EN IEC 60622:2026
(Main)Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable cells and batteries for use in industrial applications.
- Status
- Published
- Publication Date
- 12-Nov-2026
- Technical Committee
- CLC/TC 21X - Secondary cells and batteries
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 13-Nov-2026
- Due Date
- 25-Sep-2026
- Completion Date
- 25-Sep-2026
EN IEC 60622:2026 is a CLC standard for sealed nickel-cadmium (NiCd) prismatic rechargeable cells and the battery systems built from them for industrial applications. It specifies how these cells and batteries are designated, marked, measured, tested and documented so manufacturers, system integrators and users can compare performance and verify fitness for service.
What does EN IEC 60622:2026 specify?
EN IEC 60622:2026 specifies the marking, designation, dimensions, tests and requirements for sealed nickel-cadmium prismatic secondary single cells, and the body of the document extends that framework to battery-level requirements for industrial battery systems.
In Clause 1, prismatic means cells with rectangular sides and base. The document also gives precedence to any IEC standard for a special application when that standard conflicts with EN IEC 60622:2026, which matters when the cells are used in a narrower sector with its own test conditions.
| Annex | What it covers |
|---|---|
| Annex A | CCCV charge methodology |
| Annex B | NiCd load profile verification documentation |
| Annex C | Battery structure information |
| Annex D | Declaration of a representative cell model range |
The main body is organized into clauses on scope, normative references, terms, measurement tolerances, designation and marking, dimensions, electrical tests, mechanical tests, physical appearance, battery-level requirements, performance requirements, and conditions for approval and acceptance.
What are the key requirements of EN IEC 60622:2026?
EN IEC 60622:2026 sets out the identification, performance, safety and approval rules that manufacturers and test houses use to characterize sealed NiCd prismatic cells and battery systems.
Designation and marking
Clause 5 defines how cells are named and marked. The mandatory cell designation starts with KC and then a discharge-rate letter - L, M, H or X - followed by the rated capacity in ampere-hours. Optional markings identify container material, tested temperature range, CCCV charging, rapid charge and high cycling capability, so users can immediately see the tested operating profile.
Clause 5 also requires durable marking on each cell or monobloc with the cell type, the manufacturer or supplier identification and a positive-terminal marking. In practice, that gives traceability on the product and helps installers connect batteries correctly.
Measurement and size control
Clause 4 limits measurement uncertainty for voltage, current, temperature, time and capacity, and requires the instrumentation details to be included in reports. Clause 6 then gives preferred dimensions for sealed NiCd prismatic cells in steel and plastic containers, with measurement tolerances for width and length.
This matters because test results and acceptance decisions depend on consistent measurements, and dimensional control affects fit, packaging and interchangeability.
Electrical characterization and charge methods
Clause 7 defines the test charging procedure and allows either constant-current charging or CCCV (constant current constant voltage) charging, selected by the manufacturer. The standard also defines how rapid charge current is selected and documented.
For performance testing, the document requires discharge characterization at 20 °C and also at +5 °C and -18 °C, with optional characterization at other low and high temperatures. That lets buyers compare cells under the temperatures that matter for their duty cycle.
Performance and ageing tests
Clause 7 includes tests for high-rate current, internal DC resistance, pulse power, constant power, charge retention, endurance, permanent charge endurance, overcharge, safety device operation, gas leakage and storage. Several of these tests are linked to state of charge points used to follow ageing over the life of the cell.
In practice, these tests show how the cell behaves under short high-current events, repeated cycling, storage and long-term float or standby service. Clause 7 also defines fade calculations for capacity, resistance, pulse power, constant power and round-trip efficiency, so ageing can be tracked against the manufacturer’s claims.
Battery-level requirements and sizing
Clause 10 defines the battery system as more than cells alone: it can include trays, crates, modules, electronics and other components needed for safety and durability, such as BTMS (Battery Thermal Management System). It also defines classes of usage for repetitive cycling or on-demand service in mobile and stationary equipment.
Clause 11 then sets the design-energy and design-power methodology. The battery system manufacturer and the end user or system integrator must define the load profile, temperature range, voltage window, ageing factor, reserve margin and the expected service life. This is the part the buyer uses to confirm the battery is sized for the actual application, not just for a nominal rating.
Approval and acceptance
Clause 12 defines type approval and batch acceptance. Type approval uses grouped sample testing across marking, dimensions, performance, ageing, overcharge, safety device operation, gas leakage, storage and appearance, while batch acceptance focuses on delivery inspection for individual cells.
That matters because it separates design qualification from incoming or delivery checks. It helps manufacturers prove the design once, then verify production lots against agreed acceptance levels.
What terms does EN IEC 60622:2026 define?
EN IEC 60622:2026 defines a set of terms that are central to design, testing and battery-system sizing.
- sealed cell - a cell that stays closed in normal operation and does not release gas or liquid within the manufacturer’s limits.
- battery system - the battery plus the trays, crates, modules, electronics and connections needed for safe operation and durability.
- battery module - a group of cells connected in series and/or parallel without protective devices as hardware.
- cumulated requested service (CRS) - the total service demanded by the buyer or end user, expressed as duration or delivered energy.
- State of charge (SOC) - the remaining capacity to be discharged, usually expressed as a percentage of rated capacity.
- State of charge at end of life - the remaining capacity to be discharged at end of life, defined here as 60% of rated capacity under the stated condition.
- CCCV - a charge method with a constant-current stage followed by a constant-voltage stage.
- round-trip efficiency (RTE) - the energy returned on discharge relative to the energy supplied during charge, used for REP applications.
Who uses EN IEC 60622:2026?
EN IEC 60622:2026 is used by cell manufacturers, battery-system manufacturers, system integrators, end users, test laboratories and quality teams working with industrial NiCd batteries.
In practice, they use it to define cell type and capacity markings, select charge methods, size battery systems, document load profiles, run qualification tests, set acceptance criteria and compare cells for mobile or stationary equipment. It is relevant for applications such as forklift trucks, rail, marine, telecom and other fixed installations, and similar industrial uses.
What changed in EN IEC 60622:2026 from the previous edition?
EN IEC 60622:2026 is the fourth edition and cancels and replaces the third edition published in 2002. The foreword states that this edition is a technical revision.
The significant technical changes listed are:
- optional characterization of cells designed for very low and/or very high temperature
- optional characterization of cells tested with CCCV charge
- optional characterization of cells designed for rapid charge
- optional characterization of cells designed for high cycling
Which standards are used with EN IEC 60622:2026?
EN IEC 60622:2026 cites the following standards in its normative references and supporting text:
| Standard | What it contributes |
|---|---|
| IEC 60050-482:2004 | Vocabulary for primary and secondary cells and batteries |
| IEC 60051 (all parts) | Direct acting indicating analogue electrical measuring instruments and their accessories |
| IEC 60417 | Graphical symbols, including the positive-terminal symbol used in marking |
| IEC 62485-2:2010 | Safety requirements for secondary batteries and stationary battery installations |
| IEC 61434 | Guide for designation of current in alkaline secondary cell and battery standards, used in the current notation |
| IEC TR 61438 | Guidance on possible safety and health hazards in use of alkaline secondary cells and batteries |
| IEEE 1106 | Context for permanent charge endurance in stationary Ni-Cd service |
What does the EN IEC 60622:2026 document contain?
EN IEC 60622:2026 contains tables, figures, test procedures and worked examples for cell and battery qualification. The figures illustrate cell and battery structures, a prismatic cell example, pulse discharge behavior and charging characteristics, while the tables cover dimensions, tolerances, rapid-charge values, discharge performance at different temperatures, internal resistance currents, cycling endurance and approval sequences.
Annex A gives the CCCV charging method and its charging-characteristic table. Annex B gives the documentation needed to verify a NiCd load profile, including sizing records, operational verification and test reports, which is useful for design validation and application testing.
Annex C provides notation examples for series and parallel battery structures, and Annex D gives a sample declaration for a representative cell model range used in testing.
Relations
- Effective Date
- 09-Jul-2024
- Effective Date
- 27-Oct-2026
- Effective Date
- 27-Oct-2026
- Effective Date
- 17-Nov-2026
- Effective Date
- 17-Nov-2026
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.

UL Solutions
Global safety science company with testing, inspection and certification.
Sponsored listings
Frequently Asked Questions
EN IEC 60622:2026 is a draft published by CLC. Its full title is "Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable cells and batteries for use in industrial applications.". This standard covers: Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable cells and batteries for use in industrial applications.
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable cells and batteries for use in industrial applications.
EN IEC 60622:2026 is classified under the following ICS (International Classification for Standards) categories: 29.220.30 - Alkaline secondary cells and batteries. The ICS classification helps identify the subject area and facilitates finding related standards.
EN IEC 60622:2026 has the following relationships with other standards: It is inter standard links to EN 60622:2003, EN 60417-2:1999, IEC 60050-482:2004, EN 50171:2021, EN 61427-1:2013. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN IEC 60622:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 Terms and definitions
- 3.1.1 sealed cell
- 3.1.2 monobloc battery
- 3.1.3 crate
- 3.1.4 tray
- 3.1.5 ageing factor
- 3.1.6 battery module
- 3.1.7 battery system
- 3.1.8 battery information system
- 3.1.9 end user
- 3.1.10 system integrator
- 3.1.11 manufacturer
- 3.1.12 cumulated requested service
- 3.1.13 nominal voltage
- 3.1.14 discharge voltage
- 3.1.15 rated capacity
- 3.1.16 State of charge
- 3.1.17 State of charge at end of life
- 3.1.18 CCCV charge
- 3.2 Abbreviated terms
- 4 Parameter measurement tolerances
- 5 Designation and marking
- 5.1 Cell designation (mandatory)
- 5.2 Cell designation (optional)
- 5.3 Cell termination
- 5.4 Battery designation
- 5.5 Marking
- 5.6 Safety recommendations
- 6 Dimensions
- 7 Electrical tests
- 7.1 General
- 7.2 Charging procedure for test purposes
- 7.3 Discharge performances
- 3 A for 14 h
- 7.4 Charge retention
- 7.5 Endurance
- 7.6 Permanent charge endurance
- 7.7 Charge acceptance at constant voltage
- 7.8 Vent plug operation
- 7.9 Electrolyte retention test
- 7.10 Storage
- 7.11 Overcharge test
- 7.12 Safety device operation
- 7.13 Gas leakage test
- 8 Mechanical tests
- 9 Physical appearance
- 10 Requirements at battery level
- 10.1 General requirements
- 10.2 Environmental conditions
- 10.3 Operating voltage range of the battery system
- 10.4 Optional additional components to battery system
- 11 Performance requirement for the battery system
- 11.1 Design energy and power calculation methodology
- 11.2 End of life performance
- 12 Conditions for approval and acceptance
- 12.1 Type approval
- 7.4 Charge retention
- 7.11 Overcharge
- 7.12 Safety device operation
- 7.10 Storage
- 12.2 Batch acceptance
- Annex A
- Annex B
- Annex C
- Annex D
- Bibliography
INTRODUCTION The following items were listed in the bibliography but not cited in the text. Please find a suitable place to cite them to justify their inclusion in the bibliography:
IEC 60485, Digital electronic d.c. voltmeters and d.c. electronic analogue-to-digital
convertorsIEC 60485 [1] EC 60051 (all parts), Direct acting indicating analogue electrical measuring instruments and their accessoriesIEC 60051 (all parts) [2]
This publication was withdrawn.
oSIST prEN IEC 60622:2025
IEC 2025
1 Scope
IEC 60622 specifies marking, designation, dimensions, tests and requirements for sealed nickel-cadmium prismatic secondary single cells.
NOTE In this context, "prismatic" refers to cells having rectangular sides and base. When there exists an IEC standard specifying test conditions and requirements for cells used in special applications and which is in conflict with this document, the former takes precedence.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60050-482:2004, International Electrotechnical Vocabulary (IEV) - Part 482: Primary and secondary cells and batteries IEC 60051 (all parts), Direct acting indicating analogue electrical measuring instruments and their accessories IEC 60417, Graphical symbols for use on equipment - 12-month subscription to regularly updated online database comprising all graphical symbols published in IEC 60417 (available from: http://www.graphical-symbols.info/equipment) IEC 62485-2:2010, Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries
3 Terms and definitions
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60050-482:2004 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- IEC Electropedia: available at https://www.electropedia.org/
- ISO Online browsing platform: available at https://www.iso.org/obp
3.1.1 sealed cell
cell which remains closed and does not release either gas or liquid when operated within the limits specified by the manufacturer Note 1 to entry: A sealed cell may be equipped with a vent to prevent a dangerously high internal pressure and is designed to typically operate during its life in its original sealed state. Note 2 to entry: The limits specified by the manufacturer are mainly regarding charge and temperature. Note 3 to entry: A sealed cell does not require addition to the electrolyte. [SOURCE: IEC 60050-482:2004, 482-05-17, modified Note 1& Addition of Note 2 and 3 to entry.]
oSIST prEN IEC 60622:2025
IEC 2025
3.1.2 monobloc battery
battery with multiple separate but electrically connected cell compartments each of which is designed to house an assembly of electrodes, electrolyte, terminals or interconnections and possible separators Note 1 to entry: The cells in a monobloc battery can be connected in series or in parallel. Note 2 to entry: See 5.4.2.
[SOURCE: IEC 60050-482:2004, 482-02-17, modified - Note 2 to entry has been added.]
3.1.3 crate
container with frame walls for holding several cells or batteries Note 1 to entry: See 5.4.2.
[SOURCE: IEC 60050-482:2004/AMD1:2016, 482-05-10, modified - Note 1 to entry has been added.]
3.1.4 tray
container with a base and walls for holding several cells or batteries Note 1 to entry: See 5.4.2.
[SOURCE: IEC 60050-482:2004/AMD1:2016, 482-02-35. modified - battery removed from the title and Note 1 to entry has been added.]
3.1.5 ageing factor
quantitative factor expressing the degradation in the ability of the battery, due to usage, to deliver electrical energy under specified operating conditions such as, but not limited to, operating ambient temperature, cycling considering depth of discharge (DOD), and maintenance practices (applied as per manufacturer's instructions)
3.1.6 battery module
group of cells connected together either in a series and/or parallel configuration without protective devices) Note 1 to entry: NiCd module is not including any hardware (e.g. fuse or electronic board). Note 2 to entry: protective devices (e.g. temperature sensor) are part of the battery system.
3.1.7 battery system
battery system that also includes battery tray(s), battery crate(s), monobloc(s), battery module(s), electronic components and/or equipment and associated electromechanical connections. Any component necessary to obtain the safety and durability of the battery system is included (e.g. battery thermal management system, BTMS) Note 1 to entry: See 5.4.2 and 10.1.
Note 2 to entry: The battery system manufacturer can be the end user or the equipment manufacturer, in case they install e.g. heating/cooling systems, ventilation common to the global equipment but needed for the battery. Note 3 to entry: The battery system performances are derived from cell electrical characterization.
oSIST prEN IEC 60622:2025
IEC 2025
3.1.8 battery information system
electronic system collecting and analyzing battery data to provide additional information, i.e. information not necessary for battery operation Note 1 to entry: Additional information can be information about e.g. condition-based maintenance.
3.1.9 end user
organization which operates the battery system Note 1 to entry: The end user is normally an organization which operates the device equipped with the battery system, unless the responsibility is delegated to a main contractor or consultant.
3.1.10 system integrator
organization which has the technical responsibility of the complete battery system and charging system Note 1 to entry: The system integrator can be the end user or the equipment manufacturer, or none of them.
3.1.11 manufacturer
organization which has the technical responsibility for its scope of supply Note 1 to entry: The manufacturer can be the equipment manufacturer or the system integrator of a battery system, a cell manufacturer, etc. If necessary to explicitly distinguish, "equipment manufacturer", "battery system manufacturer" or "cell manufacturer" is expressed.
3.1.12 cumulated requested service
CRS total amount of service requested by the buyer or the end user, expressed in duration (months or years) or delivered energy in kWh, under e.g representative ambient and operating conditions as expressed Note 1 to entry: Refer to Clause 10 and Clause 11.
3.1.13 nominal voltage
suitable approximate value of the voltage used to designate or identify a cell or a battery Note 1 to entry: The nominal voltage of a vented nickel-cadmium rechargeable single cell is 1,2 V. Note 2 to entry: The nominal voltage of a battery of n series connected cells is equal to n times the nominal voltage of a single cell.
[SOURCE: IEC 60050-482:2004, 482-03-31, modified - Replacement of the words "a battery or an electrochemical system" by "or a battery" and addition of Notes 1 and 2 to entry.]
3.1.14 discharge voltage
<cell or battery> voltage between the terminals of a cell or battery when being discharged [SOURCE: IEC 60050-482:2004, 482-03-28]
3.1.15 rated capacity
capacity value of a cell or battery determined under specified conditions and declared by the manufacturer
oSIST prEN IEC 60622:2025
IEC 2025
Note 1 to entry: The rated capacity is the quantity of electricity C5 Ah (ampere-hours) declared by the manufacturer which a single cell can deliver during a 5 h period when charging, storing and discharging under the conditions specified in 7.3.2.
[SOURCE: IEC 60050-482:2004, 482-03-15, modified - Addition of the words "a cell or" in the definition, and of Note 1 to entry.]
3.1.16 State of charge
SOC remaining capacity to be discharged, normally expressed as a percentage of the cell rated capacity as per 7.3.2.2
3.1.17 State of charge at end of life
SOC at end of life remaining capacity to be discharged, normally expressed as a 60% of the cell rated capacity (3h discharge with 7.3.2.2 conditions)
3.1.18 CCCV charge
method of charge consisting in a charge at constant current followed by a charge at constant voltage
3.2 Abbreviated terms
BOL Beginning Of Life BTMS Battery Thermal Management System CCCV Constant Current Constant Voltage CRS Cumulated Requested Service DOD Depth Of Discharge EOL End Of Life LRU Line Replaceable Unit NiCd Nickel Cadmium Pc Constant power for cycling evolution RTE Round-Trip Efficiency SOC State Of Charge
4 Parameter measurement tolerances
The overall accuracy of controlled or measured values, relative to the specified or actual values, shall be within these tolerances:
a) ±1 % for voltage; b) ±1 % for current; c) ±2 °C for temperature; d) ±0,1 % for time; e) ±1 % for capacity.
These tolerances comprise the combined accuracy of the measuring instruments, the measurement techniques used, and all other sources of error in the test procedure. The details of the instrumentation used shall be provided in any report of results.
oSIST prEN IEC 60622:2025
IEC 2025
5 Designation and marking
5.1 Cell designation (mandatory)
Sealed nickel-cadmium prismatic secondary single cells shall be designated by the letter "KC" followed by a letter L, M, H or X which signifies:
- low rate of discharge (L);
- medium rate of discharge (M);
- high rate of discharge (H);
- very high rate of discharge (X).
NOTE 1 These types of cells are typically but not exclusively used for the following discharge rates:
- L up to 0,5 It A;
- M up to 3,5 It A;
- H up to 7,0 It A;
- X up to and above 7,0 It A.
NOTE 2 These currents are expressed as multiples of It A, where 𝐼𝐼 A =𝐶𝐶 Ah/1h (see IEC 61434 [3]). t 5 NOTE 3 In case the cells have internal separations but a common electrolyte, they are still considered as a single cell.
This group of three letters shall be followed by a group of figures indicative of the rated capacity of the cell in ampere-hours. Cells that have been tested at 20 °C and 5 °C but not at -18 °C shall carry an additional marking of T5: for example: KCH 185 or KCH 185 T5. As an option, cells in cases of plastic material shall be designated by the letter "P" after the figures (for example: KCH 185 P), or in case of steel cells with a letter "S".
5.2 Cell designation (optional)
The additional marking shall be added to the mandatory marking. When the marking would exceed the available space on the cell, this information may be omitted on the cell but shall be provided in the documentation corresponding to the cell and in the type test report, or in a shared IT system accessible to the end-user based on information on the cell label (e.g. data matrix).
If there is no mention concerning the marking for temperature, the cells shall have been tested at: -18 °C, 5 °C and 20 °C. Cells tested at other temperatures shall carry an additional marking of T followed by tested temperatures. In case the cell is characterized with both low and high temperature, they shall be indicated in increasing order with a solidus separating them: for example: KCH 185 P T-35/+45.
Cells tested with CCCV charges shall carry the marking of CCCV: for example, KCH 185 P CCCV.
Cells tested at rapid charge shall carry the marking R and the value of the tested rapid charge current, expressed in multiple of It A: for example, KCH 185 P R1. High grade cycling cells shall carry an additional marking C followed by the number of cycles:
for example, KCH 185 P C1500.
Cells having been tested with multiple types of tests shall carry the marking for the various tests performed: for example, KCH 185 P T-35/+45 CCCV R1 C1500.
oSIST prEN IEC 60622:2025
IEC 2025
5.3 Cell termination
This document does not specify cell termination.
5.4 Battery designation
5.4.1 Battery structure formulation
Modules, battery packs and battery systems are preferably designated as described below. In case of batteries where there are cells in series with crates or modules with different number of same capacity cells, the detailed information is not necessary in the designation, it is a constructive information already provided in the drawing.
Cells Designation as per 5.1 or 5.2 followed by the battery structure formulation:
a) it describes the number of cells in the minimum constitutive(s) entity(ies) and on the right side of the number, it describes their connection mode in series (S) or in parallel (P). See Annex C.
b) in the event that the minimum constitutive entities are connected in series or in parallel, it describes the number of minimum constitutive entities, and on the right side of the number, it describes their connection mode in series (S) or in parallel (P). See Annex C including some examples.
The battery designation should include the breakdown structure of the battery. The descriptive path followed to formulate the battery is from the smallest entity to the largest one:
EXAMPLE 1 "KCM130(80S)" would designate a prismatic sealed nickel-cadmium battery. Its rated capacity is 130 Ah with 80 cells. It is designed for a medium discharge rate.
EXAMPLE 2 "KCH100((2P)84S)" would designate a prismatic sealed nickel-cadmium battery system. Its rated capacity is 100 Ah. It is designed for a high discharge rate.
5.4.2 Definitions of components of a battery system
In order to clarify the definitions, this chapter presents practical examples See Figure 1 (images are examples) for the case of mobile applications.
oSIST prEN IEC 60622:2025
IEC 2025
Figure 1 – Definition of cell(s), monobloc battery, crate, tray, and box, example of mobile application Some batteries may not include all of the above components, e.g. single cells may be installed in a tray without crates. Some battery technologies may include further components (e.g. module) in the parts of this standard series if necessary.
For the case of stationary applications, see Figure 5 and Figure 3 - schematics as examples, with reference to Annex C.
oSIST prEN IEC 60622:2025
IEC 2025
Figure 2 – Definition of cell(s), crate/block/module, Battery, Cabinet, example of stationary application for Telecom In this example, the air conditioning system is common to cool the electronics and the cells in the crates. The battery system is including the part of the air conditioning equipment or enclosure that is needed for the battery cells. Allocation shall be made by the equipment manufacturer in the case of battery needing air conditioning, based on calculations of cooling power for each part. The same principle is applied for the cabinet.
oSIST prEN IEC 60622:2025
IEC 2025
Battery ((8S)5S)8P in a rack Figure 3 – Definition of cell(s), crate/block/module, Battery, rack, example of stationary application This Figure 3 describes sub-components of a battery system, as per example the enclosure is not included in this example, when it does have an impact on natural ventilation and therefore safety, See 10.4.1. The battery system manufacturer will include this sub-component together with other components that could impact e.g. safety for air circulation, or durability.
5.4.3 Classes of usage of battery system
Industrial Ni-Cd batteries are used in a large variety of applications and their main services shall be identified and categorized in classes in order to only compare the properties of batteries providing similar services.
The following classes are defined in this document:
- Applications with frequent repetitive charge and discharge cycles in mobile equipment (REP-MOB)
- Applications with frequent repetitive charge and discharge cycles in stationary equipment (REP-STAT)
- Applications with sporadic on-demand energy delivery in mobile equipment (OND-MOB)
- Applications with sporadic on-demand energy delivery in stationary equipment (OND-STAT) Each of these service classes requires an application-oriented adaptation of their design when their application is either mobile or stationary, due to very different mechanical architectures. This result in significant differences in their bill of material. In case the battery system can do both REP and OND, the main mode of battery operation shall be chosen.
Mobile equipment is defined in this document as being equipment which can move or be moved while in operation for example forklift trucks, golf carts and similar lightweight vehicles, automated guided vehicles, railway vehicles, marine vessels.
Stationary equipment is defined in this document as being all fixed equipment or equipment that cannot be easily moved.
oSIST prEN IEC 60622:2025
IEC 2025
For REP batteries, the notion of round-trip efficiency is meaningful, while not in the case of OND batteries.
5.5 Marking
Each cell or monobloc shall carry durable markings giving the following minimum information:
- type of cell (designation as specified in 5.1 and 5.2; in addition, it is permissible for a manufacturer to use his own type designation);
- name or identification of manufacturer or supplier;
- positive terminal: either a red washer or an indented or raised symbol (see graphical symbol IEC 60417-5005:2002-10).
5.6 Safety recommendations
The cell manufacturer shall provide recommendations for the safe handling of the cell. See also IEC TR 61438 [4].
NiCd batteries generate gases during normal operation (e.g. during float or boost charging). Sufficient ventilation is necessary in the battery system enclosure to avoid excessive accumulation of gases. The air inlet and outlet openings shall be arranged in such a way that sufficient air flow will be possible. Natural ventilation if possible is preferred or forced air circulation as per battery system manufacturer design.
The location of the openings on the enclosure depends on battery system location on the equipment and it shall be defined by end user and/ or system integrator considering the location of the battery system.
Refer to IEC 624852:2010 for the dimensions of the openings and other requirements. Also follow applicable local regulations. Cell/ battery manufacturer shall provide calculations upon request.
6 Dimensions
Dimensions of cells, shown in Figure 4, are given in Table 1 and Table 2.
oSIST prEN IEC 60622:2025
IEC 2025
NOTE 1 Cells in steel container can have two or more terminals and no or some lugs. NOTE 2 Cells in plastic container can have two or more terminals and no lugs. Figure 4 – Example of a sealed prismatic cell in steel container with two terminals and four lugs Table 1 – Example of dimensions for unjacketed sealed nickel-cadmium prismatic cells Width,b Maximum height,h Lengths,d mm mm mm 31 129 47 36 71 15 37 64 31 42 100 17 42 102 39 50 129 35 51 111 30 51 111 37 64 84 63 77 117 31 77 126 31 77 222 31 77 222 43 77 222 63 77 222 81 77 222 121 93 126 84 97 107 19
oSIST prEN IEC 60622:2025
IEC 2025
Table 2 – Example of dimensions for sealed nickel-cadmium prismatic cells in plastic containers Width, b Maximum height, h Lengths, d mm mm mm 62 178 28 78 285 50 81 241 28, 36, 43, 48 87 273 47, 86 123 273 28, 40, 50, 61 138 406 48, 55, 61, 70, 77, 85, 105, 115, 265 147 285 53, 78, 102 165 406 42, 66, 75, 105, 110, 130, 160 173 375 122, 197, 287, 392, 517 195 406 29, 34, 40, 50, 64, 80, 94, 115 NOTE 1 The dimensions given in Table 1 and Table 2 represent preferred values. For cells with deviating size, dimensions as per Figure 4 are indicated.
NOTE 2 The widths relate to the overall width dimension of the cell excluding the thickness of the lug flanges. The values for widths and lengths given in Table 1 and Table 2 are maximum values; their negative tolerances are given in Table 3.
...