Amendment 1 - Household and similar electrical appliances - Safety - Part 1: General requirements

Applies to analogue pneumatic signals used in process control systems to transmit information between the elements of systems and gives definitions, units and the recommended value of the range of the analogue pneumatic signal.

Amendement 1 - Appareils électrodomestiques et analogues - Sécurité - Partie 1: Exigences générales

S'applique aux signaux analogiques pneumatiques utilisés dans des systèmes de conduite de processus pour la transmission de données entre les éléments de systèmes et donne la terminologie, les unités et la valeur recommandée de l'étendue de signal analogique pneumatique.

General Information

Status
Published
Publication Date
09-Dec-2013
Current Stage
DELPUB - Deleted Publication
Completion Date
02-Sep-2020
Ref Project

Buy Standard

Standard
IEC 60335-1:2010/AMD1:2013 - Amendment 1 - Household and similar electrical appliances - Safety - Part 1: General requirements
English and French language
42 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

IEC 60335-1
Edition 5.0 2013-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 1
AMENDEMENT 1
Household and similar electrical appliances – Safety –
Part 1: General requirements
Appareils électrodomestiques et analogues – Sécurité –
Partie 1: Exigences générales
IEC 60335-1:2010/A1:2013
---------------------- Page: 1 ----------------------
THIS PUBLICATION IS COPYRIGHT PROTECTED
Copyright © 2013 IEC, Geneva, Switzerland

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form

or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from

either IEC or IEC's member National Committee in the country of the requester.

If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,

please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni

utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les

microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.

Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette

publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC

The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes

International Standards for all electrical, electronic and related technologies.
About IEC publications

The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the

latest edition, a corrigenda or an amendment might have been published.
Useful links:

IEC publications search - www.iec.ch/searchpub Electropedia - www.electropedia.org

The advanced search enables you to find IEC publications The world's leading online dictionary of electronic and

by a variety of criteria (reference number, text, technical electrical terms containing more than 30 000 terms and

committee,…). definitions in English and French, with equivalent terms in

It also gives information on projects, replaced and additional languages. Also known as the International

withdrawn publications. Electrotechnical Vocabulary (IEV) on-line.

IEC Just Published - webstore.iec.ch/justpublished Customer Service Centre - webstore.iec.ch/csc

Stay up to date on all new IEC publications. Just Published If you wish to give us your feedback on this publication

details all new publications released. Available on-line and or need further assistance, please contact the

also once a month by email. Customer Service Centre: csc@iec.ch.
A propos de la CEI

La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des

Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI

Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez

l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
Liens utiles:

Recherche de publications CEI - www.iec.ch/searchpub Electropedia - www.electropedia.org

La recherche avancée vous permet de trouver des Le premier dictionnaire en ligne au monde de termes

publications CEI en utilisant différents critères (numéro de électroniques et électriques. Il contient plus de 30 000

référence, texte, comité d’études,…). termes et définitions en anglais et en français, ainsi que

Elle donne aussi des informations sur les projets et les les termes équivalents dans les langues additionnelles.

publications remplacées ou retirées. Egalement appelé Vocabulaire Electrotechnique

International (VEI) en ligne.
Just Published CEI - webstore.iec.ch/justpublished
Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications de la CEI.

Just Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur

Disponible en ligne et aussi une fois par mois par email. cette publication ou si vous avez des questions

contactez-nous: csc@iec.ch.
---------------------- Page: 2 ----------------------
IEC 60335-1
Edition 5.0 2013-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 1
AMENDEMENT 1
Household and similar electrical appliances – Safety –
Part 1: General requirements
Appareils électrodomestiques et analogues – Sécurité –
Partie 1: Exigences générales
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX S
ICS 13.120, 97.030 ISBN 978-2-8322-1203-5

Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 3 ----------------------
– 2 – 60335-1 Amend. 1 © IEC:2013
FOREWORD

This amendment has been prepared by IEC technical committee 61: Safety of household and

similar electrical appliances.
The text of this amendment is based on the following documents:
FDIS Report on voting
61/4639/FDIS 61/4675/RVD

Full information on the voting for the approval of this amendment can be found in the report

on voting indicated in the above table.

The committee has decided that the contents of this amendment and the base publication will

remain unchanged until the stability date indicated on the IEC web site under

"http://webstore.iec.ch" in the data related to the specific publication. At this date, the

publication will be
 reconfirmed,
 withdrawn,
 replaced by a revised edition, or
 amended.
The contents of the corrigendum of January 2014 have been included in this copy.

NOTE The attention of National Committees is drawn to the fact that equipment manufacturers and testing

organizations may need a transitional period following publication of a new, amended or revised IEC publication in

which to make products in accordance with the new requirements and to equip themselves for conducting new or

revised tests.

It is the recommendation of the committee that the content of this publication be adopted for implementation

nationally not earlier than 12 months or later than 36 months from the date of publication.

_____________
1 Scope
Add the following to Note 1:

Dual supply appliances, either mains-supplied or battery-operated, are regarded as battery-operated appliances

when operated in the battery mode.
---------------------- Page: 4 ----------------------
60335-1 Amend. 1 © IEC:2013 – 3 –
2 Normative references
Replace the reference to IEC 60252-1 by the following:

IEC 60252-1:2010, AC motor capacitors – Part 1: General – Performance, testing and rating –

Safety requirements – Guidance for installation and operation
Add the following references:
IEC 60034-1, Rotating electrical machines – Part 1: Rating and performance

IEC 60730-2-9:2008 , Automatic electrical controls for household and similar use – Part 2-9:

Particular requirements for temperature sensing controls

IEC 61558-2-16, Safety of transformers, reactors, power supply units and similar products for

supply voltages up to 1 100 V – Part 2-16: Particular requirements and tests for switch mode

power supply units and transformers for switch mode power supply units

IEC 62477-1, Safety requirements for power electronic converter systems and equipment –

Part 1: General
3 Terms and definitions
3.2.2 interconnection cord
Replace the existing definition and note by the following:

external flexible cord between two parts of an appliance, provided as part of a complete

appliance for purposes other than connection to the supply mains

NOTE In battery-operated appliances, if the battery is placed in a separate box, the flexible lead or flexible cord

connecting the box with the appliance is considered to be an interconnection cord.

3.3.10 class II appliance
Delete Note 3.
Add the following new definitions:
3.3.16
battery-operated appliance

appliance deriving its energy from batteries enabling the appliance to perform its intended

function without a mains connection
3.6.7
battery box

separate compartment for containing the batteries that is detachable from the appliance

5 General conditions for the tests
5.17 Replace the existing text by the following:

Appliances powered by rechargeable batteries that are recharged in the appliance are tested

in accordance with Annex B.
—————————

There exists a consolidated edition 3.1 (2011) that includes edition 3:2008 and its Amendment 1:2011.

---------------------- Page: 5 ----------------------
– 4 – 60335-1 Amend. 1 © IEC:2013

Battery-operated appliances powered by batteries that are non-rechargeable or not

recharged in the appliance are tested in accordance with Annex S.
7 Marking and instructions
7.1 Add the following new paragraph after Note 4:

Class II appliances and class III appliances incorporating a functional earth shall be marked

with the symbol IEC 60417-5018 (2011-07).
7.3 In Note 3, replace the text of the example by the following.

EXAMPLE: 230 V /400 V 3N : The appliance is only suitable for the voltage values indicated, 230 V being

for single-phase, a.c. operation and 400 V 3N for three-phase, a.c. with neutral operation (an appliance with

terminals for both supplies).
7.4 Replace the requirement by the following:

If the appliance can be adjusted for different rated voltages or rated frequencies, the

voltage or the frequency to which the appliance is adjusted shall be clearly discernible. If

frequent changes in voltage setting or frequency setting are not required, this requirement is

considered to be met if the rated voltage or rated frequency to which the appliance is to be

adjusted can be determined from a wiring diagram fixed to the appliance.

7.6 Replace [symbol ISO 7000-0434 (2004-01)] by [symbol ISO 7000-0434A (2004-01)].

7.8 Add the following to the first paragraph of the requirement:

– functional earthing terminals shall be indicated by symbol IEC 60417-5018 (2011-07).

7.12 Delete “for use” in the first paragraph and in the Note.
Add the following after the existing last paragraph of the requirement:

For appliances intended for use at altitudes exceeding 2 000 m, the maximum altitude of use

shall be stated.

The instructions for appliances incorporating a functional earth shall state the substance of

the following:
This appliance incorporates an earth connection for functional purposes only.
7.12.1 Add the following text:

For appliances marked with different rated voltages or different rated frequencies

(separated by a /), instructions shall be included to indicate to the user or installer what action

must be taken to adjust the appliance for operation at the required rated voltage or rated

frequency.
7.15 Add the following:

The symbol IEC 60417-5018 (2011-07) shall be placed next to the symbol IEC 60417-5172

(2003-02) or the symbol IEC 60417-5180 (2003-02) as appropriate.
8 Protection against access to live parts
8.1.1 Delete the Note.
---------------------- Page: 6 ----------------------
60335-1 Amend. 1 © IEC:2013 – 5 –
10 Power input and current

10.1 Replace the penultimate paragraph of the test specification by the following:

If the power input varies throughout the operating cycle and the maximum value of the power

input exceeds, by a factor greater than two, the arithmetic mean value of the power input

occurring during a representative period, then the power input is the maximum value that is

exceeded for more than 10 % of the representative period. Otherwise the power input is taken

as the arithmetic mean value.

10.2 Replace the penultimate paragraph of the test specification by the following:

If the current varies throughout the operating cycle and the maximum value of the current

exceeds, by a factor greater than two, the arithmetic mean value of the current occurring

during a representative period, then the current is the maximum value that is exceeded for

more than 10 % of the representative period. Otherwise the current is taken as the arithmetic

mean value.
11 Heating
11.8 Delete the second sentence of the first paragraph.
Table 3 – Maximum normal temperature rises
After the entry for pins of appliance inlets, add the following new entry:
Pins of appliances for insertion into socket-outlets 45

Replace the second to last, third to last and fourth to last entries in Table 3 by the following:

External enclosure of motor-operated appliances except handles held in normal use:

– of bare metal 48
– of coated metal 59
– of glass and ceramic 65
– of plastic having a thickness exceeding 0,4 mm 74

Surfaces of handles, knobs, grips and similar parts which are continuously held in normal use

(e.g. soldering irons):
– of bare metal 30
– of coated metal 34
– of porcelain or vitreous material 40
– of rubber or of plastic having a thickness exceeding 0,4 mm 50
– of wood 50

Surfaces of handles, knobs, grips and similar parts which are held for short periods only in normal

use (e.g. switches):
– of bare metal 35
– of coated metal 39
– of porcelain or vitreous material 45
– of rubber or of plastic having a thickness exceeding 0,4 mm 60
– of wood 65
---------------------- Page: 7 ----------------------
– 6 – 60335-1 Amend. 1 © IEC:2013
Add the following footnotes to Table 3:

The temperature rise limits of controls actuated by contact or proximity of a finger, with no movement of the

contact surface also includes all surfaces within 5 mm of such controls, regardless of their shape.

The temperature rise limit of plastic also applies for plastic material having a metal finish of thickness less than

0,1 mm.

When the thickness of the plastic coating does not exceed 0,4 mm, the temperature rise limits of the coated

metal or of glass and ceramic material apply.

Metal is considered coated when a coating having a minimum thickness of 90 µm made by enamel, powder or

non-substantially plastic coating is used.
13 Leakage current and electric strength at operating temperature

13.2 In the first paragraph, after “class II appliances” add “, class II constructions” and

replace the second sentence by the following:

For class 0I appliances and class I appliances, C may be replaced by a low impedance

ammeter responding to the rated frequency of the appliance.
Replace the second paragraph by the following:
The leakage current is measured between any pole of the supply and

– accessible metal parts intended to be connected to protective earth, for class l

appliances and class 0l appliances;

– metal foil having an area not exceeding 20 cm × 10 cm which is in contact with accessible

surfaces of insulating material and metal parts not intended to be connected to protective

earth, for class 0 appliances, class II appliances, class ll constructions and class III

appliances.
Replace the fourth paragraph by the following:

For single-phase appliances, the measuring circuit is shown in the following figures:

– if they are class II appliances or parts of class II construction, Figure 1;

– if they are neither class II appliances nor parts of class II construction, Figure 2.

Replace the sixth paragraph by the following:

For three-phase with neutral (3N~) connected appliances, the measuring circuit is shown in

the following figures:
– if they are class II appliances or parts of class II construction, Figure 3;

– if they are neither class II appliances nor parts of class II construction, Figure 4.

Delete “For three-phase appliances,” from the first sentence of the seventh paragraph.

Replace the third sentence of the seventh paragraph by the following:

For three-phase without neutral (3~) connected appliances, the measuring circuit in Figure 3

or Figure 4 shall be used as applicable, but the neutral is not connected to the appliance.

In the existing eighth paragraph, replace the first dashed item by the following:

– for class II appliances and for parts of class II construction 0,35 mA peak
---------------------- Page: 8 ----------------------
60335-1 Amend. 1 © IEC:2013 – 7 –
15 Moisture resistance
15.2
Replace the first paragraph of the test specification by the following:

Compliance is checked by the following test using a spillage solution comprising water

containing approximately 1 % NaCl and 0,6 % rinsing agent.
Replace the fifth paragraph of the test specification by the following:

The liquid container of the appliance is completely filled with the solution and a further

quantity equal to 15 % of the capacity of the container or 0,25 l, whichever is the greater, is

poured in steadily over a period of 1 min.
Add the following new text as a penultimate paragraph:

Any commercially available rinsing agent may be used, but if there is any doubt with regards

to the test results, the rinsing agent shall have the following properties:
– viscosity, 17 mPa⋅s;
– pH, 2,2 (1 % in water).
and its composition shall be
Substance Parts by mass
15,0
Plurafac ® LF 221
Cumene sulfonate (40 % solution) 11,5
Citric acid (anhydrous) 3,0
Deionized water 70,5
16 Leakage current and electric strength
16.2 Replace the first paragraph by the following:
An a.c. test voltage is applied between live parts and

– accessible metal parts intended to be connected to protective earth, for class l

appliances and class 0l appliances;

– metal foil having an area not exceeding 20 cm × 10 cm which is in contact with accessible

surfaces of insulating material and metal parts not intended to be connected to protective

earth, for class 0 appliances, class II appliances, class ll constructions and class III

appliances.
In the fourth paragraph, replace the first dashed item by the following:
– for class II appliances and for parts of class II construction 0,25 mA
—————————

Plurafac ® LF 221 is the trade name of a product supplied by BASF. This information is given for the

convenience of users of this document and does not constitute an endorsement by IEC of this product.

---------------------- Page: 9 ----------------------
– 8 – 60335-1 Amend. 1 © IEC:2013
19 Abnormal operation
19.7 Add the following to the fourth paragraph.

If the timer or programmer is an electronic type that operates to ensure compliance with the

test before the maximum period under the conditions of Clause 11 is reached, it is considered

to be a protective electronic circuit as well as a control that operates under the conditions

of Clause 11.
19.11.4.4 Replace the first paragraph by the following:

The power supply terminals of the appliance are subjected to voltage surges in accordance

with IEC 61000-4-5, five positive impulses and five negative impulses being applied at the

selected points. An open circuit test voltage of 2 kV is applicable for the line-to-line coupling

mode, a generator having a source impedance of 2 Ω being used. An open circuit test voltage

of 4 kV is applicable for the line-to-earth coupling mode, a generator having a source

impedance of 12 Ω being used.
22 Construction
22.5 In the requirement, replace “exceeding” by “equal to or greater than”.

Add the following text after the existing last paragraph of the test specification.

If compliance relies on the operation of an electronic circuit, the electromagnetic

phenomena tests of 19.11.4.3 and 19.11.4.4 are applied one at a time to the appliance. The

discharge test is then repeated three times and for each test, the voltage shall not exceed

34 V.

22.32 Replace the words ‘Insulating material’ at the beginning of the 4th paragraph of the

requirement by ‘Ceramic and similar porous material’ and combine this paragraph with the

third paragraph of the requirement.

22.33 Add the following to the first sentence of the first paragraph of the requirement:

“or unearthed metal parts that are separated from live parts by basic insulation only.”

22.35 In the second paragraph of the requirement add ‘and cordless appliances’ after

‘stationary appliances’.
Add the following note after the requirement:

NOTE A cordless appliance is an appliance that is connected to the supply only when placed on its associated

stand.
Add the following new subclauses:

22.53 Class II appliances and class III appliances that incorporate functionally earthed

parts shall have at least double insulation or reinforced insulation between live parts and

the functionally earthed parts.
Compliance is checked by inspection and test.
---------------------- Page: 10 ----------------------
60335-1 Amend. 1 © IEC:2013 – 9 –

22.54 Button cells and batteries designated R1 shall not be accessible without the aid of a

tool unless the cover of their compartment can only be opened after at least two independent

movements have been applied simultaneously.
Compliance is checked by inspection and by manual test.
NOTE Batteries are specified in IEC 60086-2.
23 Internal wiring
23.5 Replace Note 2 by the following text.

For class II construction, the requirements for supplementary insulation and reinforced

insulation apply except that the sheath of a cord complying with IEC 60227 or IEC 60245

may provide supplementary insulation.

A single layer of internal wiring insulation does not provide reinforced insulation.

24 Components

24.1 Replace Notes 1, 2, 3 and 4 by the following, and renumber Note 5 to Note 2.

Compliance with the IEC standard for the relevant component does not necessarily ensure

compliance with the requirements of this standard.

Motors are not required to comply with IEC 60034-1. They are tested as part of the appliance

according to this standard.

Relays shall be tested as part of the appliance according to this standard. They may be

alternatively tested to IEC 60730-1, in which case they must also meet the additional

requirements in IEC 60335-1.

Unless otherwise specified, the requirements of Clause 29 of this standard apply between live

parts of components and accessible parts of the appliance. Unless otherwise specified,

components may comply with the requirements for clearances and creepage distances for

functional insulation as specified in the relevant component standard.

Unless otherwise specified, the requirements of 30.2 of this standard apply to parts of non-

metallic material in components including parts of non-metallic material supporting current-

carrying connections inside components.

Components that have not been previously tested and shown to comply with the IEC standard

for the relevant component are tested according to the requirements of 30.2 of this standard.

Components that have been previously tested and shown to comply with the resistance to fire

requirements in the IEC standard for the relevant component need not be retested provided

that

− the severity specified in the component standard is not less than the severity specified in

30.2 of this standard, and

− unless the pre-selection alternatives in 30.2 are used, the test report for the component

states the values of t and t . as required by IEC 60695-2-11.
e i

If the above two conditions are not satisfied, the component shall be tested as part of the

appliance.
---------------------- Page: 11 ----------------------
– 10 – 60335-1 Amend. 1 © IEC:2013

NOTE 1 There are two levels of severity specified for appliances for which 30.2.3 is applicable.

Power electronic converter circuits are not required to comply with IEC 62477-1. They are

tested as part of the appliance according to this standard.
24.1.2 Add the following text as a new first paragraph.

The relevant standard for transformers in associated switch mode power supplies is Annex BB

of IEC 61558-2-16. Clause 26 of IEC 61558-1 and Annex H of IEC 61558-1 are not applicable.

24.1.4 Add the following new paragraph:

Thermal cut-outs of the capillary type shall comply with the requirements for type 2.K controls

in IEC 60730-2-9.

24.1.5 In the second sentence of the first paragraph, add “class II” before “appliances”.

25 Supply connection and external flexible cords
25.1 Replace the first dashed item of the requirement by the following:

– supply cord fitted with a plug, the current rating and voltage rating of the plug being not

less than the corresponding ratings of its associated appliance;
25.7 Delete the third dashed item in the first paragraph of the requirement.
25.10 Add the following as a new paragraph to the requirement.

In multi-phase appliances, the colour of the neutral conductor of the supply cord, if any, shall

be blue.
25.13 In the requirement, replace the second sentence by the following:

If it is not evident from the construction of the appliance that the supply cord can be

introduced without risk of damage, a non-detachable lining or non-detachable bushing

shall be provided that complies with 29.3 for supplementary insulation.
25.15 Replace the second paragraph of the test specification by the following:

A mark is made on the cord at a distance of approximately 20 mm from the cord anchorage or

other suitable point. The mark is made while the cord is subjected to a pull force of

– 100 N, for fixed appliances regardless of the mass of the appliance;
– the value as shown in Table 12, for other appliances.

25.20 Delete, in the first sentence, the word "insulated" in the phrase "insulated conductors

of the supply cord" and the word "additionally" in the phrase "shall be additionally insulated".

27 Provision for earthing

27.1 In the first paragraph of the requirement replace “an insulation fault” by “a failure of

basic insulation”.
Delete Note 1 and replace “Note 2” by “Note”.
---------------------- Page: 12 ----------------------
60335-1 Amend. 1 © IEC:2013 – 11 –
Replace the third paragraph by the following:

Class 0 appliances, class II appliances and class III appliances shall have no provision for

protective earthing. Class II appliances and class III appliances may incorporate an earth

for functional purposes.
27.2 Add the following paragraph to the requirement:

These requirements are not applicable to class II appliances and class III appliances that

incorporate an earth for functional purposes.
27.3 Add the following paragraph to the requirement:

These requirements are not applicable to class II appliances and class III appliances that

incorporate an earth for functional purposes.
27.4 Add the following paragraph to the requirement:

These requirements are not applicable to class II appliances and class III appliances that

incorporate an earth for functional purposes.
27.5 Add the following paragraph to the requirement:

These requirements are not applicable to class II appliances and class III appliances that

incorporate an earth for functional purposes.

Replace existing Note 1 by the following as an addition to the existing second paragraph of

the test specification.
The test is carried out until steady conditions have been established.

Replace existing Note 2 by the following as an addition to the last paragraph of the test

specification.
The resistance of the supply cord is not included in the resistance calculation.
Renumber existing Note 3 as Note.
27.6 Add the following sentence to the requirement:

This requirement is not applicable to class II appliances and class III appliances that

incorporate an earth for functional purposes.
28 Screws and connections

28.2 In the second paragraph of the requirement, replace bullets with dashes in the two

bulleted items.
29 Clearances, creepage distances and solid insulation
29.1 Add the following as a new second paragraph of the requirement:

For appliances intended for use at altitudes exceeding 2 000 m, the clearances in Table 16

shall be increased according to the relevant multiplier values in Table A.2 of IEC 60664-1.

---------------------- Page: 13 ----------------------
– 12 – 60335-1 Amend. 1 © IEC:2013
Add the following to the existing second paragraph of the requirement:
or to appliances intended for use at altitudes exceeding 2 000 m.
Delete Note 5.
Table 17 – Minimum creepage distances for basic insulation
Replace Note 1 by the following:

Lacquered conductors of windings are considered to be bare conductors but creepage distances for basic

insulation in other than a double insulation construction need not be greater than the associated clearance

specified in Table 16 taking into account 29.1.1.
29.3 Replace the third dashed item by the following:

– for insulation, other than single layer internal wiring insulation, by an assessment of the

thermal quality of the material combined with an electric strength test, in accordance with

29.3.3 and for accessible parts of reinforced insulation consisting of a single layer, by

measurement in accordance with 29.3.4, or
Add the following as the fourth dashed item of the test specification:

− by an assessment of the thermal quality of the material according to 29.3.3 combined with

an electric strength test in accordance with 23.5, for each single layer internal

...

Questions, Comments and Discussion