Adhesives - Short term method for measuring the emission properties of low-solvent or solvent-free adhesives after application - Part 2: Determination of volatile organic compounds

Migrated from Progress Sheet (TC Comment) (2000-07-10): WIs 150-153 are the result of the splitting of WI 145 (Res BT C 262/1999) ++ (CC/991217)

Klebstoffe - Kurzzeit-Verfahren zum Messen der Emissionseigenschaften von lösemittelarmen oder lösemittelfreien Klebstoffen nach der Applikation - Teil 2: Bestimmung flüchtiger organicher Verbindungen

Diese Europäische Vornorm legt ein Verfahren zur Bestimmung einzelner flüchtiger organischer Verbindungen (VOC - volatile organic compounds) und des Gesamtgehaltes an flüchtigen organischen Verbindungen in der Abluft einer Emissionsprüfkammer nach der Applikation eines Klebstoffes (TVOCENV 13999) fest. Das Verfahren beruht auf der Verwendung eines festen Sorptionsmittels mit anschließender Desorption und gaschromatographischer Analyse. Das Verfahren gilt für die Messung von unpolaren und schwach polaren flüchtigen organischen Verbindungen (VOC).

Adhésifs - Méthode de courte durée de mesurage des propriétés d'émission des adhésifs à faible teneur en solvants ou exempts de solvants après application - Partie 2: Dosage des composés organiques volatils

Lepila - Kratkotrajna metoda za merjenje emisijskih lastnosti lepil z malo topila ali brez njega po uporabi - 2. del: Določevanje organskih hlapnih spojin

General Information

Status
Withdrawn
Publication Date
19-Nov-2002
Withdrawal Date
10-Apr-2007
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
11-Apr-2007
Completion Date
11-Apr-2007

Relations

Buy Standard

Standardization document
ENV 13999-2:2003
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST ENV 13999-2:2003
01-maj-2003
/HSLOD.UDWNRWUDMQDPHWRGD]DPHUMHQMHHPLVLMVNLKODVWQRVWLOHSLO]PDORWRSLODDOL
EUH]QMHJDSRXSRUDELGHO'RORþHYDQMHRUJDQVNLKKODSQLKVSRMLQ
Adhesives - Short term method for measuring the emission properties of low-solvent or
solvent-free adhesives after application - Part 2: Determination of volatile organic
compounds
Klebstoffe - Kurzzeit-Verfahren zum Messen der Emissionseigenschaften von
lösemittelarmen oder lösemittelfreien Klebstoffen nach der Applikation - Teil 2:
Bestimmung flüchtiger organicher Verbindungen
Adhésifs - Méthode de courte durée de mesurage des propriétés d'émission des
adhésifs a faible teneur en solvants ou exempts de solvants apres application - Partie 2:
Dosage des composés organiques volatils
Ta slovenski standard je istoveten z: ENV 13999-2:2002
ICS:
83.180 Lepila Adhesives
SIST ENV 13999-2:2003 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

EUROPEAN PRESTANDARD
ENV 13999-2
PRÉNORME EUROPÉENNE
EUROPÄISCHE VORNORM
November 2002
ICS 83.180
English version
Adhesives - Short term method for measuring the emission
properties of low-solvent or solvent-free adhesives after
application - Part 2: Determination of volatile organic compounds
Adhésifs - Méthode de courte durée de mesurage des Klebstoffe - Kurzzeit-Verfahren zum Messen der
propriétés d'émission des adhésifs à faible teneur en Emissionseigenschaften von lösemittelarmen oder
solvants ou exempts de solvants après application - Partie lösemittelfreien Klebstoffen nach der Applikation - Teil 2:
2: Dosage des composés organiques volatils Bestimmung flüchtiger organicher Verbindungen
This European Prestandard (ENV) was approved by CEN on 16 October 2002 as a prospective standard for provisional application.
The period of validity of this ENV is limited initially to three years. After two years the members of CEN will be requested to submit their
comments, particularly on the question whether the ENV can be converted into a European Standard.
CEN members are required to announce the existence of this ENV in the same way as for an EN and to make the ENV available promptly
at national level in an appropriate form. It is permissible to keep conflicting national standards in force (in parallel to the ENV) until the final
decision about the possible conversion of the ENV into an EN is reached.
CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,
Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2002 CEN All rights of exploitation in any form and by any means reserved Ref. No. ENV 13999-2:2002 E
worldwide for CEN national Members.

---------------------- Page: 2 ----------------------

ENV 13999-2:2002 (E)
Contents
Foreword.3
1 Scope .4
2 Normative references .4
3 Principle.4
4 Safety .4
5 Reagents and materials.5
5.1 Volatile organic compounds for calibration, of gas chromatographic grade. .5
5.2 Methanol, of gas chromatographic grade. .5
5.3 Sorbent material.5
5.4 Carrier gas .5
6 Apparatus .5
6.1 Sorbent tubes.5
6.2 Sorbent tube unions .5
6.3 Syringes.5
6.4 Sampling pump .5
6.5 Tubing .5
6.6 Flow meter calibrator.5
6.7 Gas chromatograph.6
6.8 Thermal desorption apparatus .6
6.9 Injection facility for preparing standards by liquid spiking .6
7 Procedure .6
7.1 Preparation of sampling tubes .6
7.1.1 Preconditioning.6
7.1.2 Conditioning.6
7.1.3 Storage of conditioned sorbent tubes before sampling.6
7.2 Test chamber air sampling .7
7.3 Storage of loaded sampling tubes .7
7.4 Blank tubes.7
7.5 Preparation of calibration blend solutions for liquid spiking .7
7.5.1 Solution containing approximately 10 mg/ml of each liquid component .7
7.5.2 Solution containing approximately 1000 μg/ml of each liquid component .7
7.5.3 Solution containing approximately 100 μg/ml of each liquid component .7
7.5.4 Solution containing approximately 10 μg/ml of each liquid component .7
7.5.5 Stability of calibration blend solutions.8
7.6 Preparation of calibration sorbent tubes spiked with standards .8
7.7 Analysis .8
7.7.1 Desorption .8
7.7.2 Gas chromatographic analysis.8
7.7.3 Calibration .9
8 Identification and calculation .9
8.1 Identification of single VOC's .9
8.1.1 Identification Classes .9
8.2 Concentration of single VOC's in the sampled air .9
8.3 Calculation of TVOC .10
ENV 13999
9 Precision and Bias.10
10 Test report .10
11 Quality control.11
Bibliography .12
2

---------------------- Page: 3 ----------------------

ENV 13999-2:2002 (E)
Foreword
This document ENV 13999-2:2002 has been prepared by Technical Committee CEN/TC 193, "Adhesives", the
secretariat of which is held by AENOR.
This document includes a Bibliography.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to announce this European Prestandard : Austria, Belgium, Czech Republic, Denmark,
Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal,
Spain, Sweden, Switzerland and the United Kingdom.
3

---------------------- Page: 4 ----------------------

ENV 13999-2:2002 (E)
1 Scope
This European Prestandard specifies a method for the determination of single volatile organic compounds (VOC's)
and of the total amount of volatile organic compounds in the exhaust air of an emission test chamber after
application of an adhesive (TVOC ). The method is based on use of a solid sorbent with subsequent
ENV13999
desorption and gas chromatographic analysis. The method is applicable to measurement of non-polar and slightly
polar VOC's.
2 Normative references
This European Prestandard incorporates by dated or undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text, and the publications are listed hereafter. For
dated references, subsequent amendments to or revisions of any of these publications apply to this European
Prestandard only when incorporated in it by amendment or revision. For undated references the latest edition of the
publication referred to applies (including amendments).
EN 1232, Workplace atmospheres - Pumps for personal sampling of chemical agents - Requirements and test
methods.
ENV 13999-1, Adhesives - Short term method for measuring the emission properties of low-solvent or solvent-free
adhesives after application - Part 1: General procedure.
ENV 13419-1, Building products - Determination of the emission of volatile organic compounds - Part 1: Emission
test chamber method.
EN ISO 16017-1:2000, Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds
by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling (ISO 16017-1:2000).
ISO/DIS 16000-6, Indoor air - Part 6: Determination of volatile organic compounds in indoor and chamber air by
active sampling on TENAX TA sorbent, thermal desorption and gas chromatography using MSD/FID.
3 Principle
An emission test chamber as described in ENV 13999-1 or in ENV 13419-1 shall be used.
A sufficient volume of test chamber air is drawn with an appropriate flow through one (or more) sorbent tubes in
series containing a solid sorbent. Volatile organic compounds (VOC's) are retained by the sorbent tube, which is
subsequently analysed in the laboratory. The VOC's are desorbed from the sampling tube and transferred by a flow
of inert carrier gas into a capillary gas chromatograph coupled to a mass spectrometric detector (MS) and to a
flame ionisation detector (FID) or only to a mass spectrometric detector.
4 Safety
This Prestandard does not purport to address all of the safety concerns, if any associated with its use. The user of
this Prestandard should be familiar with common laboratory practice including general safety measures. It is the
responsibility of the user of this Prestandard to establish appropriate safety and health practices and determine the
applicability of regulatory limitations prior to use.
4

---------------------- Page: 5 ----------------------

ENV 13999-2:2002 (E)
5 Reagents and materials
5.1 Volatile organic compounds for calibration, of gas chromatographic grade.
5.2 Methanol, of gas chromatographic grade.
5.3 Sorbent material
1)
For general purpose Tenax TA [1] (poly(2,6-diphenyl-p-phenylene oxide)), particle size (0,18 to 0,25) mm i.e. (60
to 80) mesh shall be used.
1)
For the determination of very volatile carcinogenic organic compounds (e.g. vinylchloride) Chromosorb 106
(polystyrene) or equivalent sorbent materials as described in EN ISO 16017-1 shall be used.
5.4 Carrier gas
Helium, argon or nitrogen with a purity 99,999% or better.
6 Apparatus
6.1 Sorbent tubes
Sorbent tubes, made from stainless steel or glass, that can be filled with at least 200 mg of Tenax TA sorbent (5.3)
are used. For example tubes with 6 mm external diameter, 5 mm internal diameter and 90 mm long fulfil the
requirement and are used in many commercial thermal desorbing devices.
NOTE It is recommended to use unsilanised glass wool or other suitable mechanism, e.g. stainless steel frit to retain the
sorbent in the tube and metal screw caps and polytetrafluoroethylene (PTFE) ferrules for closing the sorbent tube.
1)
Fill Chromosorb or equivalent tubes as described in EN ISO 16017-1.
6.2 Sorbent tube unions
Two sorbent tubes may be connected in series during sampling with metal screw cap couplings with PTFE ferrules.
6.3 Syringes
A precision 10 μl liquid syringe readable to 0,1 μl.
6.4 Sampling pump
The pump shall fulfil the requirements of EN 1232 or equivalent.
6.5 Tubing
PE (polythene) or PTFE tubing of appropriate diameter to ensure a leak-proof fit to both pump and sample tube.
Sampling tubes shall not be used with plastic tubing other than PTFE upstream of the sorbent to avoid interference
from contaminants.
6.6 Flow meter calibrator
Bubble meter or other appropriate suitable device for gas flow calibration.

1) Chromosorb 106 and Tenax TA are an example of suitable products available commercially. This information is given for
the convenience of users of this European Prestandard and does not constitute an endorsement by CEN of this product.
5

---------------------- Page: 6 ----------------------

ENV 13999-2:2002 (E)
6.7 Gas chromatograph
A capillary gas chromatograph coupled to a mass spectrometric detector and to a flame ionisation detector or only
to a mass spectrometric detector shall be used in accordance with EN ISO 16017-1.
6.8 Thermal desorption apparatus
Apparatus for two-stage thermal desorption of sorbent tubes and transfer of desorbed vapours via an inert gas flow
into a gas chromatograph is required. A typical apparatus contains a mechanism for holding the tubes to be
desorbed whilst they are heated and purged simultaneously with inert carrier gas. The desorption temperature and
time is adjustable, as is the carrier gas flow rate. The apparatus may also incorporate additional features, such as
autom
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.