EN ISO 11357-2:2014
(Main)Plastics - Differential scanning calorimetry (DSC) - Part 2: Determination of glass transition temperature and glass transition step height (ISO 11357-2:2013)
Plastics - Differential scanning calorimetry (DSC) - Part 2: Determination of glass transition temperature and glass transition step height (ISO 11357-2:2013)
ISO 11357-2:2013 specifies methods for the determination of the glass transition temperature and the step height related to the glass transition of amorphous and partially crystalline plastics.
Kunststoffe - Dynamische Differenz-Thermoanalyse (DSC) - Teil 2: Bestimmung der Glasübergangstemperatur und Glasübergangsstufenhöhe (ISO 11357-2:2013)
Dieser Teil von ISO 11357 legt Verfahren für die Bestimmung der Glasübergangstemperatur und der Stufenhöhe des Glasübergangs von amorphen und teilkristallinen Kunststoffen fest.
Plastiques - Analyse calorimétrique différentielle (DSC) - Partie 2: Détermination de la température de transition vitreuse et de la hauteur de palier de transition vitreuse (ISO 11357-2:2013)
L'ISO 11357-2:2013 spécifie des méthodes permettant de déterminer la température de transition vitreuse et la hauteur de palier de transition vitreuse associées à la transition vitreuse des plastiques amorphes et semi-cristallins.
Polimerni materiali - Diferenčna dinamična kalorimetrija (DSC) - 2. del: Ugotavljanje točke posteklenitve in višine stopnje prehoda (ISO 11357-2:2013)
Standard EN-ISO 11357-2 določa metode za ugotavljanje točke posteklenitve in višine stopnje prehoda amorfnih in delno kristaliničnih polimernih materialov.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-maj-2014
3ROLPHUQLPDWHULDOL'LIHUHQþQDGLQDPLþQDNDORULPHWULMD'6&GHO
8JRWDYOMDQMHWRþNHSRVWHNOHQLWYHLQYLãLQHVWRSQMHSUHKRGD,62
Plastics - Differential scanning calorimetry (DSC) - Part 2: Determination of glass
transition temperature and glass transition step height (ISO 11357-2:2013)
Kunststoffe - Dynamische Differenz-Thermoanalyse (DSC) - Teil 2: Bestimmung der
Glasübergangstemperatur und Stufenhöhe (ISO 11357-2:2013)
Plastiques - Analyse calorimétrique différentielle (DSC) - Partie 2: Détermination de la
température de transition vitreuse et de la hauteur de palier de transition vitreuse (ISO
11357-2:2013)
Ta slovenski standard je istoveten z: EN ISO 11357-2:2014
ICS:
17.200.10 Toplota. Kalorimetrija Heat. Calorimetry
83.080.01 Polimerni materiali na Plastics in general
splošno
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN ISO 11357-2
NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2014
ICS 83.080.01
English Version
Plastics - Differential scanning calorimetry (DSC) - Part 2:
Determination of glass transition temperature and glass
transition step height (ISO 11357-2:2013)
Plastiques - Analyse calorimétrique différentielle (DSC) - Kunststoffe - Dynamische Differenz-Thermoanalyse (DSC) -
Partie 2: Détermination de la température de transition Teil 2: Bestimmung der Glasübergangstemperatur und
vitreuse et de la hauteur de palier de transition vitreuse Glasübergangsstufenhöhe (ISO 11357-2:2013)
(ISO 11357-2:2013)
This European Standard was approved by CEN on 6 March 2014.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 11357-2:2014 E
worldwide for CEN national Members.
Contents Page
Foreword .3
Foreword
The text of ISO 11357-2:2013 has been prepared by Technical Committee ISO/TC 61 “Plastics” of the
International Organization for Standardization (ISO) and has been taken over as EN ISO 11357-2:2014 by
Technical Committee CEN/TC 249 “Plastics” the secretariat of which is held by NBN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by September 2014, and conflicting national standards shall be
withdrawn at the latest by September 2014.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
Endorsement notice
The text of ISO 11357-2:2013 has been approved by CEN as EN ISO 11357-2:2014 without any modification.
INTERNATIONAL ISO
STANDARD 11357-2
Second edition
2013-05-01
Plastics — Differential scanning
calorimetry (DSC) —
Part 2:
Determination of glass transition
temperature and glass transition step
height
Plastiques — Analyse calorimétrique différentielle (DSC) —
Partie 2: Détermination de la température de transition vitreuse et de
la hauteur de palier de transition vitreuse
Reference number
ISO 11357-2:2013(E)
©
ISO 2013
ISO 11357-2:2013(E)
© ISO 2013
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2013 – All rights reserved
ISO 11357-2:2013(E)
Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 2
5 Apparatus and materials. 2
6 Test specimens. 2
7 Test conditions and specimen conditioning . 2
8 Calibration . 2
9 Procedure. 2
9.1 Setting up the apparatus. 2
9.2 Loading the test specimen into the crucible . 2
9.3 Insertion of crucibles . 2
9.4 Temperature scan . 2
10 Expression of results . 3
10.1 Determination of glass transition temperatures . 3
10.2 Determination of glass transition step height . 5
11 Precision . 5
12 Test report . 5
Bibliography . 6
ISO 11357-2:2013(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International
Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies
casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11357-2 was prepared by Technical Committee ISO/TC 61, Plastics, Subcommittee SC 5, Physical-
chemical properties.
This second edition cancels and replaces the first edition (ISO 11357-2:1999), which has been technically
revised. Significant technical changes are the following:
— deletion of duplicate text contained in ISO 11357-1;
— inclusion of determination of step height;
— description of characteristic glass temperatures moved from 3.3 to 10.1;
— inclusion of additional methods of determination of T based on inflection point and equal-areas
g
calculation.
ISO 11357 consists of the following parts, under the general title Plastics — Differential scanning
calorimetry (DSC):
— Part 1: General principles
— Part 2: Determination of glass transition temperature and glass transition step height
— Part 3: Determination of temperature and enthalpy of melting and crystallization
— Part 4: Determination of specific heat capacity
— Part 5: Determination of characteristic reaction-curve temperatures and times, enthalpy of reaction
and degree of conversion
— Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature
(dynamic OIT)
— Part 7: Determination of crystallization kinetics
iv © ISO 2013 – All rights reserved
INTERNATIONAL STANDARD ISO 11357-2:2013(E)
Plastics — Differential scanning calorimetry (DSC) —
Part 2:
Determination of glass transition temperature and glass
transition step height
WARNING — The use of this part of ISO 11357 may involve hazardous materials, operations, or
equipment. This part of ISO 11357 does not purport to address all of the safety problems associated
with its use. It is the responsibility of the user of this part of ISO 11357 to establish appropriate
health and safety practices and to determine the applicability of regulatory limitations prior to use.
1 Scope
This part of ISO 11357 specifies methods for the determination of the glass transition temperature and
the step height related to the glass transition of amorphous and partially crystalline plastics.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 11357-1, Plastics — Differential scanning calorimetry (DSC) — Part 1: General principles
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 11357-1 and the following apply.
3.1
glass transition
reversible change in an amorphous polymer or in amorphous regions of a partially crystalline polymer
from (or to
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.