Nuclear power plants - Control rooms - Design

IEC 60964:2009 provides functional design requirements to be used in the design of the main control room of a nuclear power plant to meet operational and safety requirements. Also provides functional interface requirements which relate to control room staffing, operating procedures, and the training programmes which, together with the human-machine interface, constitute the control room system. This new edition takes into account the fact that software engineering techniques advanced significantly in the intervening years and introduces consistency with the latest revisions of relevant IAEA documents.

Kernkraftwerke - Warten - Auslegung

Centrales nucléaires de puissance - Salles de commande - Conception

La CEI 60964:2009 établit des exigences fonctionnelles pour la conception des salles de commande des centrales nucléaires de puissance afin de respecter les exigences de conduite et de sûreté. Présente aussi les exigences d'interface fonctionnelles en rapport avec la structure de l'équipe de salle de commande, les procédures de conduite et le programme de formation qui sont en association avec l'interface homme-machine, les constituants du système de salle de commande. Cette nouvelle édition prend en compte le fait que les techniques de génie logiciel ont progressé de façon significative ces dernières années et introduit de la cohérence avec les dernières révisions des documents de l'AIEA pertinents.

Jedrske elektrarne - Nadzorne sobe - Zasnova (IEC 60964:2009)

Ta mednarodni standard vzpostavlja zahteve za vmesnik človek - stroj v glavnih nadzornih sobah jedrskih elektrarn. Standard tudi vzpostavlja zahteve za izbiro funkcij, vidike zasnove in organizacijo vmesnika človek -stroj ter postopke, ki se bodo sistematično uporabljali za preverjanje in potrjevanje funkcionalne zasnove. Te zahteve odsevajo uporabo inženirskih načel glede človeških dejavnikov, kot se uporabljajo za vmesnik človek-stroj med normalnimi in nenormalnimi pogoji v elektrarni. Ta standard ne zajema nadzornih točk za posebne namene ali običajno nespremljanih nadzornih točk, kot so točke, zagotovljene za operacije zaustavitve izvedene izven glavne nadzorne sobe, ali za rokovanje z radioaktivnimi odpadki, ali objekte za ukrepanje ob nesreči. Iz obsega uporabe tega standarda je izvzeta natančna zasnova opreme. Glavni namen tega standarda je zagotoviti zahteve glede funkcionalne zasnove, ki se uporabljajo pri načrtovanju glavne nadzorne sobe jedrske elektrarne, tako da ustreza operativnim in varnostnim zahtevam. Ta standard tudi predpisuje zahteve glede funkcionalnega vmesnika, ki se nanašajo na kadrovsko strukturo nadzorne sobe, operativne postopke in programme usposabljanja, ki skupaj z vmesnikom človek-stroj tvorijo sistem nadzorne sobe. Ta standard je namenjen uporabi za nove nadzorne sobe, katerih načrtovanje konstrukcije se prične po objavi tega standards. Če se želi uporabiti za obstoječo nadzorno sobo, je potrebna posebna previdnost, da osnova načrta ohrani konsistentnost.

General Information

Status
Withdrawn
Publication Date
11-Mar-2010
Withdrawal Date
28-Feb-2013
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
17-Jun-2022
Completion Date
17-Jun-2022

Relations

Buy Standard

Standard
EN 60964:2010
English language
42 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2010
Jedrske elektrarne - Nadzorne sobe - Zasnova (IEC 60964:2009)
Nuclear power plants - Control rooms - Design (IEC 60964:2009)
Kernkraftwerke - Warten - Auslegung (IEC 60964:2009)
Centrales nucléaires de puissance - Salles de commande - Conception (CEI
60964:2009)
Ta slovenski standard je istoveten z: EN 60964:2010
ICS:
27.120.20 Jedrske elektrarne. Varnost Nuclear power plants. Safety
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 60964
NORME EUROPÉENNE
March 2010
EUROPÄISCHE NORM
ICS 27.120.20
English version
Nuclear power plants -
Control rooms -
Design
(IEC 60964:2009)
Centrales nucléaires de puissance -  Kernkraftwerke -
Salles de commande - Warten -
Conception Auslegung
(CEI 60964:2009) (IEC 60964:2009)

This European Standard was approved by CENELEC on 2010-03-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: Avenue Marnix 17, B - 1000 Brussels

© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60964:2010 E
Foreword
The text of the International Standard IEC 60964:2009, prepared by SC 45A, Instrumentation and
control of nuclear facilities, of IEC TC 45, Nuclear instrumentation, was submitted to the CENELEC
formal vote for acceptance as a European Standard and was approved by CENELEC as EN 60964 on
2010-03-01.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented

at national level by publication of an identical

national standard or by endorsement
(dop) 2011-03-01
– latest date by which the national standards conflicting

with the EN have to be withdrawn
(dow) 2013-03-01
Annex ZA has been added by CENELEC.
As stated in the nuclear safety Directive 2009/71/EURATOM, Chapter 1, Article 2, Item 2, Member
States are not prevented from taking more stringent safety measures in the subject-matter covered by
the Directive, in compliance with Community law. In a similar manner, this European Standard does
not prevent Member States from taking more stringent nuclear safety measures in the subject-matter
covered by this European Standard.”
__________
Endorsement notice
The text of the International Standard IEC 60964:2009 was approved by CENELEC as a European
Standard without any modification.
__________
– 3 – EN 60964:2010
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE  Where an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
Publication Year Title EN/HD Year
IEC 60709 - Nuclear power plants - Instrumentation and EN 60709
-
control systems important to safety -
Separation
IEC 60780 - Nuclear power plants - Electrical equipment of - -
the safety system - Qualification
IEC 60960 - Functional design criteria for a safety - -
parameter display system for nuclear power
stations
IEC 60965 - Nuclear power plants - Control rooms - - -
Supplementary control points for reactor
shutdown without access to the main control
room
IEC 60980 - Recommended practices for seismic - -
qualification of electrical equipment of the
safety system for nuclear generating stations
IEC 61225 - Nuclear power plants - Instrumentation and - -
control systems important to safety -
Requirements for electrical supplies
-
IEC 61226 - Nuclear power plants - Instrumentation and EN 61226
control important to safety - Classification of
instrumentation and control functions
IEC 61227 - Nuclear power plants - Control rooms - - -
Operator controls
IEC 61513 - Nuclear power plants - Instrumentation and - -
control for systems important to safety -
General requirements for systems
IEC 61771 - Nuclear power plants - Main control-room - - -
Verification and validation of design
IEC 61772 - Nuclear power plants - Control rooms - - -
Application of visual display units (VDUs)
IEC 61839 - Nuclear power plants - Design of control rooms - -
- Functional analysis and assignment
IEC 62241 - Nuclear power plants - Main control room - - -
Alarm functions and presentation

Publication Year Title EN/HD Year
ISO 11064 Series Ergonomic design of control centres - -
IAEA NS-G-1.3 - Instrumentation and control systems important - -
to safety in nuclear power plants
IAEA NS-G-1.9 - Design of the reactor coolant systems and - -
associated system in nuclear power plants
IAEA NS-G-1.11 - Protection against internal hazards other than - -
fires and explosions in the design of nuclear
power plants : safety guide
IEC 60964 ®
Edition 2.0 2009-02
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Nuclear power plants – Control rooms – Design

Centrales nucléaires de puissance – Salles de commande – Conception

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
W
CODE PRIX
ICS 27.120.20 ISBN 2-8318-1031-4
– 2 – 60964 © IEC:2009
CONTENTS
FOREWORD.4
INTRODUCTION.6
1 Scope and object.8
2 Normative references .8
3 Terms and definitions .9
4 Standard use.12
5 Design principles for the main control room .16
5.1 Main objectives of the main control room.16
5.2 Functional design objectives of the main control room.16
5.3 Safety principles.16
5.4 Availability principles.16
5.5 Human factors engineering principles.17
5.6 Utility operating principles .17
5.7 Relationship with other control and management centres .17
5.8 Operational experience .18
6 Functional design of the main control room .18
6.1 General .18
6.2 Functional analysis.18
6.2.1 General .18
6.2.2 Identification of functions.18
6.2.3 Information flow and processing requirements .18
6.3 Assignment of functions .19
6.3.1 General .19
6.3.2 Operator capabilities .19
6.3.3 I&C system processing capabilities.20
6.4 Verification of function assignment .20
6.4.1 General .20
6.4.2 Process .20
6.5 Validation of function assignment .21
6.5.1 General .21
6.5.2 Process .21
6.5.3 General evaluation criteria for validation.21
6.6 Job analysis .21
7 Functional design specification.22
7.1 General .22
7.2 Provision of data base on human capabilities and characteristics .22
7.3 Location, environment and protection .22
7.3.1 Location .22
7.3.2 Environment .22
7.3.3 Protection.23
7.4 Space and configuration.24
7.4.1 Space.24
7.4.2 Configuration.24
7.5 Panel layout .25
7.5.1 Priority.25
7.5.2 Positioning on control desks and panels .25

60964 © IEC:2009 – 3 –
7.5.3 Mirror image layout.25
7.6 Location aids.25
7.6.1 Grouping of display information and controls .25
7.6.2 Nomenclature .26
7.6.3 Coding.26
7.6.4 Labelling.27
7.7 Information and control systems .27
7.7.1 General .27
7.7.2 Information functions .28
7.7.3 Control functions .31
7.8 Control-display integration.32
7.9 Communication systems.32
7.9.1 General .32
7.9.2 Verbal communication systems.33
7.9.3 Non-verbal communication systems.34
7.10 Other requirements .34
7.10.1 Power supplies .
...

Questions, Comments and Discussion