prEN IEC 60598-2-3:2026
(Main)Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting
- Status
- Not Published
- Publication Date
- 08-Feb-2028
- Technical Committee
- CLC/TC 34 - Lighting
- Current Stage
- 4020 - Enquiry circulated - Enquiry
- Start Date
- 04-Sep-2026
- Due Date
- 19-Dec-2025
- Completion Date
- 19-Dec-2025
prEN IEC 60598-2-3:2026 is a CLC draft standard for luminaires for road and street lighting, tunnel lighting, and column-integrated luminaires. It specifies the particular safety and construction requirements for these luminaires when used with electric light sources at supply voltages not exceeding 1 000 V, mainly for manufacturers, test laboratories, and certification bodies.
What does prEN IEC 60598-2-3:2026 specify?
prEN IEC 60598-2-3:2026 specifies the special requirements for luminaires used on roads, streets, other public outdoor lighting applications, tunnels, and certain column-integrated luminaires. It is used together with IEC 60598-1, and it adds requirements where outdoor mounting, wind load, impact, corrosion, and access to equipment create extra safety issues.
The document is organized into Clauses 1 to 17, covering scope, normative references, terms, general requirements, classification, marking, construction, wiring, earthing, protection against electric shock, ingress protection, insulation and electric strength, creepage and clearance, endurance and thermal tests, resistance to heat/fire/tracking, and terminals.
| Annex | What it covers |
|---|---|
| Annex AAA | Drag coefficient measurement |
| Annex AAB | Schedule of amended clauses containing more serious or critical requirements that may require retesting |
What are the key requirements of prEN IEC 60598-2-3:2026?
This part of IEC 60598 is built on Part 1, but it adds tests and construction rules for outdoor and column-integrated luminaires. In practice, the most important points are about mounting information, weather protection, wind resistance, glass safety, wiring security, and the special construction of column-integrated luminaires.
Relationship with Part 1 and test sequence
Clause 4 says this document is applied with the general requirements of Part 1, and the clause order shall be followed as listed. For products already assessed to the previous edition, full type testing is not required - only the amended clauses listed in Annex AAB are reviewed. For column-integrated luminaires, the document also allows testing of the relevant parts only when the size of the sample makes that necessary.
This matters because it defines how conformity assessment is done. Manufacturers and labs need to know whether they are testing a complete luminaire or only the changed parts, and certification teams need to know which clause changes can trigger retesting.
Marking and installation instructions
Clause 6 requires installation instructions to state practical information such as operating position, fixing method, mass, overall dimensions, wind-exposed projected area when mounting height is above 8 m, suitable suspension wire area range, indoor-use suitability, connection compartment dimensions, tightening torque for fixing bolts or screws, maximum mounting height relevant to falling glass particles, and tunnel-luminaire suitability. Adjustable lampholders and optical parts also need suitable reference marks.
This is the information installers need to mount the luminaire safely and to choose the right support, fasteners, and cable arrangement. It also helps buyers check whether a product fits the project conditions before installation starts.
Weather protection, attachment, and wind load
Clause 7 requires at least IPX3 moisture protection for all luminaires, with IPX5 required for tunnel-lighting luminaires and translucent covers of column-integrated luminaires. Column-integrated luminaires have extra ingress-protection levels for parts below and above 2.5 m. The clause also requires span-wire suspensions to clamp without damaging the wire, and the attachment means must support the mass of the luminaire and resist wind and vibration.
Clause 7.104 gives the static load test for mast-arm or post-top mounted luminaires. The test uses the projected surface, a drag coefficient, and a wind speed based on mounting height, with a 10 minute load application. The acceptance criteria are no visible failure affecting safety, no excessive permanent deformation, and no rotation at the attachment point.
This is the core outdoor robustness check. It tells designers what the luminaire must survive on the pole or arm, and it tells buyers and specifiers that the product has been assessed for realistic wind loading.
Glass covers and impact resistance
Clause 7.106 adds specific safety rules for glass covers, linked to mounting height and tunnel use. A glass cover may need to fracture into small pieces, have high impact resistance, or retain fragments if it breaks. The document also requires the protection method to be declared.
For high-impact glass, Clause 7.106.3 uses the IEC 62262 impact code, with IEC/TR 62696 and the hammer apparatus from IEC 60068-2-75. The test is applied to the fully assembled luminaire and checks that the glass does not break under the specified impacts. For fragmenting glass, the document gives a particle-count method and associated figures for where to strike and how to count particles.
This matters because glass breakage can create injury risk in streets, roads, and tunnels. The standard forces the manufacturer to choose a declared protection method and prove it with a defined test.
Column-integrated luminaires
Clauses 7.107 to 7.110 add rules for the connection compartment, structural design, corrosion resistance, the door opening, and the cable entry. The connection compartment must have enough space for terminals, protective devices, cable looping, and any connection box, with corrosion-resistant fixing means. The door opening is impact tested, must remain operational, and must not reduce the IP protection level. The cable entry slot and cable path also have minimum dimensions and must avoid sharp edges and obstructions.
These clauses address maintenance access and cable management in a product that combines the luminaire and the supporting column. For projects using column-integrated luminaires, they are the main design and inspection points.
Wiring, earthing, and terminals
Clause 8 requires cord anchorage where supply-cable mass would otherwise strain the terminals. Clause 9 requires the fixed part of the earthing terminal to be designed so it cannot rotate when the clamping part moves. Clause 16 requires supply terminals to accept conductors with nominal cross-sectional areas of at least 1 mm².
This matters for safe installation and long-term reliability. The cable must not pull on electrical connections, the protective earth must remain secure, and the terminals must accept the conductor sizes used in practice.
Thermal testing and glass temperature limits
Clause 14 adjusts thermal testing for outdoor luminaires by deducting 10 °C from measured temperatures when applying Part 1 limits, to reflect natural air movement outdoors. For indoor-use luminaires, that deduction is not applied. Glass covers also have to stay within declared thermal limits, including minimum and maximum temperature and maximum temperature difference across the glass.
This helps ensure the test conditions match the intended environment. It is especially relevant when a luminaire can be used outdoors but may also be offered for indoor locations.
What terms does prEN IEC 60598-2-3:2026 define?
The document adds several terms that are specific to suspended, pole-mounted, and column-integrated luminaires.
- Span wire - the wire between main supports that carries the mass of the complete installation, including several luminaires and supply cables if needed.
- Suspension wire - the wire attached to the span wire that carries the mass of the luminaire.
- Stay wire - a tensioned wire between main supports used to limit lateral and rotary movement of suspended luminaires.
- Column-integrated luminaire - a lighting system formed by a luminaire integrated in a lighting column fixed in the ground.
- Lighting column - the support that holds one or more luminaires, made of a post and possibly an extension piece and bracket.
- Nominal height - the height reference used for column-integrated luminaires, measured from the point of entry of the external part or from the bottom of the flange plate.
- Tunnel luminaire - a luminaire for tunnel lighting mounted directly on, or on frames fixed to, the tunnel wall or ceiling.
Who uses prEN IEC 60598-2-3:2026?
Manufacturers of road, street, tunnel, and column-integrated luminaires use this standard for product design and type testing. Test laboratories use it to set up wind-load, ingress-protection, impact, thermal, and wiring tests. Certification bodies and conformity assessment teams use it to judge whether a luminaire meets the relevant safety requirements.
It is also relevant to lighting designers, municipal buyers, and infrastructure specifiers who need to choose products for poles, arms, span wires, tunnel walls, or integrated columns. For them, the standard helps define the information that must be available before installation and acceptance.
What changed in prEN IEC 60598-2-3:2026 from the previous edition?
prEN IEC 60598-2-3:2026 is the fourth edition and replaces the third edition published in 2002 together with Amendment 1 published in 2011. The stated changes are structural alignment with IEC 60598-1, more detailed glass breakage tests, and modified requirements for high-impact glass.
Subclause 7.106.3 is identified in Annex AAB as a more onerous requirement than in the previous edition. In practice, that means some products certified to the earlier edition may need retesting when certification is updated.
Which standards are used with prEN IEC 60598-2-3:2026?
- IEC 60598-1:2024 - the base general standard that this part is used with for general requirements and tests.
- IEC 60068-2-75 - provides the hammer-test method used for impact testing of glass covers and the door of column-integrated luminaires.
- IEC 62262:2002 and IEC 62262:2002/AMD1:2021 - provide the IK code impact classification used for high-impact glass.
- IEC/TR 62696 - supports application of the IK code in the glass impact test.
- ISO 4354:2009 - cited in Annex AAA as the reference basis for drag-coefficient measurement.
What does the prEN IEC 60598-2-3:2026 document contain?
The document contains installation information requirements, construction rules, special tests for wind load and impact, glass-cover test methods, and additional requirements for column-integrated luminaires. It includes a static wind-force test with a formula for load calculation, a table for cord-anchorage pull and torque, and figures showing the wind-test loading method and the particle-counting area for glass breakage.
It also provides procedures for checking IP protection, thermal performance, corrosion resistance, and terminal suitability. Annex AAA describes drag-coefficient measurement in a wind tunnel, and Annex AAB identifies amended clauses that may require retesting in product certification.
Relations
- Effective Date
- 23-Apr-2024
- Effective Date
- 23-Apr-2024
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.

UL Solutions
Global safety science company with testing, inspection and certification.
Sponsored listings
Frequently Asked Questions
prEN IEC 60598-2-3:2026 is a draft published by CLC. Its full title is "Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting". This standard covers: Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting
Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting
prEN IEC 60598-2-3:2026 is classified under the following ICS (International Classification for Standards) categories: 29.140.40 - Luminaires; 93.080.30 - Road equipment and installations. The ICS classification helps identify the subject area and facilitates finding related standards.
prEN IEC 60598-2-3:2026 has the following relationships with other standards: It is inter standard links to EN 60598-2-3:2003/A1:2011, EN 60598-2-3:2003. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
prEN IEC 60598-2-3:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/35/EU; Standardization Mandates: M/511. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
prEN IEC 60598-2-3:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 2 FOREWORD
- 3 1 Scope
- 4 2 Normative references
- 5 3 Terms and definitions
- 6 4 General requirements
- 7 5 Classification of luminaires
- 8 6 Marking
- 9 7 Construction
- 10 8 External and internal wiring
- 11 9 Provisions for earthing
- 12 10 Protection against electric shock
- 13 11 Resistance to dust, solid objects and moisture
- 14 12 Insulation resistance and electric strength, touch current and protective conductor 15 current
- 16 13 Creepage distances and clearances
- 17 14 Endurance tests and thermal tests
- 18 15 Resistance to heat, fire and tracking
- 19 16 Screw terminals
- 20 17 Screwless terminals and electrical connections
- 21 Annex AAA (informative) Drag coefficient measurement
- 22 Annex AAB (normative) Schedule of amended clauses containing more serious or 23 critical requirements which require products to be retested
- 25 Figure 1 – Different procedures for the static wind-force test
- 26 Figure 2 – Counting particles at the edge of the square
29 INTERNATIONAL ELECTROTECHNICAL COMMISSION 30 ____________ 31 32 LUMINAIRES – 33 34 Part 2-3: Particular requirements – 35 Luminaires for road and street lighting 36 37 38 39 FOREWORD 40 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising 41 all national electrotechnical committees (IEC National Committees). The object of IEC is to promote 42 international co-operation on all questions concerning standardization in the electrical and electronic fields. To 43 this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, 44 Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC 45 Publication(s)"). Their preparation is entrusted to technical committees; any IEC National Committee interested 46 in the subject dealt with may participate in this preparatory work. International, governmental and non - 47 governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely 48 with the International Organization for Standardization (ISO) in accordance with conditions determined by 49 agreement between the two organizations.
50 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international 51 consensus of opinion on the relevant subjects since each technical committee has representation from all 52 interested IEC National Committees.
53 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National 54 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC 55 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any 56 misinterpretation by any end user.
57 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications 58 transparently to the maximum extent possible in their national and regional publications. Any divergence 59 between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in 60 the latter.
61 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity 62 assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any 63 services carried out by independent certification bodies.
64 6) All users should ensure that they have the latest edition of this publication.
65 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and 66 members of its technical committees and IEC National Committees for any personal injury, property damage or 67 other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and 68 expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC 69 Publications.
70 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is 71 indispensable for the correct application of this publication.
72 9) IEC draws attention to the possibility that the implementation of this document may involve the use of (a) 73 patent(s). IEC [takes no position concerning the evidence, validity or applicability of any claimed patent rights 74 in respect thereof. As of the date of publication of this document, IEC had not received notice of (a) patent(s), 75 which may be required to implement this document. However, implementers are cautioned that this may not 76 represent the latest information, which may be obtained from the patent database available at 77 https://patents.iec.ch. IEC shall not be held responsible for identifying any or all such patent rights. 78 79 IEC 60598-2-3 has been prepared by subcommittee 34D: Luminaires, of IEC technical 80 committee 34: Lighting. It is an International Standard.
81 This fourth edition cancels and replaces the third edition published in 2002 and amendment 82 one published in 2011. This edition constitutes a technical revision.
83 This edition includes the following significant technical changes with respect to the previous 84 edition:
85 a) the clause numbers and structure have been aligned with those of IEC 60598-1.
86 b) more detailed glass breakage tests have been added.
87 c) requirements for high impact glass has been modified. Subclause 7.106.3 is now listed in 88 Annex AAB being considered more onerous compared with the last edition.
89 The text of this International Standard is based on the following documents:
Draft Report on voting
XX/XX/FDIS XX/XX/RVD 90 91 Full information on the voting for its approval can be found in the report on voting indicated in 92 the above table.
93 The language used for the development of this International Standard is English.
94 This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in 95 accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, and the 96 ISO/IEC Directives, JTC 1 Supplement available at www.iec.ch/members_experts/refdocs. 97 The main document types developed by IEC are described in greater detail at 98 www.iec.ch/publications.
99 This Part 2-3 is to be used in conjunction with the latest edition of IEC 60598-1 and its 100 amendment(s). It was established on the basis of the tenth edition (2024) of that standard. 101 102 NOTE When “Part 1” is mentioned in this document, it refers to IEC 60598 -1.
103 104 Where this document states "addition", "modification" or "replacement", the relevant text of 105 Part 1 is to be adapted accordingly.
106 107 Subclauses, additional to those in Part 1 are numbered starting from 101; supplementary 108 annexes are entitled AAA, AAB, etc.
109 110 A list of all parts in the IEC 60598 series, published under the general title Luminaires can be 111 found on the IEC website.
112 113 The committee has decided that the contents of this document will remain unchanged until the 114 stability date indicated on the IEC website under webstore.iec.ch in the data related to the 115 specific document. At this date, the document will be 116 • reconfirmed, 117 • withdrawn, 118 • replaced by a revised edition, or 119 • amended.
122 LUMINAIRES – 123 124 Part 2-3: Particular requirements – 125 Luminaires for road and street lighting 126 127 128 129 1 Scope 130 This part of IEC 60598 specifies requirements for:
131 − luminaires for road, street lighting and other public outdoor lighting applications; 132 − tunnel lighting; 133 − column-integrated luminaires with a minimum total height above normal ground level of 134 2,5 m; 135 and for use with electric light sources on supply voltages not exceeding 1 000 V.
136 NOTE Where the term “luminaire” is used within this document it means luminaire(s) for road and street lighting. 137 138 2 Normative references 139 This clause of Part 1 applies with the following additions:
140 IEC 60068-2-75, Environmental testing – Part 2-75: Tests – Test Eh: Hammer tests 141 IEC 60598-1:2024, Luminaires - Part 1: General requirements and tests 142 IEC 62262: 2002, Degrees of protection provided by enclosures for electrical equipment 143 against external mechanical impacts (IK code) 144 IEC 62262:2002/AMD1:2021 145 IEC/TR 62696, Luminaires – Application of the IK code IEC62262 146 3 Terms and definitions 147 For the purposes of this document, the terms and definitions given in Part 1 applies with the 148 following additions:
149 ISO and IEC maintain terminology databases for use in standardization at the following 150 addresses:
151 • IEC Electropedia: available at https://www.electropedia.org/ 152 • ISO Online browsing platform: available at https://www.iso.org/obp3.101 153 3.101 154 span wire 155 wire between main supports which carries the mass of the complete installation.
156 NOTE This can include several luminaires, supply cables and a stay wire.
157 3.102 158 suspension wire 159 wire attached to the span wire and carrying the mass of the luminaire 160 3.103 161 stay wire 162 tensioned wire between main supports to limit lateral and rotary movement of the suspended 163 luminaires 164 3.104 165 column-integrated luminaire 166 lighting system formed with a luminaire integrated in a lighting column fixed in the ground 167 3.105 168 lighting column 169 support intended to hold one or more luminaires, consisting of one or more parts in the form 170 of a post, possibly an extension piece, and if necessary, a bracket.
...