E12.11 - Visual Methods
Visual Methods
General Information
SIGNIFICANCE AND USE
4.1 Metameric color matches result from the use of different colorants (pigments, dyes, and the like) in achieving the same color match. Usually, the purchaser requires that the color match be nonmetameric; this practice permits this requirement to be quickly tested in both field and laboratory. Where nonmetameric matches are not possible or practicable, for cost or other reasons, some limitation of metamerism may be required. The procedures for estimating the magnitude of metamerism described in this practice provide methods for assessing the effectiveness of such limitation.
SCOPE
1.1 This practice describes visual methods for detecting metamerism and for estimating the magnitude of a metameric color difference.
1.2 The practice is limited to the consideration of illuminant metamerism and observer metamerism. This practice does not cover gonioapparent samples.
1.3 This practice does not provide for the computation of indices of metamerism based upon instrumental measurement of spectral characteristics.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The term appearance (see 3.2.1) implies the essential presence of human visual observations. The results of visual observation involve not only the step of observing, accomplished by the eye, but also the inseparable step of interpretation in the brain. Instrumental test methods currently cannot duplicate this second step, and therefore can now only approximate, but not fully measure, appearance. Such instrumental measures of appearance properties are useful only to the extent that they can be correlated to the results of visual observations by observers of the appearance phenomena being evaluated.
5.2 Almost invariably, too little attention has been paid to ensuring that the essential visual observations have been properly obtained to provide the basis for correlating visual and instrumental test results.
5.3 This guide provides the means for assessing observers, by outlining the requirements and tests for their selection, evaluation, and training. This guide should be useful to all experimenters designing or using visual test methods to provide either direct results in terms of the observation of appearance properties, or the experiments correlating such results with instrumental measures approximating the same appearance properties. The user is cautioned to avoid the substitution of validated vision tests with replicas of any kind, either printed, photographed or digitally displayed.
SCOPE
1.1 This guide describes criteria and tests for selecting, evaluating, and training human visual-sensory observers for tasks involving the perception and scaling of properties and phenomena relating to appearance.
1.2 Examples of tests requiring the use of trained observers include but are not limited to those described in the following ASTM standards: on color, Practice D1535 and Practice E1360; on color difference, Practice D1729 and Test Method D2616; on gloss, Test Method D4449; on metamerism, Practice D4086; and on setting tolerances, Practice D3134.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide4 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Although color measuring instruments are widely used, color matches are usually checked visually. The standardization of visual examination has greatly improved the uniformity of products and the accuracy of color matches.
4.2 The use of this practice is essential for critical color matching but is also recommended for any color appraisal, such as the choice or approval of a color. This practice is widely used in industry to choose colors, exhibit colors reproducibility, inspect incoming materials, monitor color producing processes, and inspect finished goods. Visual appraisal is particularly important when the product inspected is not of the same material as the color standard to which it is compared.
4.2.1 Observers—This practice is based on the fundamental assumption that the observer has superior color vision and is trained and experienced in observing and classifying color differences. The significance of the results depends on that being so. The selection, evaluation, and training of observers are treated in Guide E1499.
4.2.2 Illumination—Simulated average daylight, D65, is recommended by the International Commission on Illumination (CIE). D50 is recommended for applications involving color photography or color printing as specified in ISO 3364-2009.
SCOPE
1.1 This practice specifies the equipment and procedures for visual appraisal of the colors and color differences of opaque materials that are diffusely illuminated. These specifications are of critical importance in color matching. This practice requires judgments by observers with a minimum of normal color vision and preferably superior as rated with the FM-100 Hue Test as specified in Guide E1499.
1.2 Critical visual appraisal of colors and color differences of materials such as metallic and pearlescent paints requires illumination that is nearly a geometric simulation of direct sunlight, because such directional illumination permits observation of the sparkle (glitter) and goniochromatism that characterize such materials. Such viewing conditions are beyond the scope of this practice.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
- Standard4 pagesEnglish language
ABSTRACT
This guide is intended to help the user decide on the type of viewing conditions, visual scaling methods, and analysis that should be used to obtain reliable visual experimental data. It is also intended to illustrate the techniques that lead to visual observations that can be correlated with objective instrumental measurements of appearance attributes of objects. This guide includes a review of issues regarding the choice and design of viewing environments, an overview of various classes of visual experiments, a review of experimental techniques for threshold, matching, and scaling experiments, a review for data reduction and analysis procedures. The three different threshold and matching techniques namely, the methods of adjustment, limits, and constant stimuli, are explained. Perceptual scaling techniques reviewed include ranking, graphical rating, category scaling, paired comparisons, triadic combinations, partitioning, and magnitude estimation or production. Brief descriptions and examples, along with references to more detailed literature, are given on the appropriate types of data analysis for each experimental technique.
SCOPE
1.1 This guide is intended to help the user decide on the type of viewing conditions, visual scaling methods, and analysis that should be used to obtain reliable visual data.
1.2 This guide is intended to illustrate the techniques that lead to visual observations that can be correlated with objective instrumental measurements of appearance attributes of objects. The establishment of both parts of such correlations is an objective of Committee E12.
1.3 Among ASTM standards making use of visual observations are Practices D1535, D1729, D3134, D4086, and E1478; Test Methods D2616, D3928, and D4449; and Guide E1499.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Gloss3 is associated with the capacity of a surface to reflect more light in some directions than in others. The directions associated with mirror (or specular) reflection normally have the highest reflectances. Gloss is best seen and analyzed when the surfaces studied are illuminated by a light source that provides strong contrasting patterns of light and dark. Such a light source is described in this test method.
5.2 The simplest concept of gloss is that it corresponds to the mirror-like reflectances of surfaces. However, the distributions and intensities of this surface-reflected light are (for real materials) highly variable and affected by a variety of factors: surface smoothness and contour, refractive index, absorptance, angle of incidence, and (to a generally small extent) wavelength. From the great variety of surface-reflection patterns met in materials of commerce, it has been possible to identify seven surface-reflection criteria or “types of gloss” regularly used by skilled technologists for intercomparing and rating their products for gloss. Six of the seven criteria, or “types of gloss,” are identified in the section on definitions. The seventh, luster or contrast gloss, is seldom of concern to the coatings industry.
SCOPE
1.1 This test method covers the visual evaluation of gloss differences of coating surfaces, using special types of lamps for illumination. It identifies six aspects or types of gloss that one may look for when using the lamp to assess gloss differences between surfaces. It describes the conditions for using the lamps to best identify small differences in each of the six types of gloss. Four levels of visual gloss differences are distinguished.
1.2 While this technique is useful for both weathered and unweathered specimens, it has not been applied to metallics.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Color specifications are centered around exact positions in color space. Correspondingly, gloss specifications are centered around an exact position on the gloss scale. Because it is difficult to achieve these exact positions repeatedly, it is necessary to specify tolerances that are acceptable to both the buyer and the seller. This practice details the procedure for accomplishing this goal.
SCOPE
1.1 This practice describes a procedure for establishing tolerances and evaluating the color and gloss of specimens with respect to specified standards. This practice is appropriate for nonfluorescent opaque specimens.
1.2 This practice does not indicate the extent of tolerances, but gives guidance on how they can be set. For product specification, the tolerances between specimens and the specified standard should be agreed upon between the purchaser and the seller.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard7 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The total perceived color difference between two non-self-luminous specimens is compared as an equivalent lightness difference between two neutral gray specimens on a gray scale. A fundamental assumption is made that the total color difference can be so evaluated in terms of an equivalent lightness difference. Only the total color differences, that is, a summation of the differences in hue, lightness, and chroma between two specimens is evaluated; this test method is not applicable to the separate precise evaluation of the hue, lightness, and chroma components of color difference.
5.2 The total color difference determined by this test method depends on the degree of uniformity of the specimens and on the sharpness of the dividing line between them. The color difference between specimens having rough or mottled surfaces appears smaller than it would if the specimens had smooth and uniform surfaces. Thus the equivalent CIELAB lightness difference determined for non-uniform specimens will be smaller than for uniform specimens. Likewise, specimens whose dividing line is not sharp will appear to have smaller color differences than those with sharp dividing lines, and for this reason, the equivalent visually observed CIELAB lightness differences will be smaller than the color differences obtained from instrumental measurements.
5.2.1 A physically sharp border between colors differing slightly in the yellow-blue direction in color space appears diffuse. The perceived color difference is noticeably increased by a hairline black separation. This technique imposes a more rigorous test of such small differences.
5.3 In the CIELAB system, a unit of color difference is intended to represent the same visual difference in each of the three attributes; lightness, hue and chroma or alternatively lightness, redness-greenness, yellowness-blueness. It is valid to express color differences that are not simply lightness differences by comparison to a lightness-difference sca...
SCOPE
1.1 This test method describes a painted gray scale and the procedure to be used in the visual evaluation of color differences of non-self luminous materials by comparison to this scale.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Metameric color matches result from the use of different colorants (pigments, dyes, and the like) in achieving the same color match. Usually, the purchaser requires that the color match be nonmetameric; this practice permits this requirement to be quickly tested in both field and laboratory. Where nonmetameric matches are not possible or practicable, for cost or other reasons, some limitation of metamerism may be required. The procedures for estimating the magnitude of metamerism described in this practice provide methods for assessing the effectiveness of such limitation.
SCOPE
1.1 This practice describes visual methods for detecting metamerism and for estimating the magnitude of a metameric color difference.
1.2 The practice is limited to the consideration of illuminant metamerism and observer metamerism. This practice does not cover gonioapparent samples.
1.3 This practice does not provide for the computation of indices of metamerism based upon instrumental measurement of spectral characteristics.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The term appearance (see 3.2.1) implies the essential presence of human visual observations. The results of visual observation involve not only the step of observing, accomplished by the eye, but also the inseparable step of interpretation in the brain. Instrumental test methods currently cannot duplicate this second step, and therefore can now only approximate, but not fully measure, appearance. Such instrumental measures of appearance properties are useful only to the extent that they can be correlated to the results of visual observations by observers of the appearance phenomena being evaluated.
5.2 Almost invariably, too little attention has been paid to ensuring that the essential visual observations have been properly obtained to provide the basis for correlating visual and instrumental test results.
5.3 This guide provides the means for assessing observers, by outlining the requirements and tests for their selection, evaluation, and training. This guide should be useful to all experimenters designing or using visual test methods to provide either direct results in terms of the observation of appearance properties, or the experiments correlating such results with instrumental measures approximating the same appearance properties. The user is cautioned to avoid the substitution of validated vision tests with replicas of any kind, either printed, photographed or digitally displayed.
SCOPE
1.1 This guide describes criteria and tests for selecting, evaluating, and training human visual-sensory observers for tasks involving the perception and scaling of properties and phenomena relating to appearance.
1.2 Examples of tests requiring the use of trained observers include but are not limited to those described in the following ASTM standards: on color, Practice D1535 and Practice E1360; on color difference, Practice D1729 and Test Method D2616; on gloss, Test Method D4449; on metamerism, Practice D4086; and on setting tolerances, Practice D3134.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide4 pagesEnglish language
- Guide4 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Although color measuring instruments are widely used, color matches are usually checked visually. The standardization of visual examination has greatly improved the uniformity of products and the accuracy of color matches.
4.2 The use of this practice is essential for critical color matching but is also recommended for any color appraisal, such as the choice or approval of a color. This practice is widely used in industry to choose colors, exhibit colors reproducibility, inspect incoming materials, monitor color producing processes, and inspect finished goods. Visual appraisal is particularly important when the product inspected is not of the same material as the color standard to which it is compared.
4.2.1 Observers—This practice is based on the fundamental assumption that the observer has superior color vision and is trained and experienced in observing and classifying color differences. The significance of the results depends on that being so. The selection, evaluation, and training of observers are treated in Guide E1499.
4.2.2 Illumination—Simulated average daylight, D65, is recommended by the International Commission on Illumination (CIE). D50 is recommended for applications involving color photography or color printing as specified in ISO 3364-2009.
SCOPE
1.1 This practice specifies the equipment and procedures for visual appraisal of the colors and color differences of opaque materials that are diffusely illuminated. These specifications are of critical importance in color matching. This practice requires judgments by observers with a minimum of normal color vision and preferably superior as rated with the FM-100 Hue Test as specified in Guide E1499.
1.2 Critical visual appraisal of colors and color differences of materials such as metallic and pearlescent paints requires illumination that is nearly a geometric simulation of direct sunlight, because such directional illumination permits observation of the sparkle (glitter) and goniochromatism that characterize such materials. Such viewing conditions are beyond the scope of this practice.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard4 pagesEnglish language
- Standard4 pagesEnglish language
ABSTRACT
This guide is intended to help the user decide on the type of viewing conditions, visual scaling methods, and analysis that should be used to obtain reliable visual experimental data. It is also intended to illustrate the techniques that lead to visual observations that can be correlated with objective instrumental measurements of appearance attributes of objects. This guide includes a review of issues regarding the choice and design of viewing environments, an overview of various classes of visual experiments, a review of experimental techniques for threshold, matching, and scaling experiments, a review for data reduction and analysis procedures. The three different threshold and matching techniques namely, the methods of adjustment, limits, and constant stimuli, are explained. Perceptual scaling techniques reviewed include ranking, graphical rating, category scaling, paired comparisons, triadic combinations, partitioning, and magnitude estimation or production. Brief descriptions and examples, along with references to more detailed literature, are given on the appropriate types of data analysis for each experimental technique.
SCOPE
1.1 This guide is intended to help the user decide on the type of viewing conditions, visual scaling methods, and analysis that should be used to obtain reliable visual data.
1.2 This guide is intended to illustrate the techniques that lead to visual observations that can be correlated with objective instrumental measurements of appearance attributes of objects. The establishment of both parts of such correlations is an objective of Committee E12.
1.3 Among ASTM standards making use of visual observations are Practices D1535, D1729, D3134, D4086, and E1478; Test Methods D2616, D3928, and D4449; and Guide E1499.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide8 pagesEnglish language
- Guide8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Gloss3 is associated with the capacity of a surface to reflect more light in some directions than in others. The directions associated with mirror (or specular) reflection normally have the highest reflectances. Gloss is best seen and analyzed when the surfaces studied are illuminated by a light source that provides strong contrasting patterns of light and dark. Such a light source is described in this test method.
5.2 The simplest concept of gloss is that it corresponds to the mirror-like reflectances of surfaces. However, the distributions and intensities of this surface-reflected light are (for real materials) highly variable and affected by a variety of factors: surface smoothness and contour, refractive index, absorptance, angle of incidence, and (to a generally small extent) wavelength. From the great variety of surface-reflection patterns met in materials of commerce, it has been possible to identify seven surface-reflection criteria or “types of gloss” regularly used by skilled technologists for intercomparing and rating their products for gloss. Six of the seven criteria, or “types of gloss,” are identified in the section on definitions. The seventh, luster or contrast gloss, is seldom of concern to the coatings industry.
SCOPE
1.1 This test method covers the visual evaluation of gloss differences of coating surfaces, using special types of lamps for illumination. It identifies six aspects or types of gloss that one may look for when using the lamp to assess gloss differences between surfaces. It describes the conditions for using the lamps to best identify small differences in each of the six types of gloss. Four levels of visual gloss differences are distinguished.
1.2 While this technique is useful for both weathered and unweathered specimens, it has not been applied to metallics.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard8 pagesEnglish language
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Color specifications are centered around exact positions in color space. Correspondingly, gloss specifications are centered around an exact position on the gloss scale. Because it is difficult to achieve these exact positions repeatedly, it is necessary to specify tolerances that are acceptable to both the buyer and the seller. This practice details the procedure for accomplishing this goal.
SCOPE
1.1 This practice describes a procedure for establishing tolerances and evaluating the color and gloss of specimens with respect to specified standards. This practice is appropriate for nonfluorescent opaque specimens.
1.2 This practice does not indicate the extent of tolerances, but gives guidance on how they can be set. For product specification, the tolerances between specimens and the specified standard should be agreed upon between the purchaser and the seller.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard7 pagesEnglish language
- Standard7 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Metameric color matches result from the use of different colorants (pigments, dyes, and the like) in achieving the same color match. Usually, the purchaser requires that the color match be nonmetameric; this practice permits this requirement to be quickly tested in both field and laboratory. Where nonmetameric matches are not possible or practicable, for cost or other reasons, some limitation of metamerism may be required. The procedures for estimating the magnitude of metamerism described in this practice provide methods for assessing the effectiveness of such limitation.
SCOPE
1.1 This practice describes visual methods for detecting metamerism and for estimating the magnitude of a metameric color difference.
1.2 The practice is limited to the consideration of illuminant metamerism and observer metamerism. It is not designed to cover so-called geometric metamerism, in which members of specimen pairs change relative appearance as the angles of illumination and viewing are changed, for example, because they incorporate flake metal or pearlescent colorants.
1.3 This practice does not provide for the computation of indices of metamerism based upon instrumental measurement of spectral characteristics.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard2 pagesEnglish language
SIGNIFICANCE AND USE
The total perceived color difference between two non-self luminous specimens is compared as an equivalent lightness difference between two neutral gray specimens on a gray scale. A fundamental assumption is made that the total color difference can be so evaluated in terms of an equivalent lightness difference. Only the total color differences, that is, a summation of the differences in hue, lightness, and chroma between two specimens is evaluated; this test method is not applicable to the separate precise evaluation of the hue, lightness, and chroma components of color difference.
The total color difference determined by this test method depends on the degree of uniformity of the specimens and on the sharpness of the dividing line between them. The color difference between specimens having rough or mottled surfaces appears smaller than it would if the specimens had smooth and uniform surfaces. Thus the equivalent CIELAB lightness difference determined for non-uniform specimens will be smaller than for uniform specimens. Likewise, specimens whose dividing line is not sharp will appear to have smaller color differences than those with sharp dividing lines, and for this reason, the equivalent visually observed CIELAB lightness differences will be smaller than the color differences obtained from instrumental measurements.
A physically sharp border between colors differing slightly in the yellow-blue direction in color space appears diffuse. The perceived color difference is noticeably increased by a hairline black separation. This technique imposes a more rigorous test of such small differences.
In the CIELAB system, a unit of color difference is intended to represent the same visual difference in each of the three attributes; lightness, hue and chroma or alternatively lightness, redness-greeness, yellowness-blueness. It is valid to express color differences that are not simply lightness differences by comparison to a lightness-difference scale.
Personnel to be ...
SCOPE
1.1 This test method describes a painted gray scale and the procedure to be used in the visual evaluation of color differences of non-self luminous materials by comparison to this scale.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
The total perceived color difference between two non-self luminous specimens is compared as an equivalent lightness difference between two neutral gray specimens on a gray scale. A fundamental assumption is made that the total color difference can be so evaluated in terms of an equivalent lightness difference. Only the total color differences, that is, a summation of the differences in hue, lightness, and chroma between two specimens is evaluated; this test method is not applicable to the separate precise evaluation of the hue, lightness, and chroma components of color difference.
The total color difference determined by this test method depends on the degree of uniformity of the specimens and on the sharpness of the dividing line between them. The color difference between specimens having rough or mottled surfaces appears smaller than it would if the specimens had smooth and uniform surfaces. Thus the equivalent CIELAB lightness difference determined for non-uniform specimens will be smaller than for uniform specimens. Likewise, specimens whose dividing line is not sharp will appear to have smaller color differences than those with sharp dividing lines, and for this reason, the equivalent visually observed CIELAB lightness differences will be smaller than the color differences obtained from instrumental measurements.
5.2.1 A physically sharp border between colors differing slightly in the yellow-blue direction in color space appears diffuse. The perceived color difference is noticeably increased by a hairline black separation. This technique imposes a more rigorous test of such small differences.
In the CIELAB system, a unit of color difference is intended to represent the same visual difference in each of the three attributes; lightness, hue and chroma or alternatively lightness, redness-greeness, yellowness-blueness. It is valid to express color differences that are not simply lightness differences by comparison to a lightness-difference scale.
Personnel ...
SCOPE
1.1 This test method describes a painted gray scale and the procedure to be used in the visual evaluation of color differences of non-self luminous materials by comparison to this scale.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
WITHDRAWN RATIONALE
This test method describes a painted gray scale and the procedure to be used in the visual evaluation of color differences of non-self luminous materials by comparison to this scale.
Formerly under the jurisdiction of Committee E12 on Color and Appearance, this test method was withdrawn in April 2012 in accordance with section 10.5.3.1 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
The term appearance (see 3.2.1) implies the essential presence of human visual observations. The results of visual observation involve not only the step of observing, accomplished by the eye, but also the inseparable step of interpretation in the brain. Instrumental test methods currently cannot duplicate this second step, and therefore can now only approximate, but not fully measure, appearance. Such instrumental measures of appearance properties are useful only to the extent that they can be correlated to the results of visual observations by observers of the appearance phenomena being evaluated.
Almost invariably, too little attention has been paid to ensuring that the essential visual observations have been properly obtained to provide the basis for correlating visual and instrumental test results. (The only recent book devoted to visual measurements (1) has no index entry for observer.)
This guide provides the means for assessing observers, by outlining the requirements and tests for their selection, evaluation, and training. This guide should be useful to all experimenters designing or using visual test methods to provide either direct results in terms of the observation of appearance properties, or the experiments correlating such results with instrumental measures approximating the same appearance properties.
SCOPE
1.1 This guide describes criteria and tests for selecting, evaluating, and training human visual-sensory observers for tasks involving the perception and scaling of properties and phenomena relating to appearance.
1.2 Examples of tests requiring the use of trained observers include but are not limited to those described in the following ASTM standards: on color, Practice D1535 and Practice E1360; on color difference, Practice D1729 and Test Method D2616; on gloss, Test Method D4449; on metamerism, Practice D4086; and on setting tolerances, Practice D3134.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide4 pagesEnglish language
- Guide4 pagesEnglish language
SIGNIFICANCE AND USE
Although color measuring instruments are widely used, color matches are usually checked visually. The standardization of visual examination has greatly improved the uniformity of products and the accuracy of color matches.
The use of this practice is essential for critical color matching but is also recommended for any color appraisal, such as the choice or approval of a color. This practice is widely used in industry to choose colors, exhibit colors reproducibly, inspect incoming materials, monitor color producing processes, and inspect finished goods. Visual appraisal is particularly important when the product inspected is not of the same material as the color standard to which it is compared.
Observers—This practice is based on the fundamental assumption that the observer has normal color vision and is trained and experienced in observing and classifying color differences. The significance of the results depends on that being so. The selection, evaluation, and training of observers are treated in Guide E1499.
Illumination—Simulated average daylight is recommended by the International Commission on Illumination (CIE), but a slightly bluer simulated north-sky daylight came into widespread use in North America, because it provides a slightly greater distinction between very pale yellow and white, a distinction of great commercial importance.
SCOPE
1.1 This practice specifies the equipment and procedures for visual appraisal of the colors and color differences of opaque materials that are diffusely illuminated. These specification are of critical importance in color matching. This practice requires judgments by observers with normal color vision.
1.2 Critical visual appraisal of colors and color differences of materials such as metallic and pearlescent paints requires illumination that is nearly a geometric simulation of sunlight, because such directional illumination permits observation of the glitter and goniochromatism that characterize such materials. Such viewing conditions are beyond the scope of this practice.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard4 pagesEnglish language
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
This practice applies to production quality control and customer acceptance of regularly transmitting sheet materials such as tinted windows where visual color discrimination is critical.
SCOPE
1.1 This practice was developed to help its users critically judge the transmitted color appearance of transparent sheet materials. Its primary application is for colored flat glass and plastic materials.
1.2 This practice is not meant to be used to evaluate colors of curved, diffusing, self-luminous, or opaque materials.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard4 pagesEnglish language
- Standard4 pagesEnglish language
ABSTRACT
This guide is intended to help the user decide on the type of viewing conditions, visual scaling methods, and analysis that should be used to obtain reliable visual experimental data. It is also intended to illustrate the techniques that lead to visual observations that can be correlated with objective instrumental measurements of appearance attributes of objects. This guide includes a review of issues regarding the choice and design of viewing environments, an overview of various classes of visual experiments, a review of experimental techniques for threshold, matching, and scaling experiments, a review for data reduction and analysis procedures. The three different threshold and matching techniques namely, the methods of adjustment, limits, and constant stimuli, are explained. Perceptual scaling techniques reviewed include ranking, graphical rating, category scaling, paired comparisons, triadic combinations, partitioning, and magnitude estimation or production. Brief descriptions and examples, along with references to more detailed literature, are given on the appropriate types of data analysis for each experimental technique.
SCOPE
1.1 This guide is intended to help the user decide on the type of viewing conditions, visual scaling methods, and analysis that should be used to obtain reliable visual data.
1.2 This guide is intended to illustrate the techniques that lead to visual observations that can be correlated with objective instrumental measurements of appearance attributes of objects. The establishment of both parts of such correlations is an objective of Committee E12.
1.3 Among ASTM standards making use of visual observations are Practices D1535, D1729, D3134, D4086, and E1478; Test Methods D2616, D3928, and D4449; and Guide E1499.
1.4 This guide does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide8 pagesEnglish language
- Guide8 pagesEnglish language
SIGNIFICANCE AND USE
Color specifications are centered around exact positions in color space. Correspondingly, gloss specifications are centered around an exact position on the gloss scale. Because it is difficult to achieve these exact positions repeatedly, it is necessary to specify tolerances that are acceptable to both the buyer and the seller. This practice details the procedure for accomplishing this goal.
SCOPE
1.1 This practice describes a procedure for establishing tolerances and evaluating the color and gloss of specimens with respect to specified standards. This practice is appropriate for nonfluorescent opaque specimens.
1.2 This practice does not indicate the extent of tolerances, but gives guidance on how they can be set. For product specification, the tolerances between specimens and the specified standard should be agreed upon between the purchaser and the seller.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard7 pagesEnglish language
- Standard7 pagesEnglish language
- Standard7 pagesEnglish language
SIGNIFICANCE AND USE
Gloss is associated with the capacity of a surface to reflect more light in some directions than in others. The directions associated with mirror (or specular) reflection normally have the highest reflectances. Gloss is best seen and analyzed when the surfaces studied are illuminated by a light source that provides strong contrasting patterns of light and dark. Such a light source is described in this test method.
The simplest concept of gloss is that it corresponds to the mirror-like reflectances of surfaces. However, the distributions and intensities of this surface-reflected light are (for real materials) highly variable and affected by a variety of factors: surface smoothness and contour, refractive index, absorptance, angle of incidence, and (to a generally small extent) wavelength. From the great variety of surface-reflection patterns met in materials of commerce, it has been possible to identify seven surface-reflection criteria or “types of gloss” regularly used by skilled technologists for intercomparing and rating their products for gloss. Six of the seven criteria, or “types of gloss,” are identified in the section on definitions. The seventh, luster or contrast gloss, is seldom of concern to the coatings industry.
SCOPE
1.1 This test method covers the visual evaluation of gloss differences of coating surfaces, using special types of lamps for illumination. It identifies six aspects or types of gloss that one may look for when using the lamp to assess gloss differences between surfaces. It describes the conditions for using the lamps to best identify small differences in each of the six types of gloss. Four levels of visual gloss differences are distinguished.
1.2 While this technique is useful for both weathered and unweathered specimens, it has not been applied to metallics.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard6 pagesEnglish language
- Standard6 pagesEnglish language
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
Metameric color matches result from the use of different colorants (pigments, dyes, and the like) in achieving the same color match. Usually, the purchaser requires that the color match be nonmetameric; this practice permits this requirement to be quickly tested in both field and laboratory. Where nonmetameric matches are not possible or practicable, for cost or other reasons, some limitation of metamerism may be required. The procedures for estimating the magnitude of metamerism described in this practice provide methods for assessing the effectiveness of such limitation.
SCOPE
1.1 This practice describes visual methods for detecting metamerism and for estimating the magnitude of a metameric color difference.
1.2 The practice is limited to the consideration of illuminant metamerism and observer metamerism. It is not designed to cover so-called geometric metamerism, in which members of specimen pairs change relative appearance as the angles of illumination and viewing are changed, for example, because they incorporate flake metal or pearlescent colorants.
1.3 This practice does not provide for the computation of indices of metamerism based upon instrumental measurement of spectral characteristics.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard2 pagesEnglish language
SIGNIFICANCE AND USE
Gloss3 is associated with the capacity of a surface to reflect more light in some directions than in others. The directions associated with mirror (or specular) reflection normally have the highest reflectances. Gloss is best seen and analyzed when the surfaces studied are illuminated by a light source that provides strong contrasting patterns of light and dark. Such a light source is described in this test method.
The simplest concept of gloss is that it corresponds to the mirror-like reflectances of surfaces. However, the distributions and intensities of this surface-reflected light are (for real materials) highly variable and affected by a variety of factors: surface smoothness and contour, refractive index, absorptance, angle of incidence, and (to a generally small extent) wavelength. From the great variety of surface-reflection patterns met in materials of commerce, it has been possible to identify seven surface-reflection criteria or “types of gloss” regularly used by skilled technologists for intercomparing and rating their products for gloss. Six of the seven criteria, or “types of gloss,” are identified in the section on definitions. The seventh, luster or contrast gloss, is seldom of concern to the coatings industry.
SCOPE
1.1 This test method covers the visual evaluation of gloss differences of coating surfaces, using special types of lamps for illumination. It identifies six aspects or types of gloss that one may look for when using the lamp to assess gloss differences between surfaces. It describes the conditions for using the lamps to best identify small differences in each of the six types of gloss. Four levels of visual gloss differences are distinguished.
1.2 While this technique is useful for both weathered and unweathered specimens, it has not been applied to metallics.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
Although color measuring instruments are widely used, color matches are usually checked visually. The standardization of visual examination has greatly improved the uniformity of products and the accuracy of color matches.
The use of this practice is essential for critical color matching but is also recommended for any color appraisal, such as the choice or approval of a color. This practice is widely used in industry to choose colors, exhibit colors reproducibly, inspect incoming materials, monitor color producing processes, and inspect finished goods. Visual appraisal is particularly important when the product inspected is not of the same material as the color standard to which it is compared.
4.2.1 Observers—This practice is based on the fundamental assumption that the observer has normal color vision and is trained and experienced in observing and classifying color differences. The significance of the results depends on that being so. The selection, evaluation, and training of observers are treated in Guide E 1499.
4.2.2 Illumination—Simulated average daylight is recommended by the International Commission on Illumination (CIE), but a slightly bluer simulated north-sky daylight came into widespread use in North America, because it provides a slightly greater distinction between very pale yellow and white, a distinction of great commercial importance.
SCOPE
1.1 This practice specifies the equipment and procedures for visual appraisal of the colors and color differences of opaque materials that are diffusely illuminated. These specification are of critical importance in color matching. This practice requires judgments by observers with normal color vision.
1.2 Critical visual appraisal of colors and color differences of materials such as metallic and pearlescent paints requires illumination that is nearly a geometric simulation of sunlight, because such directional illumination permits observation of the glitter and goniochromatism that characterize such materials. Such viewing conditions are beyond the scope of this practice.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
Color specifications are centered around exact positions in color space. Correspondingly, gloss specifications are centered around an exact position on the gloss scale. Because it is difficult to achieve these exact positions repeatedly, it is necessary to specify tolerances that are acceptable to both the buyer and the seller. This practice details the procedure for accomplishing this goal.
SCOPE
1.1 This practice describes a procedure for establishing tolerances and evaluating the color and gloss of specimens with respect to specified standards. This practice is appropriate for nonfluorescent opaque specimens.
1.2 This practice does not indicate the extent of tolerances, but gives guidance on how they can be set. For product specification, the tolerances between specimens and the specified standard should be agreed upon between the purchaser and the seller.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
This practice applies to production quality control and customer acceptance of regularly transmitting sheet materials such as tinted windows where visual color discrimination is critical.
SCOPE
1.1 This practice was developed to help its users critically judge the transmitted color appearance of transparent sheet materials. Its primary application is for colored flat glass and plastic materials.
1.2 This practice is not meant to be used to evaluate colors of curved, diffusing, self-luminous, or opaque materials.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard4 pagesEnglish language
SCOPE
1.1 This practice describes visual methods for detecting metamerism and for estimating the magnitude of a metameric color difference.
1.2 The practice is limited to the consideration of illuminant metamerism and observer metamerism. It is not designed to cover so-called geometric metamerism, in which members of specimen pairs change relative appearance as the angles of illumination and viewing are changed, for example, because they incorporate flake metal or pearlescent colorants.
1.3 This practice does not provide for the computation of indices of metamerism based upon instrumental measurement of spectral characteristics.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard2 pagesEnglish language
ABSTRACT
This guide is intended to help the user decide on the type of viewing conditions, visual scaling methods, and analysis that should be used to obtain reliable visual experimental data. It is also intended to illustrate the techniques that lead to visual observations that can be correlated with objective instrumental measurements of appearance attributes of objects. This guide includes a review of issues regarding the choice and design of viewing environments, an overview of various classes of visual experiments, a review of experimental techniques for threshold, matching, and scaling experiments, a review for data reduction and analysis procedures. The three different threshold and matching techniques namely, the methods of adjustment, limits, and constant stimuli, are explained. Perceptual scaling techniques reviewed include ranking, graphical rating, category scaling, paired comparisons, triadic combinations, partitioning, and magnitude estimation or production. Brief descriptions and examples, along with references to more detailed literature, are given on the appropriate types of data analysis for each experimental technique.
SCOPE
1.1 This guide is intended to help the user decide on the type of viewing conditions, visual scaling methods, and analysis that should be used to obtain reliable visual data.
1.2 This guide is intended to illustrate the techniques that lead to visual observations that can be correlated with objective instrumental measurements of appearance attributes of objects. The establishment of both parts of such correlations is an objective of Committee E12.
1.3 Among ASTM standards making use of visual observations are Practices D 1535, D 1729, D 3134, D 4086, and E 1478; Test Methods D 2616, D 3928, and D 4449; and Guide E 1499.
1.4 This guide does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide8 pagesEnglish language
SIGNIFICANCE AND USE
The term appearance (see 3.2.1) implies the essential presence of human visual observations. The results of visual observation involve not only the step of observing, accomplished by the eye, but also the inseparable step of interpretation in the brain. Instrumental test methods currently cannot duplicate this second step, and therefore can now only approximate, but not fully measure, appearance. Such instrumental measures of appearance properties are useful only to the extent that they can be correlated to the results of visual observations by observers of the appearance phenomena being evaluated.
Almost invariably, too little attention has been paid to ensuring that the essential visual observations have been properly obtained to provide the basis for correlating visual and instrumental test results. (The only recent book devoted to visual measurements (1)3 has no index entry for observer.)
This guide provides the means for assessing observers, by outlining the requirements and tests for their selection, evaluation, and training. This guide should be useful to all experimenters designing or using visual test methods to provide either direct results in terms of the observation of appearance properties, or the experiments correlating such results with instrumental measures approximating the same appearance properties.
SCOPE
1.1 This guide describes criteria and tests for selecting, evaluating, and training human visual-sensory observers for tasks involving the perception and scaling of properties and phenomena relating to appearance.
1.2 Examples of tests requiring the use of trained observers include but are not limited to those described in the following ASTM standards: on color, Practice D 1535 and Practice E 1360; on color difference, Practice D 1729 and Test Method D 2616; on gloss, Test Method D 4449; on metamerism, Practice D 4086; and on setting tolerances, Practice D 3134.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide4 pagesEnglish language
SCOPE
1.1 This method covers the visual evaluation of gloss differences of coating surfaces, using special types of lamps for illumination. It identifies six aspects or types of gloss that one may look for when using the lamp to assess gloss differences between surfaces. It describes the conditions for using the lamps to best identify small differences in each of the six types of gloss. Four levels of visual gloss differences are distinguished.
1.2 While this technique is useful for both weathered and unweathered specimens, it has not been applied to metallics.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard6 pagesEnglish language
SCOPE
1.1 This practice was developed to help its users critically judge the transmitted color appearance of transparent sheet materials. Its primary application is for colored flat glass and plastic materials.
1.2 This practice is not meant to be used to evaluate colors of curved, diffusing, self-luminous, or opaque materials.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
SCOPE
1.1 This practice describes a procedure for establishing tolerances and evaluating the color and gloss of specimens with respect to specified standards. This practice is appropriate for non fluorescent opaque specimens.
1.2 This practice does not indicate the extent of tolerances, but gives guidance on how they can be set. For product specification, the tolerances between specimens and the specified standard should be agreed upon between purchaser and seller.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard6 pagesEnglish language
SCOPE
1.1 This guide describes criteria and tests for selecting, evaluating, and training human visual-sensory observers for tasks involving the perception and scaling of properties and phenomena relating to appearance.
1.2 Examples of tests requiring the use of trained observers include but are not limited to those described in the following ASTM standards: on color, Test Method D1535 and Practice E1360; on color difference, Practice D1729 and Test Method D2616; on gloss, Test Method D4449; on metamerism, Practice D4086; and on setting tolerances, Practice D3134.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide4 pagesEnglish language
SCOPE
1.1 This practice describes visual methods for detecting metamerism and for estimating the magnitude of a metameric color difference.
1.2 The practice is limited to the consideration of illuminant metamerism and observer metamerism. It is not designed to cover so-called geometric metamerism, in which members of specimen pairs change relative appearance as the angles of illumination and viewing are changed, for example, because they incorporate flake metal or pearlescent colorants.
1.3 This practice does not provide for the computation of indices of metamerism based upon instrumental measurement of spectral characteristics.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard2 pagesEnglish language
SCOPE
1.1 This guide is intended to help the user decide on the type of viewing conditions, visual scaling methods, and analysis that should be used to obtain reliable visual data.
1.2 This guide is intended to illustrate the techniques that lead to visual observations that can be correlated with objective instrumental measurements of appearance attributes of objects. The establishment of both parts of such correlations is an objective of Committee E-12.
1.3 Among ASTM standards making use of visual observations are Practices D1535, D1729, D3134, D4086, and E1478; Test Methods D2616, D3928, and D4449; and Guide E1499.
1.4 This guide does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide8 pagesEnglish language
SCOPE
1.1 This practice specifies the equipment and procedures for visual appraisal of the colors and color differences of opaque materials that are diffusely illuminated. These specification are of critical importance in color matching. This practice requires judgments by observers with normal color vision.
1.2 Critical visual appraisal of colors and color differences of materials such as metallic and pearlescent paints requires illumination that is nearly a geometric simulation of sunlight, because such directional illumination permits observation of the glitter and goniochromatism that characterize such materials. Such viewing conditions are beyond the scope of this practice.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard4 pagesEnglish language
SCOPE
1.1 This test method describes a painted gray scale and the procedure to be used in the visual evaluation of color differences of non-self luminous materials by comparison to this scale.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice applies to production quality control and customer acceptance of regularly transmitting sheet materials such as tinted windows where visual color discrimination is critical.
SCOPE
1.1 This practice was developed to help its users critically judge the transmitted color appearance of transparent sheet materials. Its primary application is for colored flat glass and plastic materials.
1.2 This practice is not meant to be used to evaluate colors of curved, diffusing, self-luminous, or opaque materials.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
WITHDRAWN RATIONALE
This practice was developed to help its users critically judge the transmitted color appearance of transparent sheet materials. Its primary application is for colored flat glass and plastic materials.
Formerly under the jurisdiction of Committee E12 on Color and Appearance, this practice was withdrawn in May 2022. This standard is being withdrawn without replacement due to its limited use by industry.
- Standard4 pagesEnglish language
Frequently Asked Questions
E12.11 is a Technical Committee within ASTM International. It is named "Visual Methods". This committee has published 39 standards.
E12.11 develops ASTM standards in the area of Information technology. Currently, there are 39 published standards from this technical committee.
ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.
A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.