97.130 - Shop fittings
Shop fittings
Ladeneinrichtungen
Amenagement des magasins
Oprema trgovin
General Information
The scope of this European Standard is to define the classification for horizontal closed ice-cream freezers and to specify their requirements and test methods. These appliances are different to supermarket segment freezers, as they work with static air cooling, with a skin evaporator (no evaporator fan) and are used specifically for the storage and display of pre-packed ice-cream. This standard is only applicable to integral type refrigeration systems. This standard is not applicable to remote ...view more
- Standard51 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft52 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the classification for horizontal closed ice-cream freezer with access of the product from the top via transparent or solid lid(s) and specifies their requirements and test methods. The ice-cream freezers defined in this document are different from supermarket segment freezers, as they work with static air cooling, with a skin evaporator (no evaporator fan) and are used specifically for the storage and display of pre-packed ice-cream. This document is only applicable to i...view more
- Standard44 pagesEnglish language
sale 15% off- Standard46 pagesFrench language
sale 15% off- Draft47 pagesFrench language
sale 15% off- Draft45 pagesEnglish language
sale 15% off
IEC 63252:2020 defines methods for the measurement of energy consumption of vending machines, whether or not fitted with refrigerating appliances.
The standard applies (but is not limited) to the following categories of machines:
- Refrigerated closed-fronted can and bottle machines where the products are held in stacks
- Refrigerated glass-fronted can and bottle, confectionery and snack machines
- Refrigerated glass-fronted machines entirely for perishable foodstuffs
- Refrigerated dual-te...view more
- Standard46 pagesEnglish and French language
sale 15% off
- Amendment5 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment5 pagesEnglish language
sale 10% off- e-Library read for1 day
This Standard specifies requirements for the verification of performance including energy consumption of refrigerated storage cabinets and counters for professional use in commercial kitchens, hospitals, canteens, preparation areas of bars, bakeries, gelateria, institutional catering and similar professional areas.
The products covered in this Standard are intended to store foodstuffs. It specifies test conditions and methods for checking that the requirements have been satisfied, as well as cl...view more
- Standard40 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies classification, requirements for the construction, performance and energy consumption testing of gelato scooping cabinets and pozzetto used to sale and/or display artisan and self made gelato. It specifies test conditions and methods for checking that the requirements have been satisfied, their marking and the list of their characteristics to be declared by the manufacturer.
- Standard57 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies classification, requirements for the construction, performance and energy consumption testing of gelato scooping cabinets and pozzetto used to sale and/or display artisan and self made gelato. It specifies test conditions and methods for checking that the requirements have been satisfied, their marking and the list of their characteristics to be declared by the manufacturer.
- Standard57 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 60335-2-89:2019 specifies safety requirements for electrically operated commercial refrigerating appliances and ice-makers that have an incorporated motor-compressor or that are supplied in two units for assembly as a single appliance in accordance with the instructions (split system).
Examples of appliances that are within the scope of this standard are
- refrigerated display and storage cabinets;
- refrigerated trolley cabinets;
- service counters and self-service counters;
- blast ch...view more
- Standard115 pagesEnglish and French language
sale 15% off
This document specifies requirements for the verification of performance and energy consumption of refrigerated storage cabinets and counters for professional use in commercial kitchens, hospitals, canteens, preparation areas of bars, bakeries, gelateria, institutional catering and similar professional areas.
The products covered in this document are intended to store foodstuffs. It specifies test conditions and methods for checking that the requirements have been satisfied, as well as classifi...view more
- Standard40 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies requirements for the verification of performance and energy consumption of refrigerated storage cabinets and counters for professional use in commercial kitchens, hospitals, canteens, preparation areas of bars, bakeries, gelateria, institutional catering and similar professional areas. The products covered in this document are intended to store foodstuffs. It specifies test conditions and methods for checking that the requirements have been satisfied, as well as classific...view more
- Standard33 pagesFrench language
sale 15% off- Standard33 pagesEnglish language
sale 15% off
- Amendment4 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment4 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard provides test or calculation methods to assess thermal insulation performances for customized walk-in cold rooms and components under normal end-use conditions.
The normal end-use conditions of a walk-in cold room are considered to be:
- installation inside an existing building;
- not exposed to external weather conditions;
- internal side of panels subject to temperatures within the indicative range −40 °C ≤ T ≤ 12 °C;
- external side of panels subject to temperature...view more
- Standard53 pagesEnglish language
sale 10% off- e-Library read for1 day
This document provides test or calculation methods to assess thermal insulation performances for customized walk-in cold rooms and components under normal end-use conditions.
The normal end-use conditions of a walk-in cold room are considered to be:
- installation inside an existing building;
- not exposed to external weather conditions;
- internal side of panels subject to temperatures within the indicative range −40 °C ≤ T ≤ 12 °C;
- external side of panels subject to temperatures within ...view more
- Standard53 pagesEnglish language
sale 10% off- e-Library read for1 day
This standard specifies the requirements for the construction, characteristics, performance including energy consumption of blast cabinet for professional used in commercial kitchens, hospitals, canteens, institutional catering and similar professional areas.
The appliances covered by this standard are intended to rapidly cool down hot foodstuffs up to a load capacity of 300 kg.
This standard applies to:
- blast chillers;
- blast freezers;
- multi-use blast chillers/freezers.
The following...view more
- Standard13 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the requirements for the construction, characteristics, performance including energy consumption of blast cabinet for professional used in commercial kitchens, hospitals, canteens, institutional catering and similar professional areas.
The appliances covered by this European Standard are intended to rapidly cool down hot foodstuffs up to a load capacity of 300 kg.
This European Standard applies to:
- blast chillers;
- blast freezers;
- multi-use blast chille...view more
- Standard13 pagesEnglish language
sale 10% off- e-Library read for1 day
D166/049: Extension of DOW approved to read 2021-01-03 (instead of 2020-07-03)
- Amendment9 pagesEnglish language
sale 10% off- e-Library read for1 day
D166/049: Extension of DOW approved to read 2021-01-03 (instead of 2020-07-03)
- Amendment9 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard applies to prefabricated walk-in cold room kits and components. It provides test or calculation methods to assess thermal insulation performances.
Performance characteristics of Walk-in cold rooms are assessed in terms of thermal insulating properties, in order to give a basis on which assessing Energy Consumption related properties of Walk-in cold rooms, and of their components.
Performance Characteristics will be assessed for every single component of the Walk-in cold ...view more
- Standard49 pagesEnglish language
sale 10% off- e-Library read for1 day