Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation

This part of IEC 60079 gives instructions, principally of a technical nature, on the repair, overhaul, reclamation and modification of a certified equipment designed for use in explosive atmospheres; it is not applicable to maintenance, other than when repair and overhaul cannot be disassociated from maintenance, neither does it give advice on cable entry systems which may require renewal when the equipment is re-installed.

Explosionsfähige Atmosphäre - Teil 19: Gerätereparatur, Überholung und Regenerierung

Atmosphères explosives - Partie 19: Réparation, révision et remise en état du matériel

La présente partie de la CEI 60079 donne des instructions, principalement de nature technique, pour la réparation, la révision, la remise en état et la modification du matériel certifié conçu pour être utilisé en atmosphères explosives; il n'est pas applicable à l'entretien sauf lorsque la réparation et la révision ne peuvent être dissociées de l'entretien, pas plus qu'elle ne donne un conseil sur les systèmes d'entrées de câbles qui peuvent exiger un renouvellement quand le matériel est ré-installé.",PE

Eksplozivne atmosfere - 19. del: Popravilo, obnova in remont opreme (IEC 60079-19:2006)

General Information

Status
Withdrawn
Publication Date
19-Jul-2007
Withdrawal Date
30-Apr-2010
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Jan-2014
Completion Date
01-Jan-2014

Relations

Buy Standard

Standard
EN 60079-19:2008 (EN)
English language
58 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
EN 60079-19:2008 (FR)
French language
58 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamationEksplozivne atmosfere - 19. del: Popravilo, obnova in remont opreme (IEC 60079-19:2006)Atmospheres explosives - Partie 19: Réparation, révision et remise en état du matérielExplosionsfähige Atmosphäre - Teil 19: Gerätereparatur, Überholung und Regenerierung29.260.20Electrical apparatus for explosive atmospheresICS:SIST EN 60079-19:2008en,fr,deTa slovenski standard je istoveten z:EN 60079-19:200701-januar-2008SIST EN 60079-19:2008SLOVENSKI
STANDARD







EUROPEAN STANDARD EN 60079-19 NORME EUROPÉENNE
EUROPÄISCHE NORM July 2007
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2007 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60079-19:2007 E
ICS 29.260.20
English version
Explosive atmospheres -
Part 19: Equipment repair, overhaul and reclamation (IEC 60079-19:2006)
Atmosphères explosives -
Partie 19: Réparation, révision
et remise en état du matériel (CEI 60079-19:2006)
Explosionsfähige Atmosphäre -
Teil 19: Gerätereparatur, Überholung
und Regenerierung (IEC 60079-19:2006)
This European Standard was approved by CENELEC on 2007-04-11. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.



EN 60079-19:2007
- 2 -
Foreword The text of document 31J/124/FDIS, future edition 2 of IEC 60079-19, prepared by SC 31J, Classification of hazardous areas and installation requirements, of IEC TC 31, Equipment for explosive atmospheres, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60079-19 on 2007-04-11. The following dates were fixed: – latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement
(dop)
2008-02-01 – latest date by which the national standards conflicting
with the EN have to be withdrawn
(dow)
2010-05-01 Annex ZA has been added by CENELEC. __________ Endorsement notice The text of the International Standard IEC 60079-19:2006 was approved by CENELEC as a European Standard without any modification. __________



- 3 - EN 60079-19:2007 Annex ZA
(normative)
Normative references to international publications with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
NOTE
When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies.
Publication Year Title EN/HD Year
IEC 60079 Series Explosive atmospheres
EN 60079 Series
IEC 60085 -1) Electrical insulation - Thermal classification EN 60085 20042)
IEC 60529 -1) Degrees of protection provided by enclosures (IP Code) EN 60529 + corr. May
19912) 1993
IEC 61241-0 (mod)
-1) Electrical apparatus for use in the presence
of combustible dust -
Part 0: General requirements EN 61241-0 20062)
IEC 61241-2 Series Electrical apparatus for use in the presence
of combustible dust -
Part 2: Test methods - -
ISO 4526 -1) Metallic coatings - Electroplated coatings of nickel for engineering purposes EN ISO 4526 20042)
ISO 6158 -1) Metallic coatings - Electrodeposited coatings of chromium for engineering purposes EN ISO 6158 20042)
ISO 9000 -1) Quality management systems - Fundamentals and vocabulary EN ISO 9000 20052)
1) Undated reference. 2) Valid edition at date of issue.







IEC 60079-19Edition 2.0 2006-10INTERNATIONAL STANDARD NORME INTERNATIONALEExplosive atmospheres – Part 19: Equipment repair, overhaul and reclamation
Atmosphères explosives –
Partie 19: Réparation, révision et remise en état du mat
...

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Eksplozivne atmosfere - 19. del: Popravilo, obnova in remont opreme (IEC 60079-19:2006)Explosionsfähige Atmosphäre -- Teil 19: Gerätereparatur, Überholung und RegenerierungAtmosphères explosives -- Partie 19: Réparation, révision et remise en état du matérielExplosive atmospheres -- Part 19: Equipment repair, overhaul and reclamation29.260.20Electrical apparatus for explosive atmospheresICS:Ta slovenski standard je istoveten z:EN 60079-19:2007SIST EN 60079-19:2008en,fr,de01-januar-2008SIST EN 60079-19:2008SLOVENSKI
STANDARDSIST IEC 60079-19:19961DGRPHãþD



SIST EN 60079-19:2008



NORME EUROPÉENNE EN 60079-19 EUROPÄISCHE NORM
EUROPEAN STANDARD Juillet 2007
CENELEC Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung European Committee for Electrotechnical Standardization
Secrétariat Central: rue de Stassart 35, B - 1050 Bruxelles
© 2007 CENELEC -
Tous droits d'exploitation sous quelque forme et de quelque manière que ce soit réservés dans le monde entier aux membres du CENELEC.
Ref. n° EN 60079-19:2007 F
ICS 29.260.20
Version française
Atmosphères explosives -
Partie 19: Réparation, révision et remise en état du matériel (CEI 60079-19:2006)
Explosionsfähige Atmosphäre -
Teil 19: Gerätereparatur, Überholung
und Regenerierung (IEC 60079-19:2006)
Explosive atmospheres -
Part 19: Equipment repair, overhaul
and reclamation (IEC 60079-19:2006)
La présente Norme Européenne a été adoptée par le CENELEC le 2007-04-11. Les membres du CENELEC sont tenus de se soumettre au Règlement Intérieur du CEN/CENELEC qui définit les conditions dans lesquelles doit être attribué, sans modification, le statut de norme nationale à la Norme Européenne.
Les listes mises à jour et les références bibliographiques relatives à ces normes nationales peuvent être obtenues auprès du Secrétariat Central ou auprès des membres du CENELEC.
La présente Norme Européenne existe en trois versions officielles (allemand, anglais, français). Une version dans une autre langue faite par traduction sous la responsabilité d'un membre du CENELEC dans sa langue nationale, et notifiée au Secrétariat Central, a le même statut que les versions officielles.
Les membres du CENELEC sont les comités électrotechniques nationaux des pays suivants: Allemagne, Autriche, Belgique, Bulgarie, Chypre, Danemark, Espagne, Estonie, Finlande, France, Grèce, Hongrie, Irlande, Islande, Italie, Lettonie, Lituanie, Luxembourg, Malte, Norvège, Pays-Bas, Pologne, Portugal, République Tchèque, Roumanie, Royaume-Uni, Slovaquie, Slovénie, Suède et Suisse.
SIST EN 60079-19:2008



EN 60079-19:2007
- 2 -
Avant-propos Le texte du document 31J/124/FDIS, future édition 2 de la CEI 60079-19, préparé par le SC 31J, Classification des emplacements dangereux et règles d'installation, du CE 31 de la CEI, Equipement pour atmosphères explosives, a été soumis au vote parallèle CEI-CENELEC et a été approuvé par le CENELEC comme EN 60079-19 le 2007-04-11. Les dates suivantes ont été fixées: – date limite à laquelle la EN doit être mise en application
au niveau national par publication d'une norme
nationale identique ou par entérinement
(dop)
2008-02-01 – date limite à laquelle les normes nationales
conflictuelles doivent être annulées
(dow)
2010-05-01 L'Annexe ZA a été ajoutée par le CENELEC. __________ Notice d’entérinement Le texte de la Norme internationale CEI 60079-19:2006 a été approuvé par le CENELEC comme Norme Européenne sans aucune modification. __________ SIST EN 60079-19:2008



- 3 - EN 60079-19:2007 Annexe ZA
(normative)
Références normatives à d'autres publications internationales avec les publications européennes correspondantes
Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du document de référence s'applique (y compris les éventuels amendements).
NOTE
Dans le cas où une publication internationale est modifiée par des modifications communes, indiqué par (mod), l'EN / le HD correspondant(e) s'applique.
Publication Année Titre EN/HD Année
CEI 60079 série Atmosphères explosives
EN 60079 série
CEI 60085 -1) Isolation électrique - Classification thermique EN 60085 20042)
CEI 60529 -1) Degrés de protection procurés par les enveloppes (Code IP) EN 60529 + corr. mai
19912) 1993
CEI 61241-0 (mod)
-1) Matériels électriques pour utilisation en présence de poussières combustibles -
Partie 0: Exigences générales EN 61241-0 20062)
CEI 61241-2 série Matériels électriques destinés à être utilisés en présence de poussières combustibles -
Partie 2: Méthodes d'essais - -
ISO 4526 -1) Revêtements métalliques - Dépôts électrolytiques de nickel pour usages industriels EN ISO 4526 20042)
ISO 6158 -1) Revêtements métalliques - Dépôts électrolytiques de chrome pour usages industriels EN ISO 615
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.