Standard Test Method for Marsh Funnel Viscosity of Construction Slurries

SIGNIFICANCE AND USE
5.1 Viscosity is a fundamental characteristic for slurries in construction applications. The Marsh Funnel Viscosity test can be used for field quality control of slurries. Relative changes in slurry viscosity can be identified using Marsh Funnel measurements and modifications can be made to mixing and handling procedures.
Note 1: The development of the Marsh Funnel is credited to Hallan N. Marsh of Los Angeles who published the design and use of his funnel viscometer in 1931.  
5.2 This test method allows for the assessment of the apparent viscosity of construction slurries in the laboratory and in the field. The Marsh Funnel Viscosity is not a true viscosity, it is an index value and can only be used to assess the relative viscosity of the slurry to water. Higher MFV values are obtained for slurries with higher viscosity and lower MFV values are obtained for slurries with lower viscosity.  
5.3 In this test, it is assumed that the apparent viscosity of a slurry is directly related to the flow duration through a specially shaped funnel (the Marsh Funnel).  
5.4 In slurry construction applications, the viscosity of a slurry must be maintained within a predetermined range to stabilize the surrounding soil being supported.  
5.5 The Marsh Funnel Viscosity has been widely used in drilling soil and rock for water wells and oil, gas, soil stabilization, foundation drilling, and hydraulic barrier applications.  
5.6 Inert suspended solids (such as fine sands, clays, and cement) and additives affect the viscosity of slurries. This test may be used to determine the relative effects of these and other such materials on the viscosity of a slurry.
Note 2: The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing, sampling/inspection/etc. Us...
SCOPE
1.1 This test method provides an indirect measurement of the viscosity of construction slurries using a funnel (Marsh Funnel) and a graduated cup with specific volume marks. This test method provides an indicator of the viscosity on a routine basis. This test method has been modified from the API Recommended Practice 13B-1.  
1.2 The result determined using the method is referred to as the Marsh Funnel Viscosity. The Marsh Funnel Viscosity is an index property and is not an actual measurement of viscosity.  
1.3 This test can be performed in the laboratory or in the field to assess the Marsh Funnel Viscosity of a slurry for quality control purposes.  
1.4 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
14-May-2019
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D6910/D6910M-19 - Standard Test Method for Marsh Funnel Viscosity of Construction Slurries
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D6910/D6910M − 19
Standard Test Method for
1
Marsh Funnel Viscosity of Construction Slurries
This standard is issued under the fixed designation D6910/D6910M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* D653 Terminology Relating to Soil, Rock, and Contained
Fluids
1.1 This test method provides an indirect measurement of
D3740 Practice for Minimum Requirements for Agencies
the viscosity of construction slurries using a funnel (Marsh
Engaged in Testing and/or Inspection of Soil and Rock as
Funnel) and a graduated cup with specific volume marks. This
Used in Engineering Design and Construction
test method provides an indicator of the viscosity on a routine
2.2 API Document:
basis. This test method has been modified from the API
API RP 13B-1 (R2016), Recommended Practice for Field
Recommended Practice 13B-1.
TestingWater-based Drilling Fluids, Fourth Edition (Iden-
1.2 The result determined using the method is referred to as 3
tical to ISO 10414-1:2008)
the Marsh Funnel Viscosity. The Marsh Funnel Viscosity is an
index property and is not an actual measurement of viscosity.
3. Terminology
1.3 This test can be performed in the laboratory or in the
3.1 Definitions—For common definitions of technical terms
field to assess the Marsh Funnel Viscosity of a slurry for
in this standard, refer to Terminology D653.
quality control purposes.
3.2 Definitions of Terms Specific to This Standard:
1.4 Units—The values stated in either SI units or inch-
3.2.1 Marsh Funnel Viscosity (MFV)—also known as funnel
pound units are to be regarded separately as standard. The
viscosity. The time required (in seconds) for 1 qt [1 L] of a
values stated in each system may not be exact equivalents;
slurry to flow into a graduated cup from a funnel (known as a
therefore,eachsystemshallbeusedindependentlyoftheother.
Marsh Funnel) with specific dimensions.
Combining values from the two systems may result in noncon-
4. Summary of Test Method
formance with the standard.
4.1 In this method, a slurry is poured into a funnel with
1.5 This standard does not purport to address all of the
specific dimensions (Marsh Funnel).The slurry is then allowed
safety concerns, if any, associated with its use. It is the
to flow into a graduated cup. The time for the slurry to fill a
responsibility of the user of this standard to establish appro-
priate safety, health, and environmental practices and deter- volume of 1 qt [1 L] is measured and reported as the Marsh
Funnel Viscosity. The test temperature is also reported for
mine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accor- comparison purposes.
dance with internationally recognized principles on standard-
5. Significance and Use
ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom- 5.1 Viscosity is a fundamental characteristic for slurries in
mendations issued by the World Trade Organization Technical
construction applications. The Marsh Funnel Viscosity test can
Barriers to Trade (TBT) Committee. be used for field quality control of slurries. Relative changes in
slurry viscosity can be identified using Marsh Funnel measure-
2. Referenced Documents
ments and modifications can be made to mixing and handling
2
2.1 ASTM Standards: procedures.
NOTE 1—The development of the Marsh Funnel is credited to Hallan N.
Marsh of Los Angeles who published the design and use of his funnel
1
This test method is under the jurisdiction ofASTM Committee D18 on Soil and
viscometer in 1931.
Rock and is the direct responsibility of Subcommittee D18.16 on Grouting.
Current edition approved May 15, 2019. Published June 2019. Originally
5.2 This test method allows for the assessment of the
approved in 2004. Last previous edition approved in 2009 as D6910/D6910M – 09,
apparent viscosity of construction slurries in the laboratory and
which was withdrawnApril 2018 and reinstated in May 2019. DOI: 10.1520/D6910
in the field. The Marsh Funnel Viscosity is not a true viscosity,
_D6910M-09.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available from American Petroleum Institute (API), 1220 L. St., NW,
the ASTM website. Washington, DC 20005-4070, http://www.api.org.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.