Standard Specification for Shelter, Electrical Equipment, Lightweight

ABSTRACT
This specification covers two types of lightweight electrical equipment shelters designed for transport on both the M1037 and M1097 high mobility multipurpose wheeled vehicle (HMMWV) by rail, air, marine, and highway when mounted or dismounted from their vehicles. The shelters will be of the following types: Type I —shelters without tunnel(17-2-0035-1); and Type III —modified general-purpose shelters with tunnel (17-2-0035-3). Shelters shall undergo rigid verification procedures to inspect their conformance to requirements pertaining to physical performance, environmental performance, transportability performance, identification, toxicity, and flame resistance.
SCOPE
1.1 This specification covers two types of lightweight electrical equipment shelters designed for transport on the M1152A1 and the M1152A1 with B2 Armor Kit High Mobility Multipurpose Wheeled Vehicle (HMMWV). These shelters are transported by rail, air, marine and highway when mounted or dismounted from their vehicles.  
1.2 Classification—The shelters will be of the following types, as specified (see 6.2).  
1.2.1 Type I—Shelter, Electrical Equipment, Lightweight (w/o Tunnel, 17-2-0035-1).  
1.2.2 Type III—Shelter, Electrical Equipment, Lightweight, Modified, General Purpose (w/ Tunnel, 17-2-0035-3).  
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.4 The following safety hazards caveat pertains only to the test required portion, Section 4, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory requirements prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Aug-2018
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM E2377-18 - Standard Specification for Shelter, Electrical Equipment, Lightweight
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM E2377-18 - Standard Specification for Shelter, Electrical Equipment, Lightweight
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:E2377 −18
Standard Specification for
1
Shelter, Electrical Equipment, Lightweight
This standard is issued under the fixed designation E2377; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope E1851Test Method for Electromagnetic Shielding Effec-
tiveness of Durable Rigid Wall Relocatable Structures
1.1 This specification covers two types of lightweight elec-
E1925Specification for Engineering and Design Criteria for
trical equipment shelters designed for transport on the
Rigid Wall Relocatable Structures
M1152A1andtheM1152A1withB2ArmorKitHighMobility
3
2.2 Commercial Standard:
MultipurposeWheeledVehicle (HMMWV).These shelters are
SAE-AS8090Equipment,TowedAerospaceGround,Mobil-
transported by rail, air, marine and highway when mounted or
ity
dismounted from their vehicles.
4
2.3 Federal Standard:
1.2 Classification—The shelters will be of the following
FED-STD-595Colors Used in Government Procurement
types, as specified (see 6.2).
4
2.4 Military Standards:
1.2.1 Type I—Shelter, Electrical Equipment, Lightweight
MIL-STD-209Slinging and Tiedown Provisions for Lifting
(w/o Tunnel, 17-2-0035-1).
and Tying Down Military Equipment
1.2.2 Type III—Shelter, Electrical Equipment, Lightweight,
MIL-STD-810GEnvironmentalTestMethodsandEngineer-
Modified, General Purpose (w/ Tunnel, 17-2-0035-3).
ing Guidelines
1.3 The values stated in inch-pound units are to be regarded
MIL-STD-1366Transportability Criteria
as standard. The values given in parentheses are mathematical
MIL-C-53072Chemical Agent Resistant Coating (CARC)
conversions to SI units that are provided for information only
System Application Procedures and Quality Control In-
and are not considered standard.
spection
4
2.5 Military Handbook:
1.4 The following safety hazards caveat pertains only to the
MIL-HDBK-1791Designing for InternalAerial Delivery in
test required portion, Section 4, of this specification: This
Fixed Winged Aircraft
standard does not purport to address all of the safety concerns,
5
if any, associated with its use. It is the responsibility of the user 2.6 ACGIH Documents:
of this standard to establish appropriate safety, health, and ThresholdLimitValues
6
environmental practices and determine the applicability of
2.7 Drawings:
regulatory requirements prior to use.
17-1-8565Extension Kit, Pintle
1.5 This international standard was developed in accor-
17-1-8584Mounting Kit Shelter To HMMWV(For Refer-
dance with internationally recognized principles on standard-
ence Only)
ization established in the Decision on Principles for the
17-2-0035Interface Control Drawing for, Shelter, Electrical
Development of International Standards, Guides and Recom-
Equipment, Lightweight, Types I and III
mendations issued by the World Trade Organization Technical
13228E1639 Standard Camouflage, Pattern For Shelter,
Barriers to Trade (TBT) Committee.
Lightweight, Multipurpose
2. Referenced Documents 3. General Requirements
2
2.1 ASTM Standards: 3.1 First Article—When specified (see 6.3), a sample shall
besubjectedtofirstarticleinspectioninaccordancewith4.1.1.
1
This specification is under the jurisdiction of ASTM Committee E06 on
3
Performance of Buildings and is the direct responsibility of Subcommittee E06.53 AvailablefromSAEInternational(SAE),400CommonwealthDr.,Warrendale,
on Materials and Processes for Durable Rigidwall Relocatable Structures. PA 15096, http://www.sae.org.
4
Current edition approved Sept. 1, 2018. Published September 2018. Originally Available from DLA Document Services, Building 4/D, 700 Robbins Ave.,
approved in 2003 as PS 138–03. Last previous edition approved in 2010 as Philadelphia, PA 19111-5094, http://quicksearch.dla.mil.
5
E2377–10. DOI: 10.1520/E2377–18. Available from American Conference of Governmental Industrial Hygienists
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or (ACGIH),1330KemperMeadowDr.,Cincinnati,OH45240,http://www.acgih.org.
6
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Available from U.S. Army Natick Soldier Research, Development, and Engi-
Standards volume information, refer to the standard’s Document Summary page on neering Center, ATTN: RDNS-SEE-T, 15 General Greene Avenue, Natick, MA
the ASTM website. 01760-5018, https://www.army.mil/info/organization/natick.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

-----------------
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E2377 − 10 E2377 − 18
Standard Specification for
1
Shelter, Electrical Equipment, Lightweight
This standard is issued under the fixed designation E2377; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers two types of lightweight electrical equipment shelters designed for transport on the M1152A1,
M1152A1 M1152A1 and the M1152A1 with B2 Armor Kit, M1037, and M1097 Kit High Mobility Multipurpose Wheeled Vehicle
(HMMWV). These shelters are transported by rail, air, marine and highway when mounted or dismounted from their vehicles.
1.2 Classification—The shelters will be of the following types, as specified (see 6.2).
1.2.1 Type I—Shelter, Electrical Equipment, Lightweight (w/o Tunnel, 17-2-0035-1).
1.2.2 Type III—Shelter, Electrical Equipment, Lightweight, Modified, General Purpose (w/ Tunnel, 17-2-0035-3).
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.4 The following safety hazards caveat pertains only to the test required portion, Section 4, of this specification: This standard
does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this
standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the applicability of
regulatory requirements prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
E1851 Test Method for Electromagnetic Shielding Effectiveness of Durable Rigid Wall Relocatable Structures
E1925 Specification for Engineering and Design Criteria for Rigid Wall Relocatable Structures
3
2.2 Commercial Standard:
SAE-AS8090 Equipment, Towed Aerospace Ground, Mobility
4
2.3 Federal Standard:
FED-STD-595 Colors Used in Government Procurement
4
2.4 Military Standards:
MIL-STD-209 Slinging and Tiedown Provisions for Lifting and Tying Down Military Equipment
MIL-STD-810MIL-STD-810G Environmental Test Methods and Engineering Guidelines
MIL-STD-1366 Transportability Criteria
MIL-C-53072 Chemical Agent Resistant Coating (CARC) System Application Procedures and Quality Control Inspection
4
2.5 Military Handbook:
MIL-HDBK-1791 Designing for Internal Aerial Delivery in Fixed Winged Aircraft
5
2.6 ACGIH Documents:
Threshold Limit Values
1
This specification is under the jurisdiction of ASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.53 on Materials
and Processes for Durable Rigidwall Relocatable Structures.
Current edition approved Oct. 1, 2010Sept. 1, 2018. Published October 2010September 2018. Originally approved in 2003 as PS 138 - 03.138–03. Last previous edition
approved in 20042010 as E2377 – 04.E2377–10. DOI: 10.1520/E2377-10.10.1520/E2377–18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’sstandard’s Document Summary page on the ASTM website.
3
Available from SAE International (SAE), 400 Commonwealth Dr., Warrendale, PA 15096-0001,15096, http://www.sae.org.
4
Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, DLA Document Services, Building 4/D, 700 Robbins Ave., Philadelphia, PA
19111-5098, http://dodssp.daps.dla.mil.19111-5094, http://quicksearch.dla.mil.
5
Available from American Conference of Governmental Industrial Hygienists, Inc. Hygienists (ACGIH), 1330 Kemper Meadow Dr., Cincinnati, OH 45240,
http://www.acgih.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E2377 − 18
TABLE 1 Weight and Payload Capacity
Maximum Minimum Mounting
Pintle Extension
Type Shelter Payload Kit Incl.
Incl. Hardware
Weight Capacity
...

Questions, Comments and Discussion