Electrical insulating materials - Thermal endurance properties - Part 6: Determination of thermal endurance indices (TI and RTE) of an insulating material using the fixed time frame method

Specifies the experimental and calculation procedures for deriving the thermal endurance characteristics, temperature index (TI) and relative thermal endurance index (RTE) of a material using the fixed time frame method (FTFM). In this protocol, the ageing takes place for a small number of fixed times, using the appropriate number of ageing temperatures throughout each time, the properties of the specimens being measured at the end of the relevant time interval. This differs from the procedure of EN 60216-1, where ageing is conducted at a small number of fixed temperatures, property measurement taking place after ageing times dependent on the progress of ageing. Both the TI and the RTE determined according to the FTFM protocol are derived from experimental data obtained in accordance with the instructions of EN 60216-1 and EN 60216-2, as modified in this standard. The calculation procedures and statistical tests are modified in relation to EN 60216-3 and EN 60216-5.

Elektroisolierstoffe - Eigenschaften hinsichtlich des thermischen Langzeitverhaltens - Teil 6: Bestimmung der thermischen Langzeitkennwerte (TI und RTE) eines Isolierstoffes unter Anwendung des Festzeitrahmenverfahrens

Matériaux isolants électriques - Propriétés d'endurance thermique - Partie 6: Détermination des indices d'endurance thermique (TI et RTE) d'un matériau isolant en utilisant la méthode de trame de durées fixes

Spécifie les méthodes expérimentales et de calcul à utiliser pour en extraire les caractéristiques d'endurance thermique, l'indice de température (TI) et l'indice d'endurance thermique relatif (RTE) d'un matériau en utilisant la méthode de trame de durées fixes (fixed time frame). Avec ce protocole, le vieillissement se produit après un petit nombre de durées déterminées, en utilisant le nombre approprié de températures de vieillissement tout au long de chaque durée pertinente, les propriétés des éprouvettes étant mesurées à la fin de chaque intervalle de temps. Cela diffère de la méthode de la EN 60216-1, dans laquelle le vieillissement est effectué à un petit nombre de températures déterminées, la mesure des propriétés des éprouvettes se produisant après des durées de vieillissement variables en fonction de la progression du vieillissement. Les deux indices d'endurance thermique, TI et RTE déterminés selon le protocole FTFM (fixed time frame method), sont déduits des données expérimentales obtenues conformément aux instructions de la EN 60216-1 et de la EN 60216-2, et conformément aux modifications de la présente norme. Les méthodes de calcul et les essais statistiques sont différents de ceux de la EN 60216-3 et de la EN 60216-5.

Električni izolacijski materiali - Lastnosti toplotne vzdržljivosti - 6. del: Ugotavljanje indikatorjev toplotne vzdržljivosti (TI in RTE) izolacijskega materiala po metodi s fiksnim časovnim okvirom (IEC 60216-6:2003)

General Information

Status
Withdrawn
Publication Date
11-Mar-2004
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Sep-2009
Completion Date
01-Sep-2009

Relations

Buy Standard

Standard
EN 60216-6:2004
English language
45 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SIST EN 60216-6:2004SLOVENSKIseptember 2004
STANDARDElektrični izolacijski materiali - Lastnosti toplotne vzdržljivosti - 6. del: Ugotavljanje indikatorjev toplotne vzdržljivosti (TI in RTE) izolacijskega materiala po metodi s fiksnim časovnim okvirom (IEC
60216-6:2003)Electrical insulating materials - Thermal endurance properties - Part 6: Determination of thermal endurance indices (TI and RTE) of an insulating material using the fixed time frame method (IEC 60216-6:2003)©
Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljenoReferenčna številkaSIST EN 60216-6:2004(en)ICS29.035.01







EUROPEAN STANDARD
EN 60216-6 NORME EUROPÉENNE EUROPÄISCHE NORM
March 2004 CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60216-6:2004 E
ICS 17.220.99; 29.035.01
English version
Electrical insulating materials -
Thermal endurance properties Part 6: Determination of thermal endurance indices (TI and RTE)
of an insulating material using the fixed time frame method (IEC 60216-6:2003)
Matériaux isolants électriques -
Propriétés d'endurance thermique Partie 6: Détermination des indices d'endurance thermique (TI et RTE)
d'un matériau isolant en utilisant
la méthode de trame de durées fixes (CEI 60216-6:2003)
Elektroisolierstoffe -
Eigenschaften hinsichtlich
des thermischen Langzeitverhaltens Teil 6: Bestimmung der thermischen Langzeitkennwerte (TI und RTE) eines Isolierstoffes unter Anwendung
des Festzeitrahmenverfahrens (IEC 60216-6:2003)
This European Standard was approved by CENELEC on 2004-03-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.



EN 60216-6:2004 - 2 -



- 3 - EN 60216-6:2004 Foreword
The text of document 15E/221/FDIS, future edition 1 of IEC 60216-6, prepared by SC 15E, Methods of test, of IEC TC 15, Insulating materials, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60216-6 on 2004-03-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement
(dop) 2004-12-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn
(dow) 2007-03-01
Annex ZA has been added by CENELEC. __________
Endorsement notice
The text of the International Standard IEC 60216-6:2003 was approved by CENELEC as a European Standard without any modification. __________



EN 60216-6:2004 - 4 - Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60212 1971 Standard conditions for use prior to and during the testing of solid electrical insulating materials
HD 437 S1 1984 IEC 60216-1 2001 Electrical insulating materials - Properties of thermal endurance Part 1: Ageing procedures and evaluation of test results
EN 60216-1 2001 IEC 60216-2 1990 Part 2: Choice of test criteria
HD 611.2 S1 1992 IEC 60216-3 2002 Part 3: Instructions for calculating thermal endurance characteristics
EN 60216-3 2002 IEC 60216-4-1 1990 Part 4: Ageing ovens - Section 1: Single-chamber ovens
HD 611.4.1 S1 1992 IEC 60216-4-2 2000 Part 4-2: Ageing ovens - Precision ovens for use up to 300 °C
EN 60216-4-2 2000 IEC 60216-4-3 2000 Part 4-3: Ageing ovens - Multi-chamber ovens
EN 60216-4-3 2000 IEC 60216-5 2003 Part 5: Determination of relative thermal endurance index (RTE) of an insulating material
EN 60216-5 2003 IEC 60493-1 1974 Guide for the statistical analysis of ageing test data Part 1: Methods based on mean values of normally distributed test results - -



NORME INTERNATIONALECEIIECINTERNATIONALSTANDARD 60216-6Première éditionFirst edition2003-12Matériaux isolants électriques – Propriétés d'endurance thermique – Partie 6: Détermination des indices d'endurance thermique (TI et RTE) d'un matériau isolant en utilisant la méthode de trame de durées fixes Electrical insulating materials – Thermal endurance properties – Part 6: Determination of thermal endurance indices (TI and RTE) of an insulating material using the fixed time frame method Pour prix, voir catalogue en vigueur For price, see current catalogue© IEC 2003
Droits de reproduction réservés

Copyright - all rights reservedAucune partie de cette publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de l'éditeur. No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Electrotechnical Commission,
3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, SwitzerlandTelephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch
Web: www.iec.ch CODE PRIX PRICE CODE XCommission Electrotechnique InternationaleInternational Electrotechnical Commission



60216-6 © IEC:2003 – 3 – CONTENTS FOREWORD.5 1 Scope.11 2 Normative references.11 3 Terms, definitions, symbols and abbreviated terms.13 3.1 Terms, abbreviations and definitions.13 3.2 Symbols and abbreviated terms.19 4 FTFM protocol – Principles and objectives.21 4.1 Principles of FTFM protocol.21 4.2 Objectives of FTFM protocol.21 5 TI determination.235.1 Ageing procedures.23 5.2 Ageing times and temperatures.23 5.3 Test specimens.25 5.4 Diagnostic tests.27 5.5 Selection of end-points.27 5.6 Establishment of initial property value.27 5.7 Ageing conditions.29 5.8 Procedure for ageing.29 6 Calculation procedures.31 6.1 General principles.31 6.2 Precision of calculations.33 6.3 Derivation of temperatures equivalent to property values.33 6.4 Regression analysis (temperature on time).39 6.5 Statistical tests.43 6.6 Thermal endurance graph.47 7 Calculation and requirements for results.49 7.1 Calculation of thermal endurance characteristics.49 7.2 Reporting of results.49 8 Report.51 9 RTE Determination – Objectives.51 10 Additional symbols.5311 Experimental procedures.53 12 Calculation procedures.55 12.1 General principles.55 12.2 Input data.5512.3 RTE.5712.4 Confidence limits.57 12.5 Extrapolation.61 13 Results and report.6113.1 Results of statistical and numerical tests.61 13.2 Result.6113.3 Report.61



60216-6 © IEC:2003 – 5 – Annex A (normative)
Decision flow chart.63 Annex B (normative)
Decision table .65 Annex C (informative)
Statistical tables.67 Annex D (informative)
Suggested ageing times and temperatures.73 Annex E (informative)
Figures.77 Annex F (normative)
Statistical significance of the difference
between two regression estimates.83 Figure E.1 – Property–temperature graph with regression line.77 Figure E.2 – Thermal endurance graph.77 Figure E.3 – Ageing times and temperatures in relation to thermal endurance graph.79 Figure E.4 – Ageing times and temperatures in relation to thermal endurance graph.79 Figure E.5 – Ageing times and temperatures in relation to thermal endurance graph.81 Table B.1 – Decision table.65Table C.1 – χ2-function.67 Table C.2 –t–function.67 Table C.3 – F-function, P = 0,05.69 Table C.4 – F-function, P = 0,005.71 Table D.1 – Ageing temperatures and ageing periods .73



60216-6 © IEC:2003 – 7 – INTERNATIONAL ELECTROTECHNICAL COMMISSION ____________ ELECTRICAL INSULATING MATERIALS – THERMAL ENDURANCE PROPERTIES –Part 6: Determination of thermal endurance indices (TI and RTE)
of an insulating material using the fixed time frame method FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) andexpenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 60216-6 has been prepared by subcommittee 15E, Methods test, of IEC technical committee 15: Insulating materials. The text of this standard is based on the following documents: FDIS Report on voting 15E/221/FDIS 15E/225/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.



60216-6 © IEC:2003 – 9 – IEC 60216, under the general title Electrical insulating materials – Thermal endurance properties, consists of the following parts: Part 1:
Ageing procedures and evaluation of test results Part 2:
Choice of test criteria Part 3:
Instructions for calculating thermal endurance characteristics Part 4:
Ageing ovens Part 5:
Determination of relative thermal endurance index (RTE) of an insulating material Part 6:
Determination of thermal endurance indices (TI and RTE) of an insulating material using the fixed time frame protocol The committee has decided that this publication remains valid until 2008. At this date, the publication will be
• reconfirmed; • withdrawn; • replaced by a revised edition, or • amended.



60216-6 © IEC:2003 – 11 – ELECTRICAL INSULATING MATERIALS – THERMAL ENDURANCE PROPERTIES –Part 6: Determination of thermal endurance indices (TI and RTE)
of an insulating material using the fixed time frame method 1 Scope This part of IEC 60216 specifies the experimental and calculation procedures for deriving the thermal endurance characteristics, temperature index (TI) and relative thermal endurance index (RTE) of a material using the “fixed time frame method (FTFM)”.
In this protocol, the ageing takes place for a small number of fixed times, using the appropriate number of ageing temperatures throughout each time, the properties of the specimens being measured at the end of the relevant time interval. This differs from the procedure of IEC 60216-1, where ageing is conducted at a small number of fixed temperatures, property measurement taking place after ageing times dependent on the progress of ageing. Both the TI and the RTE determined according to the FTFM protocol are derived from experimental data obtained in accordance with the instructions of IEC 60216-1 and IEC 60216-2, as modified in this standard. The calculation procedures and statistical tests are modified in relation to IEC 60216-3 and IEC 60216-5.
2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60212:1971, Standard conditions for use prior to and during the testing of solid electrical insulating materials IEC 60216-1:2001, Electrical insulating materials – Properties of thermal endurance – Part 1: Ageing procedures and evaluation of test results IEC 60216-2:1990, Guide for the determination of thermal endurance properties of electrical insulating materials – Part 2: Choice of test criteria IEC 60216-3:2002, Electrical insulating materials – Thermal endurance properties – Part 3: Instructions for calculating thermal endurance characteristics IEC 60216-4-1:1990, Guide for the determination of thermal endurance properties of electrical insulating materials – Part 4: Ageing ovens – Section 1: Single-chamber ovens IEC 60216-4-2:2000, Electrical insulating materials – Thermal endurance properties – Part 4-2: Ageing ovens – Precision ovens for use up to 300 °C



60216-6 © IEC:2003 – 13 – IEC 60216-4-3:2000, Electrical insulating materials – Thermal endurance properties – Part 4-3: Ageing ovens – Multi-chamber ovens
IEC 60216-5:2003, Electrical insulating materials − Thermal endurance properties – Part 5: Determination of relative thermal endurance index (RTE) of an insulating material IEC 60493-1:1974, Guide for the statistical analysis of ageing test data – Part 1: Methods based on mean values of normally distributed test results 3 Terms, definitions, symbols and abbreviated terms For the purposes of this document, the following terms, definitions, symbols and abbreviations apply. 3.1 Terms, abbreviations and definitions 3.1.1 assessed thermal endurance index
ATE
numerical value of the temperature in degrees Celsius, up to which the control material possesses known, satisfactory service performance in the specified application
NOTE 1 The ATE of a specific material may vary between different applications of the material. NOTE 2 ATE is sometimes referred to as “absolute” thermal endurance index. 3.1.2 ageing temperature temperature in degrees Celsius at which a group of specimens is thermally aged 3.1.3 end-point temperature temperature in degrees Celsius at which a specimen is considered to have reached its end-point after ageing for the specified time 3.1.4 candidate material material for which an estimate of the thermal endurance is required to be determined NOTE The determination is made by simultaneous thermal ageing of the material and a control material. 3.1.5 central second moment of a data group sum of the squares of the differences between the data values and the value of the group mean divided by the number of data in the group 3.1.6 95 % confidence limit statistical parameter, calculated from test data, which with 95 % confidence constitutes an upper or lower limit for the true value of a quantity estimated by statistical analysis NOTE 1 This implies that there is only 5 % probability that the true value of the quantity estimated is actually larger (or smaller) than the upper (or lower) confidence limit. NOTE 2 In other connections, confidence values other than 95 % may sometimes be used, e.g. in the linearity test for destructive test data.



60216-6 © IEC:2003 – 15 – 3.1.7 control material material with known assessed thermal endurance index (ATE), preferably derived from service experience, used as a reference for comparative tests with the candidate material 3.1.8 correlation coefficient number expressing the completeness of the relation between members of two data sets, equal to the covariance divided by the square root of the product of the variances of the sets NOTE 1 The value of its square is between 0 (no correlation) and 1 (complete correlation). NOTE 2 In this standard, the two data sets are the values of the independent variable and the means of the dependent variable groups. 3.1.9 correlation time of RTE estimated time to end-point of the control material at a temperature equal to its ATE in degrees Celsius 3.1.10 correlation time of TI hypothetical time to end-point used to calculate TI NOTE Its usual value is 20 000 h. 3.1.11 covariance of data sets for two sets of data with equal numbers of elements where each element in one set corres-ponds to one in the other, the sum of the products of the deviations of the corresponding members from their set means, divided by the number of degrees of freedom 3.1.12 degrees of freedom number of data values minus the number of parameter values 3.1.13 destructive test diagnostic property test, where the test specimen is irreversibly changed by the property measurement, in a way which precludes a repeated measurement on the same specimen 3.1.14 end-point line line parallel to the temperature axis intercepting the property axis at the end-point value 3.1.15 halving interval
HIC numerical value of the temperature interval in kelvin which expresses the halving of the time to end-point taken at a time equal to TI 3.1.16 regression analysis process of deducing the best fit line expressing the relation of corresponding members of two data groups by minimizing the sum of squares of deviations of members of one of the groups from the line



60216-6 © IEC:2003 – 17 – 3.1.17 regression coefficients coefficients of the equation derived by regression analysis 3.1.18 relative thermal endurance index RTE estimate of the thermal endurance of a candidate material, made by thermal ageing simultaneously with the control material, as described in this standard NOTE The value of RTE is the value of the temperature in degrees Celsius at which the estimated time to end-point of the candidate material is the same as the estimated time to end-point of the control material at a temperature equal to its ATE. 3.1.19 significance probability of a value of a statistical function greater than a specified value NOTE The value is equal to (1 – p) where p is the cumulative distribution function value. Significance is conventionally printed in upper case (P). 3.1.20 standard deviation square root of the variance of a data group or sub-group 3.1.21 standard error of an estimate of the true value of a data group property value of the standard deviation of the hypothetical sampling population of which the group property may be considered to be a member NOTE For an estimate of the group mean, the standard error is equal to the group standard deviation divided by the square root of the number of data in the group, and indicates the uncertainty in the estimate of thetrue value of the mean. This standard is concerned only with means and the difference between two means.
3.1.22 temperature index
TI
numerical value of the temperature in degrees Celsius derived from the thermal endurance relationship at a time of 20 000 h (or other specified time) 3.1.23 temperature group (of specimens) number of specimens being exposed together to thermal ageing at the same temperature in the same oven NOTE Where there is no risk of ambiguity, either temperature groups or test groups may be referred to simply as “groups”. 3.1.24 test group (of specimens)
number of specimens removed together from a temperature group for destructive testing NOTE Where there is no risk of ambiguity, either temperature groups or test groups may be referred to simply as “groups”. 3.1.25 thermal endurance graph graph in which the logarithm of the time to reach a specified end-point in a thermal endurance test is plotted against the reciprocal thermodynamic (absolute) test temperature



60216-6 © IEC:2003– 19 –3.1.26thermal endurance graph papergraph paper having a logarithmic time scale as the ordinate and values proportional to thereciprocal of the thermodynamic (absolute) temperature as the abscissaNOTE
The ordinate is in powers of ten (from 10 h to 100 000 h is often a convenient range). The abscissa isusually graduated in a non-linear (Celsius) temperature scale oriented with temperature increasing from left toright.3.1.27time group (of specimens)all test groups removed for testing at the same time3.1.28variance of a data groupsum of the squares of the deviations of the data from a reference level defined by one or moreparameters divided by the number of degrees of freedomNOTE
The reference level may, for example be a mean value (1 parameter) or a line (2 parameters, in this caseintercept on the axis of the independent variable and slope).3.2 Symbols and abbreviated termsThe following symbols are used in the calculations of Clauses 6, 7 and 12.SymbolDescriptionClauseaRegression coefficient: intercept of regression line with x-axis6.4.3bRegression coefficient: slope of regression line relative to y-axis6.4.3rbParameter derived from b for calculation of cYˆ6.5.3cParameter in calculation of χ26.5.1FF-distributed variance ratio for linearity test6.3.3, 6.5.2g, h, i, jIndexing parameters for regression calculations6.3, 6.4HICHalving interval7.1kNumber of ageing times6.1.1NTotal number of xij
values6.4.2niNumber of xij values in time groupi6.1.1PSignificance of the value of a statistical test functionAnnexes A,B, and CpeEnd-point property value6.3pghProperty value h in temperature group g (time group iimplied)6.3gpMean property value in temperature groupg (time group iimplied)6.3qBase of logarithms in calculation of χ26.5.1rNumber of temperature groups selected in time group i6.3.2r2Square of correlation coefficient6.4.3s2Total (non-regression) variance of x-values6.5.2



60216-6 © IEC:2003– 21 –SymbolDescriptionClause21gsVariance of property values in temperature group g (time groupiimplied)6.3.22asValue ofs2 adjusted to allow for acceptable non-linearity.6.5.22rsParameter derived from s2 for calculation of cYˆ6.5.3tStudent's t-distributed stochastic variable6.5.3TC, TCaLower confidence limit of TI or TIa (see 2as above)6.5.3tp, NValue of twith probability p andN degrees of freedom6.5.3xijValue ofx, index numberj , in time group i6.3.4xGeneral mean of x-values6.4.2cXXˆ,ˆEstimate ofx, and its confidence limit6.5.3yiValue of y for time groupi6.1.1yGeneral mean of y-values6.4.2cYYˆ,ˆEstimate ofy, and its confidence limit6.5.3zijReciprocal kelvin temperature for ijϑ6.1.1()y2µCentral 2nd moment of yvalues6.4.2νTotal number of property value
...

Questions, Comments and Discussion