EN 442-2:1996/A1:2000
(Amendment)Radiators and convectors - Part 2: Test methods and rating
- BACK
- 20-Jun-2000
- 09-Dec-2014
- 91.140.10
- 305/2011
- 89/106/EEC
- CEN/TC 130
Radiators and convectors - Part 2: Test methods and rating
To add Annex H concerning the om values of a set of master radiators complying with EN 442-2.
Radiatoren und Konvektoren - Teil 2: Prüfverfahren und Leistungsangabe
Radiateurs et convecteurs - Partie 2: Méthodes d'essai et d'évaluation
Ogrevala in konvektorji - 2. del: Preskusne metode in vrednotenje rezultatov - Dopolnilo A1
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2002
Ogrevala in konvektorji - 2. del: Preskusne metode in vrednotenje rezultatov -
Dopolnilo A1
Radiators and convectors - Part 2: Test methods and rating
Radiatoren und Konvektoren - Teil 2: Prüfverfahren und Leistungsangabe
Radiateurs et convecteurs - Partie 2: Méthodes d'essai et d'évaluation
Ta slovenski standard je istoveten z: EN 442-2:1996/A1:2000
ICS:
91.140.10 Sistemi centralnega Central heating systems
ogrevanja
...
This May Also Interest You
The EN 1264 series gives guidelines for surface embedded heating and cooling systems installed in buildings, residential and non-residential (e.g. office, public, commercial and industrial buildings) and focuses on systems installed for the purpose of thermal comfort.
The EN 1264 series gives guidelines for water based heating and cooling systems embedded into the enclosure surfaces of the room to be heated or to be cooled. It also specifies the use of other heating media instead of water, as appropriate.
The EN 1264 series specifies standardized product characteristics by calculation and testing the thermal output of heating for technical specifications and certification. For the design, construction and operation of these systems, see EN 1264-3 and EN 1264-4 for the types A, B, C, D, H, I and J. For the types E, F and G, see the EN ISO 11855 series.
The systems specified in the EN 1264 series are adjoined to the structural base of the enclosure surfaces of the building, mounted directly or with fixing supports. The EN 1264 series does not specify ceiling systems mounted in a suspended ceiling with a designed open air gap between the system and the building structure which allows the thermally induced circulation of the air. The thermal output of these systems can be determined according to the EN 14037 series and EN 14240.
EN 1264-5 specifies the recalculation of values determined in EN 1264-2 for the system in question. It enables the conversion of the calculation and measurement results of EN 1264-2 into results for other surface orientations in the room, i.e. for ceiling and wall heating, as well as for the application as cooling surfaces, i.e. for floor, ceiling and wall cooling. The test results of EN 1264-2 are the basis of all calculation, whether or not the system in question is used for heating or cooling application.
- Standard11 pagesEnglish languagesale 10% offe-Library read for×1 day
- 18-May-2021
- 29-Nov-2021
- 91.140.10
- CEN/TC 130
The EN 1264 series gives guidelines for surface embedded heating and cooling systems installed in buildings, residential and non-residential (e.g. office, public, commercial and industrial buildings) and focuses on systems installed for the purpose of thermal comfort.
The EN 1264 series gives guidelines for water based heating and cooling systems embedded into the enclosure surfaces of the room to be heated or to be cooled. It also specifies the use of other heating media instead of water, as appropriate.
The EN 1264 series specifies standardized product characteristics by calculation and testing the thermal output of heating for technical specifications and certification. For the design, construction and operation of these systems, see EN 1264-3 and EN 1264-4 for the types A, B, C, D, H, I and J. For the types E, F and G, see the EN ISO 11855 series.
The systems specified in the EN 1264 series are adjoined to the structural base of the enclosure surfaces of the building, mounted directly or with fixing supports. The EN 1264 series does not specify ceiling systems mounted in a suspended ceiling with a designed open air gap between the system and the building structure which allows the thermally induced circulation of the air. The thermal output of these systems can be determined according to the EN 14037 series and EN 14240.
EN 1264-2 specifies hot water floor heating systems. The application of EN 1264-5 requires the prior use of EN 1264-2. EN 1264-5 specifies the conversion of the thermal output of floor heating systems determined in EN 1264-2 into the thermal output of heating surfaces embedded in walls and ceilings as well as into the thermal output of cooling surfaces embedded in floors, walls and ceilings.
EN 1264-2 specifies the boundary conditions and the test methods for the determination of the thermal output of hot water floor heating systems as a function of the temperature difference between the heating medium and the room temperature.
The thermal output is tested by a calculation method and by a measurement method. The calculation method is applicable to systems corresponding to the definitions in EN 1264-1 (type A, B, C, D, H, I and J). The measurement method gives guidance for systems not corresponding to these definitions. The calculation method and the measurement method are consistent with each other and provide correlating and adequate test results.
The test results, expressed depending on further parameters, are the standard specific thermal output and the associated standard temperature difference between the heating medium and the room temperature as well as fields of characteristic curves showing the relationship between the specific thermal output and the temperature difference between the heating medium and the room.
- Standard41 pagesEnglish languagesale 10% offe-Library read for×1 day
- 18-May-2021
- 29-Nov-2021
- 91.140.10
- CEN/TC 130
The EN 1264 series gives guidelines for surface embedded heating and cooling systems installed in buildings, residential and non-residential (e.g. office, public, commercial and industrial buildings) and focuses on systems installed for the purpose of thermal comfort.
The EN 1264 series gives guidelines for water based heating and cooling systems embedded into the enclosure surfaces of the room to be heated or to be cooled. It also specifies the use of other heating media instead of water, as appropriate.
The EN 1264 series specifies standardized product characteristics by calculation and testing the thermal output of heating for technical specifications and certification. For the design, construction and operation of these systems, see EN 1264-3 and EN 1264-4 for the types A, B, C, D, H, I and J. For the types E, F and G, see the EN ISO 11855 series.
The systems specified in the EN 1264 series are adjoined to the structural base of the enclosure surfaces of the building, mounted directly or with fixing supports. The EN 1264 series does not specify ceiling systems mounted in a suspended ceiling with a designed open air gap between the system and the building structure which allows the thermally induced circulation of the air. The thermal output of these systems can be determined according to the EN 14037 series and EN 14240.
EN 1264-1 specifies system types and characteristics of water based surface embedded radiant heating and cooling systems.
- Standard30 pagesEnglish languagesale 10% offe-Library read for×1 day
- 18-May-2021
- 29-Nov-2021
- 01.040.91
- 01.075
- 91.140.10
- CEN/TC 130
The EN 1264 series gives guidelines for surface embedded heating and cooling systems installed in buildings, residential and non-residential (e.g. office, public, commercial and industrial buildings) and focuses on systems installed for the purpose of thermal comfort.
The EN 1264 series gives guidelines for water based heating and cooling systems embedded into the enclosure surfaces of the room to be heated or to be cooled. It also specifies the use of other heating media instead of water, as appropriate.
The EN 1264 series specifies standardized product characteristics by calculation and testing the thermal output of heating for technical specifications and certification. For the design, construction and operation of these systems, see EN 1264-3 and EN 1264-4 for the types A, B, C, D, H, I and J. For the types E, F and G, see the EN ISO 11855 series.
The systems specified in the EN 1264 series are adjoined to the structural base of the enclosure surfaces of the building, mounted directly or with fixing supports. The EN 1264 series does not specify ceiling systems mounted in a suspended ceiling with a designed open air gap between the system and the building structure which allows the thermally induced circulation of the air. The thermal output of these systems can be determined according to EN 14037 series and EN 14240.
EN 1264-3 specifies the use in practical engineering of the results coming from EN 1264-2 and EN 1264-5.
For heating systems, physiological limitations are taken into account when specifying the surface temperatures. In the case of floor heating systems the limitations are realized by a design based on the characteristic curves and limit curves determined in accordance with EN 1264-2.
For cooling systems, only a limitation with respect to the dew point is taken into account. In predominating practice, this means that physiological limitations are included as well.
- Standard21 pagesEnglish languagesale 10% offe-Library read for×1 day
- 18-May-2021
- 29-Nov-2021
- 91.140.10
- CEN/TC 130
The EN 1264 series gives guidelines for surface embedded heating and cooling systems installed in buildings, residential and non-residential (e.g. office, public, commercial and industrial buildings) and focuses on systems installed for the purpose of thermal comfort.
The EN 1264 series gives guidelines for water based heating and cooling systems embedded into the enclosure surfaces of the room to be heated or to be cooled. It also specifies the use of other heating media instead of water, as appropriate.
The EN 1264 series specifies standardized product characteristics by calculation and testing the thermal output of heating for technical specifications and certification. For the design, construction and operation of these systems, see EN 1264-3 and EN 1264-4 for the types A, B, C, D, H, I and J. For the types E, F and G, see the EN ISO 11855 series.
The systems specified in The EN 1264 series are adjoined to the structural base of the enclosure surfaces of the building, mounted directly or with fixing supports. The EN 1264 series does not specify ceiling systems mounted in a suspended ceiling with a designed open air gap between the system and the building structure which allows the thermally induced circulation of the air. The thermal output of these systems can be determined according to the EN 14037 series and EN 14240.
EN 1264-4 specifies uniform requirements for the design and the construction of heating and cooling floor, ceiling and wall structures to ensure that the heating/cooling systems are suited to the particular application.
The requirements specified by the EN 1264 series apply only to the components of the heating/cooling systems which are part of the heating/cooling system. EN 1264-4 does not cover other elements which are not part of the heating/cooling system.
- Standard19 pagesEnglish languagesale 10% offe-Library read for×1 day
- 18-May-2021
- 29-Nov-2021
- 91.140.10
- CEN/TC 130
This document specifies definitions, requirements and test methods for thermostatic radiator valves referred to hereafter as thermostatic valves.
This standard applies to two port thermostatic valves with or without pre-setting facility and thermostatic integrated valves with or without pre-setting facility for fitting to radiators in wet central heating installations up to a water temperature of 120 °C and a nominal pressure of PN 10.
This standard further specifies the dimensions, the materials and the connection details of four series of straight and angle pattern thermostatic radiator valves of nominal pressure ≤ PN 10.
This standard can be used as reference in a CEN/CENELEC Certification Mark System on thermostatic radiator valves.
- Standard44 pagesEnglish languagesale 10% offe-Library read for×1 day
- 17-Sep-2019
- 30-Mar-2020
- 91.140.10
- CEN/TC 130
This European Standard describes the test method and the test installation for determining the thermal out-put of pre-fabricated ceiling mounted radiant panels according to the specifications of EN 14037 1:2016, 3.3.1.
- Standard36 pagesEnglish languagesale 10% offe-Library read for×1 day
- 20-Sep-2016
- 91.140.10
- CEN/TC 130
This European Standard describes the procedure to determine the rated thermal output (ΦD) and the mean surface temperature (trp) of pre-fabricated ceiling mounted radiant panels.
Pre-fabricated ceiling mounted radiant panels exchange heat mainly by radiation.
The test methods for determining the thermal output of pre-fabricated ceiling mounted radiant panels, as described in EN 14037 2:2016, give reliable results for comparing different products, but these results un-derstate the output obtained under real operating conditions.
- Standard8 pagesEnglish languagesale 10% offe-Library read for×1 day
- 20-Sep-2016
- 91.140.10
- CEN/TC 130
This European Standard defines the technical specifications and requirements for the definition of the cooling capacity of pre-fabricated ceiling mounted radiant panels according to the specifications of EN 14037 1:2016, 3.3.1. The test according to this standard requires the measurement of the thermal output according to EN 14037 2:2016 of the model.
- Standard16 pagesEnglish languagesale 10% offe-Library read for×1 day
- 20-Sep-2016
- 91.140.10
- 91.140.30
- CEN/TC 130
This European Standard describes the test method and the test installation for determining the thermal output of ceiling mounted heating surfaces according to the specifications of prEN 14037-1:2011, 3.3.2, 3.3.3 and 3.3.4.
This part applies to determine thermal output when chilled ceilings according to EN 14240 are also used for heating.
NOTE Test results according to this part cannot be compared with results according to EN 14037-2 because great discrepancies are given at open ceilings, convective components and heating surfaces without upper insulation.
- Standard21 pagesEnglish languagesale 10% offe-Library read for×1 day