Characterization of waste - Determination of selected polychlorinated biphenyls (PCB) in solid waste by using capillary gas chromatography with electron capture or mass spectrometric detection

This document specifies a method for quantitative determination of seven polychlorinated biphenyl congeners (PCB28, PCB52, PCB101, PCB118, PCB138, PCB153 and PCB180) in solid waste including sludge and soil using high-resolution gas chromatography with electron capture or mass spectrometric detection. The method is optimized for the above-mentioned congeners, but may include other PCB. The detection limits and quantification levels in this method are dependent on sample intake, the level of interferences as well as instrumental limitations. Under the conditions specified in this standard, minimum concentrations of individual PCB congeners equal or above 0,01 mg/kg dry matter can typically be determined with no interferences present.
NOTE 1   For the analysis of PCB in insulating liquids, petroleum products, used oils and aqueous samples is referred to EN 61619, EN 12766-1 and EN ISO 6468, respectively.
NOTE 2   When applying this method to the determination of other PCB congeners not specified in the scope its suitability should be proven by proper in-house validation experiments.

Charakterisierung von Abfällen - Bestimmung ausgewählter polychlorierter Biphenyle (PCB) in festem Abfall unter Anwendung der Kapillar-Gaschromatographie mit Elektroneneinfang-Detektion oder massenspektrometrischer Detektion

Dieses Dokument legt ein Verfahren zur quantitativen Bestimmung von sieben polychlorierten Biphenyl-
Congeneren (PCB-28, PCB-52, PCB-101, PCB-118, PCB-138, PCB-153 und PCB-180) in festem Abfall unter
Anwendung der hochauflösenden Gaschromatographie mit Elektroneneinfang- oder massenspektrometrischer
Detektion fest. Der Inhalt dieser Norm entspricht grundsätzlich dem der horizontalen PCB-Norm und ist
daher auch auf Boden, Schlamm und behandelten biogenen Abfall anwendbar. Die Detektion und die
Quantifizierungsgrenzen in diesem Verfahren sind von der Probenaufnahme, dem Interferenzniveau sowie
den instrumentellen Beschränkungen abhängig. Unter den in dieser Norm festgelegten Bedingungen können
typischerweise Mindestkonzentrationen einzelner PCB-Congenere von 0,01 mg/kg Trockenmasse oder
darüber bestimmt werden, wenn keine Interferenzen vorliegen.
ANMERKUNG 1 Für die Analyse von PCB in Isolierflüssigkeiten, Mineralölerzeugnissen, Gebrauchtölen und wässrigen
Proben wird jeweils auf EN 61619, EN 12766-1 und EN ISO 6468 verwiesen.
ANMERKUNG 2 Das Verfahren darf auf die Analyse weiterer, nicht im Anwendungsbereich festgelegter, PCBCongenere
angewendet werden, seine Anwendbarkeit sollte jedoch mit geeigneten laborinternen Validierungsuntersuchungen
nachgewiesen werden.

Caractérisation des déchets - Détermination de polychlorobiphényles (PCB) sélectionnés dans les déchets solides par chromatographie en phase gazeuse capillaire avec détection par capture d'électrons ou spectrométrie de masse

Le présent document décrit une méthode de détermination quantitative de sept congéneres de polychlorobiphényles (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153 et PCB 180) dans les déchets solides, y compris la boue et les sols par chromatographie en phase gazeuse haute résolution avec détection par capture d'électrons ou spectrométrie de masse. La méthode est optimisée pour les congéneres précités mais peut convenir a d'autres PCB. Les limites de détection et les niveaux de quantification de la présente méthode dépendent de la prise d'essai, du niveau des interférences ainsi que des limitations liées aux instruments. Dans les conditions définies par la présente norme, il est généralement possible de déterminer des concentrations minimales de PCB congéneres individuels supérieures ou égales a 0,01 mg/kg de matiere seche en l'absence d'interférences.
NOTE 1   Pour l'analyse des PCB dans les liquides isolants, les produits pétroliers, les huiles usagées et les échantillons aqueux, se référer respectivement aux normes EN 61619, EN 12766-1 et EN ISO 6468.
NOTE 2   En cas de détermination, par la présente méthode, de PCB congéneres autres que ceux décrits dans le domaine d'application, il convient d'en définir l'applicabilité par des tests de validation internes adaptés.

Karakterizacija odpadkov - Določevanje izbranih polikloriranih bifenilov (PCB) v trdnih odpadkih s kapilarno plinsko kromatografijo z detektorjem z zajemom elektronov (ECD) ali z masno spektrometrično detekcijo

General Information

Status
Withdrawn
Publication Date
04-May-2008
Withdrawal Date
06-Feb-2017
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
07-Feb-2017
Due Date
02-Mar-2017
Completion Date
07-Feb-2017

Relations

Buy Standard

Standard
EN 15308:2008
English language
38 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Charakterisierung von Abfällen - Bestimmung ausgewählter polychlorierter Biphenyle (PCB) in festem Abfall unter Anwendung der Kapillar-Gaschromatographie mit Elektroneneinfang-Detektion oder massenspektrometrischer DetektionCaractérisation des déchets - Détermination de polychlorobiphényles (PCB) sélectionnés dans les déchets solides par chromatographie en phase gazeuse capillaire avec détection par capture d'électrons ou spectrométrie de masseCharacterization of waste - Determination of selected polychlorinated biphenyls (PCB) in solid waste by using capillary gas chromatography with electron capture or mass spectrometric detection71.040.50Fizikalnokemijske analitske metodePhysicochemical methods of analysis13.030.10Trdni odpadkiSolid wastesICS:Ta slovenski standard je istoveten z:EN 15308:2008SIST EN 15308:2008en,fr,de01-julij-2008SIST EN 15308:2008SLOVENSKI
STANDARD



SIST EN 15308:2008



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 15308February 2008ICS 13.030.10; 13.030.20; 13.080.10 English VersionCharacterization of waste - Determination of selectedpolychlorinated biphenyls (PCB) in solid waste by using capillarygas chromatography with electron capture or massspectrometric detectionCaractérisation des déchets - Détermination depolychlorobiphényles (PCB) sélectionnés dans les déchetssolides par chromatographie en phase gazeuse capillaireavec détection par capture d'électrons ou spectrométrie demasseCharakterisierung von Abfällen - Bestimmung ausgewählterpolychlorierter Biphenyle (PCB) in festem Abfall unterAnwendung der Kapillar-Gaschromatographie mitElektroneneinfang-Detektion odermassenspektrometrischer DetektionThis European Standard was approved by CEN on 28 December 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2008 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15308:2008: ESIST EN 15308:2008



EN 15308:2008 (E) 2 Contents Page Foreword.3 1 Scope.4 2 Normative references.4 3 Terms and definitions.4 4 Principle.5 5 Reagents.5 6 Apparatus.9 7 Safety precautions.10 8 Interferences.10 9 Sample storage.10 10 Pre-treatment.11 11 Procedure.11 12 Performance characteristics.19 13 Test report.22 Annex A (informative)
Examples of GC/MS chromatograms of a calibration standard solution and a contaminated soil sample.23 Annex B (informative)
Examples of GC-ECD chromatograms of a calibration standard solution and a cable shredder sample.30 Annex C (informative)
Additional validation data.33 C.1 General.33 C.2 Type of samples and sample preparation.33 C.3 Homogeneity and stability.34 C.4 Extraction.35 C.5 Clean-up.35 C.6 Detection.35 C.7 PCB standard solution.35 Annex D (informative)
Summary of general requirements and recommendations.37 Bibliography.38
SIST EN 15308:2008



EN 15308:2008 (E) 3 Foreword This document (EN 15308:2008) has been prepared by Technical Committee CEN/TC 292 “Characterization of waste”, the secretariat of which is held by NEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2008, and conflicting national standards shall be withdrawn at the latest by August 2008. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
SIST EN 15308:2008



EN 15308:2008 (E) 4 1 Scope This document specifies a method for quantitative determination of seven polychlorinated biphenyl congeners (PCB-28, PCB-52, PCB-101, PCB-118, PCB-138, PCB-153 and PCB-180) in solid waste using high-resolution gas chromatography with electron capture or mass spectrometric detection. The basic content of this standard is identical to that of the Horizontal PCB-standard and is therefore also applicable to soil, sludge and treated bio-waste. The detection and the quantification limits in this method are dependent on sample intake, the level of interferences as well as instrumental limitations. Under the conditions specified in this standard, minimum concentrations of individual PCB congeners equal or above 0,01 mg/kg dry matter can typically be determined with no interferences present. NOTE 1 For the analysis of PCB in insulating liquids, petroleum products, used oils and aqueous samples is referred to EN 61619, EN 12766-1 and EN ISO 6468, respectively. NOTE 2 The method may be applied to the analysis of other PCB congeners not specified in the scope, but its suitability should be proven by proper in-house validation experiments. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 14346, Characterization of waste — Calculation of dry matter by determination of dry residue or water content 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 polychlorinated biphenyl PCB biphenyl substituted by one to ten chlorine atoms 3.2 congener member of the same kind, class or group of chemicals – e. g. anyone of the two hundred and nine individual PCB NOTE The IUPAC congener numbers are for easy identification; they do not represent the order of chromatographic elution. 3.3 calibration standard solution prepared from a secondary standard and/or stock solutions of native polychlorinated biphenyl congeners (PCB) and used to calibrate the response of the instrument with respect to analyte concentration 3.4 internal standard 13C12-labelled PCB or other PCB that are unlikely to be present in waste samples added to the sample before extraction and used for quantification of PCB content SIST EN 15308:2008



EN 15308:2008 (E) 5 3.5 injection standard 13C12-labelled PCB or other PCB that is unlikely to be present in waste samples added to the sample extract before injection into the gas chromatograph, to monitor variability of instrument response and the recovery of the internal standards 3.6 critical pair pair of congeners that must be separated to a predefined degree (e. g. R = 0,5) to ensure chromatographic separation meets minimum quality criteria 3.7 resolution Rs difference in retention times between the maxima of the two peaks i and j, which constitute the critical pair, divided by the arithmetic mean of the peak widths of i and j at base, calculated as:
()()bjbiRiRjs2wwttR+−= (1) where tRj and tRi are the retention times of the two peaks i and j (sec), and wbi and wbj are the peak widths of i and j (sec) at base 4 Principle A proper test portion is extracted with a mixture of organic solvents by an appropriate extraction technique (e. g. shaking, soxhlet, sonication), partitioned against water and the organic layer separated. The obtained extracts are concentrated and, if appropriate, cleaned-up. Sample cleanup procedures may include sulphuric acid treatment, Dimethylsulfoxide/n-Hexan partitioning, column chromatography on alumina and silica. Tetrabutylammonium sulfite (TBA) or copper may be used to remove sulfur if required. The extract is analyzed by gas chromatography with either mass spectrometric (GC-MS) or electron capture detection (GC-ECD). In case of GC-MS analysis quantification is performed by the isotope dilution technique. In case of GC-ECD, extracts are analyzed using two columns of different polarity. Quantification is conducted by the internal standard method. NOTE In case of plastic shredder a pure non-polar solvent should be used for extraction to prevent dissolving of the polymer matrix as far as possible. 5 Reagents 5.1 General All reagents shall be of recognized analytical grade. Running a blank determination as described in 11.1 shall check the purity of the reagents used. 5.2 Reagents for extraction and drying 5.2.1 Acetone. 5.2.2 Hexane like solvents with a boiling range of 36 °C to 98 °C, e. g. petroleum ether, n-hexane, n-heptane. SIST EN 15308:2008



EN 15308:2008 (E) 6 5.2.3 Anhydrous sodium sulfate, heated for at least 6 h to 550 °C ± 20 °C, cooled to about 200 °C in the furnace and then to ambient temperature in a desiccator containing magnesium perchlorate or another suitable drying reagent. The anhydrous sodium sulfate shall be kept carefully sealed. 5.3 Reagents for clean-up procedures 5.3.1 Aluminium oxide clean-up 5.3.1.1 One of two types of alumina, acidic or basic, can be used in the clean-up of sample extracts:  acidic alumina, activate by heating to 130 °C for a minimum of 12 h;  basic alumina, activate by heating to 600 °C for a minimum of 24 h. Preparation of deactivated aluminium oxide, the aluminium oxide is deactivated with 10 % water. To 90 g of aluminium oxide (5.3.1.1) add 10 g of water. Shake until all lumps have disappeared. Allow the aluminium oxide to condition before use for some 16 h, sealed from the air. NOTE ICN Alumina Super I or an equivalent may be used without activation. 5.3.2 TBA sulfite reagent for sulfur removal 5.3.2.1 Tetrabutylammonium reagent (TBA sulfite reagent); saturate a solution of tetrabutylammonium hydrogen sulfate in a mixture of equal volumina of water and 2-propanol, c((C4H9)4NHSO4) = 0,1 mol/l, with sodium sulfite. NOTE 25 g of sodium sulfite should be sufficient for 100 ml of solution. 5.3.3 Pyrogenic copper for sulfur removal WARNING — Pyrogenic copper is spontaneously inflammable. Suitable precautions should be taken. 5.3.3.1 Copper-(II)sulfate pentahydrate, Cu5SO4 · 5 H2O. 5.3.3.2 Hydrochloric acid, HCl, c = 2 mol/l. 5.3.3.3 Zinc granules, particle size 0,3 mm to 1,4 mm. 5.3.3.4 Anionic detergent aqueous solution (e. g. 35 % m/V n-dodecane-1-sulfonic acid sodium salt (CH3(CH2)11SO3Na)). 5.3.3.5 Deoxygenated water. 5.3.4 Silica – silver nitrate clean up 5.3.4.1 Silica gel (60 µm to 200 µm). 5.3.4.2 Silver nitrate, AgNO3. 5.3.4.3 Preparation of silica gel impregnated with silver nitrate. Dissolve 10 g of AgNO3 in 40 ml of water and give this mixture in portions to 90 g silica. Shake the mixture until it is homogenous and leave standing it for 30 min. Put the mixture into a drying oven at 70 °C. Within 5 h increase the temperature from 70 °C up to 120 °C. Activate the mixture for 15 h at 125 °C. Store the mixture in brown glass bottles. SIST EN 15308:2008



EN 15308:2008 (E) 7 5.3.5 Commercially available benzenesulfonic acid/silica gel cartridges, 3 ml 5.3.6 Dimethylsulfoxide/n-hexane partitioning 5.3.6.1 Dimethylsulfoxide (DMSO). 5.3.6.2 n-hexane. 5.3.7 Sulphuric acid clean-up 5.3.7.1 Sulphuric acid, 95 % to 97 %. 5.3.8 Silica gel/sulphuric acid clean-up 5.3.8.1 Silica/H2SO4 44 %: Pour 28 g of activated silica and 22 g of sulfuric acid in a flask, stopper air tight and shake thoroughly until disappearance of all agglomerates. 5.3.8.2 Silica/NaOH 33% 1N: pour 33,5 g of activated silica and 16,5 g 1N NaOH in a flask, stopper air tight and shake thoroughly until disappearance of all agglomerates. 5.3.9 Commercially available silica cartridges, 3 ml or 6 ml 5.3.10 Florisil clean up 5.3.10.1 Florisil1) 100 mesh to 200 mesh, activated by heating to 600 °C for a minimum of 2 h. 5.3.10.2 Iso-octane. 5.3.10.3 Iso-octane/Toluene 95/5. 5.4 Reagents for gas chromatographic analysis 5.4.1 Operating gases for gas chromatography, of high purity and in accordance with manufacturer's specifications. 5.5 Standard compounds 5.5.1 Calibration standards Use the following PCB for the calibration:  PCB-28: 2,4,4'-trichlorobiphenyl
(CAS number: 7012-37-5);  PCB-52: 2,2',5,5'-tetrachlorobiphenyl
(CAS number: 35693-99-3);  PCB-101: 2,2',4,5,5'-pentachlorobiphenyl
(CAS number: 37680-37-2);  PCB-118: 2,3',4,4',5-pentachlorobiphenyl
(CAS number: 31508-00-6);  PCB-138: 2,2',3,4,4',5'-hexachlorobiphenyl
(CAS number: 35056-28-2);
1) Florisil is a trade name for a prepared diatomaceous substance, mainly consisting of anhydrous magnesium silicate. This information is given for the convenience of users of this European Standard and does not constitute an endorsement by CEN of this product . Equivalent products may be used if it can be shown to lead to comparable results. SIST EN 15308:2008



EN 15308:2008 (E) 8  PCB-153: 2,2',4,4',5,5'-hexachlorobiphenyl
(CAS number: 35065-27-1);  PCB-180: 2,2',3,4,4',5,5'-heptachlorobiphenyl (CAS number: 35065-29-3). 5.5.2 Internal and injection standards 5.5.2.1 MS detection The labelled PCB congeners to be considered as internal standards are listed below.  13C-2,4,4’-trichlorobiphenyl (PCB-28);  13C-2,2‘,5,5‘-tetrachlorobiphenyl (PCB-52);  13C-2,2‘,4,5,5‘-pentachlorobiphenyl (PCB-101);  13C-2,3‘,4,4‘,5-pentachlorobiphenyl (PCB-118);  13C-2,2‘,3,4,4‘,5‘-hexachlorobiphenyl (PCB-138);  13C-2,2‘,4,4‘,5,5‘-hexachlorobiphenyl (PCB-153);  13C-2,2‘,3,4,4‘,5,5‘-heptachlorobiphenyl (PCB-180). 13C-2,2',3,3',5,5',6-heptachlorobiphenyl (PCB-178), other 13C-labelled PCB or PCB that are unlikely to be present in waste samples may be used as internal and injection standards as well.
NOTE The application of isotopic dilution mass spectrometry is recommended but adding 13C-labelled internal standards to the test portion before extraction is associated with high costs. Hence, if only an aliquot of the extract is subjected to the clean-up adding 13C-labelled internal standards to this aliquot might be a good option to ensure high quality of the analysis and to reduce costs. 5.5.2.2 ECD detection Also for ECD-detection internal and injection standards shall be added. Use at least one of the following standards unlikely to be present in waste samples and not interfering with the analytes as internal standard  PCB-29 – 2,4,5-trichlorobiphenyl
(CAS number: 15862-07-4);  PCB-30 – 2,4,6-trichlorobiphenyl
(CAS number: 35693-92-6);  PCB-143 - 2,2',3,4,5,6'-hexachlorobiphenyl
(CAS number: 68194-15-0);  PCB-155 - 2,2',4,4',6,6'-hexachlorobiphenyl
(CAS number: 33979-03-2);  PCB-198 - 2,2',3,3',4,5,5’,6,-octachlorobiphenyl
(CAS number: 68194-17-2);  PCB-207 - 2,2',3,3',4,4',5,6,6'-nonachlorobiphenyl
(CAS number: 52663-79-3);  PCB-209 - 2,2',3,3',4,4',5,5’,6,6'-decachlorobiphenyl (CAS number: 2051-24-3). NOTE For quantification (internal standard) PCB198 and PCB209 are recommended because of little interferences found in practice. Use of PCB 30 and PCB 209 for relative retention is recommended see EN 12766-1. 5.5.2.3 PCB congeners for resolution check  PCB-28 – 2,4,4'-trichlorobiphenyl (CAS number: 7012-37-5); SIST EN 15308:2008



EN 15308:2008 (E) 9  PCB-31 – 2,4',5-trichlorobiphenyl (CAS number: 16862-07-4). 6 Apparatus 6.1 Extraction and clean-up procedures 6.1.1 General Customary laboratory glassware. All glassware and material that comes into contact with the sample or extract shall be free of PCB and interfering compounds. 6.1.2 Extraction procedures 6.1.2.1 Glass sample bottles of proper size according to the amount of sample taken with glass stopper or screw top and polytetrafluorethene seal (PTFE). 6.1.2.2 Shaking device. With horizontal movement (200 min-1 to 300 min-1). 6.1.2.3 Water bath, adjustable up to 100 °C. 6.1.2.4 Separatory funnels of appropriate volume. 6.1.2.5 Conical flasks of appropriate volume. 6.1.2.6 Soxhlet extraction apparatus. Consisting of round bottom flask e. g.100 ml, Soxhlet extractors and soxhlet thimbles e. g. 27 mm × 100 mm, vertical condensers e. g. 300 mm, with water-bath or heating mantle as heating device. 6.1.2.7 Evaporator. Kuderna Danish or other evaporators, e. g. a rotary evaporator. 6.1.2.8 Analytical balance. 6.1.3 Clean-up procedures 6.1.3.1 Quartz wool or silanized glass wool. WARNING — Working with quartz wool imposes a risk to health through the release of fine quartz particles. Inhalation of these should be prevented by using a fume cupboard and wearing a dust mask. 6.1.3.2 Boiling chips, Glass or porcelain beads. 6.1.3.3 Calibrated test tubes with a capacity of 10 ml to 15 ml and ground glass stopper. 6.1.3.4 Glass chromatography columns of e. g. 600 mm length and 5 mm internal diameter. 6.1.3.5 Empty SPE-cartridge of e. g. 6 ml volume. SIST EN 15308:2008



EN 15308:2008 (E) 10 6.2 Gas chromatograph Equipped with a capillary column, mass spectrometric detector (MS) or electron capture detector (ECD) based on 63Ni. The injector shall be either an on-column injector, a split/splitless injector or a programmable temperature vaporiser injector. NOTE 1 Working with an encapsulated radioactive source, as present in an ECD requires a license according to the appropriate national radiation protection regulations. NOTE 2 Using ECD, gas chromatographs equipped with two detectors and with facilities for connecting two capillary columns to the same injection system are very well suited for this analysis; with such apparatus the confirmatory analysis can be performed simultaneously. 6.3 Capillary columns Comprising a non-polar stationary phase, e. g. 5 % phenyl-methyl silicone, coated onto a fused silica capillary column or an equivalent chemically bonded phase column. Use a chromatogram of a standard solution containing PCB-28 and PCB-31 (5.5.2.3) at equal concentrations run under identical conditions as samples for the determination of the resolution of the critical pair PCB-28/PC-B31.The resolution of this pair shall be better than 0,5. In general column lengths should be 25 m to 60 m, internal diameter 0,18 mm to 0,32 mm and film thickness 0,1 µm to 0,5 µm. Using ECD-detection, a column coated with a moderate polar phase, e. g. CP-Sil 19, OV 1701 etc., shall be used to confirm the result obtained on the non-polar column. Confirmation analysis using a second column is not necessary in case the analytical result is much below any regulatory level. 7 Safety precautions Anyone dealing with waste and sludge analysis has to be aware of the typical risks of that kind of material irrespective of the parameter to be determined. Waste and sludge samples may contain hazardous (e. g. toxic, reactive, flammable, infectious) substances, which can be liable to biological and/or chemical reaction. Consequently it is recommended that these samples should be handled with special care. The gases, which may be produced by microbiological or chemical activity, are potentially flammable and will pressurise sealed bottles. Bursting bottles are likely to result in hazardous shrapnel, dust and/or aerosol. National regulations should be followed with respect to all hazards associated with this method. 8 Interferences Some organic chlorinated compounds (e. g. tetrachlorobenzyltoluenes, polychlorinated naphthalenes, polychloninated terphenyls, toxaphenes, also sulphur) give rise to interferences since their behaviour is very similar to that of PCB during sample clean-up and gas chromatographic separation. It is possible that several PCB congeners elute within one peak. On many capillary columns PCB-138 coelutes with PCB-160, PCB-163 and PCB-164. Hence PCB-138 concentration may represent the sum of those congeners (also in case of mass spectrometric detection) The same is true for PCB-101 and PCB-90. Typically the concentrations of the co-eluating congeners compared to those of the target congeners are low. Presence of considerable amounts of mineral oil in the sample may interfere with the quantification of PCB in GC-MS analysis. In such cases, GC-ECD may be the preferred method or clean-up of the sample extract according to 11.3.8 using DMSO/n-hexane partitioning to remove the mineral oil from sample extract is recommended. 9 Sample storage In principle, the samples shall be analyzed as soon as possible after sampling. This applies in particular to the examination of microbiologically active solids. Field moist samples can be stored at a temperature of SIST EN 15308:2008



EN 15308:2008 (E) 11 4 °C ± 2 °C in sample containers in a dark place for a maximum of one week. If the sample cannot be processed within seven days, it has to be stored at temperatures below –18 °C. Dried samples shall be stored at room temperature in a dark place. 10 Pre-treatment 10.1 General The goal of a pre-treatment procedure is to prepare a test sample in which the content of the PCB congeners is not significantly changed compared to the laboratory sample. Due to the different properties of the various kinds of materials there is no general procedure available. Recommendations for sample pre-treatment are given in EN 15002 and ISO 14507. 10.2 Drying Depending on the nature of the sample material and the extraction solvent to be used a drying step might be needed. If it is necessary, air-dry the complete sample or dry it in a ventilated drying oven at 40 °C or in a freeze dryer. The drying time depends on the technique chosen and the nature of the sample. For sludge, freeze-drying is strictly applied. 10.3 Particle size reduction In order to achieve a homogeneous and representative test portion, one or more particle-size reduction steps might be needed. The choice of the technique depends on the nature of the sample and on the particle size needed. Typically, particle-size reduction is a multi-step operation that implies the use of a sequence of different techniques like crushing, cutting or grinding.
Grinding of samples which have a plastic or paste-like consistency requires embrittlement with liquid nitrogen and particle size reduction to less than 0,5 mm, e. g. by using an ultra-centrifugal mill. NOTE In case of plastic materials (e. g. cable shredder) the material to be granulated is poured in portions into liquid nitrogen and ground in a centrifugal mill (10 000 rounds/min to 15 000 rounds/min) cooled with liquid nitrogen. It should be noted that the mill is constantly kept cool by addition of liquid nitrogen in short intervals. The plastic material should be filled into the mill constantly in small portions without causing any significant slowing down of the grinder. 11 Procedure 11.1 Blank Perform a blank determination following the paragraphs of the procedure applied to samples (selected extraction and clean-up). Use the same amounts of reagents that are used for pre-treatment, extraction, clean up and analysis of samples. Analyse the blank immediately prior to analysis of the samples to demonstrate freedom from contamination. 11.2 Extraction 11.2.1 Extraction by shaking or sonification Weigh a test portion of 10 g to 25 g to the nearest 0,1 g in a stoppered flask. Add a definite volume of the internal standard solution. Isotopically labelled internal standards may be added after extraction to an aliquot of the extract where appropriate. Typically the concentration of the individual internal standards in the final extract will be 0,1 µg/ml. Add 50 ml of acetone to the test sample. Extract by shaking thoroughly for 30 min on a shaking device or by sonification. Then add 50 ml of hexane-like solvent (5.2.2) and extract again thoroughly SIST EN 15308:2008



EN 15308:2008 (E) 12 during 30 min. After the solids have settled decant the supernatant. Wash the remaining solids with 50 ml of hexane-like solvent (5.2.2) and decant again. Collect the extracts in a separatory funnel and remove the acetone by shaking twice with 400 ml of water. Dry the extract over anhydrous sodium sulfate. Filtrate or decant the extract and rinse the sodium sulfate three times with 10 ml of hexane-like solvent (5.2.2) and add the rinsings to the extract. Reduce the volume of the extract according to the applied clean-up procedure. NOTE In case of waste material with a high proportion of plastic, e. g. plastic shredder, extraction with an acetone containing solvent leads to a high amount of co-extractives. In these cases, extraction should be performed twice with 50 ml of hexane-like solvent (5.2.2). 11.2.2 Soxhlet extraction Weigh a test portion of 10 g to 25 g to the nearest 0,1 g in the extraction thimble. Add a definite volume of the internal standard solution. Isotopically labelled internal standards may be added after extraction to an aliquot of the extract where appropriate. Typically the concentration of the individual internal standards in the final extract will be 0,1 µg/ml. Add approximately 70 ml of the extraction mixture acetone/hexane-like solvent (5.2.1/5.2.2) 1:1 to the extraction vessel. Extract the sample for a minimum of 100 extraction cycles. Transfer the extract in a separatory funnel and remove the acetone by shaking twice with 400 ml of water. Dry the extract over anhydrous sodium sulfate. Filtrate or decant the extract and rinse the sodium sulfate three times with 10 ml of hexane-like solvent (5.2.2) and add the rinsings to the extract. Reduce the volume of the extract according to the applied clean-up procedure. NOTE 1 In case of waste material with a high proportion of plastic, e.g. plastic shredder, extraction with an acetone containing solvent leads to a high amount of co-extractives. In these cases, extraction should be performed with 50 ml of hexane-like solvent (5.2.2). NOTE 2 Other extraction techniques, e.g. acceler
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.