Building intercom systems - Part 2: Requirements for advanced security building intercom systems (ASBIS)

IEC 62820-2:2017 specifies the technical requirements for the composition, function, performance and testing methods of Advanced Security Building Intercom Systems. This document is applicable for intercom systems used for any advanced security communication in buildings. Advanced security building intercom systems (ASBIS) are used for rapid emergency and danger messages verification by voice communication, warning of a danger, rapid notification of the responsible emergency services/intervention services and for sending instructions on how to proceed. The requirement for a suitable concept is prior risk assessment and a definition of the protection target.

Systèmes d'interphone de bâtiment - Partie 2: Exigences pour les systèmes d'interphone de bâtiment à sécurité avancée (ASBIS)

L'IEC 62820-2:2017 spécifie les exigences techniques relatives à la composition, aux fonctions, aux performances et aux méthodes d'essai des systèmes d'interphone de bâtiment à sécurité avancée. Le présent document s'applique aux systèmes d'interphone utilisés pour la communication à sécurité avancée dans les bâtiments. Les systèmes d'interphone de bâtiment à sécurité avancée (ASBIS) sont utilisés pour la vérification rapide de messages d'urgence et de danger par communication vocale, la mise en garde contre un danger, la notification rapide des services d'urgence/services d'intervention concernés et pour envoyer des instructions sur la conduite à adopter. L'exigence pour un concept adapté consiste en une évaluation préalable du risque et en une définition de la cible de la protection.

General Information

Status
Published
Publication Date
14-Sep-2017
Current Stage
PPUB - Publication issued
Start Date
15-Sep-2017
Completion Date
15-Sep-2017
Ref Project

Buy Standard

Standard
IEC 62820-2:2017 - Building intercom systems - Part 2: Requirements for advanced security building intercom systems (ASBIS)
English and French language
59 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (sample)

IEC 62820-2
Edition 1.0 2017-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Building intercom systems –
Part 2: Requirements for advanced security building intercom systems (ASBIS)
Systèmes d'interphone de bâtiment –
Partie 2: Exigences pour les systèmes d'interphone de bâtiment à sécurité
avancée (ASBIS)
IEC 62820-2:2017-09(en-fr)
---------------------- Page: 1 ----------------------
THIS PUBLICATION IS COPYRIGHT PROTECTED
Copyright © 2017 IEC, Geneva, Switzerland

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form

or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from

either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC

copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or

your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite

ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie

et les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des

questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez

les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC

The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes

International Standards for all electrical, electronic and related technologies.
About IEC publications

The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the

latest edition, a corrigenda or an amendment might have been published.
IEC Catalogue - webstore.iec.ch/catalogue Electropedia - www.electropedia.org

The stand-alone application for consulting the entire The world's leading online dictionary of electronic and

bibliographical information on IEC International Standards, electrical terms containing 20 000 terms and definitions in

Technical Specifications, Technical Reports and other English and French, with equivalent terms in 16 additional

documents. Available for PC, Mac OS, Android Tablets and languages. Also known as the International Electrotechnical

iPad. Vocabulary (IEV) online.

IEC publications search - www.iec.ch/searchpub IEC Glossary - std.iec.ch/glossary

The advanced search enables to find IEC publications by a 65 000 electrotechnical terminology entries in English and

variety of criteria (reference number, text, technical French extracted from the Terms and Definitions clause of

committee,…). It also gives information on projects, replaced IEC publications issued since 2002. Some entries have been

and withdrawn publications. collected from earlier publications of IEC TC 37, 77, 86 and

CISPR.
IEC Just Published - webstore.iec.ch/justpublished

Stay up to date on all new IEC publications. Just Published IEC Customer Service Centre - webstore.iec.ch/csc

details all new publications released. Available online and If you wish to give us your feedback on this publication or

also once a month by email. need further assistance, please contact the Customer Service

Centre: csc@iec.ch.
A propos de l'IEC

La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des

Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications IEC

Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la

plus récente, un corrigendum ou amendement peut avoir été publié.
Catalogue IEC - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
Application autonome pour consulter tous les renseignements
Le premier dictionnaire en ligne de termes électroniques et
bibliographiques sur les Normes internationales,
électriques. Il contient 20 000 termes et définitions en anglais
Spécifications techniques, Rapports techniques et autres
et en français, ainsi que les termes équivalents dans 16
documents de l'IEC. Disponible pour PC, Mac OS, tablettes
langues additionnelles. Egalement appelé Vocabulaire
Android et iPad.
Electrotechnique International (IEV) en ligne.
Recherche de publications IEC - www.iec.ch/searchpub
Glossaire IEC - std.iec.ch/glossary
65 000 entrées terminologiques électrotechniques, en anglais
La recherche avancée permet de trouver des publications IEC

en utilisant différents critères (numéro de référence, texte, et en français, extraites des articles Termes et Définitions des

comité d’études,…). Elle donne aussi des informations sur les publications IEC parues depuis 2002. Plus certaines entrées

projets et les publications remplacées ou retirées. antérieures extraites des publications des CE 37, 77, 86 et

CISPR de l'IEC.
IEC Just Published - webstore.iec.ch/justpublished
Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications IEC. Just

Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur cette

Disponible en ligne et aussi une fois par mois par email. publication ou si vous avez des questions contactez-nous:

csc@iec.ch.
---------------------- Page: 2 ----------------------
IEC 62820-2
Edition 1.0 2017-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Building intercom systems –
Part 2: Requirements for advanced security building intercom systems (ASBIS)
Systèmes d'interphone de bâtiment –
Partie 2: Exigences pour les systèmes d'interphone de bâtiment à sécurité
avancée (ASBIS)
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 13.320 ISBN 978-2-8322-4731-0

Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 3 ----------------------
– 2 – IEC 62820-2:2017 © IEC 2017
CONTENTS

FOREWORD ........................................................................................................................... 5

INTRODUCTION ..................................................................................................................... 7

1 Scope .............................................................................................................................. 8

2 Normative references ...................................................................................................... 8

3 Terms, definitions and abbreviated terms ........................................................................ 9

3.1 Terms and definitions .............................................................................................. 9

3.2 Abbreviated terms ................................................................................................. 13

4 Functional requirements ................................................................................................ 14

4.1 General ................................................................................................................. 14

4.2 Call function .......................................................................................................... 14

4.3 Unlocking function ................................................................................................ 14

4.4 Emergency call ..................................................................................................... 14

4.5 Manually controlled half duplex (non-simultaneous conversation) ......................... 15

4.6 High priority call .................................................................................................... 15

4.7 Direct communication between the security management units and

master-stations ..................................................................................................... 15

4.8 Audio and optical indicators .................................................................................. 15

4.9 Help call (call for assistance) ................................................................................ 15

4.10 Call queue ............................................................................................................ 15

4.11 Image transmission ............................................................................................... 15

4.12 Entrance warning message ................................................................................... 15

4.13 Event logs ............................................................................................................. 16

4.14 SMU system test ................................................................................................... 16

4.15 Overall system test ............................................................................................... 16

4.16 Intercom unit full duplex ........................................................................................ 16

4.17 Intercom unit voice switched duplex (automatic half duplex) ................................. 16

4.18 Intercom unit call queue ........................................................................................ 16

4.19 Intercom unit call transfer ..................................................................................... 16

4.20 Intercom unit keep on hold .................................................................................... 17

4.21 Intercom unit privacy protection ............................................................................ 17

4.22 Intercom unit privacy communication .................................................................... 17

4.23 Intercom unit microphone status ........................................................................... 17

4.24 System status monitoring ...................................................................................... 17

4.25 System event monitoring ....................................................................................... 17

4.26 System fault monitoring ........................................................................................ 17

4.27 Network security ................................................................................................... 17

4.28 Service staff and system administrators authentication and authorization ............. 18

4.29 Network authentication and authorisation .............................................................. 18

4.30 System access control .......................................................................................... 18

4.31 Deleted ................................................................................................................. 18

4.32 Interconnection security ........................................................................................ 18

4.33 Integrity protection ................................................................................................ 18

4.34 Building warnings distribution ................................................................................ 18

4.35 Environmental noise cancellation .......................................................................... 18

4.36 Void ...................................................................................................................... 19

4.37 Automatic aggression detection, (scream, shoot, glass-break, etc) ....................... 19

4.38 System redundancy .............................................................................................. 19

---------------------- Page: 4 ----------------------
IEC 62820-2:2017 © IEC 2017 – 3 –

4.39 Inductive loop ....................................................................................................... 19

4.40 Interfacing............................................................................................................. 19

4.41 User interface ....................................................................................................... 19

4.42 Software download/upgrade .................................................................................. 19

4.43 Void ...................................................................................................................... 20

4.44 System test ........................................................................................................... 20

4.45 Voice communication test ..................................................................................... 20

4.46 Error report ........................................................................................................... 20

4.47 Conversation transfer ............................................................................................ 20

5 Performance requirements............................................................................................. 20

5.1 General ................................................................................................................. 20

5.2 Audio characteristics ............................................................................................. 21

5.2.1 Acoustic pressure level .................................................................................. 21

5.2.2 Frequency response ...................................................................................... 21

5.2.3 Acoustic distortion ......................................................................................... 21

5.2.4 Channel S/N ratio .......................................................................................... 21

5.2.5 Side-tone masking rating (STMR) .................................................................. 21

5.2.6 Codec dependent parameters, receiving delay ............................................... 21

5.2.7 Audio switching time ...................................................................................... 21

5.2.8 Codec dependent parameters, sending delay ................................................ 21

5.2.9 Automatic volume control (AVC) .................................................................... 22

5.2.10 Speech transmission index (STI) ................................................................... 22

5.2.11 Transmission quality ...................................................................................... 22

5.2.12 Codec ............................................................................................................ 22

5.3 Other performances .............................................................................................. 22

5.3.1 System status monitoring ............................................................................... 22

5.3.2 System event monitoring ............................................................................... 22

5.3.3 System fault monitoring ................................................................................. 22

5.3.4 Number of speech channels .......................................................................... 23

5.3.5 Obsolete time ................................................................................................ 23

6 Test methods ................................................................................................................. 23

6.1 General ................................................................................................................. 23

6.2 The measurement of the frequency response ........................................................ 23

6.3 Acoustic pressure level ......................................................................................... 23

6.4 Acoustic distortion ................................................................................................ 23

6.5 Channel S/N ratio ................................................................................................. 23

6.6 Automatic volume control ...................................................................................... 23

6.7 Measurement of STI for laboratory test as well as for an onsite test of an

installed system .................................................................................................... 24

6.8 Other measurements ............................................................................................ 24

Annex A (normative) Pictograms: Symbols for important functions ...................................... 25

A.1 General ................................................................................................................. 25

A.2 Symbol for any call button (Door Bell): IEC 60417-5013:2002-10 .......................... 25

A.3 Symbol for call registration: IEC 60417-5090:2002-10 ........................................... 25

A.4 Symbol for established conversation: IEC 60417-5210:2011-05 ............................ 26

A.5 Symbol for: unlocked door: as ISO 7010 E058 but without arrow ........................... 26

A.6 Symbol for manually or automatically cancelling: IEC 60417-5576:2002-11 .......... 27

Annex B (normative) System composition ........................................................................... 28

Bibliography .......................................................................................................................... 29

---------------------- Page: 5 ----------------------
– 4 – IEC 62820-2:2017 © IEC 2017

Figure A.1 – Call button symbols .......................................................................................... 25

Figure A.2 – Call registration symbols ................................................................................... 25

Figure A.3 – Established conversation symbols .................................................................... 26

Figure A.4 – Unlocked door symbols ..................................................................................... 26

Figure A.5 – Call Cancel button symbols ............................................................................... 27

Figure B.1 – Composition of an ASBIS .................................................................................. 28

---------------------- Page: 6 ----------------------
IEC 62820-2:2017 © IEC 2017 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
BUILDING INTERCOM SYSTEMS –
Part 2: Requirements for advanced security
building intercom systems (ASBIS)
FOREWORD

1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising

all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international

co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in

addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,

Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their

preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with

may participate in this preparatory work. International, governmental and non-governmental organizations liaising

with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for

Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.

2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international

consensus of opinion on the relevant subjects since each technical committee has representation from all

interested IEC National Committees.

3) IEC Publications have the form of recommendations for international use and are accepted by IEC National

Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC

Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any

misinterpretation by any end user.

4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications

transparently to the maximum extent possible in their national and regional publications. Any divergence between

any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.

5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity

assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any

services carried out by independent certification bodies.

6) All users should ensure that they have the latest edition of this publication.

7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and

members of its technical committees and IEC National Committees for any personal injury, property damage or

other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses

arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.

8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is

indispensable for the correct application of this publication.

9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent

rights. IEC shall not be held responsible for identifying any or all such patent rights.

International Standard IEC 62820-2 has been prepared by IEC technical committee 79: Alarm

and electronic security systems.
The text of this International Standard is based on the following documents:
FDIS Report on voting
79/588/FDIS 79/590/RVD

Full information on the voting for the approval of this International Standard can be found in the

report on voting indicated in the above table.
---------------------- Page: 7 ----------------------
– 6 – IEC 62820-2:2017 © IEC 2017

This document has been drafted in accordance with the ISO/IEC Directives, Part 2.

A list of all parts in the IEC 62820 series, published under the general title Building intercom

systems, can be found on the IEC website.

The committee has decided that the contents of this document will remain unchanged until the

stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to

the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates

that it contains colours which are considered to be useful for the correct

understanding of its contents. Users should therefore print this document using a

colour printer.
---------------------- Page: 8 ----------------------
IEC 62820-2:2017 © IEC 2017 – 7 –
INTRODUCTION

The IEC 62820 series of standards set out the technical requirements for the composition,

functions, performance, test methods of building intercom systems for building entry and

application guidelines and consist of five parts:
Part 1-1: System requirements – General;

Part 1-2: System requirements – Building intercom systems using the internet protocol (IP);

Part 2: Requirements for advanced security building intercom systems (ASBIS);
Part 3-1 : Application guidelines – General;
Part 3-2 : Application guidelines – Advanced security building intercom systems.

IEC 62820-2 specifies higher security requirements, to be used in buildings with advanced

security needs that additionally or alternatively apply in respect of those in IEC 62820-1-1 and/or

IEC 62820-1-2 which give basic requirements for building intercom systems.

Additional requirements and recommendations are those described in IEC 62820-2, but they

are not covered by IEC 62820-1-1 neither IEC 62820-1-2.

Requirements and recommendations described by IEC 62820-2 have precedence, if also

described in IEC 62820-1-1 and/or IEC 62820-1-2.
___________
Under preparation. Stage at the time of publication: IEC/AFDIS 62820-3-1:2017.
Under preparation. Stage at the time of publication: IEC/AFDIS 62820-3-2:2017.
---------------------- Page: 9 ----------------------
– 8 – IEC 62820-2:2017 © IEC 2017
BUILDING INTERCOM SYSTEMS –
Part 2: Requirements for advanced security
building intercom systems (ASBIS)
1 Scope

This part of IEC 62820 specifies the technical requirements for the composition, function,

performance and testing methods of Advanced Security Building Intercom Systems.
This document is applicable for intercom systems used for any advanced security
communication in buildings.

Advanced security building intercom systems (ASBIS) are used for rapid emergency and danger

messages verification by voice communication, warning of a danger, rapid notification of the

responsible emergency services/intervention services and for sending instructions on how to

proceed. The requirement for a suitable concept is prior risk assessment and a definition of the

protection target.
A Security management unit (SMU) is a necessary part of an ASBIS.

The type of building and the usage of a building have influence on the risk calculation. In this

document, the relevant functions and performances are divided into three grades. According to

the results of the risk calculation, the security needs will be covered by an individual system

profile.

NOTE 1 Examples of typical profiles and each grades are defined in IEC 62820-3-2, where a risk calculation is

required.

NOTE 2 The application of this document does not dispense to comply with the public national regulations

concerning emergency systems.

NOTE 3 Systems for emergency purposes can be the subject of approval by local authorities.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content

constitutes requirements of this document. For dated references, only the edition cited applies.

For undated references, the latest edition of the referenced document (including any

amendments) applies.

IEC 60268-16, Sound system equipment – Part 16: Objective rating of speech intelligibility by

speech transmission index
IEC 60417, Graphical symbols for use on equipment (available at
http://www.graphical-symbols.info/equipment)

IEC 62820-1-1, Building intercom systems – Part 1-1: System requirements – General

IEC 62820-1-2, Building intercom systems – Part 1-2: System requirements – Building intercom

systems using the internet protocol (IP)

IEC 62820-3-2, Building intercom systems – Part 3-2: Application guidelines – Advanced

security building intercom systems
---------------------- Page: 10 ----------------------
IEC 62820-2:2017 © IEC 2017 – 9 –

IEC 62676 (all parts), Video surveillance systems for use in security applications

ISO 7010, Graphical symbols – Safety colours and safety signs – Registered safety signs

ITU-T G.722, 7 kHz audio-coding within 64 kbit/s

ITU-T P.79, Annex G, Telephone transmission quality, telephone installations, local line

networks

ITU-T P.311, Transmission characteristics for wideband digital handset and headset telephones

ITU-T P.340, Transmission characteristics and speech quality parameters of hands-free

terminals

ITU-T P.341, Transmission characteristics for wideband digital loudspeaking and hands-free

telephony terminals
ITU-T P.800, Methods for subjective determination of transmission quality
3 Terms, definitions and abbreviated terms
3.1 Terms and definitions

For the purposes of this document, the terms and definitions given in IEC 62820-1-1 and

IEC 62820-1-2 and the following apply.

ISO and IEC maintain terminological databases for use in standardization at the following

addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1.1
intercom unit
voice communication unit, inherent to the system

EXAMPLE Explosion-proof-unit, clean-room-unit, emergency-call-unit, heavy-duty-unit, school-class-room-unit.

Note 1 to entry: In this document, it includes all types of voice communication units, in addition to those defined in

IEC 62820-1-1 (VCU, URU, SMU).
3.1.2
full duplex

operating method in which transmission is possible simultaneously in both directions of a

telecommunication channel

Note 1 to entry: This means that both participants in an established conversation can speak and listen at the same

time. It is similar to a natural communication between persons while they are speaking and listening to each other

without any technical system between them.
3.1.3
manually contro
...

Questions, Comments and Discussion