Amendment 2 - Discrete semiconductor devices and integrated circuits - Part 5-1: Optoelectronic devices - General

Amendement 2 - Dispositifs discrets à semiconducteurs et circuits intégrés - Partie 5-1: Dispositifs optoélectroniques - Généralités

General Information

Status
Replaced
Publication Date
24-Mar-2002
Current Stage
DELPUB - Deleted Publication
Completion Date
23-Feb-2016
Ref Project

Relations

Buy Standard

Standard
IEC 60747-5-1:1997/AMD2:2002 - Amendment 2 - Discrete semiconductor devices and integrated circuits - Part 5-1: Optoelectronic devices - General Released:3/25/2002 Isbn:2831862493
English and French language
15 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NORME CEI
INTERNATIONALE IEC
60747-5-1
INTERNATIONAL
STANDARD
AMENDEMENT 2
AMENDMENT 2
2002-03
Amendement 2
Dispositifs discrets à semiconducteurs
et circuits intégrés –
Partie 5-1:
Dispositifs optoélectroniques –
Généralités
Amendment 2
Discrete semiconductor devices
and integrated circuits –
Part 5-1:
Optoelectronic devices –
General
 IEC 2002 Droits de reproduction réservés  Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch  Web: www.iec.ch
CODE PRIX
H
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
Международная Электротехническая Комиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 60747-5-1 amend. 2  CEI:2002
AVANT-PROPOS
Le présent amendement a été établi par le sous-comité 47E: Dispositifs discrets à
semiconducteurs, du comité d'études 47 de la CEI: Dispositifs à semiconducteurs.
Le texte de cet amendement est issu des documents suivants:
FDIS Rapport de vote
47E/208/FDIS 47E/213/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
Le comité a décidé que le contenu de la publication de base et de ses amendements ne sera
pas modifié avant 2004. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
_____________
Page 4
Ajouter la nouvelle introduction suivante:
INTRODUCTION
La présente partie de la CEI 60747 fournit des informations de base sur les semiconducteurs:
– terminologie,
– symboles littéraux,
– valeurs limites et caractéristiques essentielles,
– méthodes de mesure,
– réception et fiabilité.
Page 48
Remplacer les paragraphes 6.4.6 à 6.4.16.1 existants par les nouveaux paragraphes 6.4.6 à
6.4.16.1 suivants:
6.4.6 Photocoupleur de protection contre les chocs électriques
Photocoupleur conçu pour maintenir une protection contre les chocs électriques après avoir
été soumis à des conditions de fonctionnement (limites de sécurité) qui excèdent les valeurs
limites spécifiées de fonctionnement normal.

60747-5-1 amend. 2  IEC:2002 – 3 –
FOREWORD
This amendment has been prepared by subcommittee 47E: Discrete semiconductor devices,
of IEC technical committee 47: Semiconductor devices.
The text of this amendment is based on the following documents:
FDIS Report on voting
47E/208/FDIS 47E/213/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until 2004. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
_____________
Page 5
Add the following new introduction:
INTRODUCTION
This part of IEC 60747 provides basic information on semiconductors:
– terminology,
– letter symbols,
– essential ratings and characteristics,
– measuring methods,
– acceptance and reliability.
Page 49
Replace the existing subclauses 6.4.6 to 6.4.16.1 with the following new subclauses 6.4.6 to
6.4.16.1:
6.4.6 Photocoupler providing protection against electrical shock
A photocoupler designed to maintain protection against electrical shock after it has been
subjected to operating conditions (safety ratings) that exceed the specified ratings (limiting
values) for normal operation.
– 4 – 60747-5-1 amend. 2  CEI:2002
6.4.7 Limites de sécurité (d'un photocoupleur pour une isolation renforcée)
Conditions de fonctionnement électrique, thermique et mécanique qui excèdent les valeurs
limites spécifiées d'un fonctionnement normal et auxquelles se réfèrent les exigences de
sécurité spécifiées.
6.4.8 Prescriptions de sécurité électrique
(d'un photocoupleur pour une isolation renforcée)
Prescriptions électriques à satisfaire et maintenir après que le photocoupleur a été soumis
aux limites de sécurité spécifiées afin d'en assurer la protection contre les chocs électriques.
NOTE Le photocoupleur peut devenir inopérant en permanence lorsque les limites de sécurité sont appliquées.
6.4.9 Décharge partielle (pd)
Décharge électrique localisée qui se produit dans l'isolement entre les bornes d'entrée et de
sortie du photocoupleur.
6.4.10 Charge apparente q , q
pd
Décharge électrique provoquée par une décharge partielle dans le photocoupleur.
6.4.11 Charge apparente de seuil q , q
pd(TH) TH
Valeur spécifiée de charge apparente aussi faible que techniquement mesurable et à laquelle
se réfèrent respectivement des valeurs mesurées de tension d’apparition ou de tension
d’extinction de décharges partielles.
NOTE 1 Une charge apparente de seuil de 5 pC a été estimée comme critère pratique pour les photocoupleurs.
Des valeurs plus petites sont désirables mais pas réalisables à présent.
NOTE 2 Dans les essais effectifs, ce critère s’applique à l’impulsion de charge apparente avec une valeur
maximale.
NOTE 3 Le terme «valeur de décharge spécifiée» (voir 1.3.18.2 de la CEI 60664-1) est synonyme de «charge
apparente de seuil».
6.4.12 Tensions d'essai (pour l'essai de décharge partielle d'un photocoupleur)
Voir la figure 14. Toutes les tensions utilisées sont des tensions de crête à courant alternatif.
6.4.12.1 Tension d'essai V , V
pd(t) t
Tension appliquée pendant la période d’essai entre les bornes d'entrée (reliées entre elles) et
les bornes de sortie (reliées entre elles) de l'éprouvette en essai.
Tension d'essai de décharges partielles: V
pd(t)
Tension d'isolement appliquée pendant la période d'essai de décharges partielles.
NOTE 1 Les valeurs spécifiées de cette tension peuvent être exprimées en un multiple de la valeur spécifiée de
la tension d'isolement assignée ou de la tension d'isolement de crête répétitive assignée: V = F × V ou
pd(m) IOWM
V = F × V , selon la plus élevée. Se reporter à 6.4.12.2 c), facteur multiplicateur.
pd(m) IORM
NOTE 2 Tension d’essai, pour laquelle la charge apparente doit être égale ou inférieure à la valeur spécifiée.

60747-5-1 amend. 2  IEC:2002 – 5 –
6.4.7 Safety ratings (of a photocoupler for reinforced isolation)
Electrical, thermal, and mechanical operating conditions that exceed the specified ratings
(limiting values) for normal operation, and to which the specified safety requirements refer.
6.4.8 Electrical safety requirements (of a photocoupler for reinforced isolation)
Electrical requirements that have to be met and maintained after the photocoupler has been
subjected to the specified safety ratings to ensure protection against electrical shock.
NOTE The photocoupler may become permanently inoperative when safety ratings are applied.
6.4.9 Partial discharge (pd)
Localized electrical discharge which occurs in the insulation between input and output
terminals of the photocoupler.
6.4.10 Apparent charge q , q
pd
Electrical discharge caused by a partial discharge in the photocoupler.
6.4.11 Threshold apparent charge q , q
pd(TH) TH
A specified value of apparent charge that is as small as technically feasible and to which
measured values of the partial-discharge inception voltage or extinction voltage, respectively,
refer.
NOTE 1 A threshold apparent charge of 5 pC was found to be a practicable criterion for photocouplers. Smaller
values are desirable but are not viable at this time.
NOTE 2 In actual tests, this criterion applies to the apparent charge pulse with the maximum value.
NOTE 3 The term "specified discharge magnitude" (see 1.3.18.2 of IEC 60664-1) is synonymous with "threshold
apparent charge".
6.4.12 Test voltages (for the partial-discharge test of a photocoupler)
See figure 14. All voltages used are a.c. peak voltages.
6.4.12.1 Test voltage V , V
pd(t) t
The voltage applied during the test period between the input terminals (connected together)
and the output terminals (connected together), respectively, of the specimen under test.
Partial discharge test voltage: V
pd(t)
The isolation voltage applied during the partial discharge test period.
NOTE 1 Specified values of this voltage may be expressed as a multiple of the specified value of the rated
isolation voltage or rated repetitive peak isolation voltage: V = F × V or V = F × V , whichever is
pd(m) IOWM pd(m) IORM
higher. Refer to 6.4.12.2 c), multiplying factor.
NOTE 2 Test voltage, where the apparent charge has to be equal or less than the specified value.

– 6 – 60747-5-1 amend. 2  CEI:2002
6.4.12.2 Tension d'essai initiale V , V
pd(ini) ini
Tension d'essai appliquée pendant le temps d'essai initial t .
ini
NOTE 1 La tension d’essai initiale est supérieure ou égale à la tension d’essai de la seconde partie de la période
d’essai pendant laquelle les caractéristiques de la décharge partielle sont mesurées; voir 6.4.12.3.
NOTE 2 Pour la méthode a), la valeur spécifiée de la tension d’essai initiale est égale à la valeur limite spécifiée
de la tension d’isolement de choc assignée V .
IOTM
NOTE 3 Pour la méthode b), la valeur spécifiée de la tension d’essai initiale (tension d'isolement) est égale ou
inférieure à la valeur limite spécifiée de la tension d’isolement de choc assignée V .
IOTM
a) Tension initiale: V ; V (voir le tableau 1 de la CEI 60664-1 pour les tensions
pd(ini),a ini,a
minimales; l'interpolation est possible.)
Valeur de la tension appliquée en début de la mesure, pendant une durée t , spécifiée,
ini
qui est censée simuler une surtension transitoire.
b) Tension d'essai initiale: V ; V
pd(ini),b ini,b
Tension d'essai d'isolement appliquée entre les bornes d'entrée court-circuitées et de
sortie court-circuitées à l'essai individuel de série (méthode b)). Tension de tenue égale
aux valeurs limites du fabricant avec un maximum de V .
IOTM
NOTE La valeur efficace équivalente d'une tension d'essai à courant alternatif peut également être utilisée.
c) Facteur multiplicateur: F
Au stade d'essai individuel de série: F = 1,875
Au stade de l'essai par échantillonnage et après les essais
de durée de vie, sous-groupe 1: F = 1,6
Après les essais de durée de vie, sous-groupes 2 et 3: F = 1,2
NOTE Lorsque le résultat d'essai utilisant les facteurs F ci-dessus est assurément affecté par la testabilité
concernant par exemple la taille de boîtier du dispositif, les sorties de boîtier ou le système d'essai, les facteurs F
suivants peuvent être choisis à la place par décision du fabricant: F = 1,6, F = 1,2 et F = 1,0 respectivement.
6.4.12.3 Tension de mesure de la charge apparente V , V
pd(m) m
Tension d'essai pour laquelle la charge apparente est mesurée.
6.4.13 Tension d'apparition de décharge partielle V , V
pd(i) i
Valeur de crête la plus faible d’une tension d’essai à courant alternatif à laquelle la charge
apparente est plus grande que la charge apparente de seuil spécifiée, si la tension d’essai est
augmentée à partir d'une valeur inférieure à laquelle aucune décharge partielle se produit.
NOTE La valeur efficace équivalente d'une tension d'essai à courant alternatif peut également être utilisée.
6.4.14 Tension d'extinction de décharge partielle V , V
pd(e) e
Valeur de crête la plus faible d’une tension d’essai à courant alternatif à laquelle la charge
apparente est plus petite que la charge apparente de seuil spécifiée, si la tension d’essai est
diminuée à partir d'une valeur supérieure à laquelle une telle décharge se produit.
NOTE La valeur efficace équivalente d'une tension d'essai à courant alternatif peut également être utilisée.

60747-5-1 amend. 2  IEC:2002 – 7 –
6.4.12.2 Initial test voltage V , V
pd(ini) ini
The test voltage applied during the initial test time t .
ini
NOTE 1 The initial test voltage is higher than or equal to the test voltage in the second part of the test period in
which partial discharge characteristics are measured; see 6.4.12.3.
NOTE 2 For method a), the specified value for the initial test voltage is equal to the specified limiting value of the
rated impulse isolation voltage V .
IOTM
NOTE 3 For method b), the specified value for the initial test voltage (isolation voltage) is equal to or lower than
the specified limiting value of the rated impulse isolation voltage V .
IOTM
a) Initial voltage: V ; V (see table 1 of IEC 60664-1 for minimum voltages,
pd(ini),a ini,a
interpolation is possible.)
The value of the voltage applied at the beginning of the measurement, for a specified time
t , which is intended to simulate the occurrence of a transient overvoltage.
ini
b) Initial test voltage: V ; V
pd(ini),b ini,b
The isolation test voltage applied between the short-circuited input and the short-circuited
output terminals at routine test (method b)). A withstand voltage equal to the manu-
facturer’s rating with a maximum of V .
IOTM
NOTE The equivalent r.m.s. value of an a.c. test voltage may also be used.
c) Multiplying factor: F
At routine test stage: F = 1,875
At sample test stage and after life tests, subgroup 1: F = 1,6
After life tests, subgroups 2 and 3: F = 1,2
NOTE When the test result using the above F factors is certainly affected by testability on, for example, the
device package size, package leads or the test system, the following F factors can be chosen instead by
manufacturer's decision: F = 1,6, F = 1,2 and F = 1,0 respectively.
6.4.12.3 Apparent charge measuring voltage V , V
pd(m) m
The test voltage for which apparent charge is measured.
6.4.13 Partial-discharge inception voltage V , V
pd(i) i
The lowest peak value of an a.c. test voltage at which the apparent charge is greater than the
specified threshold apparent charge, if the test voltage is increased from a lower value where
no partial discharge occurs.
NOTE The equivalent r.m.s. value of an a.c. test voltage may also be used.
6.4.14 Partial-discharge extinction voltage V , V
pd(e) e
The lowest peak value of an a.c. test voltage at which the apparent charge is smaller than the
specified threshold apparent charge, if the test voltage is reduced from a higher value where
such discharge occurs.
NOTE The equivalent r.m.s. value of an a.c. test voltage may also be used.

– 8 – 60747-5-1 amend. 2  CEI:2002
6.4.15 Intervalles de temps de la tension d'essai
Voir les termes et les symboles littéraux indiqués dans les figures 14a et 14b.
V
t
V ,
ini a
V
m
V
IORM
t
t t t
t
1 t 3 t 4
ini 2
m
t
st
IEC  684/02
t Temps initial (méthode a) uniquement)
ini
t Temps de contrainte (décharge partielle)
st
t Temps de mesure (décharge partielle)
m
t , t , t , t  Temps d'établissement
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.