This document specifies an engineering method for the measurement of sound pressure levels in rooms from service equipment installed in the building.
This document covers specifically measurements of sound from sanitary installations, mechanical ventilation, heating and cooling service equipment, lifts, rubbish chutes, heating devices, blowers, pumps and other auxiliary service equipment, and motor driven car park doors. It can also be applied to measurements of sounds from other types of equipment or activities within the building, e.g. noise from sport facilities or restaurants.
The measurement of noise from external sound sources generating air-borne or ground-borne noise in the building are not included in this document.
The methods are suitable for rooms with volumes of approximately 300 m3 or less for instance, in dwellings, hotels, schools, offices and hospitals.
The methods are not intended for measurements in large auditoria or concert halls.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers the assessment and verification of constancy of performance and the factory production control of basic alumino silicate glass products for use in buildings.
NOTE   For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for basic soda lime silicate glass products, as defined in EN 572-1:2012, for use in building. It applies to supplied sizes or cut sizes for final end use.
This European Standard does not apply to final cut sizes having a dimension less than 100 mm or a surface area less than 0,05 m².
This European Standard does not apply to float glass supplied as jumbo, split sizes or oversize plates nor to polished wired glass, drawn sheet glass, patterned glass, patterned wired glass supplied as stock sizes. For specifications regarding these types of glass, see EN 572-2:2012, EN 572-3:2012, EN 572-4:2012, EN 572-5:2012 and EN 572-6:2012 respectively.
This European Standard does not apply to final cut sizes of wired or unwired channel shaped glass For specifications on this type of glass, see EN 572-7:2012.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of this European Standard specifies and classifies basic glass products and indicates their chemical composition, their main physical and mechanical characteristics and defines their general quality criteria.
Specific dimensions and dimensional tolerances, description of faults, quality limits and designation for each basic product type are not included in this Part, but are given in other Parts of EN 572 specific to each product type:
-   EN 572-2   Float glass;
-   EN 572-3   Polished wired glass;
-   EN 572-4   Drawn sheet glass;
-   EN 572-5   Patterned glass;
-   EN 572-6   Wired patterned glass;
-   EN 572-7   Wired or unwired channel shaped glass;
-   EN 572-8   Supplied and final cut sizes;
-   EN 572-9   Evaluation of conformity/Product standard.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of this European Standard specifies and classifies basic alumino silicate glass products, indicates their chemical composition, their main physical and mechanical characteristics, their dimensional and their minimum quality requirements (in respect of optical and visual faults).
This European Standard applies to basic alumino silicate glasses supplied in stock sizes, supplied sizes or in cut sizes for final end use.
This European Standard does not apply to final cut sizes having a dimension less than 100 mm or a surface area less than 0,05 m2.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for wired patterned glass, as defined in EN 572-1:2012, for use in building.
This European Standard applies only to wired patterned glass supplied in rectangular panes and in stock sizes.
EN 572-8 gives information on patterned wired glass in sizes other than those covered by this European Standard.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of optical, visual and wire faults) for polished wired glass, as defined in EN 572-1:2012, for use in building.
This European Standard applies only to polished wired glass supplied in rectangular panes and in stock sizes.
EN 572-8 gives information on polished wired glass in sizes other than those covered by this European Standard.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for float glass, as defined in EN 572-1:2012, for use in building.
This European Standard applies only to float glass supplied in jumbo sizes (see Note 1), split sizes (see Note 2) and oversize plates (see Note 3).
NOTE 1   Jumbo sizes - PLF (plateau largeur de fabrication) - Bandmasse.
NOTE 2   Split sizes - DLF (dimension largeur de fabrication) - Geteilte Bandmasse.
NOTE 3   Oversize plates - these are plates where the nominal length, H, is greater than 6 000 mm. These plates are produced to special order.
EN 572-8 gives information on float glass in sizes (i.e. supplied and final cut sizes) other than those covered by this European Standard.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of visual and pattern faults) for patterned glass as defined in EN 572-1:2012, for use in building.
This European Standard applies only to patterned glass supplied in rectangular panes and in stock sizes.
EN 572-8 gives information on patterned glass in sizes other than those covered by this European Standard.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for drawn sheet glass, as defined in EN 572-1:2012, for use in building.
This European Standard applies only to drawn sheet glass supplied in rectangular panes and in stock sizes.
EN 572-8 gives information on drawn sheet glass in sizes other than those covered by this European Standard.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of visual and wire faults) for channel shaped glass, as defined in EN 572-1:2012, for use in building.
This European Standard covers channel shaped glass supplied in stock sizes and final cut sizes.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers the evaluation of conformity and the factory production control of basic alkaline earth silicate glass products for use in buildings.
Note: For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers the evaluation of conformity and the factory production control of borosilicate glass products for use in buildings.
Note: For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers the evaluation of conformity and the factory production control of basic soda lime silicate glass products for use in buildings.
Note: For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers the evaluation of conformity and the factory production control of glass ceramics for use in buildings.
Note: For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines and classifies basic alkaline earth silicate glasses for use in building. It indicates their chemical composition, main physical and mechanical properties, dimensional and minimum quality requirements (in respect of optical and visual faults).
This document applies to basic alkaline earth silicate glasses supplied in jumbo sizes, split sizes and final cut sizes.
This document does not apply to final cut sizes having a dimension less than 100mm or a surface area less than 0,05m².

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines and classifies borosilicate glasses for use in building.  It indicates their chemical composition, main physical and mechanical properties, dimensional and minimum quality requirements (in respect of optical and visual faults).
This document applies to borosilicate glasses supplied in stock sizes or in cut sizes for final end use.
This document does not apply to final cut sizes having a dimension less than 100 mm or a surface area less than 0,05 m².

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines, specifies and classifies glass ceramics for use in building.  It indicates their chemical composition, main physical and mechanical properties, dimensional and minimum quality requirements (in respect of optical and visual faults).
This document applies to glass ceramics supplied in stock sizes or in cut sizes for final end use.
This document does not apply to final cut sizes having a dimension less than 100 mm or a surface area less than 0,05 m².

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard covers the evaluation of conformity and the factory production control of basic glass ceramics for use in buildings.
NOTE   For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Draft
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies and classifies special basic products - glass ceramics, indicates their chemical composition, their main physical and mechanical characteristics, their dimensional and minimum quality requirements (in respect of optical and visual faults).
This European Standard applies to special basic products - glass ceramics supplied in stock sizes, supplied sizes or in cut sizes for final end use.
This European Standard does not apply to final cut sizes having a dimension less than 100 mm or a surface area less than 0,05 m2.

  • Draft
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard covers the evaluation of conformity and the factory production control of basic borosilicate float glass for use in buildings.
For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Draft
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies and classifies special basic products - borosilicate float glass, indicates their chemical composition, their main physical and mechanical characteristics, their dimensional and minimum quality requirements (in respect of optical and visual faults).
This European Standard applies to special basic products - borosilicate float glass supplied in stock sizes, supplied sizes or in cut sizes for final end use.
This European Standard does not apply to final cut sizes having a dimension less than 100 mm or a surface area less than 0,05 m².

  • Draft
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers the evaluation of conformity and the factory production control of basic soda lime silicate glass products for use in buildings.
For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Draft
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard covers the evaluation of conformity and the factory production control of basic alkaline earth silicate glass for use in buildings.
For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Draft
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard specifies and classifies basic alkaline earth silicate glass products for use in building. It indicates their chemical composition, main physical and mechanical properties, dimensional and minimum quality requirements (in respect of optical and visual faults).
This European standard applies to basic alkaline earth silicate glass supplied in jumbo sizes, split sizes, supplied sizes or in cut sizes for final end use.
This European standard does not apply to final cut sizes having a dimension less than 100 mm or a surface area less than 0,05 m².

  • Draft
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for basic soda lime silicate glass products, as defined in EN 572 1:2012, for use in building. It applies to supplied sizes or cut sizes for final end use.
This European Standard does not apply to final cut sizes having a dimension less than 100 mm or a surface area less than 0,05 m².
This European Standard does not apply to float glass supplied as jumbo, split sizes or oversize plates nor to polished wired glass, drawn sheet glass, patterned glass, patterned wired glass supplied as stock sizes. For specifications regarding these types of glass, see EN 572 2:2012, EN 572 3:2012, EN 572 4:2012, EN 572 5:2012 and EN 572 6:2012 respectively.
This European Standard does not apply to final cut sizes of wired or unwired channel shaped glass For specifications on this type of glass, see EN 572 7:2012.

  • Draft
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of this European Standard specifies and classifies basic glass products and indicates their chemical composition, their main physical and mechanical characteristics and defines their general quality criteria.
Specific dimensions and dimensional tolerances, description of faults, quality limits and designation for each basic product type are not included in this Part, but are given in other Parts of this European Standard specific to each product type:
-   EN 572-2   Float glass
-   EN 572-3   Polished wired glass
-   EN 572-4   Drawn sheet glass
-   EN 572-5   Patterned glass
-   EN 572-6   Wired patterned glass
-   EN 572-7   Wired or unwired channel shaped glass
-   EN 572-8   Supplied and final cut sizes
-   EN 572-9   Evaluation of conformity/Product standard

  • Draft
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers the evaluation of conformity and the factory production control of basic alumino silicate glass products for use in buildings.
Note: For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Draft
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines and classifies basic alumino silicate glass products for use in building. It indicates their chemical composition, main physical and mechanical properties, dimensional and minimum quality requirements (in respect of optical and visual faults). This European standard applies to basic alumino silicate glasses supplied in stock sizes or in cut sizes for final end use. This European standard does not apply to final cut sizes having a dimension less than 100 mm or a surface area less than 0,05 m².

  • Draft
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for basic soda lime silicate glass products, as defined in EN 572 1:2012, for use in building. It applies to supplied sizes or cut sizes for final end use.
This European Standard does not apply to final cut sizes having a dimension less than 100 mm or a surface area less than 0,05 m².
This European Standard does not apply to float glass supplied as jumbo, split sizes or oversize plates nor to polished wired glass, drawn sheet glass, patterned glass, patterned wired glass supplied as stock sizes. For specifications regarding these types of glass, see EN 572 2:2012, EN 572 3:2012, EN 572 4:2012, EN 572 5:2012 and EN 572 6:2012 respectively.
This European Standard does not apply to final cut sizes of wired or unwired channel shaped glass For specifications on this type of glass, see EN 572 7:2012.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of this European Standard specifies and classifies basic glass products and indicates their chemical composition, their main physical and mechanical characteristics and defines their general quality criteria.
Specific dimensions and dimensional tolerances, description of faults, quality limits and designation for each basic product type are not included in this Part, but are given in other Parts of this European Standard specific to each product type:
-   EN 572-2   Float glass
-   EN 572-3   Polished wired glass
-   EN 572-4   Drawn sheet glass
-   EN 572-5   Patterned glass
-   EN 572-6   Wired patterned glass
-   EN 572-7   Wired or unwired channel shaped glass
-   EN 572-8   Supplied and final cut sizes
-   EN 572-9   Evaluation of conformity/Product standard

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of this European Standard specifies dimensional and minimum quality requirements (in respect of visual and wire faults) for channel shaped glass, as defined in EN 572-1, for use in building.
This Part of this standard covers channel shaped glass supplied in stock sizes and final cut sizes.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

TThis Part of this European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for drawn sheet glass, as defined in EN 572-1, for use in building.
This Part of this standard applies only to drawn sheet glass supplied in rectangular panes and in stock sizes.
EN 572-8 gives information on drawn sheet glass in sizes other than those covered by this Part.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of this European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for float glass, as defined in EN 572-1, for use in building.
This Part of this standard applies only to float glass supplied in jumbo sizes (see note 1) and split sizes (see note 2).
NOTE 1   Jumbo sizes - PLF (plateau largeur de fabrication) - Bandmasse.
NOTE 2   Split sizes - DLF (dimension largeur de fabrication) - Geteilte Bandmasse.
EN 572-8 gives information on float glass in sizes other than those covered by this Part.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of this European Standard specifies dimensional and minimum quality requirements (in respect of visual and pattern faults) for patterned glass as defined in EN 572-1, for use in building.
This Part of this standard applies only to patterned glass supplied in rectangular panes and in stock sizes.
EN 572-8 gives information on patterned glass in sizes other than those covered by this Part.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of this European Standard specifies dimensional and minimum quality requirements (in respect of optical, visual and wire faults) for polished wired glass, as defined in EN 572-1, for use in building.
This Part of this standard applies only to polished wired glass supplied in rectangular panes and in stock sizes.
EN 572-8 gives information on polished wired glass in sizes other than those covered by this Part.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of this European Standard specifies and classifies basic glass products, indicates their chemical composition, their main physical and mechanical characteristics and defines their general quality criteria.
Specific dimensions and dimensional tolerances, description of faults, quality limits and designation for each basic product type are not included in this Part, but are given in other Parts of this standard specific to each product type:
EN 572-2   Float glass
EN 572-3   Polished wire glass
EN 572-4   Drawn sheet glass
EN 572-5   Patterned glass
EN 572-6   Wired patterned glass
EN 572-7   Wired or unwired channel shaped glass
EN 572-8   Supplied and final cut sizes
EN 572-9   Evaluation of conformity/Product standard

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of this European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for float glass, as defined in EN 572-1, for use in building.
This Part of this standard applies only to wired patterned glass supplied in rectangular panes and in stock sizes.
EN 572-8 gives information on patterned wired glass in sizes other than those covered by this Part.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of this European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for basic soda lime silicate glass products, as defined in EN 572-1, for use in building. It applies to supplied sizes or cut sizes for final end use.
This part of this European Standard does not apply to final cut sizes having a dimension less than 100 mm or a surface area less than 0,05m².
This part of this European Standard does not apply to float glass supplied as jumbo or split sizes, see EN 572-2, or to polished wired glass, drawn sheet glass, patterned glass and patterned wired glass supplied as stock sizes, see EN 572-3, EN 572-4, EN 572-5 and EN 572-6.
This part of this European Standard does not apply to final cut sizes of wired or unwired channel shaped glass, see EN 572-7.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines, specifies and classifies glass ceramics for use in building. It indicates their chemical composition, main physical and mechanical properties, dimensional and minimum quality requirements (in respect of optical and visual faults). This standard applies only to glass ceramics supplied in stock sizes. This standard does not apply to glass ceramics suppliedin cut sizes for final end use.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard defines and classifies borosilicate glasses for use in building. It indicates their chemical composition, main physical and mechanical properties, dimensional and minimum quality requirements (in respect of optical and visual faults). This standard applies only to borosilicate glasses supplied in stock sizes. This standard does not apply to borosilicate glasses supplied in cut sizes for final end use.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of this European standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for drawn sheet glass as defined in EN 572 Part 1, for use in building. This part of this standard applies only to drawn sheet glass supplied in rectangular panes and in stock sizes. This part of this standard does not apply to glass in cut sizes for final end use.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of this European standard specifies dimensional and minimum quality requirements (in respect of visual, pattern and wire faults) for wired patterned glass, as defined in EN 572 Part 1, for use in building. This part of this standard applies only to wired patterned glass supplied in rectangular panes andin stock sizes.  This part of this standard does not apply to glass in cut sizes for final end use.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of this European Standard specifies dimensional and minimum quality requirements (in respect of visual and wire faults) for channel shaped glass as defined in EN 572 part 1 for use in building. This part of this standard covers channel shaped glass supplied in stock sizes.  This part of this standard does not apply to channel shaped glass in cut sizes for final end use.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of this European standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for float glass, as defined in EN572 Part 1, for use in building. This part of this standard applies only to float glass suplied in Jumbo sizes and Split sizes. This part of this standard does not apply to glass in cut sizes for final end use.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard defines and classifies basic glass products, indicates their chemical composition, their main physical and mechanical characteristics and their general quality criteria. Specific dimensions and dimensional tolerances, description of faults, quality limits and designation for each basic product type are not included in this part, but are given in other parts of this standard specific to each product type.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of this European standard specifies dimensional and minimum quality requirements (in respect of visual and pattern faults) for patterned glass as defined in EN 572 part 1, for use in building. This part of this standard applies only to patterned  glass supplied in rectangular panes and in stock sizes. This part of this standard does not apply to patterned glass in cut sizes for final end use.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of this European standard specifies dimensional and minimum quality requirements (in respect of optical, visual and wire faults) for polished wired glass, as defined in EN 572 part 1, for use in building. This part of this standard applies only to polished wired glass supplied in rectangular panes and in stock sizes. This part of this standard does not apply to glass in cut sizes for final end use.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day