IEC 62724:2013
(Main)Railway applications - Fixed installations - Electric traction - Insulating synthetic rope assemblies for support of overhead contact lines
General Information
- Abstract
IEC 62724:2013 specifies the requirements of insulating synthetic rope assemblies and is applicable to electric traction overhead contact lines for railways, light railways, tramways, trolleybuses and other systems. This standard establishes requirements and characteristics of the rope, test methods and checking procedures to be used with the insulating synthetic ropes, together with the ordering and delivery requirements.
- Status
- Published
- Publication Date
- 03-Dec-2013
- Technical Committee
- TC 9 - Electrical equipment and systems for railways
- Drafting Committee
- PT 62724 - TC 9/PT 62724
- Current Stage
- PPUB - Publication issued
- Start Date
- 04-Dec-2013
- Completion Date
- 15-Jan-2014
Overview
IEC 62724:2013 is an international standard developed by the International Electrotechnical Commission (IEC) that addresses the use of insulating synthetic rope assemblies for supporting overhead contact lines in railway applications. These assemblies provide both mechanical support and electrical insulation within various electric traction environments such as railways, light railways, tramways, and trolleybus systems. By specifying requirements for the properties of ropes, test methods, and verification procedures, IEC 62724:2013 supports increased operational reliability, safety, and long-term performance of railway electrical infrastructure.
Key Topics
IEC 62724:2013 covers a wide scope of technical and operational aspects related to insulating synthetic ropes used in overhead contact systems. The main topics include:
- General requirements and characteristics: Outlining key properties of both core and sheath materials, drawing distinctions between polyester and polyaramid fibres for performance under various operational conditions.
- Electrical performance: Specification for insulation voltage ratings, creepage distances, and behaviour under polluted and extreme environmental conditions.
- Mechanical requirements: Definitions of minimum breaking loads, permissible tensile loads, endurance under cycling loads, and performance under specific directional stress.
- Environmental and fire safety considerations: Guidelines for ensuring resistance to pollution, corrosion, UV degradation, and fire hazards, especially in confined spaces like tunnels and stations.
- Testing procedures: Detailed descriptions of type tests, endurance tests, flammability tests, and methods for routine and sampling tests to ensure product quality and compliance.
- Product identification and documentation: Requirements for marking, traceable identification, and delivery documentation to support traceability and maintenance.
Applications
The use of insulating synthetic rope assemblies under IEC 62724:2013 brings advancements in the design and installation of overhead contact systems for various transport modes. Key application areas are:
- Railways and tramways: Supporting contact wires, catenary cables, and mid-point anchors where both insulation and mechanical durability are required.
- Trolleybus systems: Used as dropper cables, noise and vibration dampers, and various suspensions such as delta, bridle, and pulley assemblies.
- Urban transit infrastructure: Particularly suited to harsh environments, including high pollution or coastal locations, due to their resistance to corrosion, pollution, and UV radiation.
- Specialized structures: Employed in systems using glass reinforced polymer (GRP) cantilevers, as well as installations in tunnels and stations, where additional fire and tracking resistance is critical.
- Quality assurance and maintenance: The standard provides directives for installation, maintenance, and periodic inspection, supporting the infrastructure’s operational continuity.
Adherence to this standard facilitates improved safety, reduced maintenance needs, and enhanced service life of overhead contact lines by ensuring that assemblies are engineered, tested, and labeled according to internationally recognized criteria.
Related Standards
IEC 62724:2013 references and aligns with a range of other international standards relevant to railway electrification and material performance:
- IEC 60913:2013 – Railway applications – Fixed installations – Electric traction overhead contact lines
- IEC 61109:2008 – Insulators for overhead lines – Composite suspension and tension insulators for A.C. systems with a nominal voltage greater than 1 000 V
- IEC 62217:2012 – Polymeric HV insulators for indoor and outdoor use – General definitions, test methods, and acceptance criteria
- IEC 62497-1:2010 – Railway applications – Insulation coordination – Basic requirements for clearances and creepage distances
- IEC 60695-11-10:2013 – Fire hazard testing – Test flames for assessing flammability
- IEC 62498-2 – Railway applications – Environmental conditions for equipment
- ISO 4892-2:2006 – Plastics – Methods of exposure to laboratory light sources for material testing
These standards together form a robust framework for ensuring the performance, safety, and reliability of synthetic rope assemblies in demanding railway environments. Ensuring compliance with IEC 62724:2013 enables operators and manufacturers to meet international best practices for fixed installation electric traction systems.
Get Certified
Connect with accredited certification bodies for this standard
IRIS Certification (UNIFE)
International Railway Industry Standard certification.

TÜV SÜD Rail GmbH
TÜV SÜD railway certification services.

Bureau Veritas Railway Certification
Railway and transportation certification.
Sponsored listings
Frequently Asked Questions
IEC 62724:2013 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Railway applications - Fixed installations - Electric traction - Insulating synthetic rope assemblies for support of overhead contact lines". This standard covers: IEC 62724:2013 specifies the requirements of insulating synthetic rope assemblies and is applicable to electric traction overhead contact lines for railways, light railways, tramways, trolleybuses and other systems. This standard establishes requirements and characteristics of the rope, test methods and checking procedures to be used with the insulating synthetic ropes, together with the ordering and delivery requirements.
IEC 62724:2013 specifies the requirements of insulating synthetic rope assemblies and is applicable to electric traction overhead contact lines for railways, light railways, tramways, trolleybuses and other systems. This standard establishes requirements and characteristics of the rope, test methods and checking procedures to be used with the insulating synthetic ropes, together with the ordering and delivery requirements.
IEC 62724:2013 is classified under the following ICS (International Classification for Standards) categories: 19.040 - Environmental testing; 45.060.01 - Railway rolling stock in general. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 62724:2013 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC 62724 ®
Edition 1.0 2013-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Railway applications – Fixed installations – Electric traction – Insulating
synthetic rope assemblies for support of overhead contact lines
Applications ferroviaires – Installations fixes – Traction électrique – Montages
mettant en œuvre des câbles synthétiques isolants pour le support des lignes
aériennes de contact
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni
utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les
microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.
IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
Useful links:
IEC publications search - www.iec.ch/searchpub Electropedia - www.electropedia.org
The advanced search enables you to find IEC publications The world's leading online dictionary of electronic and
by a variety of criteria (reference number, text, technical electrical terms containing more than 30 000 terms and
committee,…). definitions in English and French, with equivalent terms in
It also gives information on projects, replaced and additional languages. Also known as the International
withdrawn publications. Electrotechnical Vocabulary (IEV) on-line.
IEC Just Published - webstore.iec.ch/justpublished Customer Service Centre - webstore.iec.ch/csc
Stay up to date on all new IEC publications. Just Published If you wish to give us your feedback on this publication
details all new publications released. Available on-line and or need further assistance, please contact the
also once a month by email. Customer Service Centre: csc@iec.ch.
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
Liens utiles:
Recherche de publications CEI - www.iec.ch/searchpub Electropedia - www.electropedia.org
La recherche avancée vous permet de trouver des Le premier dictionnaire en ligne au monde de termes
publications CEI en utilisant différents critères (numéro de électroniques et électriques. Il contient plus de 30 000
référence, texte, comité d’études,…). termes et définitions en anglais et en français, ainsi que
Elle donne aussi des informations sur les projets et les les termes équivalents dans les langues additionnelles.
publications remplacées ou retirées. Egalement appelé Vocabulaire Electrotechnique
International (VEI) en ligne.
Just Published CEI - webstore.iec.ch/justpublished
Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications de la CEI.
Just Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur
Disponible en ligne et aussi une fois par mois par email. cette publication ou si vous avez des questions
contactez-nous: csc@iec.ch.
IEC 62724 ®
Edition 1.0 2013-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Railway applications – Fixed installations – Electric traction – Insulating
synthetic rope assemblies for support of overhead contact lines
Applications ferroviaires – Installations fixes – Traction électrique – Montages
mettant en œuvre des câbles synthétiques isolants pour le support des lignes
aériennes de contact
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX U
ICS 45.060 ISBN 978-2-8322-1287-5
– 2 – 62724 © IEC:2013
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms, definitions and abbreviations . 8
3.1 Terms and definitions . 8
3.2 Abbreviations . 9
4 Characteristics and requirements for the rope . 9
4.1 General . 9
4.1.1 Common characteristics . 9
4.1.2 Specific characteristics of core materials . 9
4.1.3 Specific requirements of sheath materials . 9
4.2 Client requirements . 10
4.3 Electrical requirements . 10
4.3.1 Voltages . 10
4.3.2 Creepage distances . 10
4.4 Mechanical requirements . 11
4.4.1 Minimum breaking load . 11
4.4.2 Permissible tensile loading . 11
4.4.3 Permissible tensile loading on a mid-span connector (non-
vertical load) . 11
4.4.4 Time dependant properties . 11
4.4.5 Other mechanical properties . 11
4.5 Environmental conditions . 11
4.5.1 General . 11
4.5.2 Pollution . 12
4.5.3 Corrosion . 12
4.5.4 UV resistance . 12
4.6 Fire hazard . 12
4.7 Tracking and erosion . 12
5 Design, manufacture and workmanship . 12
6 Testing . 13
6.1 General . 13
6.2 Design tests for rope types . 13
6.2.1 General . 13
6.2.2 Test specimens and preliminary tests . 13
6.2.3 Dry power frequency withstand voltage test . 14
6.2.4 Test of housing: tracking and erosion . 15
6.2.5 Flammability test . 15
6.3 Type tests . 15
6.3.1 General . 15
6.3.2 Dry lightning impulse withstand voltage test . 16
6.3.3 Wet power frequency test . 16
6.3.4 Breaking load . 16
6.4 Sampling test . 16
6.4.1 General . 16
62724 © IEC:2013 – 3 –
6.4.2 Sampling test for insulating synthetic rope . 16
6.4.3 Sampling test for the termination . 17
6.4.4 Sampling tests for made up components (e.g. delta
suspension, etc.) . 17
6.4.5 Re-test procedure for sampling tests . 18
6.5 Manufacturer routine tests . 18
7 Component identification . 18
7.1 Rope identification . 18
7.2 Termination identification . 19
8 Verification of compliance . 19
8.1 Certification of compliance and test results . 19
8.2 Inspection and testing . 19
8.3 Test certificates . 20
8.4 Drawings . 20
9 Installation instructions . 20
10 Maintenance instructions . 20
11 Delivery and packaging . 21
11.1 Rope . 21
11.2 Terminations . 21
11.3 Insulators . 21
Annex A (normative) Breaking load and endurance test load . 23
Annex B (normative) Testing . 24
Annex C (informative) Intermediate clamp. 25
Annex D (informative) Quality assurance . 26
Bibliography . 27
Figure 1 – The maximum and minimum loads for endurance test . 14
Table 1 – Additional creepage distance per extra kV of the nominal voltage. 11
Table 2 – Number of drums to submit for testing . 17
Table 3 – Number of terminations examined complying with the lot size . 17
Table A.1 – Dimensions and the minimum breaking loads and endurance test loads of
the insulating synthetic ropes . 23
Table B.1 – Element to submit to tests . 24
– 4 – 62724 © IEC:2013
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RAILWAY APPLICATIONS –
FIXED INSTALLATIONS –
ELECTRIC TRACTION –
INSULATING SYNTHETIC ROPE ASSEMBLIES
FOR SUPPORT OF OVERHEAD CONTACT LINES
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62724 has been prepared by IEC technical committee 9: Electrical
equipment and systems for railways.
This standard is derived from EN 50345.
The text of this standard is based on the following documents:
FDIS Report on voting
9/1853/FDIS 9/1870/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
62724 © IEC:2013 – 5 –
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 6 – 62724 © IEC:2013
INTRODUCTION
This International standard has been prepared to provide general guidance and to define
special requirements for the design and testing of insulating synthetic ropes, their sheaths
and their terminations for use in electric traction overhead contact lines.
Special preferences will include such requirements as to comply with local procurement
policies, working practices, compatibility with existing systems, to combat environmental
pollution and to provide a supporting assembly with insulation which will give reliable service
over its target life span.
These insulating synthetic ropes offer an alternative to the use of metallic cables associated
with conventional insulators.
62724 © IEC:2013 – 7 –
RAILWAY APPLICATIONS –
FIXED INSTALLATIONS –
ELECTRIC TRACTION –
INSULATING SYNTHETIC ROPE ASSEMBLIES
FOR SUPPORT OF OVERHEAD CONTACT LINES
1 Scope
This International standard applies to the insulating synthetic ropes used in overhead contact
lines.
This International standard specifies the requirements of insulating synthetic rope assemblies
and is applicable to electric traction overhead contact lines for railways, light railways,
tramways, trolleybuses and other systems.
These insulating synthetic ropes are utilised to provide mechanical support and electrical
insulation for overhead contact lines.
They are generally used in the following application fields:
– delta suspension of contact wires;
– catenary cable;
– mid-point anchors;
– tie;
– dropper;
– headspan;
– noise and vibration damper;
– bridle- and pulley suspensions;
– cantilevers made of glass reinforced polymer (GRP).
This standard establishes requirements and characteristics of the rope, test methods and
checking procedures to be used with the insulating synthetic ropes, together with the ordering
and delivery requirements.
The synthetic ropes only for mechanical applications are not part of this international standard.
Anyway the mechanical requirements and tests stated in this standard can be used for this
kind of ropes.
The object of this standard is to stipulate provisions for the design and to allow provision of
the service indicated by the supplier to the purchaser or informed buyer.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
– 8 – 62724 © IEC:2013
IEC 60060-1:2010, High-voltage test techniques – Part 1: General definitions and test
requirements
IEC 60695-11-10:2013, Fire hazard testing – Part 11-10: Test flames – 50 W horizontal and
vertical flame test methods
IEC 60913:2013, Railway applications – Fixed installations – Electric traction overhead
contact lines
IEC 61109:2008, Insulators for overhead lines – Composite suspension and tension insulators
for a.c. systems with a nominal voltage greater than 1 000 V – Definitions, test methods and
acceptance criteria
IEC 62217:2012, Polymeric HV insulators for indoor and outdoor use - General definitions,
test methods and acceptance criteria
IEC 62497-1:2010, Railway applications – Insulation coordination – Part 1: Basic
requirements – Clearances and creepage distances for all electrical and electronic equipment
IEC 62498-2, Railway applications – Environmental conditions for equipment – Part 2: Fixed
electrical installations
ISO 4892-2:2006, Plastics – Methods of exposure to laboratory light sources – Part 2: Xenon-
arc lamps
3 Terms, definitions and abbreviations
3.1 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1.1
creepage distance
shortest distance along the surface of a solid insulating material between two conductive
parts
[SOURCE: IEC 60050-151:2001, 151-15-50]
3.1.2
gauge length
distance between the centre lines of the termination anchoring pins or bolts
3.1.3
insulator
assembly of an insulating synthetic rope and its associated terminations
3.1.4
insulating synthetic rope
rope which consists of at least one organic based material with or without sheath
3.1.4.1
core of the rope
consists of synthetic fibres and is the load carrying component of the rope
62724 © IEC:2013 – 9 –
3.1.4.2
sheath of the rope
envelope to protect the fibres and made of synthetic material, usually of a continuous
polymeric material with appropriate insulating qualities
3.1.5
termination
means to connect the ends of an insulating synthetic rope between two points
3.2 Abbreviations
a.c. alternating current
d.c. direct current
GRP glass reinforced polymer
UV ultraviolet
4 Characteristics and requirements for the rope
4.1 General
4.1.1 Common characteristics
Two major fibre types are used actually to provide the load carrying core. These are polyester
and polyaramid. Other fibre types having similar characteristics may also be used.
The fibre type is important in determining mechanical properties.
The sheath polymer type is important in determining durability, environmental performance
and some electrical and mechanical properties.
4.1.2 Specific characteristics of core materials
Insulating synthetic ropes with polyaramid or similar core fibres have a smaller diameter,
greater tensile fatigue resistance and smaller elongation than those of polyester or similar
core fibres for a given load carrying capacity and axial stiffness.
Insulating synthetic ropes with polyester or similar core fibres have a higher impact resistance
than those of polyaramid or similar core fibres, for example: from detached trolleybus poles.
Insulating synthetic ropes can operate within the following operational environmental
temperatures:
– between –40 °C and +55 °C for polyester or similar;
– between –40 °C and +80 °C for polyaramid or similar.
4.1.3 Specific requirements of sheath materials
The sheath may be composed of different materials. The type of material shall be chosen to
withstand local conditions as:
– UV exposure (e.g. polyethylene);
– general environmental conditions (e.g. polyethylene);
– abrasion effects (e.g. polyester / elastomer);
– flex effects (e.g. polyester / elastomer).
– 10 – 62724 © IEC:2013
When the rope is used in confined spaces (e.g. tunnels, stations, etc.) the sheath material
shall have further properties as:
– electrical tracking resistance (e.g. crosslinked polyethylene);
– antiflammability (e.g. crosslinked polyethylene);
– self-extinguishing (e.g. crosslinked polyethylene).
4.2 Client requirements
The client shall provide a comprehensive and specific description of the overhead contact line
service parameters and functioning requirements which may affect the design of the insulated
synthetic rope.
This shall include, as appropriate, but not be limited to the following:
– electrical system service parameters;
– spatial and dimensional parameters;
– angular movement deflection limitations;
– maximum working loads required;
– environmental conditions;
– end fittings connection (terminations) requirements;
– any additional requirement for special tests;
– any special delivery or packaging requirements;
– identification of inspection and tests to be witnessed by the purchaser;
– service life of the insulator.
4.3 Electrical requirements
4.3.1 Voltages
Values of voltages are shown in Table A.2 of IEC 62497-1:2010. The rated insulation voltage
and the test voltage levels are based on statistical and risk consideration, which may affect
the insulator during its service life.
4.3.2 Creepage distances
Creepage distances shall be determined to withstand the highest permanent voltage of the
system. Consideration shall also be given to the type of insulating synthetic rope and its
behaviour in polluted conditions related to the whole life of the equipment.
The minimum creepage distance, for nominal voltages equal to or below 1,5 kV d.c. or 1 kV
a.c. shall be 1 m. This creepage distance can be reduced for special rope types up to 0,5 m if
tests and long time experiences are available.
NOTE This distance is based on practical experience.
For nominal voltages exceeding 1,5 kV d.c. or 1 kV a.c., an additional creepage distance per
extra kV of the nominal voltage shall be calculated from Table 1 and added to the minimum
creepage distance.
EXAMPLE A 25 kV a.c. system with 45° inclination with no waterproof termination and for extreme unfavourable
conditions requires a total creepage distance of 3 040 mm.
62724 © IEC:2013 – 11 –
Table 1 – Additional creepage distance per extra kV of the nominal voltage
Waterproof termination No waterproof termination
Horizontal 45° inclination Horizontal 45° inclination
Additional creepage distances
and vertical and vertical
mm/kV mm/kV mm/kV mm/kV
Normal operating conditions 30 35 45 55
Unfavourable operating conditions 40 45 60 70
Extreme unfavourable operating conditions 50 55 75 85
NOTE These values are based on practical experience.
The creepage distance values for nominal voltage up to 1,5 kV d.c. are valid for double
insulation.
4.4 Mechanical requirements
4.4.1 Minimum breaking load
The dimensions and the minimum breaking loads of the insulating synthetic ropes may be
taken from Table A.1 of Annex A. Other types may be agreed with the manufacturer.
4.4.2 Permissible tensile loading
The permissible tensile load shall be in accordance with 5.7 and Clause 6 of IEC 60913:2013.
4.4.3 Permissible tensile loading on a mid-span connector (non-vertical load)
The maximum working load which can be applied to a mid-span anchor shall not exceed 25 %
of the breaking load of the rope and its associated termination.
The breaking load of the mid-span connector and rope combination shall be determined
experimentally. Account shall be taken of anticipated operating conditions and of the actual
direction of applied loads.
4.4.4 Time dependant properties
The supplier shall provide information on the following insulating synthetic rope properties:
– fatigue behaviour (cycling loading);
– creep behaviour (under constant loading);
– stress relaxation behaviour (between two fixed anchors).
4.4.5 Other mechanical properties
The supplier shall provide information on the load extension characteristics of the insulating
synthetic ropes.
4.5 Environmental conditions
4.5.1 General
Insulating synthetic ropes shall operate within operational environmental conditions given in
IEC 62498-2.
– 12 – 62724 © IEC:2013
Normal operating conditions exist when there is low industrial pollution, a low population
density and no thermal engines.
Unfavourable operating conditions exist when there is high industrial pollution and industrial
gases, a high population density, mixed railway operation, road traffic and frequent fog.
Extremely unfavourable operating conditions exist close to large power plants, chemical
industry, smelting works, with frequent fog or near the ocean.
4.5.2 Pollution
In addition to the electrical and mechanical performance requirements, the design shall
address the suitability of the sheath of the insulating synthetic rope surface to cater for levels
of pollution which are likely to be encountered during its service life (for example: the ability of
the sheath to shed water or pollutants from the surface and the ability of the system to
withstand wetting by salt water in coastal applications).
4.5.3 Corrosion
The terminations and mid-span connectors shall be suitably protected from corrosion and
compatible with interface connections. When appropriate, attention shall be given to
protection against moisture ingress, chemical activity or the influence of temperature
variations or unidirectional current flow.
4.5.4 UV resistance
The composition of the sheath of the insulating synthetic ropes shall be suitably chosen to
take into account the effects of local UV radiation levels which are likely to be encountered
during its service life.
Aging test of the sheath material ISO 4892-2:2006 can be used. When the materials of sheath
are the same, it is not necessary to do aging test for different diameters again.
4.6 Fire hazard
Fire hazard risks associated with each application should be assessed and appropriate core
fibres and sheath polymer types selected.
Special attention shall be paid to the possibility of gas emissions for applications in confined
spaces, e.g. tunnels, stations, etc.
4.7 Tracking and erosion
In addition to the electrical and mechanical performance requirements, the design shall
address the suitability of the sheath of the insulating synthetic rope surface to cater for
damage from tracking and erosion under conditions which are likely to be encountered during
its service life.
5 Design, manufacture and workmanship
The insulating synthetic ropes shall be designed and manufactured in accordance with best
practice, taking cognisance of the system in which they will operate and with the need to
design end terminations to match specific rope sizes and types. All material shall be of the
quality and of the type most suitable for working under conditions specified for the full service
life of the insulating synthetic ropes.
62724 © IEC:2013 – 13 –
The supplier shall provide a safety case for insulating synthetic ropes with novel or innovative
features not previously used within the railway environment. The safety case shall quantify
any additional risks and indicate how these risks are controlled.
Whenever a waterproof termination is specified, the manufacturer of the termination shall
produce an extra assembly guide.
6 Testing
6.1 General
The necessary tests and the elements to which these tests are to be applied are given in
Annex B.
6.2 Design tests for rope types
6.2.1 General
The design tests are intended to verify the suitability of the design materials and the method
of manufacture. When an insulator is submitted to the design tests, the results shall be
considered valid for the whole class of the insulator which are represented by the one test
and have the same named characteristics.
The design tests shall be performed on three specimens.
The following tests shall be performed for each class of test:
– breaking test;
– endurance test;
– electrical test (dry power frequency withstand voltage test and test of tracking and erosion
for housing);
– flammability test.
NOTE UV resistance of the sheath material can be proved by certificate according to ISO 4892:2:2006.
6.2.2 Test specimens and preliminary tests
6.2.2.1 Product identification and labels
Each synthetic rope shall be marked with the name or trademark of the manufacturer, the
year of manufacture and the diameter of the rope. These identifications shall be printed every
metre legibly and indelibly. For a correct identification, see Clause 7.
6.2.2.2 Visual check and dimensions (drawing)
The dimensions of the tested synthetic ropes shall be checked in accordance with the relevant
drawings, taking note of any special tolerances. In addition, the rope sheath shall be checked
visually in order to detect any surface defects such as cracks, grooves, inclusions, etc.
6.2.2.3 Breaking test
For this test the sample lengths (termination excluded) shall be at least equal to 1,0 m.
The test samples shall be subjected to a tensile load by a testing machine. The tensile load
shall be increased from zero, smoothly with an extension rate up to 20 % of the gauge length
per minute, up to the mechanical failure of the synthetic rope.
– 14 – 62724 © IEC:2013
The rope passes the test if the average value of the three samples exceeds the minimum
specified breaking load and, for each tested sample, the recorded breaking load value shall
exceed 95 % of the minimum specified breaking load.
6.2.2.4 Endurance test
A cyclic load shall be applied for this test. The sample lengths (termination excluded) shall be
at least equal to 0,9 m.
The mean load shall be equal to 30 % of the minimum specified breaking load for rope. The
maximum and minimum loads shall be applied to ± 15 % of the mean load as shown in
Figure 1 and Table A.1 of Annex A. Other types may be agreed with the manufacturer.
50 %
40 %
+15 % of mean load
30 %
–15 % of mean load
20 %
10 %
0 %
0 0,5 1
Time (s)
IEC 2946/13
Figure 1 – The maximum and minimum loads for endurance test
The cyclic loading frequency shall be at maximum of 10 cycles per second.
The rope passes the test if for each of the three samples the minimum number of load cycles
6 6
to failure shall be 3 × 10 cycles for polyaramid or similar fibres and 10 × 10 cycles for
polyester or similar fibres exceed.
6.2.3 Dry power frequency withstand voltage test
The sample lengths shall be at least 1,0 m. If special rope types are used for creepage
distances ≥0,5 m and <1 m, the sample lengths shall be 0,5 m.
This test is performed on insulators and conducted in two parts to allow the comparison
between a dry sample and one which has been immersed in water.
The test shall be performed in accordance with 9.2.4 of IEC 62217:2012.
Minimum specified breaking load
62724 © IEC:2013 – 15 –
The samples shall be tested before the immersion in horizontal or 45° inclination position,
after immersion the samples shall be tested in horizontal and 45° position.
The same tests shall be repeated on samples after their immersion in water according to
Table 2 of IEC 60060-1:2010, for a minimum period of 100 h. The test samples shall be
dipped completely including the end terminations.
The test is fulfilled if the power frequency withstand voltages of Table A.2 of IEC 62497-
1:2010 are achieved for all samples before and after the immersion.
6.2.4 Test of housing: tracking and erosion
This test shall be performed only when insulators are to be used on an a.c. system with a
nominal system voltage greater than 1 000 V.
Two samples are required for this test. The creepage distance shall be equal to 1,0 m. This
creepage distance can be reduced up to 0,5 m if special rope types are used.
This test shall be performed in accordance with 9.3.3 of IEC 62217:2012.
The test is a time-limited continuous test under salt fog at constant power frequency voltage
of 18 kV (corresponding to a specific creepage distance of 55 mm/kV) given in Table 1. Initial
NaCl content of the water shall be equal to (8 ± 0,4) kg/m .
The test shall be regarded as passed if on both tested ropes:
– no tracking occurs;
– no erosion cracks are present;
– no shed (if any), housing or interface is punctured.
6.2.5 Flammability test
Flammability tests may be requested by the purchaser. The flammability test for the finished
insulator shall be according to IEC 60695-11-10:2013. The test is passed if the test specimen
satisfies the requirements of category HB 40. The acceptance category shall be recorded.
6.3 Type tests
6.3.1 General
An insulator type is defined for type testing purposes by the core material, the core diameter,
the sheath material, the creepage distance and the method of attachment and type of the
metal terminations.
The type tests shall be performed only once on insulators satisfying the above criteria for
each type.
The type tests shall be repeated only when any of the above characteristics are changed.
For electrical tests, the creepage distance shall be equal or less than the distance determined
from Table 1.
The tests as described in 6.3.2 to 6.3.4 shall be undertaken.
– 16 – 62724 © IEC:2013
6.3.2 Dry lightning impulse withstand voltage test
The tests shall be performed in accordance with 11.1 of IEC 61109:2008. For the synthetic
ropes, the test voltage values are given in Table A.2 of IEC 62497-1:2010.
6.3.3 Wet power frequency test
The tests shall be performed in accordance with 11.1 of IEC 61109:2008. For the synthetic
ropes, the test voltage values are given in Table A.2 of IEC 62497-1:2010.
Deviations from the requirements are permitted when the soundness of such deviations can
be substantiated.
6.3.4 Breaking load
The test samples shall be subjected to a tensile load by a testing machine. The tensile load
shall be increased from zero, smoothly with an extension rate up to 20 % of the gauge length
per minute, up to the mechanical failure of the synthetic rope.
The rope passes the test if the average value of the three samples exceeds the minimum
specified breaking load. Moreover, for each tested sample, the recorded breaking load value
shall exceed 95 % of the minimum specified breaking load.
For mechanical tests, the sample lengths (termination excluded) shall be at least equal to
1,0 m.
6.4 Sampling test
6.4.1 General
The sampling test is for the purpose of verifying other characteristics of insulating synthetic
ropes, including those which depend on the quality of manufacture and on the materials used.
It is made on insulating synthetic ropes taken at random from lots offered for acceptance.
6.4.2 Sampling test for insulating synthetic rope
The sampling tests shall consist of:
– product identification and labels;
– visual examination of the sheath;
– verification of dimensions;
– winding test.
Number of drums to submit for testing shall be according to Table 2.
62724 © IEC:2013 – 17 –
Table 2 – Number of drums to submit for testing
Number of drums submitted for testing Sample size
Lot size
N
N ≤ 10 1
10 < N ≤ 25
25 < N ≤ 50
50 < N ≤ 80
80 < N ≤ 120 9
120 < N ≤ 170
170 < N ≤ 225
NOTE If the number of drums exceeds 225, a sample size shall be agreed between
supplier and client.
The winding test shall be carried out by winding five turns of rope on to a cylinder, the
diameter of which shall be taken equal to thirty times the external diameter of the rope.
The insulating synthetic rope shall not present, after testing, any significant defects (stretch,
tears, ovality, severe changes in section) which can affect its mechanical or electrical
characteristics and/or can affect the quality of the fitting of the rope into the termination.
6.4.3 Sampling test for the termination
The sampling test shall consist of:
– verification of identification marks;
– visual examination of the termination;
– verification of dimensions;
– verification that rope and termination are designed to be used together;
– verification of the specified breaking load.
The number of terminations examined shall comply with the lot size according to Table 3.
Table 3 – Number of terminations examined complying with the lot size
Lot size Sample size
N
Subject to agreement
N ≤ 300
300 < N ≤ 2 000
2 000 < N ≤ 5 000
5 000 < N ≤ 10 000 18
6.4.4 Sampling tests for made up components (e.g. delta suspension, etc.)
The sampling test shall consist of:
– visual examination of the component;
– 18 – 62724 © IEC:2013
– verification of dimensions;
– verification that rope and termination are designed to be used together;
– verification of the specified breaking load.
The number of components examined shall comply with the lot size according to Table 3.
6.4.5 Re-test procedure for sampling tests
When specified in the acceptance criteria, the following re-test procedure applies for sample
tests.
If only one synthetic rope or termination fails to comply with the sampling tests, a new sample
equal to twice the quantity originally submitted to that test shall be subjected to re-testing.
The re-testing shall comprise the test in which failure occurred, preceded by those tests which
may be considered as having influenced the results of the original test.
If two or more ropes or terminations fail to comply with any of the sampling tests, or if any
failure occurs during the re-testing, the complete lot shall be considered as not complying with
the requirements stated in 6.4 and shall be withdrawn by the manufacturer.
Provided the cause of the failure can be clearly identified, the manufacturer may sort the lot to
eliminate all the insulators with this defect. In the case of a lot that has been divided into
smaller lots and if one of the smaller lots does not comply, the investigation may be extended
to the other lots. The sorted lot(s) or part thereof may then be re-submitted for testing. The
number then selected shall be three times the first quantity chosen for the tests. The re-
testing shall comprise the test in which failure occurred preceded by those tests which may be
considered as having influenced the results of the original te
...