(Main)Method to calculate GHG emissions at LNG plant (ISO 6338:2023)
- Abstract
This document provides a method to calculate the GHG emissions from an LNG liquefaction plant, onshore or offshore.
The frame of this document ranges from the inlet flange of the LNG plant’s inlet facilities up to and including the offloading arms to truck, ship or railcar loading. The upstream supply of gas up to the inlet flange of the inlet facilities and the distribution of LNG downstream of the loading arms are only covered in general terms.
This document covers:
— all facilities associated with producing LNG, including reception facilities, condensate unit (where applicable), pre-treatment units (including but not limited to acid gas removal, dehydration, mercury removal, heavies removal), LPG extraction and fractionation (where applicable), liquefaction, LNG storage and loading, Boil-Off-Gas handling, flare and disposal systems, imported electricity or on-site power generation and other plant utilities and infrastructure (e.g. marine and transportation facilities).
— natural gas liquefaction facilities associated with producing other products (e.g. domestic gas, condensate, LPG, sulphur, power export) to the extent required to allocate GHG emissions to the different products.
— all GHG emissions associated with producing LNG. These emissions spread across scope 1, scope 2 and scope 3 of the responsible organization. Scope 1, 2 and 3 are defined in this document. All emissions sources are covered including flaring, combustion, cold vents, process vents, fugitive leaks and emissions associated with imported energy.
The LNG plant is considered “under operation”, including emissions associated with initial start-up, maintenance, turnaround and restarts after maintenance or upset. The construction, commissioning, extension and decommissioning phases are excluded from this document but can be assessed separately.
The emissions resulting from boil-off gas management during loading of the ship or any export vehicle are covered by this document. The emissions from a ship at berth, e.g. mast venting are not covered by this document.
This document describes the allocation of GHG emissions to LNG and other hydrocarbon products where other products are produced (e.g. LPG, domestic gas, condensates, sulphur, etc.).
This document defines preferred units of measurement and necessary conversions.
This document also recommends instrumentation and estimations methods to monitor and report GHG emissions. Some emissions are measured and some are estimated.
This document is applicable to the LNG industry.
Applications include the provision of method to calculate GHG emissions through a standardized and auditable method, a means to determine their carbon footprint.
- Status
- Published
- Public Enquiry End Date
- 01-Jun-2026
- Publication Date
- 22-Jul-2026
- Technical Committee
- DPL - Gas supply
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 22-Jul-2026
- Due Date
- 26-Sep-2026
- Completion Date
- 23-Jul-2026
SIST EN ISO 6338:2026 is the CEN European Standard that adopts ISO 6338:2023 without modification. It specifies a method to calculate greenhouse gas (GHG) emissions at LNG liquefaction plants, onshore or offshore, for organizations that need a standardized and auditable carbon-footprint calculation. The document also covers allocation to LNG and co-products, reporting, quality management, and independent review.
What does SIST EN ISO 6338:2026 specify?
SIST EN ISO 6338:2026 specifies how to quantify GHG emissions from an LNG liquefaction plant from the inlet flange of the inlet facilities to the offloading arms for truck, ship, or railcar loading. The standard is written for the LNG industry and is intended to support a consistent, auditable method for calculating emissions and carbon footprint.
The scope includes the plant facilities linked to LNG production, such as receiving, pretreatment, liquefaction, storage, loading, boil-off-gas handling, flare and disposal systems, utilities, and supporting infrastructure. It also covers plants that produce co-products such as domestic gas, LPG, condensate, sulphur, or power export, where emissions must be allocated between outputs.
The document treats the LNG plant as under operation, including start-up, maintenance, turnaround, and restart emissions. It excludes construction, commissioning, extension, and decommissioning, and it only covers boil-off-gas management during loading, not emissions from a ship at berth.
| Annex | What it covers |
|---|---|
| Annex A | Conversion factors for reference |
| Annex B | International initiatives on climate ambitions |
| Annex C | Example allocation calculation |
What are the key requirements of SIST EN ISO 6338:2026?
Boundaries, sources, and data collection
SIST EN ISO 6338:2026 requires the reporting boundary to cover all facilities associated with LNG production, and the organization with financial and/or operational control must report emissions and removals at least on an annual average basis. The practical effect is that site teams need a clearly defined inventory boundary before they start calculation work.
The standard requires operators to identify emission sources across fuel combustion, flaring and venting, fugitive emissions, and imported energy, utilities, and consumables. It prefers primary data for major sources, with secondary data used only when primary data are not available.
Calculation methods and emission factors
SIST EN ISO 6338:2026 says emission calculations shall follow the API Consistent Methodology for Estimating Greenhouse Gas Emissions from Liquefied Natural Gas (LNG) Operations. It also requires the calculation approach used for each evaluation to be stated, because data quality affects the result.
For emission factors, the standard points to measured flowrate, composition, and combustion efficiency as the preferred inputs. Where measurements are unavailable, it allows calculated or estimated approaches, such as heat and material balances, periodic sampling, vendor efficiency data, or standard emission factors.
Flaring, venting, fugitives, and imported energy
SIST EN ISO 6338:2026 gives separate treatment to major source groups so operators can choose methods that fit the plant and the data available. In practice, this means different instruments or estimation methods may be used for different emission streams.
- Flaring and venting: significant events should be quantified with primary data where possible, and combustion or destruction efficiency should be validated against field data.
- Fugitive emissions: the standard allows screening, component counts, leakage factors, direct measurement, or engineering calculations, with at least annual monitoring.
- Imported energy, utilities, and consumables: the standard prefers supplier-specific data and, where needed, supply-chain accounting in line with ISO 14044.
- Preferred unit of intensity: gCO2e/MJ of exported product, with the heating value stated; tCO2e/tLNG is also allowed if reported with the LNG heating value.
Allocation, carbon capture, quality, and reporting
SIST EN ISO 6338:2026 requires allocation of GHG emissions to LNG and other commercial products using the hierarchy from ISO 14044. The practical meaning is that co-product plants should not simply divide emissions by product energy content if that would understate LNG’s share.
The allocation method breaks the plant into process blocks, assigns emissions to the blocks based on where benefits are received, and then allocates block emissions to product streams. It also states that emissions shall not be allocated to waste products.
The standard includes carbon capture treatment: CCUS emissions must be counted in the facility balance, and the capture benefit is based on capture efficiency and system availability. It also requires quality management for inventory compilation, uncertainty estimation, documentation and archiving, quality control, quality assurance, and independent review.
What terms does SIST EN ISO 6338:2026 define?
- Facility - A single installation, set of installations, or production processes that can be defined within one geographical boundary, organizational unit, or production process.
- Global warming potential (GWP) - The ratio of warming from releasing 1 kg of a GHG to the warming from 1 kg of CO2.
- Greenhouse gas (GHG) - A gaseous atmospheric constituent that absorbs and emits infrared radiation.
- Organizational boundary - The activities or facilities under operational control, financial control, or equity share.
- Reporting boundary - The emissions and removals reported from within the organizational boundary plus significant indirect emissions linked to the organization’s activities.
- Scope 1 - Direct GHG emissions from sources owned or controlled by the facility.
- Scope 2 - Indirect GHG emissions from purchased and consumed energy such as imported electricity, steam, heating, or cooling.
- Scope 3 - Other indirect GHG emissions from sources not owned or directly controlled by the facility.
Who uses SIST EN ISO 6338:2026?
SIST EN ISO 6338:2026 is used by LNG plant owners and operators, especially where the plant is onshore or offshore and where emissions must be reported across the full LNG production boundary. It is also relevant to environmental, sustainability, process, and utilities teams that compile the GHG inventory.
Quality managers, internal auditors, and third-party reviewers can use it to check whether the inventory is traceable, consistent, and documented. Buyers, off-takers, and other stakeholders can use the reported results when they need a carbon-footprint basis that is auditable and comparable over time.
What changed in SIST EN ISO 6338:2026 from the previous edition?
SIST EN ISO 6338:2026 takes over ISO 6338:2023 as SIST EN ISO 6338:2026 without modification.
Which standards are used with SIST EN ISO 6338:2026?
SIST EN ISO 6338:2026 cites ISO 14044 for life cycle assessment requirements and allocation hierarchy, and ISO 14064-1 for GHG inventory terms, principles, and reporting guidance. It also requires emissions calculations to follow the API Consistent Methodology for Estimating Greenhouse Gas Emissions from Liquefied Natural Gas (LNG) Operations.
The document also names related standards and guidance that support use cases around verification, reporting, and emissions estimation, including ISO 14064-2, ISO 14064-3, ISO 14065, ISO 14066, ISO 14067, PAS 2060, CEN/TS 17874, EPA AP-42, EPA Method-21, the GHG Protocol Scope 2 guidance, IEA emission factors, and IPCC good practice guidance. These references help with project accounting, verification, carbon neutrality claims, fugitives, and imported-energy calculations.
What does the SIST EN ISO 6338:2026 document contain?
The document contains a clause structure that moves from scope and references to terms, principles, inventory boundaries, quantification, quality management, reporting, and independent review. Clause 6 is the technical core, with source-specific methods for fuel combustion, flaring and venting, fugitive emissions, imported energy and consumables, allocation, and carbon capture.
The annexes give supporting material rather than new requirements. Annex A lists unit conversion factors, Annex B summarizes climate-ambition initiatives and related KPI expectations, and Annex C walks through a worked example of allocation for a hypothetical LNG plant.
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

Bureau Veritas
Bureau Veritas is a world leader in laboratory testing, inspection and certification services.

DNV
DNV is an independent assurance and risk management provider.
Sponsored listings
Frequently Asked Questions
SIST EN ISO 6338:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Method to calculate GHG emissions at LNG plant (ISO 6338:2023)". This standard covers: This document provides a method to calculate the GHG emissions from an LNG liquefaction plant, onshore or offshore. The frame of this document ranges from the inlet flange of the LNG plant’s inlet facilities up to and including the offloading arms to truck, ship or railcar loading. The upstream supply of gas up to the inlet flange of the inlet facilities and the distribution of LNG downstream of the loading arms are only covered in general terms. This document covers: — all facilities associated with producing LNG, including reception facilities, condensate unit (where applicable), pre-treatment units (including but not limited to acid gas removal, dehydration, mercury removal, heavies removal), LPG extraction and fractionation (where applicable), liquefaction, LNG storage and loading, Boil-Off-Gas handling, flare and disposal systems, imported electricity or on-site power generation and other plant utilities and infrastructure (e.g. marine and transportation facilities). — natural gas liquefaction facilities associated with producing other products (e.g. domestic gas, condensate, LPG, sulphur, power export) to the extent required to allocate GHG emissions to the different products. — all GHG emissions associated with producing LNG. These emissions spread across scope 1, scope 2 and scope 3 of the responsible organization. Scope 1, 2 and 3 are defined in this document. All emissions sources are covered including flaring, combustion, cold vents, process vents, fugitive leaks and emissions associated with imported energy. The LNG plant is considered “under operation”, including emissions associated with initial start-up, maintenance, turnaround and restarts after maintenance or upset. The construction, commissioning, extension and decommissioning phases are excluded from this document but can be assessed separately. The emissions resulting from boil-off gas management during loading of the ship or any export vehicle are covered by this document. The emissions from a ship at berth, e.g. mast venting are not covered by this document. This document describes the allocation of GHG emissions to LNG and other hydrocarbon products where other products are produced (e.g. LPG, domestic gas, condensates, sulphur, etc.). This document defines preferred units of measurement and necessary conversions. This document also recommends instrumentation and estimations methods to monitor and report GHG emissions. Some emissions are measured and some are estimated. This document is applicable to the LNG industry. Applications include the provision of method to calculate GHG emissions through a standardized and auditable method, a means to determine their carbon footprint.
This document provides a method to calculate the GHG emissions from an LNG liquefaction plant, onshore or offshore. The frame of this document ranges from the inlet flange of the LNG plant’s inlet facilities up to and including the offloading arms to truck, ship or railcar loading. The upstream supply of gas up to the inlet flange of the inlet facilities and the distribution of LNG downstream of the loading arms are only covered in general terms. This document covers: — all facilities associated with producing LNG, including reception facilities, condensate unit (where applicable), pre-treatment units (including but not limited to acid gas removal, dehydration, mercury removal, heavies removal), LPG extraction and fractionation (where applicable), liquefaction, LNG storage and loading, Boil-Off-Gas handling, flare and disposal systems, imported electricity or on-site power generation and other plant utilities and infrastructure (e.g. marine and transportation facilities). — natural gas liquefaction facilities associated with producing other products (e.g. domestic gas, condensate, LPG, sulphur, power export) to the extent required to allocate GHG emissions to the different products. — all GHG emissions associated with producing LNG. These emissions spread across scope 1, scope 2 and scope 3 of the responsible organization. Scope 1, 2 and 3 are defined in this document. All emissions sources are covered including flaring, combustion, cold vents, process vents, fugitive leaks and emissions associated with imported energy. The LNG plant is considered “under operation”, including emissions associated with initial start-up, maintenance, turnaround and restarts after maintenance or upset. The construction, commissioning, extension and decommissioning phases are excluded from this document but can be assessed separately. The emissions resulting from boil-off gas management during loading of the ship or any export vehicle are covered by this document. The emissions from a ship at berth, e.g. mast venting are not covered by this document. This document describes the allocation of GHG emissions to LNG and other hydrocarbon products where other products are produced (e.g. LPG, domestic gas, condensates, sulphur, etc.). This document defines preferred units of measurement and necessary conversions. This document also recommends instrumentation and estimations methods to monitor and report GHG emissions. Some emissions are measured and some are estimated. This document is applicable to the LNG industry. Applications include the provision of method to calculate GHG emissions through a standardized and auditable method, a means to determine their carbon footprint.
SIST EN ISO 6338:2026 is classified under the following ICS (International Classification for Standards) categories: 13.020.40 - Pollution, pollution control and conservation; 75.020 - Extraction and processing of petroleum and natural gas. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN ISO 6338:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 facility
- 3.2 global warming potential
- 3.3 greenhouse gas
- 3.4 organizational boundary
- 3.5 reporting boundary
- 3.6 scope 1
- 3.7 scope 2
- 3.8 scope 3
- 3.9 quality assurance
- 3.10 quality control
- 4 Principles
- 4.1 General
- 4.2 Relevance
- 4.3 Completeness
- 4.4 Consistency
- 4.5 Transparency
- 4.6 Accuracy
- 4.7 Conservativeness
- 5 GHG inventory boundaries
- 6 Quantification of GHG emissions
- 6.1 Identification of GHG sources and quantification approach
- 6.2 Calculation of GHG emissions
- 6.3 Preferred units
- 6.4 Allocation
- 6.5 Carbon capture
- 7 GHG inventory quality management
- 7.1 General
- 7.2 GHG Emission Calculation approach
- 7.3 Estimation of inventory uncertainties
- 7.4 Procedures for documentation and archiving
- 7.5 Quality Control
- 7.6 Quality Assurance
- 8 GHG reporting
- 8.1 General
- 8.2 Additional information
- 8.3 GHG emission reduction
- 8.4 Carbon offset and emission trading
- 9 Independent review
- Annex A
- 1 MJ/kg 429,9 BTU/lb
- 1 Mt/y LNG 141 Million std ft per day Based on LNG plant operating at 90 % availa-
- 55 MJ/kg
- Annex B
- Annex C
- 80 MW process heating 47 % 0,139 1 4 930 t/h CO2e per MW of power
- Bibliography
Introduction
Natural gas will play a key role in the energy transition (e.g. by replacing coal to produce electricity) and the use of LNG to transport natural gas is expected to increase. The process of liquefying natural gas is energy-intensive. Gas producers are increasingly accountable for their greenhouse gas (GHG) emissions and the ambition to reduce them. Furthermore, there is an emerging marketing demand for GHG data to enable commercial mechanisms such as offsetting to be utilized. There is no standardized and auditable methodology to calculate the carbon footprint of the whole LNG chain (including but not limited to the well, upstream treatment, transportation, liquefaction, shipping, regasification and end user distribution). Various standards indicate possible approaches but these are not consistent in their results or easily applicable.
SIST EN ISO 6338:2026 INTERNATIONAL STANDARD ISO 6338:2023(E) Method to calculate GHG emissions at LNG plant
1 Scope
This document provides a method to calculate the GHG emissions from an LNG liquefaction plant, onshore or offshore.
The frame of this document ranges from the inlet flange of the LNG plant’s inlet facilities up to and including the offloading arms to truck, ship or railcar loading. The upstream supply of gas up to the inlet flange of the inlet facilities and the distribution of LNG downstream of the loading arms are only covered in general terms.
This document covers:
- all facilities associated with producing LNG, including reception facilities, condensate unit (where applicable), pre-treatment units (including but not limited to acid gas removal, dehydration, mercury removal, heavies removal), LPG extraction and fractionation (where applicable), liquefaction, LNG storage and loading, Boil-Off-Gas handling, flare and disposal systems, imported electricity or onsite power generation and other plant utilities and infrastructure (e.g. marine and transportation facilities).
- natural gas liquefaction facilities associated with producing other products (e.g. domestic gas, condensate, LPG, sulphur, power export) to the extent required to allocate GHG emissions to the different products.
- all GHG emissions associated with producing LNG. These emissions spread across scope 1, scope 2 and scope 3 of the responsible organization. Scope 1, 2 and 3 are defined in this document. All emissions sources are covered including flaring, combustion, cold vents, process vents, fugitive leaks and emissions associated with imported energy.
The LNG plant is considered “under operation”, including emissions associated with initial start-up, maintenance, turnaround and restarts after maintenance or upset. The construction, commissioning, extension and decommissioning phases are excluded from this document but can be assessed separately. The emissions resulting from boil-off gas management during loading of the ship or any export vehicle are covered by this document. The emissions from a ship at berth, e.g. mast venting are not covered by this document.
This document describes the allocation of GHG emissions to LNG and other hydrocarbon products where other products are produced (e.g. LPG, domestic gas, condensates, sulphur, etc.). This document defines preferred units of measurement and necessary conversions. This document also recommends instrumentation and estimations methods to monitor and report GHG emissions. Some emissions are measured and some are estimated. This document is applicable to the LNG industry.
Applications include the provision of method to calculate GHG emissions through a standardized and auditable method, a means to determine their carbon footprint.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
SIST EN ISO 6338:2026 ISO 6338:2023(E) ISO 14044, Environmental management — Life cycle assessment — Requirements and guidelines ISO 14064-1, Greenhouse gases — Part 1: Specification with guidance at the organization level for quantification and reporting of greenhouse gas emissions and removals API Consistent Methodology for Estimating Greenhouse Gas Emissions from Liquefied Natural Gas (LNG) Operations
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 14064-1 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 facility
single installation, set of installations or production processes (stationary or mobile), which can be defined within a single geographical boundary, organizational unit or production process [SOURCE: ISO 14064-1:2018, 3.4.1]
3.2 global warming potential
GWP ratio of the time-integrated radiative forcing (warming effect) from the instantaneous release of 1 kg of the GHG relative to that from the release of 1 kg of CO2
3.3 greenhouse gas
GHG gaseous constituent of the atmosphere, both natural and anthropogenic, that absorbs and emits radiation at specific wavelengths within the spectrum of infrared radiation emitted by the Earth’s surface, the atmosphere and clouds Note 1 to entry: For a list of GHGs, see the 6th Intergovernmental Panel on Climate Change (IPCC) Assessment Report.
Note 2 to entry: Water vapour and ozone are anthropogenic as well as natural GHGs, but are not included as recognized GHGs due to difficulties, in most cases, in isolating the human-induced component of global warming attributable to their presence in the atmosphere.
[SOURCE: ISO 14064-1:2018, 3.1.1]
3.4 organizational boundary
grouping of activities or facilities in which an organization exercises operational or financial control or has an equity share [SOURCE: ISO 14064-1:2018, 3.4.7]
3.5 reporting boundary
grouping of greenhouse gas (GHG) emission or GHG removals reported from within the organizational boundary, as well as those significant indirect emissions that are a consequence of the organization’s operations and activities [SOURCE: ISO 14064-1:2018, 3.4.8]
SIST EN ISO 6338:2026 ISO 6338:2023(E)
3.6 scope 1
direct greenhouse gas emissions direct GHG emissions emissions coming from sources that are owned or controlled by the facility Note 1 to entry: This can be the emissions that are directly created by product fabrication or synthesis, for example, combustion fumes from a refinery.
3.7 scope 2
indirect greenhouse gas emissions from purchased and consumed energy indirect GHG emissions from purchased and consumed energy emissions from the generation of imported electricity, steam, and heating/cooling consumed by the facillity Note 1 to entry: These emissions physically occur at the facility where electricity, steam and cooling or heating are generated but as a user of the energy, the consuming party is still responsible for the greenhouse gas emissions that are being created.
3.8 scope 3
other indirect greenhouse gas emissions other indirect GHG emissions emissions from sources that are not owned and not directly controlled by the facility Note 1 to entry: However, they are related to the company’s activities. This is usually considered to be the supply chain of the company, so emissions caused by vendors within the supply chain, outsourced activities, and employee travel and commute. In many industries, other indirect GHG emissions account for the biggest amount of GHG emissions. This is due to the fact that in today’s economy, many tasks are outsourced and few companies own the entire value chain of their products.
3.9 quality assurance
QA planned system of review procedures conducted by personnel not directly involved in the inventory compilation/development process
3.10 quality control
QC planned system of review procedures conducted by personnel not directly involved in the inventory compilation/development process
4 Principles
4.1 General
The application of the following principles is fundamental to guarantee that GHG calculations are a true and fair account.
4.2 Relevance
Use data, methods, criteria, and assumptions that are appropriate for the intended use of reported information. The quantification and reporting of GHG emissions shall include only information that users — both internal and external to the plant — need for their decision-making. This information shall thus fit the intended purpose of the GHG project and meet the expectations or requirements of its users. Data, methods, criteria, and assumptions that are misleading or that do not conform to this document are not relevant and shall not be included.
SIST EN ISO 6338:2026 ISO 6338:2023(E)
4.3 Completeness
Consider all relevant information that can affect the accounting and quantification of GHG reductions, and complete all requirements. All relevant information shall be included in the quantification of GHG emissions. A GHG monitoring plan shall also specify how all data relevant to quantifying GHG reductions will be collected.
4.4 Consistency
Use data, methods, criteria, and assumptions that allow meaningful and valid comparisons. The credible quantification of GHG emissions requires that methods and procedures are always in the same manner, that the same criteria and assumptions are used to evaluate significance and relevance, and that any data collected and reported will be compatible enough to allow meaningful comparisons over time.
4.5 Transparency
Provide clear and sufficient information for reviewers to assess the credibility and reliability of GHG emissions claims. Transparency is critical for quantifying and reporting GHG reductions, particularly given the flexibility and policy-relevance of many GHG accounting. GHG information shall be compiled, analysed, and documented clearly and coherently so that reviewers can evaluate its credibility. Information relating to the GHG assessment boundary, the estimation of baseline emissions shall be sufficient to enable reviewers to understand how all conclusions were reached.
4.6 Accuracy
Uncertainties with respect to GHG measurements, estimates, or calculations shall be reduced as much as is practical, and measurement and estimation methods shall avoid bias. Acceptable levels of uncertainty will depend on the objectives for implementing a GHG project and the intended use of quantified GHG reductions. Where accuracy is sacrificed, data and estimates used to quantify GHG reductions shall be conservative.
4.7 Conservativeness
Where data and assumptions are uncertain and where the cost of measures to reduce uncertainty is not worth the increase in accuracy, make best endeavours to use the most probable data, with an analysis of the impact of likely uncertainty margins.
5 GHG inventory boundaries
The reporting boundaries of the GHG report for an onshore or offshore LNG liquefaction plant shall cover all facilities which are associated with the production of LNG. Table 1 provides examples of LNG plant facilities.
[1] Table 1 — List of LNG plant facilities Out of In scope of LNG Plant Facility scope of the report the report Natural Gas Production X Shipping / Pipeline Transport X Inlet gas Receiving Facilities X Condensate Unit (where applicable) X Pre-treatment Units (e.g. acid gas removal, dehydration, mercury removal, heavies X removal, others)
SIST EN ISO 6338:2026 ISO 6338:2023(E) TTabablele 1 1 ((ccoonnttiinnueuedd)) Out of In scope of LNG Plant Facility scope of the report the report LPG Extraction and Fractionation (where X applicable) Liquefaction Unit X LNG Storage and Loading X Flare and Disposal Systems X Carbon Capturing Unit X Utilities Supply (on-site power generation) X Utilities Supply (imported) X Plant Utilities and Infrastructure (e.g.
X plant piping and marine facilities) Regasification X The organization having financial and/or operational control over the LNG liquefaction plant shall report all GHG emissions and removals within the reporting boundaries at least on an annual average basis.
6 Quantification of GHG emissions
6.1 Identification of GHG sources and quantification approach
6.1.1 General
The main emission sources to consider derive from fuel combustion, flaring, releases to atmosphere (including fugitive emissions) and emissions associated with imported energy or consumables. Tables 2 to 5 give an initial checklist of emission sources to consider, and an overview of typical quantification methods suitable for different emission sources.
The chosen method of quantification per emissions source will differ from one LNG facility to another. Different plants will have access to a varying number of flow meters, composition analysis equipment and level meters available.
Operators shall develop a GHG quantification plan to map out how all emission sources can best be identified in the facility, with a preference to obtain primary data for all major emission sources. The measurement plan shall also include an assessment of data accuracy and impact on the total GHG emissions calculation. This assessment will then allow the operator to assess if there is a need to further improve the amount or accuracy of instruments available for the total assessment. Guidance on this assessment is detailed in ISO 14064-1:2018, Annex C.
A list of activity data shall be defined based on reliability as primary and secondary data:
- Primary data: quantified value of a process or an activity obtained from a direct measurement or a calculation based on direct measurements
- Secondary data: data obtained from sources other than primary data There is always a preference to use primary data. Only in the absence of primary data, secondary data may be used, that could include estimated quantities and industry average emission factors. Typically, primary data is recorded to enable GHG quantification contributing >5 % of the site’s total GHG emissions. For smaller individual sources a calculated approach is acceptable.
SIST EN ISO 6338:2026 ISO 6338:2023(E) The following subclauses describe sources to consider and typical quantification approach for the main emissions sources.
6.1.2 Emissions from fuel combustion
The quantification approaches for emissions from fuel combustion are described in Table 2. Table 2 — Emissions from fuel combustion at LNG liquefaction facilities Source Examples Quantification approach Gas turbine driv- Primary liquefaction drivers, power Typically, primary data is recorded to enable ers generation drivers, other refrigeration GHG quantification. As a minimum, fuel gas drivers (e.g. fractionation), CO sequestra- consumption and composition are required.
tion compressor drivers (Noting that fuel composition at an LNG plant can vary widely depending on operating mode) Diesel drivers Firewater pumps, power generation, boil- Operator may report typical annual diesel er feed water pumps consumption and include resulting annual emissions as a nominal allowance in the GHG calculation Boilers Steam for turbine drivers, steam for pro- Typically, primary data is recorded to enable cess heating GHG quantification for major fuel consumers (contributing >5 % of the total GHG emissions.) As a minimum, fuel gas consumption and composition shall be measured Fired heaters Regeneration gas heater, heating medium If fuel measurements are available, operator heater, direct fired reboilers should record total fuel gas consumption and composition. If direct fuel measurements are not available, a calculation based on operating duty and efficiency is acceptable Incinerators Acid gas vent incinerator, thermal oxidiz- As above ers, catalytic oxidizers, waste disposal Unburned hydrocarbons shall be taken into account in all sections. If fuel measurements are available, operator should record total fuel gas consumption combined with combustion efficiency data for the fired equipment used. Ideally, combustion efficiency should be validated with measured emission data.
6.1.3 Emissions from flaring and venting
The quantification approaches for emissions from flaring and venting are described in Table 3.
SIST EN ISO 6338:2026 ISO 6338:2023(E) Table 3 — Emissions from flaring and venting at LNG liquefaction facilities Source Examples Quantification approach Atmospheric Acid gas vent, sulphur plant tail gas Typically, primary data is recorded to enable waste disposal GHG quantification from venting contributfrom treating ing >5 % of the site’s total GHG emissions. For units smaller individual sources a calculated approach based on heat and material balance data is acceptable. As a minimum, fuel gas consumption and composition are required Atmospheric vent- Feed gas pipeline blowdown, storage tank Typically, primary data is recorded for signifing of unburned venting and pressure protection, loading icant venting events, such as pipeline blowhydrocarbon arm blowdown, compressor blowdown, down. A calculated approach is acceptable flare operation with failed ignition for venting events contributing <5 % of total annual emissions Flares Process plant pressure protection, depres- Typically, primary data is recorded to enable suring, storage tank pressure protection, GHG quantification from flaring contributing boil-off gas management, refrigerant com- >5 % of the site’s total GHG emissions. For position management, purge gas and pilots smaller individual sources a calculated approach is acceptable. Nitrogen vents Nitrogen vents from nitrogen rejection If primary data not available, a calculated from NRU units can contain methane, and are gener- allowance using licensor composition data may ally routed to atmosphere be used.
Unburned hydrocarbons shall be taken into account in all sections. Operator should record total flare gas, combined with combustion efficiency data for the flare tip used. Ideally, combustion efficiency should be validated with measured emission data.
6.1.4 Fugitive emissions
The quantification approaches for fugitive emissions are described in Table 4. Table 4 — Fugitive emissions at LNG liquefaction facilities Source Examples Quantification approach Permeation Emissions through porous materials Can be calculated with emissions factors for different materials.
Gas leaks Leaks from pipes and fittings, rotating Typically done via calculation using equipment equipment seals, storage tank seals count and standard leakage factors. Measured leakage data from atmospheric monitoring may be used to adjust the leakage factors applied.
6.1.5 Emissions associated with imported energy, utilities, and consumables
Emissions associated with imports require data from the exporter. Contractual relationship with the exporter should include a requirement to provide emissions data. In the absence of reliable GHG data for imports, the calculation shall account for the complete supply chain for the imported commodity. The cut-off criteria for reporting shall be defined in accordance with ISO 14044. The quantification approaches for emissions associated with imported energy, utilities and consumables are described in Table 5.
...