Decorative wall coverings - Roll and panel form

This European Standard applies to all forms of wallcovering products in roll and panel form as defined in
EN 235 supplied for hanging onto internal walls, partitions or ceilings, by means of an adhesive, whose primary purpose is decorative. However, certain wallcovering products may confer minor sound absorbtion and thermal resistance properties.
It also provides for the evaluation of conformity of products to the requirements of this standard.
It does not apply to wall coverings whose primary purpose is structural or protective (e.g. vapour or moisture barriers).

Dekorative Wandbekleidungen - Rollen- und Plattenform

Diese Europäische Norm gilt für alle Formen von Wandbekleidungsprodukten in Rollen  und Plattenform nach EN 235, die vorrangig zu dekorativen Zwecken an Innenwände, Trennwände oder Decken angeklebt werden. Bestimmte Wandbekleidungsprodukte können jedoch auch geringfügig zur Schallabsorption und zum Wärmedurchlasswiderstand beitragen.
Darüber hinaus wird die Bewertung der Konformität der Produkte mit den Anforderungen dieser Norm festgelegt.
Die Norm gilt nicht für Wandbekleidungen, die vorwiegend einen baulichen oder einen Schutzzweck erfüllen (z. B. Dampf  oder Feuchtigkeitssperren).

Revêtements muraux décoratifs - Rouleaux et panneaux

Dekorativne stenske obloge - Zvitki in plošče

Ta evropski standard velja za vse oblike stenskih oblog v zvitkih in ploščah, kot so opredeljene v EN 235, ki se z lepilom nalepijo na notranje stene, predelne stene ali strope in imajo predvsem okrasno funkcijo. Nekatere stenske obloge lahko omogočajo tudi manjše vpijanje zvoka in toplotno odpornost. Prav tako zagotavlja ocenjevanje skladnosti proizvodov z zahtevami tega standarda. Ne velja za stenske obloge, katerih glavna funkcija je strukturna ali zaščitna (npr. pregrade pred hlapi ali vlago).

General Information

Status
Withdrawn
Publication Date
11-Oct-2011
Withdrawal Date
25-Jun-2019
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
20-Jun-2019
Due Date
13-Jul-2019
Completion Date
26-Jun-2019

Relations

Buy Standard

Standard
EN 15102:2008+A1:2011
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Dekorative Wandbekleidungen - Rollen- und PlattenformRevêtements muraux décoratifs - Rouleaux et panneauxDecorative wall coverings - Roll and panel form91.180Interior finishingICS:Ta slovenski standard je istoveten z:EN 15102:2007+A1:2011SIST EN 15102:2008+A1:2011en,fr,de01-november-2011SIST EN 15102:2008+A1:2011SLOVENSKI
STANDARD



SIST EN 15102:2008+A1:2011



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 15102:2007+A1
September 2011 ICS 91.180 Supersedes EN 15102:2007English Version
Decorative wall coverings - Roll and panel form
Revêtements muraux décoratifs - Rouleaux et panneaux
Dekorative Wandbekleidungen - Rollen- und Plattenform This European Standard was approved by CEN on 23 September 2007 and includes Amendment 1 approved by CEN on 4 August 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15102:2007+A1:2011: ESIST EN 15102:2008+A1:2011



EN 15102:2007+A1:2011 (E) 2 Contents Page Foreword .41Scope .52Normative references .53Terms and definitions .64Characteristics .64.1!Reaction to fire" .64.2Release of formaldehyde .74.3!Release of other dangerous substances" .74.3.1Heavy metals and specific elements .74.3.2Release of vinyl chloride monomer .94.4Sound absorption .94.5Thermal resistance .95Evaluation of conformity .95.1General .95.2Initial type testing .95.2.1General .95.2.2Sampling, testing and compliance criteria . 105.3Factory production control (FPC) . 116Marking and labelling . 11Annex A (normative)
Factory production control . 12A.1General . 12A.2General requirements . 12A.3Equipment . 13A.3.1Testing . 13A.3.2Manufacturing . 13A.4Raw materials . 13A.5Product testing and evaluation . 13A.6Non-conforming products . 14A.7Traceability . 14A.8!Initial inspection of factory and of FPC . 14A.9Continuous surveillance of FPC" . 15Annex B (normative)
!Extended application rules within a group of product for the reaction to fire tests . 16B.1Sampling . 16B.2Product parameter having an influence on the product's fire performance of wall coverings . 16B.3End-use application parameters . 16B.4Tests conducted according to EN 13823 intended for an extended application . 17B.4.1Investigation of a group of product on different parameters . 17B.4.2Usage of the test results obtained during the first step . 17B.5Tests conducted according to EN ISO 11925-2 intended for an extended application . 17B.5.1Investigation of a group of product on different parameters . 17B.5.2Usage of the test results obtained during the first step" . 17Annex ZA (informative)
Relationship between this European Standard and the Essential Requirements of EU Directive 89/106/EEC, EU Construction Products Directive . 19ZA.1Scope and relevant characteristics . 19SIST EN 15102:2008+A1:2011



EN 15102:2007+A1:2011 (E) 3 ZA.2Procedures for the attestation of conformity of wallcovering products in roll or panel form . 20ZA.2.1Systems of attestation of conformity . 20ZA.2.2EC certificate of conformity and EC declaration of conformity . 23ZA.3CE marking and labelling. 24ZA.3.1General information for CE marking . 24ZA.3.2Minimum CE marking information . 24ZA.3.3Complete CE marking information . 25Bibliography . 27 SIST EN 15102:2008+A1:2011



EN 15102:2007+A1:2011 (E) 4 Foreword This document (EN 15102:2007+A1:2011) has been prepared by Technical Committee CEN/TC 99 “Wallcoverings”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by March 2012, and conflicting national standards shall be withdrawn at the latest by June 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. This document includes Amendment 1, approved by CEN on 2011-08-04. This document supersedes EN 15102:2007. The start and finish of text introduced or altered by amendment is indicated in the text by tags ! ". According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
SIST EN 15102:2008+A1:2011



EN 15102:2007+A1:2011 (E) 5
1 Scope This European Standard applies to all forms of wallcovering products in roll and panel form as defined in
EN 235 supplied for hanging onto internal walls, partitions or ceilings, by means of an adhesive, whose primary purpose is decorative. However, certain wallcovering products may confer minor sound absorbtion and thermal resistance properties. It also provides for the evaluation of conformity of products to the requirements of this standard. It does not apply to wall coverings whose primary purpose is structural or protective (e.g. vapour or moisture barriers). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 71-3:1994, Safety of toys — Part 3: Migration of certain elements EN 12149:1997, Wallcoverings in roll form — Determination of migration of heavy metals and certain other elements, of vinyl chloride monomer and of formaldehyde release EN 12524, Building materials and products — Hygrothermal properties — Tabulated design values EN 12667, Thermal performance of building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods — Products of high and medium thermal resistance EN 12781:2001, Wallcoverings — Specification for cork panels EN 13085:2001, Wallcoverings — Specification for cork rolls EN 13238, Reaction to fire tests for building products — Conditioning procedures and general rules for selection of substrates EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using data from reaction to fire tests !EN 13823, Reaction to fire tests for building products — Building products excluding floorings exposed to the thermal attack by a single burning item" EN ISO 354, Acoustics — Measurement of sound absorption in a reverberation room (ISO 354:2003) EN ISO 9001:2000, Quality management systems — Requirements (ISO 9001:2000) EN ISO 11654, Acoustics — Sound absorbers for use in buildings — Rating of sound absorption
(ISO 11654:1997) SIST EN 15102:2008+A1:2011



EN 15102:2007+A1:2011 (E) 6 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. !3.1 direct field of application of tests results outcome of a process (involving the application of defined rules) whereby a test result is deemed to be equally valid for variations in one or more of the product properties and/or intended end use applications 3.2 extended field of application of test results outcome of process (involving the application of defined rules that may incorporate calculation procedures) that predicts, for a variation of a product property and/or its intended end use application(s), a test result on the basis of one or more test results to the same test standard 3.3 product group range of products within defined limits of variability (defined by the manufacturer or a technical specification) of the product parameters and, if relevant, end-use parameters, for which the reaction to fire performance remains unchanged (does not get worse) 3.4 product parameter aspect of a product (for example thickness, composition, density) which can vary and have an influence on the product's fire performance 3.5 end use application real application of a product, in relation to all aspects that influence the behaviour of that product under different fire situations NOTE It covers aspects such as its quantity, its orientation, its position in relation to other adjacent products and its method of fixing (EN 13501-1). 3.6 end use application parameter aspect of the mounting and fixing arrangement of a product reflecting/simulating its end-use application (for example type of substrate, fixing method, position and type of joints) which can affect the fire performance" 4 Characteristics 4.1 !Reaction to fire Where use of a wall covering product as internal finishes on walls, partitions and/or ceilings is subject to the reaction to fire regulation requirements, its reaction to fire class (including the additional classification on smoke production and flaming droplets/particles, if any) shall be determined and declared according to EN 13501-1: a) either without the need for further testing (CWFT), as given in Table 1 1), if the wall covering product is proved to meet the requirements of the class given therein;
1) Table is the same as given in the Decision of the Commission 2010/82/EU of 2010-02-09 (see OJEU L38 of 2010-02-11). SIST EN 15102:2008+A1:2011



EN 15102:2007+A1:2011 (E) 7 b) or based on testing of the wall covering product according to the standards referred to in EN 13501-1, when the wall covering product does not meet the requirements of Table 1 or where a higher class than the one in a) is sought. NOTE
Class F may be declared, which is an equivalent to "No Performance Determined" (NPD) for this characteristic, when use of wall covering product is not subject to the national regulatory requirements on reaction to fire. Table 1 — Classes of reaction to fire performance for decorative wall coverings in roll and panel form Product a Maximum mass per unit area (g/m2) Maximum thickness (mm) Class b Wallcoverings on cellulose fibre base 190 0,9 D-s3, d2 Wallcoverings on cellulose fibre base and polymer coated or printed 470 0,7 Wallcoverings on a mixture of cellulose and polyester fibre base 160 0,3 Wallcoverings on a mixture of cellulose and polyester fibre base and polymer coated or printed 410 0,5 Wallcoverings on polymer coated fabric base 510 0,7 Wallcoverings of woven textile with a backing consisting of cellulose fibre or cellulose and polyester fibre 450 0,8 Wallcoverings of foamed PVC with a backing consisting of cellulose fibre or cellulose and polyester fibre 310 1,8 a Products in accordance with EN 15102 mounted on a substrate of at least class A2-s1,d0 with a minimum thickness 12 mm and with minimum density 800 kg/m3 using starch, or starch/PVA, or cellulose/PVA adhesive applied at a maximum 200 g/m2. b Class as provided for in Table 1 of the Annex to Commission Decision 2000/147/EC. When option b) is applied and where required by the test methods, the wallcovering product shall be tested in its end use conditions according to Annex B. In this case, the class declared shall be followed also by the associated mounting and fixing conditions (only if relevant for this class)." 4.2 Release of formaldehyde The release of formaldehyde from the wallcovering product shall be declared when subject to regulatory requirement and may be declared otherwise. The formaldehyde release, when tested in accordance with
Test C of EN 12149:1997 (as modified in Annex A of EN 12781:2001 or EN 13085:2001 for cork wallcovering products in panel form and roll form respectively) shall not exceed 120 mg/kg of wallcovering. If no formaldehyde or products containing formaldehyde are added during the manufacturing process of the wallcovering product, and the raw materials are declared by the supplier to contain less than 120 mg/kg of formaldehyde, then testing is not necessary. 4.3 !Release of other dangerous substances" 4.3.1 Heavy metals and specific elements 4.3.1.1 Requirements The migration of heavy metals and specific elements from the wallcovering product, expressed as mg/kg of wallcovering, shall not exceed the values given in !Table 2" (after correction according to 4.3.1.2) when measured in accordance with Test A of EN 12149:1997. If none of these substances are added during the SIST EN 15102:2008+A1:2011



EN 15102:2007+A1:2011 (E) 8 wallcovering manufacturing process, and all the raw materials are declared by the supplier to meet the requirements of !Table 2", then testing is not necessary. 4.3.1.2 Interpretation of results The analytical results on migration of heavy metals and specific elements from the wallcovering product, obtained from the tests specified in EN 12149:1997 shall be corrected by subtracting the value of the analytical correction factors given in !Table 3" in order to obtain a corrected analytical result. The wallcovering product shall be considered to meet the requirements of this European Standard if the corrected analytical result does not exceed the limits indicated in !Table 2". Given the precision of the methods specified in this European Standard, the corrected analytical result to take into account the results of inter-laboratory tests (see Annex D of EN 71-3:1994) shall be used. EXAMPLE: Analytical result for lead: 120 mg/kg. Corresponding analytical correction in Table 3: 30 %. Corrected analytical result = 120 − (120 × 30)/100 = 120 − 36 = 84 mg/kg. This is regarded as satisfying the requirements of the standard (i.e. lead ≤ 90 mg/kg). NOTE The measuring methods used in EN 12149:1997 are derived directly from EN 71-3:1994 on the safety of toys. Annex D of EN 71-3:1994, in particular D.4 ‘Statistical uncertainty of the test procedure and interpretation of results’ justifies the introduction of a correction factor. !Table 2" — Maximum migration of heavy metals and specific elements of wallcovering products Heavy metal or element Symbol Maximum migration in mg/kg
Antimony Sb No upper limit Arsenic As 25 Barium Ba 500 Cadmium Cd 25 Chromium Cr 60 Lead Pb 90 Mercury Hg 20 Selenium Se 165
!Table 3" — Analytical correction factor Element Sb As Ba Cd Cr Pb Hg Se Analytical correction factor (in percentage) 60 60 30 30 30 30 50 60
SIST EN 15102:2008+A1:2011



EN 15102:2007+A1:2011 (E) 9 4.3.2 Release of vinyl chloride monomer The release of vinyl chloride monomer (VCM) from the wallcovering product shall be declared when subject to regulatory requirement and may be declared otherwise. The maximum VCM release when tested to Test B of EN 12149:1997 shall not exceed 0,2 mg/kg of wallcovering. If no polyvinyl chloride or products containing vinyl chloride are used during the manufacturing process of the wallcovering product or if the raw materials used are declared by the supplier to contain less than 1 mg/kg of vinyl chloride monomer, then testing on VCM release is not necessary. 4.4 Sound absorption The sound absorption of the wallcovering product shall be declared when its intended end use is subject to regulatory requirement and may be declared otherwise. It shall be measured in accordance with EN ISO 354 and expressed as a single number rating according to EN ISO 11654. 4.5 Thermal resistance The thermal resistance of the wallcovering product shall be declared when its intended end use is subject to regulatory requirement and may be declared otherwise. The value shall either be taken from EN 12524 or the products shall be tested in accordance with EN 12667 and a value declared in m2K/W or W/(mK). 5 Evaluation of conformity 5.1 General The conformity of the wallcovering product with the requirements of this standard and with the stated values (including classes) shall be demonstrated by: - initial type testing, - factory production control by the manufacturer, including product assessment (see Annex A). For the purposes of testing, wallcovering products may be grouped into families !(see 3.3)". 5.2 Initial type testing 5.2.1 General Initial type testing shall be performed to show conformity of the wallcovering product with this standard. Tests previously performed in accordance with the provisions of this standard (same product, same characteristic(s), test method, sampling procedure, system of attestation of conformity, etc.) may be taken into account. In addition, initial type testing shall be performed at the beginning of the production of a new product type (unless a member of the same family) or at the beginning of a new method of production (where this may affect the stated properties). All characteristics in Clause 4 shall be subject to initial type testing. Whenever a change occurs in the product raw materials, raw material suppliers, or the production process (subject to the definition of a family), which may change significantly one or more of the characteristics given in Clause 4, then the initial type testing shall be repeated for the appropriate characteristic(s). SIST EN 15102:2008+A1:2011



EN 15102:2007+A1:2011 (E) 10 5.2.2 Sampling, testing and compliance criteria 5.2.2.1 Sampling procedure The sample of the wallcovering product taken for initial type testing shall be representative of normal production or, in the case of new products, samples representative of intended future production. Whenever practicable, the random sampling method shall be used, in which every product in a batch has an equal chance of being selected for the sample. The required numbers of product shall be selected from a batch at random, without any consideration given to the condition or quality of the selected products. When random sampling is impracticable, e.g. when the products form a large stack or stacks with ready access to only a limited number of products, a representative sampling procedure shall be used. 5.2.2.2 Testing and compliance criteria The testing and compliance criteria are given in !Table 4". The results of all initial type testing shall be recorded and held by the manufacturer for at least 5 years after the last date of production of the wallcovering product to which they relate. !Table 4 — Testing and compliance criteria for initial type testing of the wall covering product Characteristic Requirement clause Assessment method Number of specimens Conformity criteria Reaction to fire 4.1 a) See Note 1 See Note 1 Table 1 4.1 b) Tests referred to from EN 13501-1 (testing) As required by the appropriate test standard See classification in EN 13501-1 Release of formaldehyde 4.2 EN 12149:1997 (EN 12781:2001 or EN 13085:2001 for cork products) As required by the appropriate test standard See 4.2 Release of heavy metals and specific elements 4.3.1 EN 12149:1997 As required by the test standard See 4.3.1.2 Release of vinyl chloride monomer (VCM) 4.3.2 EN 12149:1997 As required by the test standard See 4.3.2 Sound absorption 4.4 EN ISO 354 (testing) EN ISO 11654 (classification) See note 2 See 4.4 Thermal resistance 4.5 EN 12667 See note 2 See 4.5 EN 12524 NOTE 1
Although no direct testing of reaction to fire is needed for CWFT products, indirect testing of product parameters can be necessary to ensure that the product meets the definition required for CWFT status. NOTE 2
Three specimens, each sample from a separate unit, with units selected according to the procedure of 5.2.2.1. " SIST EN 15102:2008+A1:2011



EN 15102:2007+A1:2011 (E) 11 5.3 Factory production control (FPC) The manufacturer shall establish, document and maintain an FPC system to ensure that the subsequent wallcovering products placed on the market conform to the declared performance characteristics obtained on the basis of initial type testing. The FPC system shall consist of procedures, regular inspections and tests and/or assessments and the use of the results to control raw and other incoming materials or components, equipment, the production process and the product. The FPC system shall comply with at least the requirements of Annex A. 6 Marking and labelling When compliance with this European Standard is claimed, the wallcovering product, its packaging or a label inside the packaging shall display the following information in such a way that it can be read without removing the wallcovering product from the packaging: a) number of this standard, i.e. EN 15102; b) manufacturer's or supplier's identification; c) product name and batch number (possibly in code form). NOTE Where ZA.3 covers the same requirements as this clause, the requirements of this clause are met.
SIST EN 15102:2008+A1:2011



EN 15102:2007+A1:2011 (E) 12 Annex A (normative)
Factory production control A.1 General The manufacturer shall establish, document and maintain a factory production control (FPC) system to ensure that the subsequent wallcovering products placed on the market conform to the declared performance characteristics. The FPC system shall consist of procedures, regular inspections and tests and/or assessments and the use of the results to control raw and other incoming materials or components, equipment, the production process and the product. All the elements, requirements and provisions adopted by the manufacturer shall be documented in a systematic manner in the form of written policies and procedures. This production control system documentation shall ensure a common understanding of the conformity evaluation and enable the achievement of the required product characteristics and the effective operation of the production control system to be checked. Factory production control therefore brings together operational techniques and all measures allowing maintenance and control of the conformity of the product with its technical specifications. Its implementation may be achieved by controls and tests on measuring equipment, raw materials, processes, machines and manufacturing equipment and finished product, and by making use of the results thus obtained. A.2 General requirements As a minimum, the FPC system shall fulfil the requirements as described in the following clauses of EN ISO 9001:2000, where applicable: – 4.2 (except 4.2.1 a)), – 5.1e), 5.5.1, 5.5.2, – Clause 6, – 7.1 (except 7.1 a)), 7.2.3 c), 7.4, 7.5, 7.6, – 8.2.3, 8.2.4, 8.3, 8.5.2. The FPC system shall: – be made specific to the products covered by this European Standard, and – ensure that the products placed on the market conform to the declared performance characteristics. The FPC system may be part of a quality management system, e.g. in accordance with EN ISO 9001:2000. The results of inspections, tests or assessments requiring action shall be recorded, as shall any action taken. The action to be taken when control values or criteria are not met shall be recorded and retained for the period specified in the manufacturer's FPC procedures. SIST EN 15102:2008+A1:2011



EN 15102:2007+A1:2011 (E) 13 A.3 Equipment A.3.1 Testing All weighing, measuring, and testing equipment shall be calibrated and regularly inspected according to documented procedures
...

Questions, Comments and Discussion