on the use of a spectrophotometer or photometer, is intended for the quantitative determination of the polymer content of styrene monomer in concentrations up to 15 mg/kg. Samples containing more than 15 mg/kg of polymer must be suitably diluted before measurement. The limit of detection (LOD) is 1.2 mg/kg and the limit of quantitation (LOQ) is 4.0 mg/kg. LOD and LOQ were calculated using the last sample in Table 1.  
1.3 Test Method B is a rapid visual procedure that is intended for the approximate evaluation of polymer to a maximum concentration of 1.0 mass %. Samples having a polymer content of 1.0 mass % or greater should be suitably diluted prior to measurement.  
1.4 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method can be used for determining polymer concentrations in AMS monomer.  
4.2 This test method will not detect dimers and trimers.  
4.3 This test method can be used for plant control and for specification analysis. Information regarding plant control and specification analysis can be found in test method D6367.
SCOPE
1.1 This test method covers the determination of the polymer content of AMS (α-Methylstyrene). Dimers and trimers are not measured by these test methods.  
1.2 This test method has been found applicable to determining the polymer content of AMS in concentrations up to 15 mg/kg with an LOQ of 0.6 mg/kg and an LOD of 0.2 mg/kg based on the data in Table 1. Samples containing more than 15 mg/kg of polymer must be suitably diluted before measurement.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

ABSTRACT
This specification covers cumene (isopropylbenzene) manufactured via a zeolite catalyst process. Cumene shall conform to the following requirements: purity weight percent, alpha-methylstrene, benzene, cumene hydroperoxide, diisopropylbenzenes, ethylbenzene, i-butylbenzene, n-butylbenzene, s- butylbenzene, t- butylbenzene, phenols, n-propylbenzene, sulfur, toluene, total butylbenzenes, total cymenes, total non-aromatics, total GC unknowns, bromine index, appearance, and color.
SCOPE
1.1 This specification covers cumene (isopropylbenzene) manufactured using a zeolite catalyst process.  
1.2 The following applies to all specified limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 Consult current OSHA Regulations and Supplier’s Safety Data Sheets, and local regulations for all materials used in this specification.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    3 pages
    English language
  • Technical specification
    3 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method is suitable for setting specifications on the materials referenced in 1.2 and for use as an internal quality control tool where isopropylbenzene is produced or is used in a manufacturing process. It may also be used in development or research work involving isopropylbenzene.  
5.2 This test method is useful in determining the purity of isopropylbenzene with normal impurities present. If extremely high boiling or unusual impurities are present in the isopropylbenzene, this test method would not necessarily detect them and the purity calculation would be erroneous.  
5.3 Cumene hydroperoxide, if present, will yield thermal decomposition products, primarily AP and DMPC as stated in 4.1, that will elute in the chromatogram thereby giving incorrect results unless they are excluded as indicated in 4.1. It is also possible to get erroneous results for trace alpha-methylstyrene present in isopropylbenzene if the inlet has become unduly contaminated with non-volatile foreign substances.  
5.4 The nonaromatic hydrocarbons commonly present from the isopropylbenzene manufacturing process, particularly a non-zeolitic one, will interfere with the determination of xylenes (if present).
SCOPE
1.1 This test method covers the determination of the purity of isopropylbenzene (cumene) by gas chromatography. Calibration of the gas chromatography system is done by the external standard calibration technique.  
1.2 This test method has been found applicable to the measurement of impurities such as nonaromatic hydrocarbons, benzene, toluene, ethylbenzene, phenol, cymenes, t-butylbenzene, n-butylbenzene, n-propylbenzene, alpha-methylstyrene, sec-butylbenzene, and diisopropylbenzenes, which are impurities that can be found in isopropylbenzene. The latter impurities can be analyzed over a range of 1 mg/kg to 500 mg/kg by this method (see Table 1). The limit of quantitation averages 3.8 mg/kg while the limit of detection for these impurities averages 1.1 mg/kg based on the data in Table 1.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    5 pages
    English language
  • Standard
    5 pages
    English language

ABSTRACT
This specification covers cumene (isopropylbenzene). Tests shall be performed to determine the requirements of cumene in accordance to the following test methods: purity; alpha-methylstrene, benzene, butylbenzenes, diisopropylbenzenes, ethylbenzene, phenols, n-propylbenzene, sulfur, bromine index, and appearance.
SCOPE
1.1 This specification covers cumene (isopropylbenzene).  
1.2 The following applies to all specified limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 Consult current OSHA Regulations and Supplier’s Safety Data Sheets, and local regulations for all materials used in this specification.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

SIGNIFICANCE AND USE
5.1 Evaporation residue is an empirical measure of nonvolatile impurities in naphthalene. This test method is suitable for setting specifications and for use as an internal quality control tool.
SCOPE
1.1 This test method covers the determination of the evaporation residue of naphthalene.  
1.2 This test method has been found applicable to determining residue in the range of 0.3 and 1.5 wt %.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7, 8.1, 9.2, and 9.3.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method is suitable for determining the quantity of peroxides in styrene monomer both for quality control and quality assurance of the product.
SCOPE
1.1 This test method covers the determination of the peroxide content of styrene monomer reported as hydrogen peroxide.  
1.2 This test method has been found applicable to the determination of peroxides in styrene monomer in the range of 1 mg/kg to 60 mg/kg. Based on the precision data in 12.1, LOD is 6 mg/kg and LOQ is 21 mg/kg.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method is suitable for determining the quantity of TBC inhibitor, both for the protection against polymerization while in transit and storage, and for internal quality control.
SCOPE
1.1 This test method is applicable to the determination of residual 4-tertiary-butylcatechol (TBC) in styrene monomer or AMS in the 1 mg/kg to 100 mg/kg range.  
1.2 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29. The limit of detection is 0.2 mg/kg while the limit of quantitation is 0.8 mg/kg based on the ILS data in Table 1.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific statements on hazards, see Section 9.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method is suitable for setting specifications on the materials referenced in 1.2 and for use as an internal quality control tool where AMS is produced or is used in a manufacturing process. It may also be used in development or research work involving AMS.  
5.2 This test method is useful in determining the purity of AMS with normal impurities present. If extremely high boiling or unusual impurities are present in the AMS, this test method would not necessarily detect them and the purity calculation would be erroneous.
SCOPE
1.1 This test method covers the determination of the purity of AMS (α-methylstyrene) by gas chromatography. Calibration of the gas chromatography system is done by the external standard calibration technique.  
1.2 This test method has been found applicable to the measurement of impurities such as cumene, 3-methyl-2-cyclopentene-1-one, n-propylbenzene, tert-butylbenzene, sec-butylbenzene, cis-2-phenyl-2-butene, acetophenone, 1-phenyl-1-butene, 2-phenyl-2-propanol, trans-2-phenyl-2-butene, m-cymene, p-cymene, and phenol, which are common to the manufacturing process of AMS. The method has also been found applicable for the determination of para-tertiary-butylcatechol (TBC or PTBC) typically added as a stabilizer to AMS. The impurities in AMS can be analyzed over a range of 5 to 800 mg/kg by this method. (See Table 2.) Based on the results in ASTM Research Report RR:D16-1022, summarized in Table 2, the limit of quantitation for these impurities averages 4 mg/kg, while the limit of detection averages 1.2 mg/kg.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language
  • Standard
    6 pages
    English language

ABSTRACT
This specification establishes the requirements for AMS (alpha-Methylstyrene). Sampled specimens shall conform to the following physical and chemical properties: minimum AMS content; maximum phenol content; maximum polymer content; inhibitor content; appearance; and color (Pt-Co units).
SCOPE
1.1 This specification covers AMS (α-Methylstyrene).  
1.2 The following applies to all limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 Consult current OSHA regulations, suppliers’ Safety Data Sheets, and local regulations for all materials used in this specification.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

SIGNIFICANCE AND USE
4.1 Nitroxide radicals (H-Tempo, O-Tempo (4-oxo-2,2,6,6-tetramethylpiperidine-1-oxyl), etc.) are widely used as inhibitors of thermopolymerization in the processes of transportation, storage, and separation of monomers (isoprene, butadiene, styrene, etc.). This test method provides a procedure for assaying nitroxide radicals in monomers.  
4.2 This procedure can be used for determination of the content of nitroxide radicals (H-Tempo, O-Tempo, etc.) in other solvents (dimethyl formamide, DMSO etc.).
SCOPE
1.1 This test method is designed to determine the content of nitroxide radical 4-hydroxy-2,2,6,6-tetramethylpiperidine-1-oxyl (H-Tempo) in butadiene, isoprene, and styrene.  
1.2 This test method is applicable to samples with nitroxide radical 4-hydroxy-2,2,6,6-tetramethylpiperidine-1-oxyl (H-Tempo) with concentrations to 100 mg⁄kg. The limit of detection (LOD) is 0.47 mg/kg for nitroxide radical 4-hydroxy-2,2,6,6-tetramethylpiperidine-1-oxyl (H-Tempo) and the limit of quantitation (LOQ) is 1.6 mg/kg nitroxide radical 4-hydroxy-2,2,6,6-tetramethylpiperidine-1-oxyl (H-Tempo).  
1.3 The following applies for the purposes of determining the conformance of the test results using this test method to applicable specifications, results shall be rounded of in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    7 pages
    English language

SIGNIFICANCE AND USE
4.1 The test is suitable for setting specifications on ethylbenzene and for use as an internal quality control tool where ethylbenzene is used in manufacturing processes. It may be used in development or research work involving ethylbenzene.  
4.2 Purity is commonly reported by subtracting the determined expected impurities from 100 %. Absolute purity cannot be determined if unknown impurities are present.
SCOPE
1.1 This test method describes the analysis of normally occurring impurities in, and the purity of, ethylbenzene by gas chromatography. Impurities determined include nonaromatic hydrocarbons, benzene, toluene, xylenes, cumene, and diethylbenzene isomers.  
1.2 This test method is applicable for impurities at concentrations from 0.001 to 1.000 % and for ethylbenzene purities of 99 % or higher. At this level, p-xylene may not be detected.  
1.3 In determining the performance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Section 8.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method is designed to obtain styrene purity on the basis of impurities normally present in styrene and may be used for final product inspections and process control.  
5.2 This test method will detect the impurities shown in Table 1, non-aromatic hydrocarbons containing ten carbons or less, and others where specific impurity standards are available. Absolute purity cannot be determined if unknown impurities are present.
SCOPE
1.1 This test method covers the determination of the impurities typically found in styrene and uses those values to determine the purity of styrene by difference by gas chromatography. Typical impurities in commercial styrene are found in Table 1.    
1.2 This test method is applicable to impurity concentrations up to 1 %.  
1.2.1 The limit of detection is 0.0003 mass % and the limit of quantitation is 0.0010 mass %.  
1.2.2 LOD and LOQ were calculated using data from ILS results for n-propylbenzene in Table 3.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Section 9.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    5 pages
    English language
  • Standard
    5 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method is useful in determining phenol in the range from 5 to 50 mg/kg in commercially available cumene or AMS.  
4.2 Phenol will inhibit certain reactions involving cumene or AMS.
SCOPE
1.1 This test method covers the determination of phenol in refined cumene (isopropylbenzene) or AMS (α–methylstyrene).  
1.2 This test method has been found applicable in the range from 5 to 50 mg/kg of phenol in refined cumene (isopropylbenzene) or AMS (α–methylstyrene). The limit of detection (LOD) is 0.9 mg/kg and the limit of quantitation (LOQ) is 2.9 mg/kg.
Note 1: LOD and LOQ were calculated using intermediate precision for the lowest level in the ILS.  
1.3 The following applies for the purposes of determining the conformance of the test results using this test method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

ABSTRACT
This specification covers styrene monomer. The purity, aldehydes, peroxides, polymer, inhibitor, ethylbenzene, water, and color shall be tested to meet the requirements specified.
SCOPE
1.1 This specification covers styrene monomer.  
1.2 The following applies to all specified limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measure are included in this specification.  
1.4 Consult current OSHA regulations, supplier’s Safety Data Sheets, and local regulations for all materials used in this specification.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

ABSTRACT
This specification covers cumene (isopropylbenzene). Tests shall be performed to determine the requirements of cumene in accordance to the following test methods: purity; alpha-methylstrene, benzene, butylbenzenes, diisopropylbenzenes, ethylbenzene, phenols, n-propylbenzene, sulfur, bromine index, and appearance.
SCOPE
1.1 This specification covers cumene (isopropylbenzene).  
1.2 The following applies to all specified limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 Consult current OSHA Regulations and Supplier’s Safety Data Sheets, and local regulations for all materials used in this specification.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

ABSTRACT
This specification covers cumene (isopropylbenzene) manufactured via a zeolite catalyst process. Cumene shall conform to the following requirements: purity weight percent, alpha-methylstrene, benzene, cumene hydroperoxide, diisopropylbenzenes, ethylbenzene, i-butylbenzene, n-butylbenzene, s- butylbenzene, t- butylbenzene, phenols, n-propylbenzene, sulfur, toluene, total butylbenzenes, total cymenes, total non-aromatics, total GC unknowns, bromine index, appearance, and color.
SCOPE
1.1 This specification covers cumene (isopropylbenzene) manufactured using a zeolite catalyst process.  
1.2 The following applies to all specified limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 Consult current OSHA Regulations and Supplier’s Safety Data Sheets, and local regulations for all materials used in this specification.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method is useful in determining phenol in the range from 5 to 50 mg/kg in commercially available cumene or AMS.  
4.2 Phenol will inhibit certain reactions involving cumene or AMS.
SCOPE
1.1 This test method covers the determination of phenol in refined cumene (isopropylbenzene) or AMS (α–methylstyrene).  
1.2 This test method has been found applicable in the range from 5 to 50 mg/kg of phenol in refined cumene (isopropylbenzene) or AMS (α–methylstyrene). The limit of detection (LOD) is 0.9 mg/kg and the limit of quantitation (LOQ) is 2.9 mg/kg.
Note 1: LOD and LOQ were calculated using intermediate precision for the lowest level in the ILS.  
1.3 The following applies for the purposes of determining the conformance of the test results using this test method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

ABSTRACT
This specification covers ethylbenzene. Different tests shall be conducted in order to determine the following properties of ethylbenzene: purity, benzene content, toluene content, xylene content, cumene content, diethylbenzene content, chloride content, sulfur content, and color.
SCOPE
1.1 This specification covers ethylbenzene.  
1.2 The following applies to all specified limits in this specification for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measure are included in this specification.  
1.4 Consult current OSHA regulations, supplier’s Safety Data Sheet for all materials, and local regulations used in this specification.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method is suitable for determining the quantity of aldehydes, both for quality control and quality assurance of the product.
SCOPE
1.1 This test method covers the wet chemical determination of aldehydes in styrene monomer. Aldehydes are calculated and reported as benzaldehyde. The range of concentration for this test method is 0.001 % to 0.030 %.  
1.2 In determining conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method can be used for determining polymer concentrations in AMS monomer.  
4.2 This test method will not detect dimers and trimers.  
4.3 This test method can be used for plant control and for specification analysis.
SCOPE
1.1 This test method covers the determination of the polymer content of AMS (α-Methystyrene). Dimers and trimers are not measured by these test methods.  
1.2 This test method has been found applicable to determining the polymer content of AMS in concentrations up to 15 mg/kg with an LOQ of 0.6 mg/kg and an LOD of 0.2 mg/kg. Samples containing more than 15 mg/kg of polymer must be suitably diluted before measurement.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method is suitable for determining the quantity of TBC inhibitor, both for the protection against polymerization while in transit and storage, and for internal quality control.
SCOPE
1.1 This test method is applicable to the determination of residual 4-tertiary-butylcatechol (TBC) in styrene monomer or AMS in the 1 to 100 mg/kg range. Any other compound producing color at 490 nm when contacted with aqueous sodium hydroxide solution will interfere. It may be compensated for by including it in the preparation of the standard solutions, if its identity and concentration in the sample are known.  
1.2 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29. The limit of detection is 0.2 mg/kg while the limit of quantitation is 0.8 mg/kg based on the ILS data in Table 1.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific statements on hazards, see Section 8.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 Evaporation residue is an empirical measure of nonvolatile impurities in naphthalene. This test method is suitable for setting specifications and for use as an internal quality control tool.
SCOPE
1.1 This test method covers the determination of the evaporation residue of naphthalene.  
1.2 This test method has been found applicable to determining residue in the range of 0.3 and 1.5 wt %.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7, 8.1, 9.2, and 9.3.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
This test method is suitable for determining the quantity of aldehydes, both for quality control and quality assurance of the product.
SCOPE
1.1 This test method covers the wet chemical determination of aldehydes in styrene monomer. Aldehydes are calculated and reported as benzaldehyde. The range of concentration for this test method is 0.001 % to 0.030 %.
1.2 In determining conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E 29.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.
WITHDRAWN RATIONALE
This test method covers the wet chemical determination of aldehydes in styrene monomer. Aldehydes are calculated and reported as benzaldehyde. The range of concentration for this test method is 0.001 % to 0.030 %.
Formerly under the jurisdiction of Committee D16 on Aromatic, Industrial, Specialty and Related Chemicals, this test method was withdrawn in January 2018 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

  • Standard
    2 pages
    English language
  • Standard
    2 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method is suitable for determining the quantity of peroxides in styrene monomer both for quality control and quality assurance of the product.
SCOPE
1.1 This test method covers the determination of the peroxide content of styrene monomer reported as hydrogen peroxide.  
1.2 This test method has been found applicable to the determination of peroxides in styrene monomer in the range of 1 to 60 mg/kg.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method is suitable for setting specifications on the materials referenced in 1.2 and for use as an internal quality control tool where isopropylbenzene is produced or is used in a manufacturing process. It may also be used in development or research work involving isopropylbenzene.  
5.2 This test method is useful in determining the purity of isopropylbenzene with normal impurities present. If extremely high boiling or unusual impurities are present in the isopropylbenzene, this test method would not necessarily detect them and the purity calculation would be erroneous.  
5.3 Cumene hydroperoxide, if present, will yield thermal decomposition products, primarily AP and DMPC as stated in 4.1, that will elute in the chromatogram thereby giving incorrect results unless they are excluded as indicated in 4.1. It is also possible to get erroneous results for trace alpha-methylstyrene present in isopropylbenzene if the inlet has become unduly contaminated with non-volatile foreign substances.  
5.4 The nonaromatic hydrocarbons commonly present from the isopropylbenzene manufacturing process, particularly a non-zeolitic one, will interfere with the determination of xylenes (if present).
SCOPE
1.1 This test method covers the determination of the purity of isopropylbenzene (cumene) by gas chromatography. Calibration of the gas chromatography system is done by the external standard calibration technique.  
1.2 This test method has been found applicable to the measurement of impurities such as nonaromatic hydrocarbons, benzene, toluene, ethylbenzene, phenol, cymenes, t-butylbenzene, n-butylbenzene, n-propylbenzene, alpha-methylstyrene, sec-butylbenzene, and diisopropylbenzenes, which are impurities that can be found in isopropylbenzene. The latter impurities can be analyzed over a range of 1 mg/kg to 500 mg/kg by this method (see Table 1). The limit of quantitation averages 3.8 mg/kg while the limit of detection for these impurities averages 1.1 mg/kg.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    5 pages
    English language
  • Standard
    5 pages
    English language

ABSTRACT
This specification establishes the requirements for AMS (alpha-Methylstyrene). Sampled specimens shall conform to the following physical and chemical properties: minimum AMS content; maximum phenol content; maximum polymer content; inhibitor content; appearance; and color (Pt-Co units).
SCOPE
1.1 This specification covers AMS (α-Methylstyrene).  
1.2 The following applies to all limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 Consult current OSHA regulations, suppliers’ Safety Data Sheets, and local regulations for all materials used in this specification.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method is suitable for setting specifications on the materials referenced in 1.2 and for use as an internal quality control tool where AMS is produced or is used in a manufacturing process. It may also be used in development or research work involving AMS.  
5.2 This test method is useful in determining the purity of AMS with normal impurities present. If extremely high boiling or unusual impurities are present in the AMS, this test method would not necessarily detect them and the purity calculation would be erroneous.
SCOPE
1.1 This test method covers the determination of the purity of AMS (α-methylstyrene) by gas chromatography. Calibration of the gas chromatography system is done by the external standard calibration technique.  
1.2 This test method has been found applicable to the measurement of impurities such as cumene, 3-methyl-2-cyclopentene-1-one, n-propylbenzene, tert-butylbenzene, sec-butylbenzene, cis-2-phenyl-2-butene, acetophenone, 1-phenyl-1-butene, 2-phenyl-2-propanol, trans-2-phenyl-2-butene, m-cymene, p-cymene, and phenol, which are common to the manufacturing process of AMS. The method has also been found applicable for the determination of para-tertiary-butylcatechol typically added as a stabilizer to AMS. The impurities in AMS can be analyzed over a range of 5 to 800 mg/kg by this method. (See Table 1.) The limit of quantitation for these these impurities averages 4 mg/kg, while the limit of detection averages 1.2 mg/kg. (See Table 1.)  
TABLE 1 Summary of Precision Data (mg/kg)    
Compound  
Repeatability (r)  
Reproducibility (R)  
Range Studied  
Acetone  
1.61 + 0.035*Acetone  
0.47 + 1.10*Acetone  
0.5 – 26  
Cumene  
−0.46 + 0.031*Cumene  
7.88 + 0.19*Cumene  
45 – 290  
nPropylbenzene (NPB)  
2.11 + 0.03*NPB  
−7.81 + 0.37*NPB  
55 – 195  
Phenol  
1.84  
3.65 + 0.58*Phenol  
1 – 40  
tertButylbenzene (TBB)  
−1.22 + 0.035*TBB  
3.63 + 0.087*TBB  
150 – 650  
secButylbenzene (SBB)  
4.23 + 0.019*SBB  
21.60 + 0.25*SBB  
200 – 765  
mCymene  
0.31 + 0.035*mCymene  
2.34 + 0.35*mCymene  
2 – 50  
oCymene  
1.63  
8.00  
29 – 31  
pCymene  
5.12  
15.79  
10 – 18  
cis-2-Phenyl-2-Butene (CPB)  
0.17 + 0.030*CPB  
5.39 + 0.11*CPB  
50 – 225  
trans-2-Phenyl-2-Butene (TPB)  
1.57  
0.54 + 0.20*TPB  
19 – 70  
1-Phenyl-1-Butene (PB)  
4.00 + 0.018*PB  
0.17 + 0.19*PB  
0.2 – 735  
Acetophenone (AP)  
–1.09 + 0.15*AP  
1.17 + 0.63*AP  
15 – 115  
para-tert-Butylcatechol (PTBC)  
2.21  
17.82  
10 – 19  
2-Methylbenzofuran (MBF)  
0.33 + 0.76*MBF  
0.75 + 0.60*MBF  
1 – 2  
2-Phenylpropion aldehyde (PPA)  
0.59 + 0.11*PPA  
0.29 + 0.23*PPA  
1.5 – 15  
α-Methylstyrene Oxide (AMSO)  
4.61  
6.51 + 0.23*AMSO  
13 – 32  
DimethylBenzyl Alcohol (DMBA)  
0.38  
0.55 + 2.03*DMBA  
0.1 – 1  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    5 pages
    English language
  • Standard
    5 pages
    English language

ABSTRACT
This specification covers cumene (isopropylbenzene) manufactured via a zeolite catalyst process. Cumene shall conform to the following requirements: purity weight percent, alpha-methylstrene, benzene, cumene hydroperoxide, diisopropylbenzenes, ethylbenzene, i-butylbenzene, n-butylbenzene, s- butylbenzene, t- butylbenzene, phenols, n-propylbenzene, sulfur, toluene, total butylbenzenes, total cymenes, total non-aromatics, total GC unknowns, bromine index, appearance, and color.
SCOPE
1.1 This specification covers cumene (isopropylbenzene) manufactured using a zeolite catalyst process.  
1.2 The following applies to all specified limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 Consult current OSHA Regulations and Supplier’s Safety Data Sheets, and local regulations for all materials used in this specification.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

ABSTRACT
This specification covers ethylbenzene. Different tests shall be conducted in order to determine the following properties of ethylbenzene: purity, benzene content, toluene content, xylene content, cumene content, diethylbenzene content, chloride content, sulfur content, and color.
SCOPE
1.1 This specification covers ethylbenzene.  
1.2 Consult current OSHA regulations, supplier’s Safety Data Sheet for all materials, and local regulations used in this specification.  
1.3 The following applies to all specified limits in this specification for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

ABSTRACT
This specification covers cumene (isopropylbenzene). Tests shall be performed to determine the requirements of cumene in accordance to the following test methods: purity; alpha-methylstrene, benzene, butylbenzenes, diisopropylbenzenes, ethylbenzene, phenols, n-propylbenzene, sulfur, bromine index, and appearance.
SCOPE
1.1 This specification covers cumene (isopropylbenzene).  
1.2 The following applies to all specified limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 Consult current OSHA Regulations and Supplier’s Safety Data Sheets, and local regulations for all materials used in this specification.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

ABSTRACT
This specification establishes the requirements for AMS (alpha-Methylstyrene). Sampled specimens shall conform to the following physical and chemical properties: minimum AMS content; maximum phenol content; maximum polymer content; inhibitor content; appearance; and color (Pt-Co units).
SCOPE
1.1 This specification covers AMS (α-Methylstyrene).  
1.2 The following applies to all limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 Consult current OSHA regulations, suppliers’ Safety Data Sheets, and local regulations for all materials used in this specification.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method is designed to obtain styrene purity on the basis of impurities normally present in styrene and may be used for final product inspections and process control.  
5.2 This test method will detect the impurities shown in Table 1, non-aromatic hydrocarbons containing ten carbons or less, and others where specific impurity standards are available. Absolute purity cannot be determined if unknown impurities are present.
SCOPE
1.1 This test method covers the determination of the impurities typically found in styrene and uses those values to determine the purity of styrene by difference by gas chromatography. Typical impurities in commercial styrene are found in Table 1.    
1.2 This test method is applicable to impurity concentrations in the range of 0.001 to 1.00 % and for styrene purities of 99 % or higher when using the internal standard procedure.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Section 9.

  • Standard
    5 pages
    English language
  • Standard
    5 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method is suitable for determining the quantity of aldehydes, both for quality control and quality assurance of the product.
SCOPE
1.1 This test method covers the wet chemical determination of total aldehydes in styrene monomer. Total aldehydes are calculated and reported as benzaldehyde. The Range of Concentration for this test method is 0.004 weight % to 0.013 weight %.  
1.2 Limit of Detection (LOD) and Limit of Quantification (LOQ) is 0.0006 and 0.0020 weight %, respectively  
1.3 In determining conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard with the exception: weight % should be used rather than mass %.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method can be used for determining polymer concentrations in styrene monomer.  
5.2 This test method will not detect dimers and trimers.  
5.3 This test method can be used for plant control and for specification analysis.
SCOPE
1.1 These test methods cover the determination of the polymer content of styrene monomer. It should be noted, however, that dimers and trimers are not measured by these test methods.  
1.2 Test Method A, which is based on the use of a spectrophotometer or photometer, is intended for the quantitative determination of the polymer content of styrene monomer in concentrations up to 15 mg/kg. Samples containing more than 15 mg/kg of polymer must be suitably diluted before measurement.  
1.3 Test Method B is a rapid visual procedure that is intended for the approximate evaluation of polymer to a maximum concentration of 1.0 mass %. Samples having a polymer content of 1.0 mass % or greater should be suitably diluted prior to measurement.  
1.4 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

ABSTRACT
This specification covers cumene (isopropylbenzene). Tests shall be performed to determine the requirements of cumene in accordance to the following test methods: purity; alpha-methylstrene, benzene, butylbenzenes, diisopropylbenzenes, ethylbenzene, phenols, n-propylbenzene, sulfur, bromine index, and appearance.
SCOPE
1.1 This specification covers cumene (isopropylbenzene).  
1.2 The following applies to all specified limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 Consult current OSHA Regulations and Supplier’s Safety Data Sheets, and local regulations for all materials used in this specification.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

ABSTRACT
This specification covers cumene (isopropylbenzene) manufactured via a zeolite catalyst process. Cumene shall conform to the following requirements: purity weight percent, alpha-methylstrene, benzene, cumene hydroperoxide, diisopropylbenzenes, ethylbenzene, i-butylbenzene, n-butylbenzene, s- butylbenzene, t- butylbenzene, phenols, n-propylbenzene, sulfur, toluene, total butylbenzenes, total cymenes, total non-aromatics, total GC unknowns, bromine index, appearance, and color.
SCOPE
1.1 This specification covers cumene (isopropylbenzene) manufactured using a zeolite catalyst process.  
1.2 The following applies to all specified limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 Consult current OSHA Regulations and Supplier’s Safety Data Sheets, and local regulations for all materials used in this specification.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method is useful in determining phenol in the range from 5 to 50 mg/kg in commercially available cumene or AMS.  
4.2 Phenol will inhibit certain reactions involving cumene or AMS.
SCOPE
1.1 This test method covers the determination of phenol in refined cumene (isopropylbenzene) or AMS (α–methylstyrene).  
1.2 This test method has been found applicable in the range from 5 to 50 mg/kg of phenol in refined cumene (isopropylbenzene) or AMS (α–methylstyrene).  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method is designed to obtain styrene purity on the basis of impurities normally present in styrene and may be used for final product inspections and process control.  
5.2 This test method will detect the impurities shown in Table 1, non-aromatic hydrocarbons containing ten carbons or less, and others where specific impurity standards are available. Absolute purity cannot be determined if unknown impurities are present.
SCOPE
1.1 This test method covers the determination of the impurities typically found in styrene and uses those values to determine the purity of styrene by difference by gas chromatography. Typical impurities in commercial styrene are found in Table 1.    
1.2 This test method is applicable to impurity concentrations in the range of 0.001 to 1.00 % and for styrene purities of 99 % or higher when using the internal standard procedure.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Section 9.

  • Standard
    5 pages
    English language
  • Standard
    5 pages
    English language

ABSTRACT
This specification covers ethylbenzene. Different tests shall be conducted in order to determine the following properties of ethylbenzene: purity, benzene content, toluene content, xylene content, cumene content, diethylbenzene content, chloride content, sulfur content, and color.
SCOPE
1.1 This specification covers ethylbenzene.  
1.2 Consult current OSHA regulations, supplier’s Safety Data Sheet for all materials, and local regulations used in this specification.  
1.3 The following applies to all specified limits in this specification for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.

  • Technical specification
    2 pages
    English language
  • Technical specification
    2 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method can be used for determining polymer concentrations in styrene monomer.  
5.2 This test method will not detect dimers and trimers.  
5.3 This test method can be used for plant control and for specification analysis.
SCOPE
1.1 These test methods cover the determination of the polymer content of styrene monomer. It should be noted, however, that dimers and trimers are not measured by these test methods.  
1.2 Test Method A, which is based on the use of a spectrophotometer or photometer, is intended for the quantitative determination of the polymer content of styrene monomer in concentrations up to 15 mg/kg. Samples containing more than 15 mg/kg of polymer must be suitably diluted before measurement.  
1.3 Test Method B is a rapid visual procedure that is intended for the approximate evaluation of polymer to a maximum concentration of 1.0 mass %. Samples having a polymer content of 1.0 mass % or greater should be suitably diluted prior to measurement.  
1.4 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method can be used for determining polymer concentrations in AMS monomer.  
4.2 This test method will not detect dimers and trimers.  
4.3 This test method can be used for plant control and for specification analysis.
SCOPE
1.1 This test method covers the determination of the polymer content of AMS (α-Methystyrene). Dimers and trimers are not measured by these test methods.  
1.2 This test method has been found applicable to determining the polymer content of AMS in concentrations up to 15 mg/kg. Samples containing more than 15 mg/kg of polymer must be suitably diluted before measurement.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.

  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
5.1 Evaporation residue is an empirical measure of nonvolatile impurities in naphthalene. This test method is suitable for setting specifications and for use as an internal quality control tool.
SCOPE
1.1 This test method covers the determination of the evaporation residue of naphthalene.  
1.2 This test method has been found applicable to determining residue in the range of 0.3 and 1.5 wt %.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7 and 8.1.

  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method is designed to obtain styrene purity on the basis of impurities normally present in styrene and may be used for final product inspections and process control.  
5.2 This test method will detect the impurities shown in Table 1, non-aromatic hydrocarbons containing ten carbons or less, and others where specific impurity standards are available. Absolute purity cannot be determined if unknown impurities are present.
SCOPE
1.1 This test method covers the determination of the impurities typically found in styrene and uses those values to determine the purity of styrene by difference by gas chromatography. Typical impurities in commercial styrene are found in Table 1. TABLE 1 Impurities Known or Suggested to be Present in Commercial Styrene    
Ethylbenzene    
o-xylene  
m-xylene  
p-xylene  
Isopropylbenzene  
n-propylbenzene  
m-ethyltoluene  
p-ethyltoluene  
α-methylstyrene    
m-vinyltoluene  
p-vinyltoluene  
Phenylacetylene
1.2 This test method is applicable to impurity concentrations in the range of 0.001 to 1.00 % and for styrene purities of 99 % or higher when using the internal standard procedure.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Section 9.

  • Standard
    5 pages
    English language
  • Standard
    5 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method is suitable for determining the quantity of peroxides in styrene monomer both for quality control and quality assurance of the product.
SCOPE
1.1 This test method covers the determination of the peroxide content of styrene monomer.  
1.2 This test method has been found applicable to the determination of peroxides in styrene monomer in the range of 1 to 60 mg/kg.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method is suitable for setting specifications on the materials referenced in 1.2 and for use as an internal quality control tool where isopropylbenzene is produced or is used in a manufacturing process. It may also be used in development or research work involving isopropylbenzene.  
4.2 This test method is useful in determining the purity of isopropylbenzene with normal impurities present including diisopropylbenzenes. If extremely high boiling or unusual impurities are present in the isopropylbenzene, this test method would not necessarily detect them and the purity calculation would be erroneous.  
4.3 Cumene hydroperoxide, if present, will yield decomposition products that will elute in the chromatogram thereby giving incorrect results.  
4.4 The nonaromatic hydrocarbons commonly present from the isopropylbenzene manufacturing process will interfere with the determination of benzene when Column A in Table 1 is used.
4.5 The internal standard must be sufficiently resolved from any impurity and the isopropylbenzene peak.
SCOPE
1.1 This test method covers the determination of the purity of isopropylbenzene (cumene) by gas chromatography.  
1.2 This test method has been found applicable to the measurement of impurities such as nonaromatic hydrocarbons, benzene, ethylbenzene, t-butylbenzene, n-propylbenzene, alpha-methylstyrene, sec-butylbenzene, and diisopropylbenzene, which are common to the manufacturing process of isopropylbenzene. Limit of detection for these impurities is 10 mg/kg (see 5.1). This method has been found applicable for concentrations of various components up to 571 ppm.  
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.

  • Standard
    6 pages
    English language
  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method is suitable for setting specifications on the materials referenced in 1.2 and for use as an internal quality control tool where isopropylbenzene is produced or is used in a manufacturing process. It may also be used in development or research work involving isopropylbenzene.  
5.2 This test method is useful in determining the purity of isopropylbenzene with normal impurities present. If extremely high boiling or unusual impurities are present in the isopropylbenzene, this test method would not necessarily detect them and the purity calculation would be erroneous.  
5.3 Cumene hydroperoxide, if present, will yield thermal decomposition products, primarily AP and DMPC as stated in 4.1, that will elute in the chromatogram thereby giving incorrect results unless they are excluded as indicated in 4.1. It is also possible to get erroneous results for trace alpha-methylstyrene present in isopropylbenzene if the inlet has become unduly contaminated with non-volatile foreign substances.  
5.4 The nonaromatic hydrocarbons commonly present from the isopropylbenzene manufacturing process, particularly a non-zeolitic one, will interfere with the determination of xylenes (if present).
SCOPE
1.1 This test method covers the determination of the purity of isopropylbenzene (cumene) by gas chromatography. Calibration of the gas chromatography system is done by the external standard calibration technique.  
1.2 This test method has been found applicable to the measurement of impurities such as nonaromatic hydrocarbons, benzene, toluene, ethylbenzene, phenol, cymenes, t-butylbenzene, n-butylbenzene, n-propylbenzene, alpha-methylstyrene, sec-butylbenzene, and diisopropylbenzenes, which are impurities that can be found in isopropylbenzene. The latter impurities can be analyzed over a range of 1 mg/kg to 500 mg/kg by this method (see Table 1). The limit of detection for these impurities is summarized in Table 1 as well.
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.

  • Standard
    5 pages
    English language
  • Standard
    5 pages
    English language

Frequently Asked Questions

D16.07 is a Technical Committee within ASTM International. It is named "Styrene, Ethylbenzene and C9 and C10 Aromatic Hydrocarbons". This committee has published 112 standards.

D16.07 develops ASTM standards in the area of Information technology. Currently, there are 112 published standards from this technical committee.

ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.

A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.

Loading...