EN 14511-3:2011
(Main)Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods
1.1 The scope of EN 14511-1:2011 is applicable.
1.2 This European Standard specifies the test methods for the rating and performance of air conditioners, liquid chilling packages and heat pumps using either air, water or brine as heat transfer media, with electrically driven compressors when used for space heating and cooling.
It also specifies the method of testing and reporting for heat recovery capacities, system reduced capacities and the capacity of individual indoor units of multisplit systems, where applicable.
Luftkonditionierer, Flüssigkeitskühlsätze und Wärmepumpen mit elektrisch angetriebenen Verdichtern für die Raumbeheizung und Kühlung - Teil 3: Prüfverfahren
1.1 Es gilt der Anwendungsbereich von EN 14511-1:2011.
1.2 Diese Europäische Norm legt die Prüfverfahren für die Bemessung und Leistung von Luftkonditionierern,
Flüssigkeitskühlsätzen und Wärmepumpen, die Luft, Wasser oder Sole als Wärmeübertrager nutzen, mit
elektrisch angetriebenen Verdichtern für die Raumbeheizung und/oder Kühlung fest.
Sie legt ferner ein Verfahren fest zur Prüfung und Angabe von Wärmerückgewinnungsleistungen, systemreduzierten
Leistungen sowie der Leistung von Einzelgeräten von Multi-Split-Systemen für die Aufstellung im
Innenraum, soweit zutreffend.
Climatiseurs, groupes refroidisseurs de liquide et pompes à chaleur avec compresseur entraîné par moteur électrique pour le chauffage et la réfrigération des locaux - Partie 3: Méthodes d'essai
1.1 Le domaine d'application de l’EN 14511-1:2011 est applicable.
1.2 La présente Norme internationale spécifie les méthodes d'essai pour la détermination des caractéristiques de performance des climatiseurs, groupes refroidisseurs de liquide et pompes à chaleur utilisant l’air, l’eau ou l’eau glycolée comme fluide caloporteur, avec compresseur entraîné par moteur électrique, lorsqu'ils sont utilisés pour le chauffage et la réfrigération des locaux.
Elle spécifie aussi la méthode d'essai et de rapport pour les puissances calorifiques de récupération, les puissances réduites de système et la puissance individuelle des unités intérieures des systèmes multi-split, le cas échéant.
Klimatske naprave, enote za tekočinsko hlajenje in toplotne črpalke z električnimi kompresorji za segrevanje in hlajenje prostora - 3. del: Preskusne metode
1.1 Velja Obseg prEN 14511-2:2009 velja.
1.2 Ta del prEN 14511 določa preskusne metode za ocenjevanje in delovanje zračno in vodno hlajenih klimatskih naprav, enot za tekočinsko hlajenje, zrak-zrak, voda-zrak, zrak-voda in voda-voda toplotnih črpalk z električnimi kompresorji, kadar se uporabljajo za segrevanje in hlajenje prostora. Prav tako, kjer je primerno, določa metodo preskušanja in poročanja zmogljivosti vračanja toplote, zmanjšanje zmogljivosti sistema in zmogljivost posameznih notranjih enot ali sistemov z več razcepi.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Luftkonditionerer, Flüssigkeitskühlsätze und Wärmepumpen mit elektrisch angetriebenen Verdichtern für die Raumbehezung und Kühlung - Teil 3: PrüfverfahrenClimatiseurs, groupes refroidisseurs de liquide et pompes à chaleur avec compresseur entraîné par moteur électrique pour le chauffage et la réfrigération des locaux - Partie 3: Méthodes d'essaiAir conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods91.140.30VLVWHPLVentilation and air-conditioning27.080Heat pumps23.120QDSUDYHVentilators. Fans. Air-conditionersICS:Ta slovenski standard je istoveten z:EN 14511-3:2011SIST EN 14511-3:2012en,fr01-januar-2012SIST EN 14511-3:2012SLOVENSKI
STANDARDSIST EN 14511-3:2008/AC:2008SIST EN 14511-3:20081DGRPHãþD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14511-3
October 2011 ICS 91.140.30 Supersedes EN 14511-3:2007English Version
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods
Climatiseurs, groupes refroidisseurs de liquide et pompes à chaleur avec compresseur entraîné par moteur électrique pour le chauffage et la réfrigération des locaux - Partie 3: Méthodes d'essai
Luftkonditionierer, Flüssigkeitskühlsätze und Wärmepumpen mit elektrisch angetriebenen Verdichtern für die Raumbeheizung und Kühlung - Teil 3: PrüfverfahrenThis European Standard was approved by CEN on 20 August 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14511-3:2011: ESIST EN 14511-3:2012
Calorimeter test method . 24Annex B (informative)
Indoor air enthalpy test method . 32Annex C (informative)
Heating capacity tests - Flow chart and examples of different test sequences . 34Annex D (informative)
Conformance criteria . 39Annex E (informative)
Symbols used in annexes . 40Annex F (informative)
Test at system reduced capacity . 42Annex G (informative)
Individual unit tests . 43Annex H (normative)
Determination of the liquid pump efficiency . 45Bibliography . 48 SIST EN 14511-3:2012
where PH is the heat capacity, expressed in Watts; q is the volume flow rate, expressed in cubic metres per second; ρ is the density, expressed in kilograms per cubic metre; SIST EN 14511-3:2012
NOTE 2
The enthalpy change ∆H can be directly measured instead of the term (cp x ∆t). For the heating capacity calculation in transient operation, refer to 4.5.3.2. The heating capacity shall be corrected for the heat from the fan or pump: a) If the fan or pump at the indoor heat exchanger is an integral part of the unit, the same power (calculated in 4.1.5.2 or 4.1.6.3) which is excluded from the total power input shall be also subtracted from the heating capacity; b) If the fan or pump at the indoor heat exchanger is not an integral part of the unit, the same power (calculated in 4.1.5.3 or 4.1.6.4) which is included in the effective power input shall be also added to the heating capacity. 4.1.2 Cooling capacity The cooling capacity of air conditioners and of air-to-air or water-to-air heat pumps shall be determined by measurements in a calorimeter room (see Annex A) or by the air enthalpy method (see Annex B). The cooling capacity of air-to-water, water-to-water heat pumps and liquid chilling packages shall be determined in accordance with the direct method at the water or brine heat exchanger, by determination of the volume flow of the heat transfer medium, and the inlet and outlet temperatures, taking into consideration the specific heat capacity and density of the heat transfer medium. The cooling capacity shall be determined using the following formula: tcqPpC∆ρ×××= (2) where PC is the cooling capacity, expressed in watts; q is the volume flow rate, expressed in cubic metres per second; ρ is the density, expressed in kilograms per cubic metre; cp is the specific heat at constant pressure, expressed in joules per kilogram and kelvin; ∆t is the difference between inlet and outlet temperatures, expressed in kelvin. NOTE
1 The mass flow rate can be determined directly instead of the term (q x ρ). NOTE
2 The enthalpy change ∆H can be directly measured instead of the term (cp x ∆t)” The cooling capacity shall be corrected for the heat from the fan or pump: a) If the fan or pump at the evaporator is an integral part of the unit, the same power (calculated in 4.1.5.2 or 4.1.6.3) which is excluded from the total power input is also added to the cooling capacity. b) If the fan or pump at the evaporator is not an integral part of the unit, the same power (calculated in 4.1.5.3 or 4.1.6.4) which is included in the effective power input is also subtracted from the cooling capacity. SIST EN 14511-3:2012
...