This European Standard specifies a set of assumptions, requirements and validation tests for procedures used for the calculation of the annual energy needs for space heating and cooling of a room in a building where the calculations are done with a time step of one hour or less.
This European Standard does not impose any specific numerical technique for the calculation of the room heating or cooling need and the internal temperatures of a room.
The purpose of this European Standard is to validate calculation methods used to:
-   assess the energy performance of each room of a building;
-   provide energy data to be used as interface with system performance analysis (heating, cooling, ventilating, lighting, domestic hot water etc).
The validation procedure is used to check the energy need for space heating and cooling based on a transient sensible heat balance model, taking into account:
-   the external surface heat balance;
-   the conduction through the building envelope;
-   the thermal capacities of external and internal structures;
-   the internal surface heat balance;
-   the air heat balance;
-   the heat balance solution method.
All other aspects are given either by prescribed boundary conditions or by input data and are not part of the model validation. It is assumed, that for all these other matters e.g. embedded heating and cooling systems, prescriptive models have to be used according to existing European Standards.
The system performance analysis and moisture balance are not within the scope of this European Standard.

  • Standard
    74 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a set of assumptions, requirements and validation tests for procedures used for the calculation of the annual energy needs for space heating and cooling of a room in a building where the calculations are done with a time step of one hour or less.
This European Standard does not impose any specific numerical technique for the calculation of the room heating or cooling need and the internal temperatures of a room.
The purpose of this European Standard is to validate calculation methods used to:
   assess the energy performance of each room of a building;
   provide energy data to be used as interface with system performance analysis (heating, cooling, ventilating, lighting, domestic hot water etc).
The validation procedure is used to check the energy need for space heating and cooling based on a transient sensible heat balance model, taking into account:
   the external surface heat balance;
   the conduction through the building envelope;
   the thermal capacities of external and internal structures;
   the internal surface heat balance;
   the air heat balance;
   the heat balance solution method.
All other aspects are given either by prescribed boundary conditions or by input data and are not part of the model validation. It is assumed, that for all these other matters e.g. embedded heating and cooling systems, prescriptive models have to be used according to existing European Standards.
The system performance analysis and moisture balance are not within the scope of this European Standard.

  • Standard
    74 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the requirements for buffers with 105 mm, 110 mm and 150 mm stroke for vehicles or units which use buffers and screw coupling at the coupling interface with other interoperable rolling stock. It covers the functionality, interfaces and testing procedures, including pass fail criteria, for buffers. It defines the different categories of buffers, the space envelope, static and dynamic characteristics and energy absorption. It includes a calculation method to determine the minimum size of the buffer head to avoid override between buffers. It defines the static and dynamic characteristics of the elastic systems. It also defines the requirements for buffers with integrated crash elements (crashworthy buffers) for tank wagons only according to RID. The requirements of this European Standard also apply to locomotives and passenger coaches which have to meet the crashworthiness requirements of EN 15227 for buffers in normal service only. The properties for the energy absorbing function are defined in EN 15227 and the requirements specified in Clause 7 for tank wagons according to RID are not applicable to locomotives and passenger coaches. Diagonal buffers are excluded from this European Standard. For vehicles which have to comply with crashworthiness requirements (locomotives, cab cars or passenger coaches according to EN 15227, tank wagons according to RID), typically crashworthy buffers (buffers with a deformable housing and/or the need for an opening in their mounting flange) or buffers which form part of a combined system consisting of a special buffer (e.g. middle flange buffer) and a deformation element are used. For these types of buffers, interoperability is possible, but interchangeability with freight wagon buffers is not required, and therefore the requirements of 5.2 (Fixing on vehicle and interchangeability), 5.3 (Buffer dimensions) do not apply, those of 5.4 (mechanical characteristics of buffers) and 5.6 (marking) apply with restrictions.

  • Standard
    72 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the requirements for buffers with 105 mm, 110 mm and 150 mm stroke for vehicles or units which use buffers and screw coupling at the coupling interface with other interoperable rolling stock. It covers the functionality, interfaces and testing procedures, including pass fail criteria, for buffers.
NOTE   Typically, buffers with a stroke of 105 mm are used on freight wagons and locomotives, buffers with a stroke of 110 mm are used on coaches and locomotives and buffers with a stroke of 150 mm are used on freight wagons.
It defines the different categories of buffers, the space envelope, static and dynamic characteristics and energy absorption.
It includes a calculation method to determine the minimum size of the buffer head to avoid override between buffers.
It defines the static and dynamic characteristics of the elastic systems.
It also defines the requirements for buffers with integrated crash elements (crashworthy buffers) for tank wagons only according to RID.
The requirements of this European Standard also apply to locomotives and passenger coaches which have to meet the crashworthiness requirements of EN 15227 for buffers in normal service only. The properties for the energy absorbing function are defined in EN 15227 and the requirements specified in Clause 7 for tank wagons according to RID are not applicable to locomotives and passenger coaches.
Diagonal buffers are excluded from this European Standard.
For vehicles which have to comply with crashworthiness requirements (locomotives, cab cars or passenger coaches according to EN 15227, tank wagons according to RID), typically crashworthy buffers (buffers with a deformable housing and/or the need for an opening in their mounting flange) or buffers which form part of a combined system consisting of a special buffer (e.g. middle flange buffer) and a deformation element are used.

  • Standard
    72 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the terms, definitions, test conditions, test methods and requirements for rating the performance of air conditioners and liquid chilling packages, with electrically driven compressors and with evaporatively cooled condenser when used for space cooling. The evaporatively cooled condenser is cooled by air and by the evaporation of external additional water. This additional external water is fed by a specific water supply circuit or by a water tank.
This standard does not apply to air-to-air and air-to-water air conditioners with a condenser cooled by air and by the evaporation of water condensed on their evaporator.
This standard does not apply to units equipped with a water tank or with a continuous water circuit supply that cannot operate without water feeding.
This standard applies to factory-made units which can be ducted.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard.
With regard to units consisting of several parts, this standard applies only to those designed and supplied as a complete package.
Installations used for industrial processes cooling are not within the scope of this standard.
NOTE   All the symbols given in this text should be used regardless of language.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document establishes requirements for determining, in accordance with a standardized procedure, the sound power level emitted into the surrounding air by air-conditioners, heat-pumps, liquid chilling packages with electrically driven compressors when used for space heating and/or cooling, as described by the standards EN 14511 and dehumidifiers as described by the standard EN 810.
It is emphasized that this measurement standard only refers to airborne noise.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
It covers:
- packaged units, single split and multisplit systems, except water cooled multisplit systems,
- air-to-air air conditioners which evaporate the condensate on the condenser side,
- chillers, shelters, roof-tops.
- inverters.
In the case of units consisting of several parts, this standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard does not cover:
- units having their condenser cooled by air and by the evaporation of external additional water,
- heat pumps for sanitary hot water, although some definitions can be applied to these units,
- units using transcritical cycles, e.g. with CO2 as refrigerant,
- installations used for heating and/or cooling of industrial processes.
This standard offers ways to determine the sound power level of units. Some of them are specifically adapted to provide results with low uncertainties, by using laboratory class acoustic methods and highly controlled working conditions. Those measurements are suitable for certification, labelling and marking purposes.
In some cases, the target and/or the environment of the measurements do not allow such precision-class results. This standard also offers ways to assess sound power levels with acceptable accuracy even though acoustic methods and/or working conditions are not laboratory-type, e.g. in situ or quality control measurements. This European Standard gives two classes of measurements and results, according to the test environment:;Class A measurements correspond to controlled working conditions (standard or application rating conditions). It is defined by the respect to the tolerances of Table 2.;Class B measurements correspond to the case where the range defined by the tolerances of Table 2 cannot be fulfilled. In both classes, precision or engineering class acoustic methods should be applied. The choice of the acoustic measurement method is done in accordance with EN ISO 3740 and EN ISO 9614 depending on the type of surrounding acoustic fields (diffuse or free field, enclosed or open space), and the available instrumentation. Whatever the current working conditions, the reference of acoustic standard shall be reported, with explicit mention of its accuracy class.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 The scope of prEN 14511-2:2009 is applicable.
1.2 This part of prEN 14511 specifies the test methods for the rating and performance of air and watercooled
air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat
pumps with electrically driven compressors when used for space heating and cooling.
It also specifies the method of testing and reporting for heat recovery capacities, system reduced capacities and
the capacity of individual indoor units of multisplit systems, where applicable.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 The scope of prEN 14511-2:2009 is applicable.
1.2 This part of EN 14511 specifies minimum requirements which ensure that air conditioners, heat pumps
and liquid chilling packages with electrical driven compressors are fit for the use designated by the
manufacturer when used for space heating and/or cooling.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 The scope of prEN 14511-2:2009 is applicable.
1.2 This part of prEN 14511 specifies the test conditions for the rating of air and water cooled air
conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with
electrically driven compressors when used for space heating and/or cooling. It also specifies test conditions
for heat recovery operation of multisplit systems.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies the terms and definitions for the rating and performance of air and water cooled
air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with
electrically driven compressors when used for space heating and/or cooling. This European Standard does not
specifically apply to heat pumps for sanitary hot water, although certain definitions can be applied to these.
This European Standard applies to.
 factory-made units that can be ducted,
 factory-made liquid chilling packages with integral condensers or for use with remote condensers,
 factory-made units of either fixed capacity or variable capacity by any means, and
 air-to-air air conditioners which evaporate the condensate on the condenser side.
Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units
are covered by the standard.
In the case of units consisting of several parts, this document applies only to those designed and supplied as a
complete package, except for liquid chilling packages with remote condenser.
This document is primarily intended for water and brine chilling packages but can be used for other liquid subject
to agreement.
The units having their condenser cooled by air and by the evaporation of external additional water are not
covered by this standard, but by EN 15218 related to evaporatively-cooled condenser units.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE 1 Part load testing of units is dealt with in CEN/TS 14825.
NOTE 2 All the symbols given in this text should be used regardless of the language used.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the terms and definitions for the rating and performance of air conditioners, liquid chilling packages and heat pumps using either, air, water or brine as heat transfer media, with electrically driven compressors when used for space heating and/or cooling. This European Standard does not apply to heat pumps for domestic hot water, although certain definitions can be applied to these.
This European Standard applies to:
- factory-made units that can be ducted,
- factory-made liquid chilling packages with integral condensers or for use with remote condensers,
- factory-made units of either fixed capacity or variable capacity by any means, and
- air-to-air air conditioners which can also evaporate the condensate on the condenser side.
Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units are covered by the standard.
In the case of units consisting of several parts, this European Standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This European Standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard, see EN 15218 for evaporatively cooled condenser units.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE 1   Part load testing of units is dealt with in prEN 14825.
NOTE 2   All the symbols given in this text should be used regardless of the language used.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   The scope of EN 14511-1:2011 is applicable.
1.2   This European Standard specifies minimum requirements which ensure that air conditioners, heat pumps and liquid chilling packages using either air, water or brine as heat transfer media, with electrical driven compressors are fit for the use designated by the manufacturer when used for space heating and/or cooling.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   The scope of EN 14511-1:2011 is applicable.
1.2   This European Standard specifies the test conditions for the rating of air conditioners, liquid chilling packages and heat pumps, using either, air, water or brine as heat transfer media, with electrically driven compressors when used for space heating and/or cooling. It also specifies test conditions for heat recovery operation of multisplit systems.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   The scope of EN 14511-1:2011 is applicable.
1.2   This European Standard specifies the test methods for the rating and performance of air conditioners, liquid chilling packages and heat pumps using either air, water or brine as heat transfer media, with electrically driven compressors when used for space heating and cooling.
It also specifies the method of testing and reporting for heat recovery capacities, system reduced capacities and the capacity of individual indoor units of multisplit systems, where applicable.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard establishes requirements for determining, in accordance with a standardized procedure, the sound power level emitted into the surrounding air by air conditioners, heat pumps, liquid chilling packages with electrically driven compressors when used for space heating and/or cooling, including water cooled multisplit systems, as described in EN 14511 and dehumidifiers as described in EN 810.
It is emphasized that this measurement standard only refers to airborne noise.
This European Standard offers ways to determine the sound power level of units. Some of them are specifically adapted to provide results with low uncertainties, by using laboratory class acoustic methods and highly controlled working conditions. Those measurements are suitable for certification, labelling and marking purposes.
In some cases, the target and/or the environment of the measurements do not allow such precision-class methods. This European Standard also offers ways to assess sound power levels with acceptable accuracy even though acoustic methods and/or working conditions are not laboratory-type, e.g. in situ or quality control measurements.
This European Standard gives two classes of measurements and results, according to the test environment:
- Class A measurements correspond to controlled working conditions (standard or application rating conditions). It is defined by the respect to the tolerances of Table 2.
- Class B measurements correspond to the case where the range defined by the tolerances of Table 2 cannot be fulfilled.
In both classes, precision or engineering class acoustic methods should be applied. The choice of the acoustic measurement method is done in accordance with EN ISO 3740 and EN ISO 9614 depending on the type of surrounding acoustic fields (diffuse or free field, enclosed or open space), and the available instrumentation. Whatever the current working conditions, the reference of acoustic standard shall be reported, with explicit mention

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the terms, definitions, test conditions, test methods and requirements for rating the performance of air conditioners and liquid chilling packages, with electrically driven compressors and with evaporatively cooled condenser when used for space cooling. The evaporatively cooled condenser is cooled by air and by the evaporation of external additional water. This additional external water is fed by a specific water supply circuit or by a water tank.
This standard does not apply to air-to-air and air-to-water air conditioners with a condenser cooled by air and by the evaporation of water condensed on their evaporator.
This standard does not apply to units equipped with a water tank or with a continuous water circuit supply that cannot operate without water feeding.
This standard applies to factory-made units which can be ducted.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard.
With regard to units consisting of several parts, this standard applies only to those designed and supplied as a complete package.
Installations used for industrial processes cooling are not within the scope of this standard.
NOTE   All the symbols given in this text should be used regardless of language.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies checks, test methods and measuring instruments in order to verify the fitness for purpose of the installed systems at the stage of handing over. The Standard enables the choice between simple test methods, when sufficient, and extensive measurements, when necessary. The Standard applies to mechanically operated ventilation and air conditioning systems as specified in CR 12792 and comprising any of the following: - air terminal devices and units; - air handling units; - air distribution systems (supply, extract, exhaust); - fire protection devices; - automatic control devices.

  • Standard
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies checks, test methods and measuring instruments in order to verify the fitness for purpose of the installed systems at the stage of handing over. The Standard enables the choice between simple test methods, when sufficient, and extensive measurements, when necessary. The Standard applies to mechanically operated ventilation and air conditioning systems as specified in CR 12792 and comprising any of the following: - air terminal devices and units; - air handling units; - air distribution systems (supply, extract, exhaust); - fire protection devices; - automatic control devices.

  • Standard
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 255 specifies methods for testing and reporting of the rating and it specifies requirements for marking of air/water and water/water heat pumps with electrically driven compressors when used for sanitary hot water. When these units are used for space heating, then prEN 255-2 applies. This standard applies to factory-made units which can be ducted. In the case of unitsconsisting of several parts, the standard applies only to those designed and supplied as a complete package.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the terms, definitions, rating conditions and requirements of variable capacity air conditioners and heat pumps with electrically driven compressors.

  • Technical specification
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the terms, definitions, rating conditions and requirements of variable capacity air conditioners and heat pumps with electrically driven compressors.

  • Technical specification
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies the test methods for the rating and performance of air and water-cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and cooling.
It also specifies the method of testing and reporting for heat recovery capacities, system reduced capacities and the capacity of individual indoor units of multisplit systems, where applicable.
This European Standard applies to factory made units that can be ducted.
This standard applies to factory made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units are covered by the standard.
In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE 1   Part load testing of units is dealt with in CEN/TS 14825.
NOTE 2   All the symbols given in this text should be used regardless of the language used.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies minimum requirements which ensure that air conditioners, heat pumps and liquid chilling packages with electrical driven compressors are fit for the use designated by the manufacturer when used for space heating and/or cooling.
This European Standard applies to factory made units that can be ducted.
This standard applies to factory made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units are covered by the standard.
In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for cooling any other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE   Part load testing of units is dealt with in CEN/TS 14825.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies the test conditions for the rating of air and water cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and/or cooling. It also specifies test conditions for heat recovery operation of multisplit systems.
This European Standard applies to factory made units that can be ducted.
This standard applies to factory made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units are covered by the standard.
In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE   Part load testing of units is dealt with in CEN/TS 14825.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies the terms and definitions for the rating and performance of air and water cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and/or cooling. This European Standard does not specifically apply to heat pumps for sanitary hot water, although certain definitions can be applied to these.
This European Standard applies to factory made units that can be ducted.
This standard applies to factory made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard.,Single duct and double duct units are covered by the standard.
In the case of units consisting of several parts, this standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE 1   Part load testing of units is dealt with in CEN/TS 14825.
NOTE 2   All the symbols given in this text should be used regardless of the language used.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies the test methods for the rating and performance of air and water-cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and cooling.
It also specifies the method of testing and reporting for heat recovery capacities, system reduced capacities and the capacity of individual indoor units of multisplit systems, where applicable.
This European Standard applies to factory made units that can be ducted.
This standard applies to factory made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units are covered by the standard.
In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE 1   Part load testing of units is dealt with in CEN/TS 14825.
NOTE 2   All the symbols given in this text should be used regardless of the language used.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies the terms and definitions for the rating and performance of air and water cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and/or cooling. This European Standard does not specifically apply to heat pumps for sanitary hot water, although certain definitions can be applied to these.
This European Standard applies to factory made units that can be ducted.
This standard applies to factory made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units are covered by the standard.
In the case of units consisting of several parts, this standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE 1   Part load testing of units is dealt with in CEN/TS 14825.
NOTE 2   All the symbols given in this text should be used regardless of the language used.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies the test conditions for the rating of air and water cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and/or cooling. It also specifies test conditions for heat recovery operation of multisplit systems.
This European Standard applies to factory made units that can be ducted.
This standard applies to factory made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units are covered by the standard.
In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE   Part load testing of units is dealt with in CEN/TS 14825.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies minimum requirements which ensure that air conditioners, heat pumps and liquid chilling packages with electrical driven compressors are fit for the use designated by the manufacturer when used for space heating and/or cooling.
This European Standard applies to factory made units that can be ducted.
This standard applies to factory made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units are covered by the standard.
In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for cooling any other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE   Part load testing of units is dealt with in CEN/TS 14825.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 255 specifies methods for testing and reporting of the rating and it specifies requirements for marking of air/water and water/water heat pumps with electrically driven compressors when used for sanitary hot water. When these units are used for space heating, then prEN 255-2 applies. This standard applies to factory-made units which can be ducted. In the case of unitsconsisting of several parts, the standard applies only to those designed and supplied as a complete package.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the terms and definitions for the rating and performance of air and water cooled air conditioners, air/air and water/air heatpumps with electrically driven compressors as well as the properties of the units when used in cooling mode. When these units are used in heating mode by reversing the refrigerating cycle, then prEN 255-1 applies. This standard applies to factory-made units which can be ducted.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 814 specifies minimum requirements which ensure that an air or water cooled air conditioner, air/air or water/air heat pump, with electrically driven compressor, is fitted for the use designated by the manufacturer, when used in cooling mode. When these units are used in heating mode by reversing the refrigerating cycle, then prEN 255-4 applies. This standard also specifies recommendations for the way the characteristics of units shall be specified by the manufacturer in order to assist users and manufacturers in the understandingand comparison of various types.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 814 specifies methods for testing and reporting of the rating and specifies requirements for marking of air and water cooled air conditioners,air/air and water/air heat pumps with electrically driven compressors when used in cooling mode. When these units are used in heating mode by reversing the refrigerating cycle, then prEN 255-2 applies. This standard applies to factory- made units which can be ducted.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies methods for testing and reporting of the rating and operational requirements and it specifies requirements for marking of liquid chilling packages, water/water and air/water heat pumps with electrically driven compressors when used for cooling or for cooling and heat recovery. When these units are used for heating, then Parts 1 to 4 of EN 255 apply.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 255 specifies the terms and definitions for the rating and performance of air and water cooled air conditioners, liquid chilling packages, air/air, air/water and water/water heat pumps with electrically driven compressors as well as the properties of the units when used in heating mode. When these units are used for space cooling, then prEN 814-1 applies; when these units are used for cooling and heat recovery, then prEN 12055 applies. This standard does not specifically apply to heat pumps for sanitary hot water, although certain definitions can be applied to these.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 255 specifies minimum requirements which ensure that an air or water cooled air conditioner, liquid chilling packages, air/air, water/air or water/water heat pump, with electrically driven compressor, is fitted for theuse designated by the manufacturer, when used for space heating or for hot sanitary water. When these units are used for space cooling, then prEN 814-3 applies; when these units are used for cooling and heat recovery, then prEN 12055 applies.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 255 specifies methods for testing and reporting of the rating and it specifies requirements for marking of air and water cooled air conditioners, liquid chilling packages, air/air, water/air, air/water and water/water heat pumps with electrically driven compressors when used for space heating. When these units are used for space cooling, then prEN 814-2 applies; when these units are used for cooling and heat recovery, then prEN 12055 applies; when they are used for sanitary hot water, then prEN 255-3 applies.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard establishes requirements for determining, in accordance with a standardized procedure, the noise (parameter: sound power level) emitted into the surrounding air by air conditioners, heat pumps or dehumidifiers with electrically-driven compressors. The frequency range used in this pre-standard is from 125 Hz to 4000 Hz. Three methods for determining the sound power levels are specified in order to avoid unduly restricting existing facilities and experience.

  • Standardization document
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard establishes requirements for determining, in accordance with a standardized procedure, the noise (parameter: sound power level) emitted into the surrounding air by air conditioners, heat pumps or dehumidifiers with electrically-driven compressors. The frequency range used in this pre-standard is from 125 Hz to 4000 Hz. Three methods for determining the sound power levels are specified in order to avoid unduly restricting existing facilities and experience.

  • Standardization document
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies minimum requirements which ensure that air conditioners, heat pumps and liquid chilling packages with electrical driven compressor, are fit for the use designated by the manufacturer when used for space heating and/or cooling.
This European Standard applies to factory-made units that can be ducted.
This standard applies to factory-made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard, except water cooled multisplit systems.
In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for cooling any other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE   Part load testing of units is dealt with in CEN/TS 14825.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies the test conditions for the rating of air and water cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and/or cooling. It also specifies test conditions for heat recovery operation of multisplit systems.
This European Standard applies to factory-made units that can be ducted.
This standard applies to factory-made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard, except water cooled multisplit systems.
In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE   Part load testing of units is dealt with in CEN/TS 14825.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies the test methods for the rating and performance of air and water-cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and cooling.
It also specifies the method of testing and reporting for heat recovery capacities, system reduced capacities and the capacity of individual indoor units of multisplit systems, where applicable.
This European Standard applies to factory-made units that can be ducted.
This standard applies to factory-made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard, except water-cooled multisplit systems.
In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE 1   Part load testing of units is dealt with in CEN/TS 14825.
NOTE 2   All the symbols given in this text should be used regardless of the language used.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies the terms and definitions for the rating and performance of air and water cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and/or cooling. This European Standard does not specifically apply to heat pumps for sanitary hot water, although certain definitions can be applied to these.
This European Standard applies to factory-made units that can be ducted.
This standard applies to factory-made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard, except water cooled multisplit systems.
In the case of units consisting of several parts, this standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE 1   Part load testing of units is dealt with in CEN/TS 14825.
NOTE 2   All the symbols given in this text should be used regardless of the language used.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies the terms and definitions for the rating and performance of air and water cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and/or cooling. This European Standard does not specifically apply to heat pumps for sanitary hot water, although certain definitions can be applied to these.
This European Standard applies to factory-made units that can be ducted.
This standard applies to factory-made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard, except water cooled multisplit systems.
In the case of units consisting of several parts, this standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE 1   Part load testing of units is dealt with in CEN/TS 14825.
NOTE 2   All the symbols given in this text should be used regardless of the language used.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies the test conditions for the rating of air and water cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and/or cooling. It also specifies test conditions for heat recovery operation of multisplit systems.
This European Standard applies to factory-made units that can be ducted.
This standard applies to factory-made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard, except water cooled multisplit systems.
In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE   Part load testing of units is dealt with in CEN/TS 14825.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 14511 specifies the test methods for the rating and performance of air and water-cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and cooling.
It also specifies the method of testing and reporting for heat recovery capacities, system reduced capacities and the capacity of individual indoor units of multisplit systems, where applicable.
This European Standard applies to factory-made units that can be ducted.
This standard applies to factory-made liquid chilling packages with integral condensers or for use with remote condensers.
This standard applies to factory-made units of either fixed capacity or variable capacity by any means.
Packaged units, single split and multisplit systems are covered by this standard, except water-cooled multisplit systems.
In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard.
This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE 1   Part load testing of units is dealt with in CEN/TS 14825.
NOTE 2   All the symbols given in this text should be used regardless of the language used.