Standard Specification for Closed-Cell Cellular Polypropylene (PP) Corrugated Wall Stormwater Collection Chambers

SCOPE
1.1 This specification covers requirements, test methods, materials, and marking for closed-cell cellular polypropylene (PP), open bottom, buried chambers of corrugated wall construction used for collection, detention, and retention of stormwater runoff. Applications include commercial, residential, agricultural, and highway drainage, including installation under parking lots and roadways.  
1.2 Chambers are produced in arch shapes with dimensions based on chamber rise, chamber span, and wall stiffness. Chambers are manufactured with integral feet that provide base support. Perforations to enhance water flow are permitted. Chambers must meet test requirements for arch stiffness, and flattening. Chamber end caps shall be produced of PP or polyethylene (PE) by a suitable manufacturing process provided that all other product requirements in this standard are met.  
1.3 Analysis and experience have shown that the successful performance of this product depends upon the type and depth of bedding and backfill, and care in installation. This specification includes requirements for the manufacturer to provide chamber installation instructions to the purchaser.  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 This standard does not purport to address water quality issues or hydraulic performance requirements associated with its use. It is the responsibility of the user to ensure that appropriate engineering analysis is performed to evaluate the water quality issues and hydraulic performance requirements for each installation.  
1.6 The following safety hazards caveat pertains only to the test method portion, Section 6, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Jan-2020
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F3430-20 - Standard Specification for Closed-Cell Cellular Polypropylene (PP) Corrugated Wall Stormwater Collection Chambers
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:F3430 −20
Standard Specification for
Closed-Cell Cellular Polypropylene (PP) Corrugated Wall
1
Stormwater Collection Chambers
This standard is issued under the fixed designation F3430; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope if any, associated with its use. It is the responsibility of the user
of this standard to establish appropriate safety, health, and
1.1 This specification covers requirements, test methods,
environmental practices and determine the applicability of
materials, and marking for closed-cell cellular polypropylene
regulatory limitations prior to use.
(PP), open bottom, buried chambers of corrugated wall con-
1.7 This international standard was developed in accor-
struction used for collection, detention, and retention of storm-
dance with internationally recognized principles on standard-
water runoff. Applications include commercial, residential,
ization established in the Decision on Principles for the
agricultural, and highway drainage, including installation un-
Development of International Standards, Guides and Recom-
der parking lots and roadways.
mendations issued by the World Trade Organization Technical
1.2 Chambers are produced in arch shapes with dimensions
Barriers to Trade (TBT) Committee.
based on chamber rise, chamber span, and wall stiffness.
Chambersaremanufacturedwithintegralfeetthatprovidebase
2. Referenced Documents
support. Perforations to enhance water flow are permitted.
2
2.1 ASTM Standards:
Chambers must meet test requirements for arch stiffness, and
D256 Test Methods for Determining the Izod Pendulum
flattening. Chamber end caps shall be produced of PP or
Impact Resistance of Plastics
polyethylene (PE) by a suitable manufacturing process pro-
D618 Practice for Conditioning Plastics for Testing
vided that all other product requirements in this standard are
D638 Test Method for Tensile Properties of Plastics
met.
D790 Test Methods for Flexural Properties of Unreinforced
1.3 Analysis and experience have shown that the successful
and Reinforced Plastics and Electrical Insulating Materi-
performance of this product depends upon the type and depth
als
of bedding and backfill, and care in installation. This specifi-
D1600 Terminology forAbbreviatedTerms Relating to Plas-
cation includes requirements for the manufacturer to provide
tics
chamber installation instructions to the purchaser.
D2122 Test Method for Determining Dimensions of Ther-
1.4 The values stated in inch-pound units are to be regarded moplastic Pipe and Fittings
D2412 Test Method for Determination of External Loading
as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only Characteristics of Plastic Pipe by Parallel-Plate Loading
D2990 Test Methods for Tensile, Compressive, and Flexural
and are not considered standard.
Creep and Creep-Rupture of Plastics
1.5 This standard does not purport to address water quality
D3350 Specification for Polyethylene Plastics Pipe and Fit-
issues or hydraulic performance requirements associated with
tings Materials
its use. It is the responsibility of the user to ensure that
D4101 Classification System and Basis for Specification for
appropriate engineering analysis is performed to evaluate the
Polypropylene Injection and Extrusion Materials
water quality issues and hydraulic performance requirements
D6992 Test Method for Accelerated Tensile Creep and
for each installation.
Creep-Rupture of Geosynthetic Materials Based on Time-
1.6 The following safety hazards caveat pertains only to the
Temperature Superposition Using the Stepped Isothermal
test method portion, Section 6, of this specification: This
Method
standard does not purport to address all of the safety concerns,
F412 Terminology Relating to Plastic Piping Systems
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
2
Piping Systems and is the direct responsibility of Subcommittee F17.65 on Land For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Drainage. contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Current edition approved Feb. 1, 2020. Published March 2020. DOI: 10.1520/ Standards volume information, refer to the standard’s Document Summary page on
F3430–20. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.