Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems - Current transformers

This EN 50152-3-2 is applicable to new current transformers which are  for indoor or outdoor fixed installations in tractions systems, and  operated with an a.c. line voltage and frequency as specified in EN 50163. NOTE 1 EN 50163 specifies the a.c. traction systems 15 kV 16,7 Hz and 25 kV 50 Hz. As rails of a.c. traction systems are connected to earth and included in the return current path all phase to earth voltages will be within the tolerances as specified in EN 50163. Nevertheless phase to phase voltages may be higher e.g. in autotransformer systems. Current transformers are mainly used with  measurement instruments,  protective devices. This EN 50152-3-2 shall also be applied to current transformers other than inductive types as far as reasonably possible. Requirements of this EN 50152-3-2 prevail. NOTE 2 Combined current and voltage transformers are typically not used in fixed installations.

Bahnanwendungen - Ortsfeste Anlagen - Besondere Anforderungen an Wechselstrom-Schalteinrichtungen - Teil 3-2: Mess-, Steuerungs- und Schutzeinrichtungen für Wechselstrom-Bahnanlagen - Stromwandler

EN 50152-3-2 gilt für neue Stromwandler, die für - für die Verwendung in ortsfesten Innenraum- oder Freiluftanlagen in Bahnenergieversorgungssystemen vorgesehen sind und - mit einer Fahrleitungswechselspannung und -frequenz entsprechend EN 50163 betrieben werden. ANMERKUNG 1 EN 50163 benennt für Bahnen die Wechselspannungssysteme 15 kV 16,7 Hz und 25 kV 50 Hz. ANMERKUNG 2 Da bei Wechselspannungsbahnen die Gleise üblicherweise mit dem Erdpotential verbunden und Teil des Rückstromkreises sind, unterliegen alle Außenleiter-Erde-Spannungen der in EN 50163 festgelegten Grenzwerte. Dennoch sind die Spannungen zwischen den Leitern manchmal höher, z. B. in Autotransformator-Systemen. Stromwandler werden hauptsächlich verwendet mit: - Messgeräten, - Schutzeinrichtungen. EN 50152-3-2 gilt auch für Stromwandler mit vom induktiven Messverfahren abweichender Bauart, soweit dies sinnvoll möglich ist. Die Anforderungen dieser EN 50152-3-2 haben Vorrang. ANMERKUNG 3 Kombinierte Strom- und Spannungswandler werden üblicherweise nicht in ortsfesten Anlagen von Bahnnetzen verwendet.

Applications ferroviaires - Installations fixes - Spécifications particulières pour appareillage à courant alternatif - Partie 3-2: Dispositifs de mesure, de commande et de protection pour usage spécifique dans les systèmes de traction à courant alternatif - Transformateurs de courant

La présente norme EN 50152-3-2 s’applique aux nouveaux transformateurs de courant qui sont : - destinés aux installations fixes intérieures ou extérieures dans les systèmes de traction, et - exploités à la tension et à la fréquence d’une ligne à courant alternatif, comme spécifié dans l'EN 50163. NOTE 1 L'EN 50163 spécifie les réseaux de traction à courant alternatif 15 kV 16,7 Hz et 25 kV 50 Hz. NOTE 2 Dans la mesure où les rails des systèmes de traction à courant alternatif sont généralement reliés à la terre et inclus dans le chemin du courant de retour, toutes les tensions phase-terre sont soumises aux limites indiquées dans l'EN 50163. Néanmoins, les tensions entre conducteurs sont parfois plus élevées, dans les systèmes d'autotransformateurs, par exemple. Les transformateurs de courant sont principalement utilisés avec : - des appareils de mesure, - des dispositifs de protection. La présente norme EN 50152-3-2 s'applique également à des transformateurs de courant autres que ceux de type inductif, autant qu'il est raisonnablement possible. Les exigences de la présente norme EN 50152-3-2 sont prioritaires. NOTE 3 Les transformateurs de courant et de tension combinés ne sont généralement pas utilisés dans les installations fixes des systèmes de traction.

Železniške naprave - Stabilne naprave električne vleke - Posebne zahteve za stikalne naprave za izmenični tok - 3-2. del: Merilne, krmilne in zaščitne naprave za izključno uporabo v izmeničnih vlečnih sistemih - Tokovni transformatorji

Ta standard EN 50152-3-2 se uporablja za nove tokovne transformatorje, ki se
uporabljajo za notranje ali zunanje nameščene naprave v vlečnih sistemih in
uporabljajo z izmenično napetostjo in frekvenco, kot je navedeno v standardu EN 50163.
OPOMBA 1: Standard EN 50163 določa vlečne sisteme z izmenično napetostjo 15 kV pri 16,7 Hz in 25 kV pri 50 Hz.
Ker so tiri vlečnih sistemov z izmeničnim tokom ozemljeni in vključeni v pot povratnega toka, bodo vsi vodniki do ozemljitve v mejah toka, ki so določene v standardu EN 50163. Kljub temu so lahko napetosti med vodniki višje kot na primer v sistemih z avtotransformatorji.
Tokovni transformatorji se uporabljajo predvsem z
merilnimi instrumenti,
zaščitnimi napravami.
Ta standard EN 50152-3-2 se uporablja tudi za tokovne transformatorje, ki niso induktivni, v smiselno mogočem obsegu. Prednost imajo zahteve tega standarda EN 50152-3-2.
OPOMBA 2: Kombinacije tokovnih in napetostnih transformatorjev se običajno ne uporabljajo v stabilnih napravah električne vleke.

General Information

Status
Published
Publication Date
09-Jun-2016
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
23-Nov-2022

Relations

Buy Standard

Standard
EN 50152-3-2:2017
English language
11 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 50152-3-2:2017
01-april-2017
1DGRPHãþD
SIST EN 50152-3-2:2002
äHOH]QLãNHQDSUDYH6WDELOQHQDSUDYHHOHNWULþQHYOHNH3RVHEQH]DKWHYH]D
VWLNDOQHQDSUDYH]DL]PHQLþQLWRNGHO0HULOQHNUPLOQHLQ]DãþLWQHQDSUDYH]D
L]NOMXþQRXSRUDERYL]PHQLþQLKYOHþQLKVLVWHPLK7RNRYQLWUDQVIRUPDWRUML
Railway applications - Fixed installations - Particular requirements for a.c. switchgear -
Part 3-2: Measurement, control and protection devices for specific use in a.c. traction
systems - Current transformers
Bahnanwendungen - Ortsfeste Anlagen - Besondere Anforderungen an Wechselstrom-
Schalteinrichtungen - Teil 3-2: Meß-, Steuerungs- und Schutzeinrichtungen für
Wechselstrom-Bahnanlagen - Einphasen-Stromwandler
Applications ferroviaires - Installations fixes - Exigences particulières pour appareillage à
courant alternatif - Partie 3-2: Dispositifs de mesure, de commande et de protection pour
usage spécifique dans les systèmes de traction à courant alternatif - Transformateurs de
courant monophasés
Ta slovenski standard je istoveten z: EN 50152-3-2:2016
ICS:
29.130.99 Druge stikalne in krmilne Other switchgear and
naprave controlgear
29.280 (OHNWULþQDYOHþQDRSUHPD Electric traction equipment
SIST EN 50152-3-2:2017 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 50152-3-2:2017

---------------------- Page: 2 ----------------------

SIST EN 50152-3-2:2017

EUROPEAN STANDARD EN 50152-3-2

NORME EUROPÉENNE

EUROPÄISCHE NORM
June 2016
ICS 29.130.20; 29.280 Supersedes EN 50152-3-2:2001
English Version
Railway applications - Fixed installations - Particular
requirements for a.c. switchgear - Part 3-2: Measurement,
control and protection devices for specific use in a.c. traction
systems - Current transformers
Applications ferroviaires - Installations fixes - Spécifications Bahnanwendungen - Ortsfeste Anlagen - Besondere
particulières pour appareillage à courant alternatif - Partie Anforderungen an Wechselstrom-Schalteinrichtungen - Teil
3-2: Dispositifs de mesure, de commande et de protection 3-2: Mess-, Steuerungs- und Schutzeinrichtungen für
pour usage spécifique dans les systèmes de traction à Wechselstrom-Bahnanlagen - Stromwandler
courant alternatif - Transformateurs de courant
This European Standard was approved by CENELEC on 2016-04-25. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.



European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 50152-3-2:2016 E

---------------------- Page: 3 ----------------------

SIST EN 50152-3-2:2017
EN 50152-3-2:2016
Contents Page
European foreword . 4
1 Scope . 6
2 Normative references . 6
3 Terms, definitions and abbreviations . 6
3.1 Terms and definitions . 6
3.2 Abbreviations . 7
4 Service co
...