Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 20: Smoke control for hinged and pivoted steel, timber and metal framed glazed doorsets

This Part of (pr/Fpr)EN 15269, which should be read in conjunction with FprEN 15269-1, covers hinged and pivoted steel doorsets, hinged and pivoted timber doorsets (including timber framed glazed doorsets) and hinged and pivoted metal framed glazed doorsets of single or double-leaf construction.
The document prescribes the methodology for extending the application of test results obtained from test(s) conducted in accordance with EN 1634-3.
NOTE    It is anticipated that the above scope will be extended to cover other product types when the relevant test information and expertise become available.
Subject to the completion of the appropriate test or tests, the extended application may cover Ambient Temperature Smoke Control (Sa) and Medium Temperature Smoke Control (Sm) classifications and all or some of the following variations:
- glazed elements, louvres and/or vents;
- side, transom or overpanels;
- items of building hardware;
- decorative finishes;
- intumescent, smoke, draught or acoustic seals;
- alternative supporting construction(s).

Erweiterter Anwendungsbereich von Prüfergebnissen zur Feuerwiderstandsfähigkeit und/oder Rauchdichtigkeit von Türen, Toren und Fenstern einschließlich ihrer Baubeschläge - Teil 20: Rauchdichtigkeit von Drehflügeltüren und -toren aus Holz und Stahl sowie Metall- und Holzrahmentüren mit Verglasungen

Dieser Teil der Normenreihe EN 15269 gilt in Verbindung mit prEN 15269 1 und behandelt einflügelige und zweiflügelige Drehflügeltüren aus Holz und Stahl sowie einflügelige und zweiflügelige Metall- und Holzrahmen-Drehflügeltüren mit Verglasungen.
Es wird die Methodologie zur Erweiterung der Anwendung von Prüferergebnissen aus Prüfungen nach EN 1634 3 beschrieben.
ANMERKUNG   Der Anwendungsbereich wird voraussichtlich erweitert, um weitere Produkttypen zu berücksichtigen, wenn die maßgebenden Prüfergebnisse und Fachkenntnisse vorliegen.
In Abhängigkeit von der Durchführung der entsprechenden Prüfung oder Prüfungen kann der erweiterte Anwendungsbereich die Klassifizierungen der Rauchdichtheit bei Umgebungstemperatur (Sa) und die Rauch-dichtheit bei erhöhter Temperatur (Sm) sowie einige oder alle der folgenden Bereiche abdecken:
-   verglaste Bauteile, Lüftungsgitter und/oder Ventilationsöffnungen;
-   Seitenteile, Oberteile oder obere Türblenden;
-   Türbeschläge;
-   dekorative Beschichtungen;
-   dämmschichtbildende Dichtungen, sowie Dichtungen zur Behinderung von Rauchdurchtritt (Rauchschutz-dichtungen), Durchzug oder der Schallübertragung (Schallschutzdichtungen);
-   alternative Tragkonstruktionen.

Application étendue des résultats d'essais en matière de résistance au feu et/ou d'étanchéité à la fumée des blocs-portes, blocs-fermetures et ouvrants de fenêtre, y compris leurs éléments de quincaillerie intégrés - Partie 20 : Étanchéité à la fumée des blocs-portes battants et pivotants en acier, en bois et vitrés à ossature métallique

La présente partie du (pr/Fpr)EN 15269, qu’il convient de lire en conjonction avec le prEN 15269-1, traite des blocs-portes battants et pivotants en acier, des blocs-portes battants et pivotants en bois (y compris les blocs-portes vitrés à ossature en bois) et des blocs-portes vitrés battants et pivotants à ossature métallique, à simple ou à double vantail.
Ce document prescrit une méthode permettant d’étendre l’application des résultats de l’essai ou des essais effectués conformément à l’EN 1634-3.
NOTE   Il est prévu d’élargir le domaine d’application ci-dessus afin de couvrir d’autres types de produits lorsque les informations d’essai pertinentes et l’expérience requises seront disponibles.
En fonction de l’exécution du ou des essais appropriés, l’application étendue peut couvrir les classifications d’étanchéité à la fumée à température ambiante (Sa) et d’étanchéité à la fumée à température moyenne (Sm), ainsi que la totalité, ou certaines, des variations suivantes :
   éléments vitrés, jalousies et/ou évents ;
   panneaux latéraux, panneaux d’imposte avec ou sans traverse intermédiaire ;
   éléments de quincaillerie de bâtiment ;
   finitions décoratives ;
   joints intumescents, d’étanchéité à la fumée, à l’air, ou acoustiques ;
   autre(s) construction(s) support.

Razširjena uporaba rezultatov preskusov požarne odpornosti in/ali dimotesnosti za vrata, zapore in okna, ki se odpirajo, vključno z njihovim okovjem - 20. del: Požarna odpornost lesenih in jeklenih vrat s tečaji

General Information

Status
Withdrawn
Publication Date
22-Sep-2009
Withdrawal Date
22-Sep-2020
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
23-Sep-2020

Relations

Buy Standard

Standard
EN 15269-20:2009
English language
40 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Erweiterter Anwendungsbereich von Prüfergebnissen zur Feuerwiderstandsfähigkeit und Rauchdichte von Türen, Toren und Verblendverschlüssen - Teil 20: Rauchdichte von Drehtüren aus Holz und Stahl sowie VerblendverschlüssenApplication élargie des résultats d'essai en matière d'étanchéité à la fumée des blocs-portes et des blocs-fermetures - Partie 20: Blocs-portes pivotants ou battants en bois et en acierExtended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 20: Smoke control for hinged and pivoted steel, timber and metal framed glazed doorsets91.060.50Vrata in oknaDoors and windows13.220.50Požarna odpornost gradbenih materialov in elementovFire-resistance of building materials and elementsICS:Ta slovenski standard je istoveten z:EN 15269-20:2009SIST EN 15269-20:2009en,de01-december-2009SIST EN 15269-20:2009SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 15269-20
September 2009 ICS 13.220.50; 91.060.50 English Version
Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 20: Smoke control for hinged and pivoted steel, timber and metalframed glazed doorsets
Application étendue des résultats d'essais en matière de résistance au feu et/ou d'étanchéité à la fumée des blocs-portes, blocs-fermetures et ouvrants de fenêtre, y compris leurs éléments de quincaillerie intégrés - Partie 20 : Étanchéité à la fumée des blocs-portes battants et pivotants en acier, en bois et vitrés à ossature métallique
Erweiterter Anwendungsbereich von Prüfergebnissen zur Feuerwiderstandsfähigkeit und/oder Rauchdichtigkeit von Türen, Toren und Fenstern einschließlich ihrer Baubeschläge - Teil 20: Rauchdichtigkeit von Drehflügeltüren und -toren aus Holz und Stahl sowie Metall-und Holzrahmentüren mit Verglasungen This European Standard was approved by CEN on 1 August 2009.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15269-20:2009: ESIST EN 15269-20:2009

 Part 5: Fire resistance of hinged and pivoted, metal framed, glazed doorsets and openable windows  Part 6: Fire resistance of sliding timber doorsets  Part 7: Fire resistance of sliding steel doorsets  Part 8: Fire resistance of horizontally folding timber doorsets  Part 9: Fire resistance of horizontally folding steel doorsets  Part 10: Fire resistance of steel rolling shutters  Part 11: Fire resistance of operable fabric curtains  Part 20: Smoke control for hinged and pivoted steel, timber and metal framed glazed doorsets This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. SIST EN 15269-20:2009

The "C" classification is complimented by the digits 0 to 5 according to the use category on the basis of details included in the relevant product standards. The effect on the "C" classification following an extended application process is not addressed in this standard. SIST EN 15269-20:2009

The document prescribes the methodology for extending the application of test results obtained from test(s) conducted in accordance with EN 1634-3. NOTE
It is anticipated that the above scope will be extended to cover other product types when the relevant test information and expertise become available. Subject to the completion of the appropriate test or tests, the extended application may cover Ambient Temperature Smoke Control (Sa) and Medium Temperature Smoke Control (Sm) classifications and all or some of the following variations:  glazed elements, louvres and/or vents;  side, transom or overpanels;  items of building hardware;  decorative finishes;  intumescent, smoke, draught or acoustic seals;  alternative supporting construction(s). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1363-1:1999, Fire resistance tests – Part 1: General requirements EN 1634-1:2008, Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware – Part 1: Fire resistance tests for doors, shutters and openable windows EN 1634-2, Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware – Part 2: Fire resistance characterisation test for elements of building hardware
EN 1634-3:2004, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware – Part 3: Smoke control test for door and shutter assemblies
EN 13501-2:2007, Fire classification of construction products and building elements – Part 2: Classification using data from fire resistance tests, excluding ventilation services prEN 15269-1:2009, Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware – Part 1: General Requirements EN ISO 13943:2000, Fire safety – Vocabulary (ISO 13943:2000) SIST EN 15269-20:2009

prEN 15269-1:2009 together with the following apply : 3.1 core material fitted centrally within the thickness of a door leaf which may consist of a single sheet of material or a combination either of sheets of the same material or layers of different materials 4 Determination of the field of extended application
4.1 General 4.1.1 Before there can be any consideration for extended application the doorset shall have been tested and classified in accordance with EN 1634-3 and EN 13501-2 respectively in order to establish a classification for the doorset. 4.1.2 A review of the doorset construction parameters can indicate that one or more characteristics may be improved by a particular parameter variation. All evaluations shall be made on the basis of retaining the classifications obtainable from testing to EN 1634-3, including those lower than the test duration. However, this shall never lead to an increased classification for any specific parameter beyond that achieved during any one test unless specifically identified in the relevant Construction Parameter Variation tables. 4.1.3 All evaluations shall be made on the basis of retaining the classification obtained from testing to EN 1634-3. 4.1.4 If, by following the ensuing procedure, any part of the classification cannot be achieved by extended application rules that part of classification shall be omitted from the subsequent extended application report and classification report. 4.2 Procedure for evaluation 4.2.1 Identify the variations from the original test specimen(s) which are required to be covered by an extended application report. 4.2.2 Locate the variations in the appropriate parameter variation by reference to columns (1) and (2) of Table A.1. 4.2.3 Review the type of classification to be retained from column (3) of Table A.1 and establish from the contents of column (4) of Table A.1 whether any extended application is available without the need for further testing. 4.2.4 Where this is deemed to be possible this can be recorded in the extended application report together with any appropriate restrictions and the stated rules from column (4) in Table A.1. 4.2.5 Where the variations required can only be achieved from additional testing according to column (5), the additional test can be made on a similar specimen type to the original test against which the extended application is sought. Alternatively, column (5) in Table A.1 identifies an option for alternative testing and r
...