Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders

This European Standard specifies the requirements, test methods and performance criteria for fire alarm sounders, including voice sounders, in a fixed installation intended to signal an audible warning between the fire detection and fire alarm systems and the occupants of a building (see EN 54-1:2011).
This European standard provides for the assessment and verification of constancy of performance (AVCP) of fire alarm sounders to this EN.
This European standard is not intended to cover:
a)   loudspeaker type devices primarily intended for emitting emergency voice messages that are generated from an external audio source;
b)   supervisory sounders, for example, within the control and indicating equipment.

Brandmeldeanlagen - Teil 3: Feueralarmeinrichtungen Akustische Signalgeber

Diese Europäische Norm legt die Anforderungen, Prüfverfahren und Leistungskriterien für akustische Signalgeber, einschließlich Sprachsignalgeber, fest, die in einer ortsfesten Installation für die Abgabe einer akustischen Warnung von einer Brandmeldeanlage an die Personen im Gebäude vorgesehenen sind (siehe EN 54 1:2011).
Diese Europäische Norm sieht die Bewertung und Überprüfung der Leistungsbeständigkeit (AVCP) von akustischen Signalgebern nach dieser EN vor.
Diese Europäische Norm ist nicht dafür vorgesehen, Folgendes abzudecken:
a)   Lautsprechereinrichtungen, die primär für die Aussendung von Alarmdurchsagen vorgesehen sind, die in externen Audioquellen erzeugt werden;
b)   Statustongeber, die z. B. innerhalb von Brandmelderzentralen vorgesehen sind.

Systèmes de détection et d'alarme incendie - Partie 3: Dispositifs sonores d'alarme feu

La présente Norme européenne spécifie les exigences, les méthodes d'essai et les critères de performance pour les dispositifs sonores d'alarme feu, y compris les alarmes vocales, d’une installation fixe, prévue pour diffuser un signal sonore d'alarme incendie depuis le système de détection et d'alarme incendie vers les occupants d'un bâtiment (voir l'EN 54-1:2011).
La présente Norme européenne prévoit l'évaluation et la vérification de la constance des performances (EVCP) des dispositifs sonores d'alarme feu par rapport à la présente EN.
La présente Norme européenne n'est pas prévue pour traiter :
a)   des dispositifs du type à haut-parleurs, dont la fonction première est de diffuser des messages d'urgence générés par une source audio externe ;
b)   des bruiteurs installés, par exemple, dans les équipements de contrôle et de signalisation.

Sistemi za odkrivanje in javljanje požara ter alarmiranje - 3. del: Naprave za alarmiranje - Zvočne naprave

Standard EN 54-3 določa zahteve, preskusne metode in merila delovanja za zvočne naprave za alarmiranje, vključno z glasovnimi napravami, v vgrajenih napravah, namenjenih signaliziranju zvočnega opozorila med sistemi za odkrivanje in javljanje požara ter alarmiranje ter uporabniki stavbe (glej standard EN 54-1:2011). Ta evropski standard zagotavlja ocenjevanje in preverjanje nespremenljivosti lastnosti (AVCP) zvočnih naprav za alarmiranje za ta standard. Ta evropski standard ni namenjen obravnavanju: a) naprav, podobnih zvočnikom, namenjenih zlasti oddajanju glasovnih sporočil v sili, ki jih proizvaja zunanji zvočni vir; b) nadzornih zvočnih naprav, ki se na primer nahajajo v nadzorni in indikatorski opremi.

General Information

Status
Withdrawn
Publication Date
22-Jul-2014
Withdrawal Date
26-Mar-2019
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
27-Mar-2019

Relations

Buy Standard

Standard
EN 54-3:2014
English language
72 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2014
1DGRPHãþD
SIST EN 54-3:2001
SIST EN 54-3:2001/A1:2002
SIST EN 54-3:2001/A2:2006
6LVWHPL]DRGNULYDQMHLQMDYOMDQMHSRåDUDWHUDODUPLUDQMHGHO1DSUDYH]D
DODUPLUDQMH=YRþQHQDSUDYH
Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders
Brandmeldeanlagen - Teil 3: Feueralarmeinrichtungen Akustische Signalgeber
Systèmes de détection et d'alarme incendie - Partie 3: Dispositifs sonores d'alarme feu
Ta slovenski standard je istoveten z: EN 54-3:2014
ICS:
13.220.20 3RåDUQD]DãþLWD Fire protection
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 54-3
NORME EUROPÉENNE
EUROPÄISCHE NORM
July 2014
ICS 13.220.20 Supersedes EN 54-3:2001
English Version
Fire detection and fire alarm systems - Part 3: Fire alarm devices
- Sounders
Systèmes de détection et d'alarme incendie - Partie 3: Brandmeldeanlagen - Teil 3: Feueralarmeinrichtungen
Dispositifs sonores d'alarme feu Akustische Signalgeber
This European Standard was approved by CEN on 8 May 2014.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 54-3:2014 E
worldwide for CEN national Members.

Contents Page
Foreword .5
Introduction .7
1 Scope .8
2 Normative references .8
3 Terms, definitions and abbreviations .9
3.1 Definitions .9
3.2 Abbreviations . 11
4 Requirements . 11
4.1 Compliance . 11
4.2 Operational reliability . 11
4.2.1 Duration of operation . 11
4.2.2 Provision for external conductors . 11
4.2.3 Flammability of materials . 11
4.2.4 Enclosure protection . 12
4.2.5 Access . 12
4.2.6 Manufacturer's adjustment . 12
4.2.7 On-site adjustment of the operation mode . 12
4.2.8 Software controlled sounders . 13
4.3 Performance parameters under fire conditions . 14
4.3.1 Sound pressure level . 14
4.3.2 Frequencies and sound pattern . 14
4.3.3 Synchronisation . 14
4.3.4 Performance of voice sounders . 15
4.3.5 Voice sounders sequence timing . 15
4.4 Durability of performance parameters under fire conditions . 15
4.4.1 Temperature resistance . 15
4.4.2 Humidity resistance . 15
4.4.3 Shock and vibration resistance . 16
4.4.4 Corrosion resistance . 16
4.4.5 Electrical stability . 16
5 Testing, assessment and sampling methods . 16
5.1 General . 16
5.1.1 Atmospheric conditions for tests . 16
5.1.2 Operating conditions for tests . 17
5.1.3 Mounting arrangements . 17
5.1.4 Tolerances . 17
5.1.5 Provision for tests . 17
5.1.6 Test schedule . 18
5.1.7 Reproducibility . 19
5.2 Operational reliability . 20
5.2.1 Duration of operation . 20
5.2.2 Provision for external conductors . 20
5.2.3 Flammability of materials . 20
5.2.4 Enclosure protection . 21
5.2.5 Access . 22
5.2.6 Manufacturer’s adjustments . 22
5.2.7 On site adjustments of the operating mode . 22
5.2.8 Requirements for software controlled devices . 22
5.3 Performance parameters under fire conditions . 22
5.3.1 Sound pressure level . 22
5.3.2 Frequencies and sound patterns . 23
5.3.3 Synchronisation . 23
5.3.4 Performance of voice sounders . 24
5.3.5 Voice sounder sequence timing . 25
5.4 Durability of performance parameters under fire conditions . 26
5.4.1 Heat resistance . 26
5.4.2 Humidity resistance . 29
5.4.3 Shock and vibration resistance . 31
5.4.4 Corrosion resistance, SO corrosion (endurance) . 35
5.4.5 Electrical stability . 36
6 Assessment and verification of constancy of performance (AVCP) . 37
6.1 General . 37
6.2 Type testing . 37
6.2.1 General . 37
6.2.2 Test samples, testing and compliance criteria . 38
6.2.3 Test reports . 38
6.3 Factory production control (FPC) . 38
6.3.1 General . 38
6.3.2 Requirements . 39
6.3.3 Product specific requirements . 41
6.3.4 Initial inspection of factory and FPC . 42
6.3.5 Continuous surveillance of FPC . 42
6.3.6 Procedure for modifications. 43
6.3.7 One-off products, pre-production products, (e.g. prototypes) and products produced in

very low quantities . 43
7 Classification and designation . 44
8 Marking, labelling and packaging . 44
Annex A (normative) Sound pressure level for fire alarm sounders . 45
A.1 General . 45
A.2 Mounting arrangements . 45
A.3 Instrumentation .
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.