Amendment 1 - LED light source characteristics - Part 1: Data sheets

Eigenschaften von LED-Lichtquellen - Teil 1: Datenblätter

Caractéristiques de source lumineuse à LED – Partie 1: Feuilles de caractéristiques

Značilnosti LED-svetlobnega vira - 1. del: Preglednice - Dopolnilo A1

General Information

Status
Not Published
Publication Date
05-Nov-2024
Current Stage
4060 - Enquiry results established and sent to TC, SR, BTTF - Enquiry
Start Date
07-Apr-2023
Completion Date
07-Apr-2023

Relations

Buy Standard

Draft
EN IEC 63356-1:2023/oprA1:2023
English language
35 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN IEC 63356-1:2023/oprA1:2023
01-marec-2023
Značilnosti LED-svetlobnega vira - 1. del: Preglednice - Dopolnilo A1
Amendment 1 - LED light source characteristics - Part 1: Data sheets
Eigenschaften von LED-Lichtquellen - Teil 1: Datenblätter

Caractéristiques de source lumineuse à LED Partie 1: Feuilles de caractéristiques

Ta slovenski standard je istoveten z: EN IEC 63356-1:2022/prA1:2023
ICS:
29.140.01 Žarnice na splošno Lamps in general
SIST EN IEC 63356-1:2023/oprA1:2023 en

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
---------------------- Page: 2 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
34A/2319/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 63356-1/AMD1 ED1
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2023-01-13 2023-04-07
SUPERSEDES DOCUMENTS:
34A/2294/CD, 34A/2317/CC
IEC SC 34A : ELECTRIC LIGHT SOURCES
SECRETARIAT: SECRETARY:
United Kingdom Mr Petar Luzajic
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:
TC 34,SC 34B,SC 34C,SC 34D
Other TC/SCs are requested to indicate their interest, if
any, in this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY

SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING

Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.

This document is still under study and subject to change. It should not be used for reference purposes.

Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of

which they are aware and to provide supporting documentation.
TITLE:
Amendment 1 - LED light source characteristics - Part 1: Data sheets
PROPOSED STABILITY DATE: 2026
NOTE FROM TC/SC OFFICERS:

Copyright © 2022 International Electrotechnical Commission, IEC. All rights reserved. It is permitted to

download this electronic file, to make a copy and to print out the content for the sole purpose of preparing

National Committee positions. You may not copy or "mirror" the file or printed version of the document, or any

part of it, for any other purpose without permission in writing from IEC.
---------------------- Page: 3 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 2 34A/2319/CDV
1 Proposal to amend IEC 63356-1 clause 4.1 as follows:

2 Replace “Unless otherwise specified, mechanical dimensions refer to a temperature of (25 ±

3 5) °C.” by “Unless otherwise specified, dimensions are specified at a temperature of (25 ± 5) °C.”

4 Proposal to amend IEC 63356-1 data sheet table structure as follows:
5 Clause 4.3.1: Add the following introductory text

6 Tables 1A, 1B and 1C provide a summary of data sheets for non-integrated, semi-integrated

7 and integrated single-capped LED lamps respectively.
8 Clause 4.3.1: Add the following table caption placeholders
9 Table 1B – List of data sheets for semi-integrated single-capped LED lamps
10 Void
11 Table 1C – List of data sheets for integrated single-capped LED lamps
12 Void
13 Clause 4.3.2: Add the following introductory text

14 Tables 2A, 2B and 2C provide a summary of data sheets for non-integrated, semi-integrated

15 and integrated double-capped LED lamps respectively.
16 Clause 4.3.2: Replace existing Table 1 with the following Table 2A
17 Table 2A – List of data sheets for non-integrated double-capped LED lamps
Sheet no. Shape Nominal Rated Rated Power range Cap
63356-1-IEC- length diameter current W
2xx-xxxx mm mm
200-0001-1 linear 600 25,5 0,35 A DC 7,9 to 16,6 GX16t-5
200-0002-1 linear 600 32,5 0,35 A DC 7,9 to 16,6 GX16t-5
200-0003-1 linear 900 25,5 0,35 A DC 11,0 to 24,8 GX16t-5
200-0004-1 linear 900 32,5 0,35 A DC 11,0 to 24,8 GX16t-5
200-0005-1 linear 1 200 25,5 0,35 A DC 14,3 to 33,3 GX16t-5
200-0006-1 linear 1 200 32,5 0,35 A DC 14,3 to 33,3 GX16t-5
200-0007-1 linear 1 500 25,5 0,35 A DC 14,3 to 42,0 GX16t-5
200-0008-1 linear 1 500 32,5 0,35 A DC 14,3 to 42,0 GX16t-5
200-0009-1 linear 2 400 25,5 0,35 A DC 28,7 to 66,5 GX16t-5
200-0010-1 linear 2 400 32,5 0,35 A DC 28,7 to 66,5 GX16t-5
19 Clause 4.3.2: Add the following table caption placeholder
20 Table 2B – List of data sheets for semi-integrated double-capped LED lamps
21 Void
22 Clause 4.3.3: Add the following introductory text

23 Tables 3A, 3B and 3C provide a summary of data sheets for non-integrated, semi-integrated

24 and integrated LED modules respectively.
25 Clause 4.3.3: Add the following table caption placeholders
26 Table 3A – List of data sheets for non-integrated LED modules
27 Void
28 Table 3B – List of data sheets for semi-integrated LED modules
29 Void
30 Table 3C – List of data sheets for integrated LED modules
31 Void

32 Proposal to amend IEC 63356-1 to include data sheets for GH36d capped LED lamps as

33 follows:
---------------------- Page: 4 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 3 34A/2319/CDV
34 Clause 4.3.1: Add the following new Table 1A
35 Table 1A – List of data sheets for non-integrated single-capped LED lamps
Sheet no. Shape Rated Rated Power range Cap
63356-1-IEC- diameter current W
1xx-xxxx mm
100-0001-1 round 50 0,25 A DC 5,0 to 12,5 GH36d-1
100-0002-1 round 50 0,35 A DC 7,0 to 17,5 GH36d-2
100-0003-1 round 50 0,5 A DC 10,0 to 25,0 GH36d-3
100-0004-1 round 50 0,7 A DC 14,0 to 35,0 GH36d-4
100-0005-1 round 50 0,9 A DC 18,0 to 45,0 GH36d-5
100-0006-1 round 50 1,1 A DC 22,0 to 55,0 GH36d-6
43 New clauses: Add the following as a new clauses 5.1, 5.1.1 and 5.1.2.

44 Add the new Figure 1 and renumber subsequent figures (existing Figure 1 → Figure 2). Also,

45 update the reference to existing Figure 1 in clause 6.1.1.
---------------------- Page: 5 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 4 34A/2319/CDV
47 5.1 Single-capped LED lamps with GH36d caps
48 5.1.1 Diagrammatic information for location of lamp dimensions

49 Figure 1 shows the dimensions used in conjunction with the relevant data sheet for a GH36d

50 LED lamp.
(3)
(1)
(2) Thermal conductivity cylinder
51 (1) Reference plane

52 (2) The GH36d capped LED lamp is designed to be applied to a heat sink and in combination with the appropriate

53 key system to differentiate between input power combinations.
54 (3) Key position
55 NOTE: Details about key position are shown in IEC 60061-1 sheet 7004-186.
56 Figure 1 – Location of dimensions of single-capped lamps with a GH36d cap
---------------------- Page: 6 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 5 34A/2319/CDV
58 5.1.2 Data sheets
59 Data sheet 63356-1-IEC-100-0001-1:
Nominal diameter Rated DC lamp current Range of lamp power Cap
mm A W
50 0,25 5,0 to 12,5 GH36d-1
Dimensions
A B D K T
Min. Max. Min. Max. Min. Max. Min. Max.
49,5 50,5 24,9 25,2 36,0 8,5 9,0 5,5 30,0
Electrical characteristics
DC test current DC lamp voltage
A V
Min. Max.
0,25
20 50
Information for controlgear design
Constant DC current output
Type of controlgear
SELV or PELV
Min. Max.
DC output voltage range for the constant DC current
20 50
Tolerance of the constant DC current 10 %
---------------------- Page: 7 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 6 34A/2319/CDV
63 Data sheet 63356-1-IEC-100-0002-1:
Nominal diameter Rated DC lamp current Range of lamp power Cap
mm A W
50 0,35 7,0 to 17,5 GH36d-2
Dimensions
A B D K T
Min. Max. Min. Max. Min. Max. Min. Max.
49,5 50,5 24,9 25,2 36,0 8,5 9,0 5,5 30,0
Electrical characteristics
DC test current DC lamp voltage
A V
Min. Max.
0,35
20 50
Information for controlgear design
Constant DC current output
Type of controlgear
SELV or PELV
Min. Max.
DC output voltage range for the constant DC current
20 50
Tolerance of the constant DC current 10 %
---------------------- Page: 8 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 7 34A/2319/CDV
66 Data sheet 63356-1-IEC-100-0003-1:
Nominal diameter Rated DC lamp current Range of lamp power Cap
mm A W
50 0,5 10,0 to 25,0 GH36d-3
Dimensions
A B D K T
Min. Max. Min. Max. Min. Max. Min. Max.
49,5 50,5 24,9 25,2 36,0 8,5 9,0 5,5 30,0
Electrical characteristics
DC test current DC lamp voltage
A V
Min. Max.
0,5
20 50
Information for controlgear design
Constant DC current output
Type of controlgear
SELV or PELV
Min. Max.
DC output voltage range for the constant DC current
20 50
Tolerance of the constant DC current 10 %
---------------------- Page: 9 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 8 34A/2319/CDV
70 Data sheet 63356-1-IEC-100-0004-1:
Nominal diameter Rated DC lamp current Range of lamp power Cap
mm A W
50 0,7 14,0 to 35,0 GH36d-4
Dimensions
A B D K T
Min. Max. Min. Max. Min. Max. Min. Max.
49,5 50,5 24,9 25,2 36,0 8,5 9,0 5,5 30,0
Electrical characteristics
DC test current DC lamp voltage
A V
Min. Max.
0,7
20 50
Information for controlgear design
Constant DC current output
Type of controlgear
SELV or PELV
Min. Max.
DC output voltage range for the constant DC current
20 50
Tolerance of the constant DC current 10 %
---------------------- Page: 10 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 9 34A/2319/CDV
73 Data sheet 63356-1-IEC-100-0005-1:
Nominal diameter Rated DC lamp current Range of lamp power Cap
mm A W
50 0,9 18,0 to 45,0 GH36d-5
Dimensions
A B D K T
Min. Max. Min. Max. Min. Max. Min. Max.
49,5 50,5 24,9 25,2 36,0 8,5 9,0 5,5 30,0
Electrical characteristics
DC test current DC lamp voltage
A V
Min. Max.
0,9
20 50
Information for controlgear design
Constant DC current output
Type of controlgear
SELV or PELV
Min. Max.
DC output voltage range for the constant DC current
20 50
Tolerance of the constant DC current 10 %
---------------------- Page: 11 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 10 34A/2319/CDV
77 Data sheet 63356-1-IEC-100-0006-1:
Nominal diameter Rated DC lamp current Range of lamp power Cap
mm A W
50 1,1 22,0 to 55,0 GH36d-6
Dimensions
A B D K T
Min. Max. Min. Max. Min. Max. Min. Max.
49,5 50,5 24,9 25,2 36,0 8,5 9,0 5,5 30,0
Electrical characteristics
DC test current DC lamp voltage
A V
Min. Max.
1,1
20 50
Information for controlgear design
Constant DC current output
Type of controlgear
SELV or PELV
Min. Max.
DC output voltage range for the constant DC current
20 50
Tolerance of the constant DC current 10 %
---------------------- Page: 12 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 11 34A/2319/CDV

81 Proposal to amend IEC 63356-1 to include data sheets for GJ6.6t and GJ6.6d-1 capped

82 LED lamps as follows:
83 Clause 4.3.2: Add the following new Table 2C
84 Table 2C – List of data sheets for integrated double-capped LED lamps
Sheet no. Shape Nominal Maximum Rated voltage Power range Cap
63356-1-IEC- length outline W
2xx-xxxx mm diameter
220-0001-1 linear 550 17,0 108 to 382 V AC 7,0 to 13,0 GJ6.6t
220-0002-1 linear 600 26,7 108 to 382 V AC 8,0 to 17,0 GJ6.6t
220-0003-1 linear 850 17,0 108 to 382 V AC 10,0 to 16,0 GJ6.6t
220-0004-1 linear 900 26,7 108 to 382 V AC 11,5 to 25,0 GJ6.6t
220-0005-1 linear 1150 17,0 108 to 382 V AC 13,0 to 31,0 GJ6.6t
220-0006-1 linear 1200 26,7 108 to 382 V AC 9,9 to 32,0 GJ6.6t
220-0007-1 linear 1450 17,0 108 to 382 V AC 18,0 to 37,0 GJ6.6t
220-0008-1 linear 2400 26,7 108 to 382 V AC 30,0 to 65,0 GJ6.6t
220-0009-1 linear 550 17,0 108 to 382 V AC 7,0 to 13,0 GJ6.6d-1
220-0010-1 linear 600 26,7 108 to 382 V AC 8,0 to 17,0 GJ6.6d-1
220-0011-1 linear 850 17,0 108 to 382 V AC 10,0 to 16,0 GJ6.6d-1
220-0012-1 linear 900 26,7 108 to 382 V AC 11,5 to 25,0 GJ6.6d-1
220-0013-1 linear 1150 17,0 108 to 382 V AC 13,0 to 31,0 GJ6.6d-1
220-0014-1 linear 1200 26,7 108 to 382 V AC 9,9 to 32,0 GJ6.6d-1
220-0015-1 linear 1450 17,0 108 to 382 V AC 18,0 to 37,0 GJ6.6d-1
220-0016-1 linear 2400 26,7 108 to 382 V AC 30,0 to 65,0 GJ6.6d-1
85 New clauses: Add the following as a new clauses 6.2, 6.2.1 and 6.2.2.
86 Add the new Figure 3 below.
87 6.2 Linear double-capped LED lamp with GJ6.6 caps
88 6.2.1 Diagrammatic information for location of lamp dimensions

89 Figure 3 shows the dimensions used in conjunction with the relevant data sheet for a GJ6.6

90 LED lamp.
92 Dimension C = inner distance between windows in GJ6.6 caps
93 Dimension D = the maximum dimension of the cross section of the LED tube.
94 NOTE: The LED tube can be of any shape.

95 NOTE: GJ6.6, GJ6.6t, GJ6.6d-1 and GJ6.6d-2 cap dimensions are specified in IEC 60061-1

96 Figure 3 – Location of dimensions of linear double-capped lamps with GJ6.6 caps

---------------------- Page: 13 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 12 34A/2319/CDV
98 6.2.2 GJ6.6 lamp data sheets
99 Data sheet 63356-1-IEC-220-0001-1:
Nominal length Range of supply voltage Max. lamp power Caps
mm V W
550 108 to 382 14,5 GJ6.6t and GJ6.6
Dimensions
C D
Min. Max. Max.
551,0 551,6 17,0
Electrical characteristics
Lamp voltage Lamp power
Range (typical) Range (typical)
120 to 277 7,0 to 13,0
220 to 240 7,0 to 13,0

Earthing: The GJ6.6t cap and holder system provides a protective earthing terminal. LED

linear lamps with a GJ6.6t cap can be designed with or without protective earthing.

106
Information for luminaire design

Insulation: Lamps with a GJ6.6t cap have an earthing terminal and may require a protective

earth. Luminaires with a GJ6.6t lampholder should be of Class I construction and provide a

protective earth to the GJ6.6t lampholder terminal.
107

The fit system comprises a GJ6.6t cap on the powered end of the lamp and a GJ6.6 support cap on the other end.

A requirement to mark the rated input voltage or voltage range on LED linear lamps is included in IEC 63220

(pending).
---------------------- Page: 14 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 13 34A/2319/CDV
109 Data sheet 63356-1-IEC-220-0002-1:
Nominal length Range of supply voltage Max. lamp power Caps
mm V W
600 108 to 382 19,0
GJ6.6t and GJ6.6
Dimensions
C D
Min. Max. Max.
591,8 592,4 26,7
Electrical characteristics
Lamp voltage Lamp power
V W
Range (typical) Range (typical)
120 to 277 8,0 to 17,0
220 to 240 8,0 to 17,0

Earthing: The GJ6.6t cap and holder system provides a protective earthing terminal. LED

linear lamps with a GJ6.6t cap can be designed with or without protective earthing.

110
Information for luminaire design

Insulation: Lamps with a GJ6.6t cap have an earthing terminal and may require a protective

earth. Luminaires with a GJ6.6t lampholder should be of Class I construction and provide a

protective earth to the GJ6.6t lampholder terminal.
111

The fit system comprises a GJ6.6t cap on the powered end of the lamp and a GJ6.6 support cap on the other end.

A requirement to mark the rated input voltage or voltage range on LED linear lamps is included in IEC 63220

(pending).
---------------------- Page: 15 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 14 34A/2319/CDV
113 Data sheet 63356-1-IEC-220-0003-1:
114
Nominal length Range of supply voltage Max. lamp power Caps
mm V W
850 108 to 382 18,0 GJ6.6t and GJ6.6
Dimensions
C D
Min. Max. Max.
851,0 851,6 17,0
Electrical characteristics
Lamp voltage Lamp power
V W
Range (typical) Range (typical)
120 to 277 10,0 to 16,0
220 to 240 10,0 to 16,0

Earthing: The GJ6.6t cap and holder system provides a protective earthing terminal. LED

linear lamps with a GJ6.6t cap can be designed with or without protective earthing.

115
Information for luminaire design

Insulation: Lamps with a GJ6.6t cap have an earthing terminal and may require a protective

earth. Luminaires with a GJ6.6t lampholder should be of Class I construction and provide a

protective earth to the GJ6.6t lampholder terminal.
116

The fit system comprises a GJ6.6t cap on the powered end of the lamp and a GJ6.6 support cap on the other end.

A requirement to mark the rated input voltage or voltage range on LED linear lamps is included in IEC 63220

(pending).
---------------------- Page: 16 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 15 34A/2319/CDV
118 Data sheet 63356-1-IEC-220-0004-1:
119
Nominal length Range of supply voltage Max. lamp power Caps
mm V W
900 108 to 382 28,0 GJ6.6t and GJ6.6
120
121
Dimensions
C D
Min. Max. Max.
896,6 897,2 26,7
122
Electrical characteristics
Lamp voltage Lamp power
V W
Range (typical) Range (typical)
120 to 277 11,5 to 25,0
220 to 240 11,5 to 25,0

Earthing: The GJ6.6t cap and holder system provides a protective earthing terminal. LED

linear lamps with a GJ6.6t cap can be designed with or without protective earthing.

123
124
Information for luminaire design

Insulation: Lamps with a GJ6.6t cap have an earthing terminal and may require a protective

earth. Luminaires with a GJ6.6t lampholder should be of Class I construction and provide a

protective earth to the GJ6.6t lampholder terminal.
125

The fit system comprises a GJ6.6t cap on the powered end of the lamp and a GJ6.6 support cap on the other end.

A requirement to mark the rated input voltage or voltage range on LED linear lamps is included in IEC 63220

(pending).
---------------------- Page: 17 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 16 34A/2319/CDV
127 Data sheet 63356-1-IEC-220-0005-1:
128
Nominal length Range of supply voltage Max. lamp power Caps
mm V W
1150 108 to 382 35,0 GJ6.6t and GJ6.6
129
130
Dimensions
C D
Min. Max. Max.
1151,0 1151,6 17,0
131
Electrical characteristics
Lamp voltage Lamp power
V W
Range (typical) Range (typical)
120 to 277 13,0 to 31,0
220 to 240 13,0 to 31,0

Earthing: The GJ6.6t cap and holder system provides a protective earthing terminal. LED

linear lamps with a GJ6.6t cap can be designed with or without protective earthing.

132
133
Information for luminaire design

Insulation: Lamps with a GJ6.6t cap have an earthing terminal and may require a protective

earth. Luminaires with a GJ6.6t lampholder should be of Class I construction and provide a

protective earth to the GJ6.6t lampholder terminal.
134

The fit system comprises a GJ6.6t cap on the powered end of the lamp and a GJ6.6 support cap on the other end.

A requirement to mark the rated input voltage or voltage range on LED linear lamps is included in IEC 63220

(pending).
---------------------- Page: 18 ----------------------
SIST EN IEC 63356-1:2023/oprA1:2023
IEC CDV 63356-1 © IEC 2022 17 34A/2319/CDV
136 Data sheet 63356-1-IEC-220-0006-1:
137
Nominal length Range of supply voltage Max. lamp power Caps
mm V W
1200 108 to 382 36,0 GJ6.6t and GJ6.6
138
139
Dimensions
C D
Min. Max. Max.
1201,4 1202,0 26,7
140
Electrical characteristics
Lamp voltage Lamp power
V W
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.