Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building hardware

This European Standard specifies a method for characterizing the influence on fire performance of items of building hardware for incorporation into hinged or pivoted vertically installed fire door assemblies (having either one or two leaves) or vertically installed openable window assemblies, of known fire resistance of up to and including 240 minutes integrity (and where relevant insulation) in accordance with EN 1634-1. It applies to the testing of building hardware for use on hinged and pivoted doors and openable windows which include framed glazed doors and windows, but not glass doors. It does not include a test for durability or other performance characteristics, which should be evaluated according to the product standard for the item of building hardware or as given in EN 14600.
The method is suitable for characterizing building hardware for use on non-metallic door or window assemblies consisting of cellulosic materials or mineral boards faced with cellulosic materials, hung in either cellulosic, mineral cored or metal frames: or conventional steel doors made from sheet steel, not more than 1,5 mm thick, hung in steel frames (steel doors include doors filled with mineral board or mineral fibre cores but not steel clad timber/cellulosic doors). The size of these assemblies can be up to that given in the field of direct application for the door leaf construction concerned.
This method is not directly appropriate for evaluating building hardware for use on glass or glazed doors with decorative perimeter framing. The appropriateness of this method of test can be established by reference to the flow chart given in Annex A.
This European Standard does not constitute a fire resistance test for a leaf, window, frame, intumescent seal, or anything other than the selected item of building hardware. The use of any resulting field of direct application is restricted to leaf and frame constructions which have been successfully tested to EN 1634-1.

Feuerwiderstandsprüfungen und Rauchschutzprüfungen für Türen, Tore, Abschlüsse, Fenster und Baubeschläge - Teil 2: Charakterisierungsprüfungen zum Feuerwiderstand von Baubeschlägen

Diese Europäische Norm legt ein Verfahren fest, um den Einfluss von Beschlägen, die zum Einbau an ein- und zweiflügeligen vertikalen Drehflügeltüren und -fenster vorgesehen sind, auf die Leistungs¬fähigkeit von Feuerschutzabschlüssen bei Brandbeanspruchung zu ermitteln. Es handelt sich um Anlagen mit bekannter Feuerwiderstandsdauer bis einschließlich 240 min zur Sicherstellung des Raumabschlusses (und falls zutreffend der Wärmedämmung) nach EN 1634-1. Diese Norm findet Anwendung bei der Prüfung von Beschlägen, die für den Einsatz an drehbaren Türen, die teilweise verglast sein können, und Fenstern vorgesehen sind. Diese Norm gilt nicht für Glastüren. Eine Prüfung der Dauerfunktionstüchtigkeit oder andere leistungsbezogene Eigenschaften sollte entsprechendgemäß der Produktnorm für den Beschlag bzw. gemäßentsprechend den Angaben in EN 14600 durchgeführt werden.
Das Verfahren ist zur Charakterisierung von Beschlägen geeignet, die für den Einsatz an nicht metallischen Tür- oder Fensteranlagen aus Holzwerkstoffen oder Mineralstoffplatten mit Beschichtung aus Holzwerkstoffen vorgesehen sind, wobei die Zargen entweder aus Holzwerkstoffen, mineralstoffhaltiger Kernbauweise oder Metall sind oder es wird für gewöhnliche Stahltüren aus Blech mit einer maximalen Dicke von 1,5 mm zusammen mit Stahlrahmen verwendet (Stahltüren umfassen Türen, die mit Mineralplatten bzw. Mineralfaserkernen gefüllt sind, nicht jedoch mit Stahl bekleidete Holztüren bzw. Türen aus Holzwerkstoffen, die mit Stahl bekleidet sind.). Die Größe dieser Anlagen kann bis zu der Größe, die für den direkten Anwendungsbereich für die betreffende Türflügelkonstruktion angegeben ist, reichen.
Dieses Verfahren ist nicht direkt anwendbar für die Beurteilung von Beschlägen für Glastüren oder verglaste Türen mit dekorativem umlaufendem Rahmen. Die Eignung dieses Prüfverfahrens kann mit Hilfe des Ablaufdiagramms in Anhang A festgestellt werden.

Essai de résistance au feu et d'étanchéité aux fumées des portes, fermetures, fenêtres et éléments de quincailleries - Partie 2: Caractérisation de la résistance au feu pour les éléments de quincaillerie

Preskusi požarne odpornosti vrat in zapornih elementov, oken, ki se odpirajo, in elementov gradbenega okovja - 2. del: Preskus požarne odpornosti elementov gradbenega okovja

General Information

Status
Published
Publication Date
11-Nov-2008
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
22-Nov-2018

Buy Standard

Standard
EN 1634-2:2009
English language
60 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Preskusi požarne odpornosti vrat in zapornih elementov, oken, ki se odpirajo, in elementov gradbenega okovja - 2. del: Preskus požarne odpornosti elementov gradbenega okovjaFeuerwiderstands- und Rauchleckageprüfungen für Tür- und Abschlusseinrichtungen, Fenster sowie Beschläge - Teil 2: Charakterisierungsprüfungen zum Feuerwiderstand von BeschlägenFire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building hardware91.190Stavbna opremaBuilding accessories91.060.50Vrata in oknaDoors and windows13.220.50Požarna odpornost gradbenih materialov in elementovFire-resistance of building materials and elementsICS:Ta slovenski standard je istoveten z:EN 1634-2:2008SIST EN 1634-2:2009en,de01-marec-2009SIST EN 1634-2:2009SLOVENSKI
STANDARD



SIST EN 1634-2:2009



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 1634-2November 2008ICS 13.220.50; 91.060.50 English VersionFire resistance and smoke control tests for door, shutter andopenable window assemblies and elements of building hardware- Part 2: Fire resistance characterisation test for elements ofbuilding hardwareFeuerwiderstands- und Rauchleckageprüfungen für Tür-und Abschlusseinrichtungen, Fenster sowie Beschläge -Teil 2: Charakterisierungsprüfungen zum Feuerwiderstandvon BeschlägenThis European Standard was approved by CEN on 13 September 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2008 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 1634-2:2008: ESIST EN 1634-2:2009



EN 1634-2:2008 (E) 2 Contents Page Foreword.6 Introduction.7 1 Scope.9 2 Normative references.9 3 Terms and definitions.10 4 Test conditions.11 4.1 Ambient conditions within laboratory.11 4.2 Heating conditions.12 4.3 Pressure conditions.12 4.3.1 General.12 4.3.2 Pressure conditions for testing single axis hinges on side hung doors or openable windows.12 4.3.3 Pressure conditions for testing securing devices.12 4.3.4 Pressure conditions for testing non-edge mounted items of building hardware.13 4.3.5 Pressure conditions for testing surface mounted overhead closing devices.13 4.3.
...