EN IEC 61010-2-051:2021
(Main)Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-051: Particular requirements for laboratory equipment for mixing and stirring
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-051: Particular requirements for laboratory equipment for mixing and stirring
NEW!IEC 61010-2-051:2018 is available as IEC 61010-2-051:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61010-2-051:2018 is applicable to electrically operated laboratory equipment and its accessories for mechanical mixing and stirring, where mechanical energy influences the shape or size or homogeneity of materials and their accessories. Such devices can contain heating elements. It has the status of a group safety publication in accordance with IEC Guide 104. This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - adaptation of changes introduced by Amendment 1 of IEC 61010-1; - added tolerance for stability of AC voltage test equipment to Clause 6; - added required assessment for equipment intended to be used with flammable, hazardous, or toxic fluids to Clause 17. This Part 2-051 is intended to be used in conjunction with IEC 61010-1. It was established on the basis of the third edition (2010) and its Amendment 1 (2016).
Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regel- und Laborgeräte - Teil 2-051: Besondere Anforderungen an Laborgeräte zum Mischen und Rühren
Exigences de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 2-051 : Exigences particulières pour appareils de laboratoire utilisés pour mélanger et agiter
NEW!IEC 61010-2-051:2018 est disponible sous forme de IEC 61010-2-051:2018 RLV qui contient la Norme internationale et sa version Redline, illustrant les modifications du contenu technique depuis l'édition précédente.L’IEC 61010-2-051:2018 est applicable aux appareils de laboratoire électriques et à leurs accessoires, destinés à mélanger et à agiter, et qui, par l’énergie mécanique dispensée, modifient la forme, la taille ou l’homogénéité des matériaux et de leurs accessoires. De tels appareils peuvent contenir des éléments de chauffage. Elle a le statut d'une publication groupée de sécurité conformément au Guide IEC 104. Cette quatrième édition annule et remplace la troisième édition parue en 2015. Cette édition constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente: - adaptation des modifications introduites par l’Amendement 1 de l’IEC 61010-1; - ajout à l’Article 6 de la tolérance pour la stabilité du matériel d’essai en tension alternative; - ajout à l’Article 17 de l’appréciation du risque exigée pour le matériel destiné à être utilisé avec des fluides inflammables, dangereux ou toxiques. Cette partie 2-051 est destinée à être utilisée conjointement avec l'IEC 61010-1. Elle a été établie sur la base de la troisième édition (2010) et de son Amendement 1 (2016).
Varnostne zahteve za električno opremo za meritve, nadzor in laboratorijsko uporabo - 2-051. del: Posebne zahteve za laboratorijsko opremo za mešanje in premešavanje (IEC 61010-2-051:2018)
General Information
Relations
Overview
EN IEC 61010-2-051:2021 (Part 2-051) sets particular safety requirements for electrically operated laboratory equipment for mixing and stirring. This fourth edition updates the previous 2015 edition and aligns the Part 2-051 requirements with IEC 61010-1. It applies to devices where mechanical energy affects shape, size or homogeneity of materials and to accessories. Equipment covered can include heating elements and is intended for use in chemical and general laboratory environments.
This part is a group safety publication in accordance with IEC Guide 104 and is intended to be used in conjunction with IEC 61010-1. The standard clarifies testing, marking and documentation, protection against electrical and mechanical hazards, and introduces specific risk-assessment expectations for use with hazardous fluids.
Key Topics
- Scope and applicability: Electrically operated laboratory mixers, stirrers, impellers and related accessories; devices that may contain heating elements.
- Edition changes: Technical revisions include adaptation to Amendment 1 of IEC 61010-1, added tolerance for AC voltage test equipment stability, and a required risk assessment for use with flammable, hazardous or toxic fluids.
- Marking & documentation:
- Warnings for hand‑held mixers where operation could cause a hazard.
- Instructions for fixing stirring vessels when supplied as part of a system.
- Warnings against use in hazardous atmospheres or with materials outside the equipment design.
- Electrical protection and tests:
- AC voltage test equipment must maintain test voltage within ±5% during the test.
- Clauses from Part 1 remain applicable except where this Part 2-051 adds or replaces requirements.
- Mechanical hazards:
- Requirements addressing hazards from shafts, impellers and rotating parts extending into materials.
- Speed control design: if a single fault in an electronic speed control could create a hazard, means are required to interrupt power or prevent the hazard.
- Equipment (except hand‑held) should not change position during normal use.
- Risk assessment: New emphasis on assessing equipment intended for use with flammable, hazardous or toxic fluids.
Applications
EN IEC 61010-2-051:2021 is directly applicable to manufacturers, test engineers and laboratory managers responsible for:
- Design and production of laboratory mixers and stirrers (bench, overhead, and system-integrated units).
- Manufacturing and testing of accessories and stirring vessels that interface with mixers.
- Laboratory safety compliance in chemical, pharmaceutical and research facilities.
- Performing hazard analyses and conformity assessment to the IEC 61010 series requirements.
Benefits include clearer safety expectations, improved conformity testing, and reduced risk from electrical faults, mechanical failures, heating elements and misuse with hazardous fluids.
Related Standards
- IEC 61010-1 - General requirements for safety of electrical laboratory equipment (used in conjunction with Part 2-051).
- IEC 61010-2-010 - Particular requirements for equipment containing heating devices (relevant when mixers include heaters).
- IEC Guide 104 - Group safety publication guidance.
Manufacturers and laboratories should apply EN IEC 61010-2-051:2021 together with Part 1 to ensure comprehensive electrical and mechanical safety for mixing and stirring equipment.
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2021
Nadomešča:
SIST EN 61010-2-051:2015
Varnostne zahteve za električno opremo za meritve, nadzor in laboratorijsko
uporabo - 2-051. del: Posebne zahteve za laboratorijsko opremo za mešanje in
premešavanje (IEC 61010-2-051:2018)
Safety requirements for electrical equipment for measurement, control and laboratory
use - Part 2-051: Particular requirements for laboratory equipment for mixing and stirring
(IEC 61010-2-051:2018)
Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regel- und Laborgeräte - Teil 2
-051: Besondere Anforderungen an Laborgeräte zum Mischen und Rühren
(IEC 61010-2-051:2018)
Exigences de sécurité pour appareils électriques de mesurage, de régulation et de
laboratoire - Partie 2-051 : Exigences particulières pour appareils de laboratoire utilisés
pour mélanger et agiter (IEC 61010-2-051:2018)
Ta slovenski standard je istoveten z: EN IEC 61010-2-051:2021
ICS:
19.080 Električno in elektronsko Electrical and electronic
preskušanje testing
71.040.10 Kemijski laboratoriji. Chemical laboratories.
Laboratorijska oprema Laboratory equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN IEC 61010-2-051
NORME EUROPÉENNE
EUROPÄISCHE NORM
September 2021
ICS 19.080; 71.040.20 Supersedes EN 61010-2-051:2015 and all of its
amendments and corrigenda (if any)
English Version
Safety requirements for electrical equipment for measurement,
control and laboratory use - Part 2-051: Particular requirements
for laboratory equipment for mixing and stirring
(IEC 61010-2-051:2018)
Exigences de sécurité pour appareils électriques de Sicherheitsbestimmungen für elektrische Mess-, Steuer-,
mesurage, de régulation et de laboratoire - Partie 2-051 : Regel- und Laborgeräte -Teil 2-051: Besondere
Exigences particulières pour appareils de laboratoire Anforderungen an Laborgeräte zum Mischen und Rühren
utilisés pour mélanger et agiter (IEC 61010-2-051:2018)
(IEC 61010-2-051:2018)
This European Standard was approved by CENELEC on 2018-11-09. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61010-2-051:2021 E
European foreword
The text of document 66/642/CDV, future edition 4 of IEC 61010-2-051, prepared by IEC/TC 66
"Safety of measuring, control and laboratory equipment" was submitted to the IEC-CENELEC parallel
vote and approved by CENELEC as EN IEC 61010-2-051:2021.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2022-08-02
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2024-08-02
document have to be withdrawn
This document supersedes EN 61010-2-051:2015 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a Standardization Request given to CENELEC by the
European Commission and the European Free Trade Association, and supports essential
requirements of EU Directive(s) / Regulation(s).
For the relationship with EU Directive(s) / Regulation(s), see informative Annex ZZ, which is an
integral part of EN IEC 61010-2-051:2021/A11:2021.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 61010-2-051:2018 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards
indicated:
IEC 61010-2-010 NOTE Harmonized as EN IEC 61010-2-010
IEC 62061 NOTE Harmonized as EN 62061
ISO 13849 (series) NOTE Harmonized as EN ISO 13849 (series)
IEC 61010-2-051 ®
Edition 4.0 2018-10
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
GROUP SAFETY PUBLICATION
PUBLICATION GROUPÉE DE SÉCURITÉ
Safety requirements for electrical equipment for measurement, control, and
laboratory use –
Part 2-051: Particular requirements for laboratory equipment for mixing and
stirring
Exigences de sécurité pour appareils électriques de mesurage, de régulation, et
de laboratoire –
Partie 2-051: Exigences particulières pour appareils de laboratoire utilisés pour
mélanger et agiter
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 19.080; 71.040.20 ISBN 978-2-8322-6061-6
– 2 – IEC 61010-2-051:2018 © IEC 2018
CONTENTS
FOREWORD . 3
1 Scope and object . 5
2 Normative references. 5
3 Terms and definitions . 5
4 Tests . 5
5 Marking and documentation . 5
6 Protection against electric shock . 6
7 Protection against mechanical HAZARDS . 6
8 Resistance to mechanical stresses . 7
9 Protection against the spread of fire . 8
10 Equipment temperature limits and resistance to heat . 8
11 Protection against HAZARDS from fluids and solid foreign objects . 8
12 Protection against radiation, including laser sources, and against sonic and
ultrasonic pressure . 8
13 Protection against liberated gases and substances, explosion and implosion . 8
14 Components and subassemblies . 8
15 Protection by interlocks . 8
16 HAZARDS resulting from application . 9
17 RISK assessment . 9
Annexes . 9
Bibliography . 10
IEC 61010-2-051:2018 © IEC 2018 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR
MEASUREMENT, CONTROL, AND LABORATORY USE –
Part 2-051: Particular requirements for laboratory
equipment for mixing and stirring
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out
...
Frequently Asked Questions
EN IEC 61010-2-051:2021 is a standard published by CLC. Its full title is "Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-051: Particular requirements for laboratory equipment for mixing and stirring". This standard covers: NEW!IEC 61010-2-051:2018 is available as IEC 61010-2-051:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61010-2-051:2018 is applicable to electrically operated laboratory equipment and its accessories for mechanical mixing and stirring, where mechanical energy influences the shape or size or homogeneity of materials and their accessories. Such devices can contain heating elements. It has the status of a group safety publication in accordance with IEC Guide 104. This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - adaptation of changes introduced by Amendment 1 of IEC 61010-1; - added tolerance for stability of AC voltage test equipment to Clause 6; - added required assessment for equipment intended to be used with flammable, hazardous, or toxic fluids to Clause 17. This Part 2-051 is intended to be used in conjunction with IEC 61010-1. It was established on the basis of the third edition (2010) and its Amendment 1 (2016).
NEW!IEC 61010-2-051:2018 is available as IEC 61010-2-051:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61010-2-051:2018 is applicable to electrically operated laboratory equipment and its accessories for mechanical mixing and stirring, where mechanical energy influences the shape or size or homogeneity of materials and their accessories. Such devices can contain heating elements. It has the status of a group safety publication in accordance with IEC Guide 104. This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - adaptation of changes introduced by Amendment 1 of IEC 61010-1; - added tolerance for stability of AC voltage test equipment to Clause 6; - added required assessment for equipment intended to be used with flammable, hazardous, or toxic fluids to Clause 17. This Part 2-051 is intended to be used in conjunction with IEC 61010-1. It was established on the basis of the third edition (2010) and its Amendment 1 (2016).
EN IEC 61010-2-051:2021 is classified under the following ICS (International Classification for Standards) categories: 19.080 - Electrical and electronic testing; 71.040.20 - Laboratory ware and related apparatus. The ICS classification helps identify the subject area and facilitates finding related standards.
EN IEC 61010-2-051:2021 has the following relationships with other standards: It is inter standard links to EN 61010-2-051:2015, EN IEC 61010-2-051:2021/A11:2021. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN IEC 61010-2-051:2021 is associated with the following European legislation: EU Directives/Regulations: 2014/35/EU, 2014/53/EU; Standardization Mandates: M/511. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase EN IEC 61010-2-051:2021 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.
기사 제목: EN IEC 61010-2-051:2021 - 측정, 제어 및 실험실용 전기장비 안전 요구사항 - Part 2-051: 혼합 및 저어용 실험실장비를 위한 개별 요구사항 기사 내용: NEW! IEC 61010-2-051:2018은 IEC 61010-2-051:2018 RLV로 제공되며 이는 이전 판과 기술 콘텐츠에 대한 변경 사항을 모두 보여주는 국제 표준 및 레드라인 버전을 포함하고 있습니다. IEC 61010-2-051:2018은 기계적인 혼합과 저어에 대한 전기적으로 작동하는 실험실용 장비와 그 부속품에 적용되며, 기계적 에너지가 물질의 모양, 크기 또는 균질성에 영향을 주는 경우입니다. 이러한 장치에는 가열 요소가 포함될 수 있습니다. 이 표준은 IEC 가이드 104에 따른 그룹 안전 발행물의 지위를 갖습니다. 이 네 번째 판은 2015년에 출판된 제 3판을 취소하고 대체하는 것입니다. 이 판에는 다음과 같은 중요한 기술적 변경 사항이 이전 판과 비교하여 포함되어 있습니다: - IEC 61010-1의 팔찌 1에서 도입된 변경 사항 적용; - 6조에 교류 전압 시험장비의 안정성에 대한 허용오차 추가; - 17조에 인화성, 위험성 또는 유독한 유체와 함께 사용할 장비에 대한 필요한 평가 추가. 이 Part 2-051은 IEC 61010-1과 함께 사용하기 위해 사용됩니다. 이는 2010년 제 3판과 그 팔찌 1 (2016)을 기반으로합니다.
기사 제목: EN IEC 61010-2-051:2021 - 측정, 제어 및 실험실용 전기장비의 안전 요구 사항 - 제 2-051 부: 혼합 및 점성제 실험실 장비를 위한 특수 요구 사항 기사 내용: EN IEC 61010-2-051:2021 표준은 실험실에서 사용되는 전기식 혼합 및 점성제 장비와 관련 액세서리에 대한 안전 요구 사항을 명시한다. 이 표준은 2015년에 발표된 제 3판을 대체하는 제 4판으로, IEC 61010-1 표준의 변경 사항에 대한 적응과 AC 전압 시험 장비의 안정성에 대한 허용 오차 추가, 인화성, 유해성 또는 독성 유체와 함께 사용되는 장비에 대한 평가 요구 사항 등 여러 가지 기술적인 변경이 포함되어 있다. 이 표준은 IEC 61010-1 표준과 함께 사용되어야 한다.
The article discusses the availability of the EN IEC 61010-2-051:2021 standard, which outlines safety requirements for electrical equipment used in laboratories for mixing and stirring. The standard applies to equipment that uses mechanical energy to influence the shape, size, or homogeneity of materials and may contain heating elements. It is a revised edition that includes technical changes such as adapting to Amendment 1 of IEC 61010-1 and adding tolerance for stability of AC voltage test equipment. This standard is intended to be used in conjunction with IEC 61010-1 and is based on the third edition (2010) and its Amendment 1 (2016).
The article discusses the release of the EN IEC 61010-2-051:2021 standard, which specifies safety requirements for electrical equipment used in laboratories for mixing and stirring materials. This fourth edition of the standard replaces the previous edition published in 2015 and includes several technical changes, such as adaptations to amendments made to the IEC 61010-1 standard and the addition of tolerances for AC voltage test equipment stability and assessment requirements for equipment used with flammable, hazardous, or toxic fluids. The standard is meant to be used in conjunction with the IEC 61010-1 standard.
記事のタイトル:EN IEC 61010-2-051:2021 - 測定、制御、および実験室用電気機器の安全要件 - 第2-051部:混合および撹拌のための実験室用機器の特定の要件 記事の内容:EN IEC 61010-2-051:2021は、材料の形状やサイズ、均一性に機械エネルギーが影響を与える電気式実験室機器とそのアクセサリーに対する安全要件を規定しています。この第4版は、2015年に発行された第3版を取り消し、置き換えるものであり、IEC 61010-1の改正に対する適応やAC電圧試験機の安定性の許容差の追加、可燃性、有害性、または有毒性の流体と使用する機器の評価要件など、いくつかの技術的な変更が含まれています。この規格はIEC 61010-1規格と組み合わせて使用することが意図されています。
記事タイトル:EN IEC 61010-2-051:2021 - 測定、制御、および実験室用電気機器の安全要求事項 - Part 2-051: 混合および攪拌のための実験室機器の特定要件 記事内容:NEW! IEC 61010-2-051:2018は、IEC 61010-2-051:2018 RLVとして利用可能であり、それにはInternational StandardとRedlineバージョンが含まれており、それは技術内容の以前の版との比較でのすべての変更を示しています。IEC 61010-2-051:2018は、機械的な混合および攪拌に対し電気的に動作する実験室用機器とその付属品に適用され、機械エネルギーが材料の形状、サイズ、均一性に影響を与える場合に使用されます。このような装置には加熱要素が含まれることがあります。この基準は、IECガイド104に従ったグループの安全発行物の地位を持っています。この第4版は、2015年に発行された第3版を取り消し、置き換えるものです。この版には、以下のような重要な技術的変更が前版と比較して含まれています:- IEC 61010-1の改正1による変更の適用;- 第6条に交流電圧試験装置の安定性の公差を追加;- 第17条に引火性、有害性、または有毒な液体と使用する装置に対する必要な評価を追加。このPart 2-051は、IEC 61010-1と併用するために使用されます。これは第3版(2010年)およびその改正1(2016年)に基づいています。








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...