CEN/TC 296/WG 3 - Design and construction of pressure tanks (Pressure > 0,5 Bar)
Standardisation of design and construction of metallic pressure tanks, including openings, closures and structures but excluding service equipment, intended for the transport of dangerous goods and having a maximum working pressure higher than 50kPa.
Design and construction of pressure tanks (Pressure > 0,5 Bar)
Standardisation of design and construction of metallic pressure tanks, including openings, closures and structures but excluding service equipment, intended for the transport of dangerous goods and having a maximum working pressure higher than 50kPa.
General Information
This document specifies the minimum requirements for the design and construction of metallic
pressure tanks for the transport of dangerous goods by road and rail and sea. It is not
applicable to gravity-discharge tanks according to RID/ADR 6.8.2.1.14 (a).
This document includes requirements for openings, closures and structural equipment; it does not cover requirements of service equipment. For tanks for the transport of cryogenic liquids, EN 13530-1 and EN 13530-2 apply.
Design and construction of pressure tanks according to the Scope of this document are primarily subject to the requirements of RID/ADR, Subsections 6.8.2.1, 6.8.3.1 and 6.8.5, as relevant. In addition, the relevant requirements of RID/ADR, Table A, columns 12 and 13, to Chapters 3.2, 4.3 and Subsection 6.8.2.4 apply. For the structural equipment RID/ADR, Subsections 6.8.2.2 and 6.8.3.2 apply, as relevant. The definitions of RID/ADR, Subsection 1.2.1, are referred to. For portable tanks see also RID/ADR, Chapter 4.2 and Sections 6.7.2 and 6.7.3. In addition, the relevant requirements of RID/ADR, Table A, Columns 10 and 11 to Chapters 3.2, 4.2, and Sections 6.7.2 and 6.7.3 apply. The paragraph numbers above relate to the 2017 issue of RID/ADR which are subject to regular revisions. This can lead to temporary non-compliances with EN 14025.
This document is applicable to liquefied gases including LPG; however for a dedicated LPG standard see EN 12493.
If not otherwise specified, provisions which take up the whole width of the page apply to all kind of tanks. Provisions contained in a single column apply only to:
-tanks according to RID/ADR Chapter 6.8 (left-hand column);
-portable tanks according to RID/ADR Chapter 6.7 (right-hand column).
- Standard64 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements for foot valves for use on tanks with a minimum working pressure greater than 50 kPa for the transport of dangerous goods by road and rail.
It is applicable to metallic equipment on tanks for the following functions for internal stop valves:
- primary closure of gravity discharge lines (liquid substances);
- primary closure of bottom discharge lines (liquid gases: liquid phase and gas phase);
- primary closure of top discharge (poisonous liquefied gases: liquid phase and gas phase);
- and other internal valves as specified in Annex F of EN 14564:2019 according to the scope of this document.
NOTE 1 The document is also applicable to liquefied gases including LPG; however, for a dedicated LPG standard see EN 13175 [3].
NOTE 2 Valves according to this document can be used as primary closure in case of top discharge of liquids and other products.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements for valves useable on tanks with a minimum working pressure greater than 50 kPa for the transport of dangerous goods by road and rail for the following functions:
Tanks for transport of liquid products:
- secondary closure of bottom discharge lines;
- primary closure on top of the tank (liquid, air, other connections);
- aeration valve on top of the tank;
- and other valves as specified in Annex F of EN 14564:2019 according to the scope of this document.
Tanks for gases:
- secondary closure of bottom discharge lines;
- secondary closure on top of the tank for poisonous gases: liquid phase and gas phase;
- and other valves as specified in Annex F of EN 14564:2019.
This includes the following types of closures:
- valves (e.g. spindle operated valves, plug and ball valves, butterfly valves and gate valves);
- dry disconnect couplings.
Primary closures of the gas phase at the foot of a tank for liquefied gas are covered by the requirements of foot valves in EN 14433.
NOTE The standard is also applicable to liquefied gases including LPG, however, for a dedicated LPG standard see EN 13175 [3]
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the minimum requirements for the design and construction of metallic pressure tanks having a maximum working pressure exceeding 50 kPa (0,5 bar), for the transport of dangerous goods by road and rail and sea. This document includes requirements for openings, closures and structural equipment; it does not cover requirements of service equipment. For tanks for the transport of cryogenic liquids, EN 13530 1 and EN 13530 2 apply.
Design and construction of pressure tanks according to the Scope of this document are primarily subject to the requirements of RID/ADR, Subsections 6.8.2.1, 6.8.3.1 and 6.8.5, as relevant. In addition, the relevant requirements of RID/ADR, Table A, columns 12 and 13, to Chapters 3.2, 4.3 and Subsection 6.8.2.4 apply. For the structural equipment RID/ADR, Subsections 6.8.2.2 and 6.8.3.2 apply, as relevant. The definitions of RID/ADR, Subsection 1.2.1, are referred to. For portable tanks see also RID/ADR, Chapter 4.2 and Sections 6.7.2 and 6.7.2. In addition, the relevant requirements of RID/ADR, Table A, Columns 10 and 11 to Chapters 3.2, 4.2, and Sections 6.7.2 and 6.7.3 apply. The paragraph numbers above relate to the 2017 issue of RID/ADR which are subject to regular revisions. This can lead to temporary non-compliances with EN 14025.
This document is applicable to liquefied gases including LPG; however for a dedicated LPG standard see EN 12493.
If not otherwise specified, provisions which take up the whole width of the page apply to all kind of tanks. Provisions contained in a single column apply only to:
tanks according to RID/ADR Chapter 6.8 (left-hand column); portable tanks according to RID/ADR Chapter 6.7 (right-hand column).
- Draft4 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the minimum requirements for the design and construction of metallic pressure tanks having a maximum working or test pressure exceeding 50 kPa (0,5 bar), for the transport of dangerous goods by road and rail and sea. This European Standard includes requirements for openings,closures and structural equipment; it does not cover requirements of service equipment. For tanks for the
transport of cryogenic liquids, EN 13530-1 and EN 13530-2 apply.
NOTE 1 Design and construction of pressure tanks according to the scope of this European Standard are primarily subject to the requirements of RID/ADR, 6.8.2.1, 6.8.3.1 and 6.8.5, as relevant. In addition, the relevant requirements of RID/ADR, columns 12 and 13 of Table A to chapter 3.2, 4.3 and 6.8.2.4 apply. For the structural equipment subsections 6.8.2.2 and 6.8.3.2 apply, as relevant. The definitions of RID/ADR 1.2.1 are referred to. For portable tanks see also Chapter 4.2 and Sections 6.7.2 and 6.7.3 of RID and ADR. In addition, the relevant requirements of RID/ADR, columns 10 and 11 of Table A to Chapter 3.2, 4.2, 6.7.2 and 6.7.3 apply. The paragraph numbers above relate to the 2013 issue of RID/ADR which are subject to regular revisions. This can lead to temporary non-compliances with EN 14025. It is
important to know that requirements of RID/ADR take precedence over any clause of this standard.
NOTE 2 This standard is applicable to liquefied gases including LPG, however for a dedicated LPG standard see EN 12493.
If not otherwise specified, provisions which take up the whole width of the page apply to all kind of tanks.
Provisions contained in a single column apply only to:
road and rail pressure tanks according to RID/ADR chapter 6.8 (left-hand column); ortable tanks according to RID/ADR chapter 6.7 right-hand column).
- Draft6 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the minimum requirements for the design and construction of metallic pressure tanks having a maximum working pressure exceeding 50 kPa (0,5 bar), for the transport of dangerous goods by road and rail and sea. This document includes requirements for openings, closures and structural equipment; it does not cover requirements of service equipment. For tanks for the transport of cryogenic liquids, EN 13530 1 and EN 13530 2 apply.
Design and construction of pressure tanks according to the Scope of this document are primarily subject to the requirements of RID/ADR, Subsections 6.8.2.1, 6.8.3.1 and 6.8.5, as relevant. In addition, the relevant requirements of RID/ADR, Table A, columns 12 and 13, to Chapters 3.2, 4.3 and Subsection 6.8.2.4 apply. For the structural equipment RID/ADR, Subsections 6.8.2.2 and 6.8.3.2 apply, as relevant. The definitions of RID/ADR, Subsection 1.2.1, are referred to. For portable tanks see also RID/ADR, Chapter 4.2 and Sections 6.7.2 and 6.7.2. In addition, the relevant requirements of RID/ADR, Table A, Columns 10 and 11 to Chapters 3.2, 4.2, and Sections 6.7.2 and 6.7.3 apply. The paragraph numbers above relate to the 2017 issue of RID/ADR which are subject to regular revisions. This can lead to temporary non-compliances with EN 14025.
This document is applicable to liquefied gases including LPG; however for a dedicated LPG standard see EN 12493.
If not otherwise specified, provisions which take up the whole width of the page apply to all kind of tanks. Provisions contained in a single column apply only to:
tanks according to RID/ADR Chapter 6.8 (left-hand column); portable tanks according to RID/ADR Chapter 6.7 (right-hand column).
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the minimum requirements for the design and construction of metallic pressure tanks having a maximum working pressure exceeding 50 kPa (0,5 bar), for the transport of dangerous goods by road and rail and sea. This document includes requirements for openings, closures and structural equipment; it does not cover requirements of service equipment. For tanks for the transport of cryogenic liquids, EN 13530 1 and EN 13530 2 apply.
Design and construction of pressure tanks according to the Scope of this document are primarily subject to the requirements of RID/ADR, Subsections 6.8.2.1, 6.8.3.1 and 6.8.5, as relevant. In addition, the relevant requirements of RID/ADR, Table A, columns 12 and 13, to Chapters 3.2, 4.3 and Subsection 6.8.2.4 apply. For the structural equipment RID/ADR, Subsections 6.8.2.2 and 6.8.3.2 apply, as relevant. The definitions of RID/ADR, Subsection 1.2.1, are referred to. For portable tanks see also RID/ADR, Chapter 4.2 and Sections 6.7.2 and 6.7.2. In addition, the relevant requirements of RID/ADR, Table A, Columns 10 and 11 to Chapters 3.2, 4.2, and Sections 6.7.2 and 6.7.3 apply. The paragraph numbers above relate to the 2017 issue of RID/ADR which are subject to regular revisions. This can lead to temporary non-compliances with EN 14025.
This document is applicable to liquefied gases including LPG; however for a dedicated LPG standard see EN 12493.
If not otherwise specified, provisions which take up the whole width of the page apply to all kind of tanks. Provisions contained in a single column apply only to:
tanks according to RID/ADR Chapter 6.8 (left-hand column); portable tanks according to RID/ADR Chapter 6.7 (right-hand column).
- Standard61 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for product discharge and air inlet valves for use on transportable tanks with a minimum working pressure greater than 50 kPa for the transport of dangerous goods by road and rail.
NOTE 1 The term 'valve' includes ball valves as well as butterfly valves and similar closure devices.
It is applicable to metallic equipment for use on tanks with gravity and/or pressure filling and discharge for liquid chemicals and liquefied gases. It includes carbon dioxide while excluding refrigerated liquefied gases.
NOTE 2 The standard is also applicable to liquefied gases including LPG, however, for a dedicated LPG standard see EN 13175 [3].
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for foot valves for use on transportable tanks with a minimum working pressure greater than 50 kPa for the transport of dangerous goods by road and rail.
It is applicable to metallic equipment for use on tanks with gravity and/or pressure bottom loading and discharge for liquid chemicals and liquefied gases. It includes carbon dioxide while excluding refrigerated liquefied gases.
NOTE The standard is also applicable to liquefied gases including LPG, however, for a dedicated LPG standard see EN 13175 [3].
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the minimum requirements for the design and construction of metallic pressure tanks having a maximum working or test pressure exceeding 50 kPa (0,5 bar), for the transport of dangerous goods by road and rail and sea. This European Standard includes requirements for openings,closures and structural equipment; it does not cover requirements of service equipment. For tanks for the
transport of cryogenic liquids, EN 13530-1 and EN 13530-2 apply.
NOTE 1 Design and construction of pressure tanks according to the scope of this European Standard are primarily subject to the requirements of RID/ADR, 6.8.2.1, 6.8.3.1 and 6.8.5, as relevant. In addition, the relevant requirements of RID/ADR, columns 12 and 13 of Table A to chapter 3.2, 4.3 and 6.8.2.4 apply. For the structural equipment subsections 6.8.2.2 and 6.8.3.2 apply, as relevant. The definitions of RID/ADR 1.2.1 are referred to. For portable tanks see also Chapter 4.2 and Sections 6.7.2 and 6.7.3 of RID and ADR. In addition, the relevant requirements of RID/ADR, columns 10 and 11 of Table A to Chapter 3.2, 4.2, 6.7.2 and 6.7.3 apply. The paragraph numbers above relate to the 2013 issue of RID/ADR which are subject to regular revisions. This can lead to temporary non-compliances with EN 14025. It is
important to know that requirements of RID/ADR take precedence over any clause of this standard.
NOTE 2 This standard is applicable to liquefied gases including LPG, however for a dedicated LPG standard see EN 12493.
If not otherwise specified, provisions which take up the whole width of the page apply to all kind of tanks.
Provisions contained in a single column apply only to:
road and rail pressure tanks according to RID/ADR chapter 6.8 (left-hand column); ortable tanks according to RID/ADR chapter 6.7 right-hand column
- Standard58 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the minimum requirements for the design and construction of metallic pressure tanks having a maximum working or test pressure exceeding 50 kPa (0,5 bar), for the transport of dangerous goods by road and rail and sea. This European Standard includes requirements for openings, closures and structural equipment; it does not cover requirements of service equipment. For tanks for the transport of cryogenic liquids, EN 13530-1 and EN 13530-2 apply.
NOTE Design and construction of pressure tanks according to the scope of this European Standard are primarily subject to the requirements of RID/ADR, 6.8.2.1, 6.8.3.1 and 6.8.5, as relevant. In addition, the relevant requirements of RID/ADR, columns 12 and 13 of Table A to chapter 3.2, 4.3 and 6.8.2.4 apply. For the structural equipment subsections 6.8.2.2 and 6.8.3.2 apply, as relevant. The definitions of RID/ADR 1.2.1 are referred to. For portable tanks see also Chapter 4.2 and Sections 6.7.2 and 6.7.3 of RID and ADR. In addition, the relevant requirements of RID/ADR, columns 10 and 11 of Table A to Chapter 3.2, 4.2, 6.7.2 and 6.7.3 apply.
The paragraph numbers above relate to the 2013 issue of RID/ADR which are subject to regular revisions. This can lead to temporary non-compliances with EN 14025. It is important to know that requirements of RID/ADR take precedence over any clause of this standard.
If not otherwise specified, provisions which take up the whole width of the page apply to all kind of tanks. Provisions contained in a single column apply only to:
road and rail pressure tanks according to RID/ADR chapter 6.8 (left-hand column); portable tanks according to RID/ADR chapter 6.7 (right-hand column).
- Standard56 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for product discharge and air inlet valves for use on transportable tanks with a minimum working pressure greater than 50 kPa for the transport of dangerous goods by road and rail.
It is applicable to equipment for use on tanks with gravity and/or pressure discharge.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for footvalves for use on transportable tanks with a minimum working pressure greater than 50 kPa for the transport of dangerous goods by road and rail.
It is applicable to equipment for use on tanks with gravity and/or pressure bottom loading and discharge.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for hinged manhole covers and neckrings with pivoting bolts for use on transportable tanks with a minimum working pressure greater than 50 kPa for the transport of dangerous goods by road and rail.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the minimum requirements for the design and construction of metallic pressure tanks having a maximum working pressure exceeding 50 kPa (0,5 bar), for the transport of dangerous goods by road and rail. This standard includes requirements for openings, closures and structural equipment; it does not cover requirements of service equipment. For road tankers for the transport of LPG see EN 12493. For tanks for the transport of cryogenic liquids see EN 13530 1 and EN 13530 2.
NOTE Design and construction of pressure tanks according to the scope of this standard are primarily subject to the requirements of RID/ADR, 6.8.2.1, 6.8.3.1 and 6.8.5, as relevant. In addition, the relevant requirements of RID/ADR, columns 12 and 13 of Table A to chapter 3.2, 4.3 and 6.8.2.4 shall be met. For the structural equipment subsections 6.8.2.2 and 6.8.3.2 apply, as relevant. The definitions of RID/ADR 1.2.1 are referred to.
- Standard59 pagesEnglish languagesale 10% offe-Library read for1 day
TC - Series of editorial modifications
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
This standard deals with the design and construction of metallic pressure tanks for the transport of dangerous goods, including their openings, closures and structures but excluding service equipment.
- Standard52 pagesEnglish languagesale 10% offe-Library read for1 day