Plastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 2: Specifications for pipes and fittings with smooth internal and external surface and the system, Type A

This part of EN 13476, together with EN 13476 1, specifies the definitions and requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems that are intended to be used for non-pressure underground drainage and sewerage systems.
This part is applicable to pipes and fittings with smooth internal and external surfaces, designated as Type A.
It specifies test methods and test parameters as well as requirements.
This part is applicable to:
a)   structured-wall pipes and fittings, which are intended to be used buried underground outside the building structure; reflected in the marking of products by "U";
b)   structured-wall pipes and fittings, which are intended to be used buried underground both outside (application area code "U") and within the building structure (application area code "D"); reflected in the marking of products by "UD".
This part is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints.
This part covers a range of pipe and fitting sizes, materials, pipe constructions, stiffness classes, application classes, and tolerance classes and gives recommendations concerning colours.
NOTE   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.

Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -leitungen - Rohrleitungssysteme mit profilierter Wandung aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) - Teil 2: Anforderungen an Rohre und Formstücke mit glatter Innen- und Außenfläche und an das Rohrleitungssystem, Typ A

Dieser Teil von prEN 13476 legt gemeinsam mit prEN 13476-1 die Definitionen und Anforderungen für Rohre, Formstücke und das Rohrleitungssystem aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) mit profilierter Wandung fest, die für erdverlegte, drucklos betriebene Abwasserkanäle und -leitungen verwendet werden.
Dieser Teil gilt für Rohre und Formstücke mit glatten Innen- und Außenflächen, bezeichnet als Typ A.
Es werden sowohl Prüfverfahren und Prüfparameter als auch Anforderungen festgelegt.
Dieser Teil gilt für:
a)   Rohre und Formstücke mit profilierter Wandung, die ausschließlich für erdverlegte Anwendungen außer¬halb einer Gebäudestruktur vorgesehen sind; gekennzeichnet mit Anwendungs¬kennzeichen "U";
b)   Rohre und Formstücke mit profilierter Wandung, die sowohl für erdverlegte Anwendungen außerhalb der Gebäudestruktur (Anwendungskennzeichen "U") als auch innerhalb einer Gebäudestruktur (Anwen¬dungs¬kennzeichen "D") vorgesehen sind; gekennzeichnet mit Anwendungs¬kennzeichen "UD".
Dieser Teil gilt für Rohre und Formstücke mit profilierter Wandung sowohl mit glatten Enden als auch mit geformter Muffe, die mittels elastomerer Dichtringverbindungen bzw. durch Heizelement-Stumpf-, Extrusions- oder Heizwendelschweißen miteinander verbunden sind.
Diese Norm enthält Festlegungen für Maße von Rohren und Formstücken, für Werkstoffe, Rohrkonstruktionen, für Steifigkeitsklassen, Anwendungs- und Toleranzklassen und gibt Empfehlungen für die Einfärbung.
ANMERKUNG   Der Anwender bzw. Auftraggeber ist unter Berücksichtigung der eigenen Anforderungen sowie der geltenden nationalen Festlegungen und Verlegepraktiken oder -vorschriften für die entsprechende Auswahl dieser Kriterien verantwortlich.

Systèmes de canalisations en plastique pour les branchements et les collecteurs d'assainissements sans pression enterrés - Systèmes de canalisations à parois structurées en poly(chlorure de vinyle) non plastifié (PVC-U), polypropylène (PP) et polyéthylène (PE) - Partie 2: Spécifications pour les tubes et raccords avec une surface interne et externe lisses et le système, de Type A

La présente partie de l’EN 13476, conjointement avec l’EN 13476 1, spécifie les définitions et les exigences pour les tubes, les raccords et le système pour des systèmes de canalisations à parois structurées fabriqués à partir de poly(chlorure de vinyle) non plastifié (PVC U), polypropylène (PP) et polyéthylène (PE), destinés à être utilisés pour des systèmes de branchements et de collecteurs d'assainissement enterrés sans pression.
La présente partie s'applique aux tubes et raccords avec une surface interne et externe lisses, désignés de Type A.
Elle spécifie les méthodes d'essai et les paramètres d'essai ainsi que les exigences.
La présente partie s'applique aux :
a)   tubes et raccords à parois structurées, destinés à être utilisés enterrés à l'extérieur de la structure du bâtiment ; ce qui est reflété au niveau du marquage des produits par « U » ;
b)   tubes et raccords à parois structurées, destinés à être utilisés enterrés, aussi bien à l'extérieur (code de la zone d’application « U ») qu’à l'intérieur de la structure des bâtiments (code de la zone d’application « D ») ; ce qui est reflété au niveau du marquage des produits par « UD ».
La présente partie s'applique aux tubes et raccords à parois structurées avec ou sans emboîture intégrée qui comprennent des assemblages à bague d'étanchéité en élastomère ainsi que des assemblages soudés et les assemblages obtenus par fusion.
La présente partie couvre une gamme de dimensions de tubes et de raccords, de matières, de constructions de tube, de classes de rigidité, de classes d'application et de classes de tolérance et donne des recommandations concernant les couleurs.
NOTE   Il est de la responsabilité de l'acheteur ou du concepteur du réseau de faire les sélections appropriées à partir de ces aspects, en tenant compte des exigences particulières et des règles nationales et des pratiques ou codes de pose pertinents.

Cevni sistemi iz polimernih materialov za odvodnjavanje in kanalizacijo, ki delujejo po težnostnem principu in so položeni v zemljo - Cevni sistemi s strukturirano steno iz nemehčanega polivinilklorida (PVC-U), polipropilena (PP) in polietilena (PE) - 2. del: Specifikacije za cevi in fitinge z gladko notranjo in zunanjo površino in sistem, tip A

Ta del standarda EN 13476 skupaj s standardom EN 13476-1 določa definicije in zahteve za cevi, fitinge in sistem, ki temelji na nemehčanih cevnih sistemih iz polivinilklorida (PVC-U), polipropilena (PP) ter polietilena (PE) v strukturiranih stenah, ki so namenjeni za uporabo v sistemih za odvodnjavanje in kanalizacijo ter delujejo brez tlaka.
Ta del se uporablja za cevi in fitinge z gladkimi notranjimi in zunanjimi površinami, označene kot tip A.
Določa preskusne metode in preskusne parametre ter zahteve.
Ta del se uporablja za:
a) cevi in fitinge v strukturiranih stenah, ki so namenjeni za uporabo tako, da bodo zakopani v tla zunaj zgradbe; na proizvodu je oznaka »U«;
b) cevi in fitinge v strukturiranih stenah, ki so namenjeni za uporabo tako, da bodo zakopani v tla tako zunaj (koda območja uporabe »U«) kot znotraj zgradbe (koda območja uporabe »D«); na proizvodu je oznaka »UD«.
Ta del se uporablja za cevi in fitinge v strukturiranih stenah z oglavkom ali brez njega s spoji elastomernih tesnilnih obročev ter varjenimi in fuzijskimi spoji.
Ta del zajema razpon velikosti cevi in fitingov, materiale, cevne konstrukcije, razrede togosti, načina uporabe in tolerance ter ponuja priporočila v zvezi z barvami.
OPOMBA: Za ustrezno izbiro teh vidikov je odgovoren kupec ali projektant, pri čemer mora upoštevati posebne zahteve ter vse pomembne nacionalne predpise in prakse ali kodekse vgradnje.

General Information

Status
Withdrawn
Publication Date
03-Apr-2018
Withdrawal Date
02-Jun-2020
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
03-Jun-2020

Relations

Buy Standard

Standard
EN 13476-2:2018
English language
54 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -leitungen - Rohrleitungssysteme mit profilierter Wandung aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) - Teil 2: Anforderungen an Rohre und Formstücke mit glatter Innen- und Außenfläche und an das Rohrleitungssystem, Typ APlastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 2: Specifications for pipes and fittings with smooth internal and external surface and the system, Type A01-junij-2018SIST EN 13476-2:2018SLOVENSKI
STANDARDSIST EN 13476-2:20071DGRPHãþD

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Systèmes de canalisations en plastique pour les branchements et les collecteurs d'assainissement sans pression enterrés - Systèmes de canalisations à parois structurées en poly(chlorure de vinyle) non plastifié (PVC-U), polypropylène (PP) et polyéthylène (PE) - Partie 2: Spécifications pour les tubes et raccords avec une surface interne et externe lisse et le système, de Type A93.030Zunanji sistemi za odpadno vodoExternal sewage systems23.040.05Cevovodi
za zunanje sisteme za odpadno vodo in njihovi deliPipeline and its parts for external sewage systemsICS:SIST EN 13476-2:2018en,fr,deTa slovenski standard je istoveten z:EN 13476-2:2018SIST EN 13476-2:2018

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13476-2
April
t r s z ICS
t uä r v rä r sâ
{ uä r u r Supersedes EN
s u v y xæ tã t r r yEnglish Version
Plastics piping systems for nonæpressure underground drainage and sewerage æ Structuredæwall piping systems of pipes and fittings with smooth internal and external surface and the systemá Type A Systèmes de canalisations en plastique pour les branchements et les collecteurs d 5assainissements sans pression enterrés æ Systèmes de canalisations à parois Partie
tã Spécifications pour les tubes et raccords avec une surface interne et externe lisses et le systèmeá de Type A
KunststoffæRohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und æleitungen æ Rohrleitungssysteme mit profilierter Wandung aus Anforderungen an Rohre und Formstücke mit glatter Innenæ und Außenfläche und an das Rohrleitungssystemá Typ A This European Standard was approved by CEN on
z February
t r s zä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Rue de la Science 23,
B-1040 Brussels
t r s z CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s u v y xæ tã t r s z ESIST EN 13476-2:2018

Compound / formulation PVC-U material . 37 Annex B (normative)
Utilization of non-virgin PVC-U material . 38 B.1 Own reprocessed and recycled material from pipes and fittings . 38 SIST EN 13476-2:2018

Compound / formulation PP material . 40 Annex D (normative)
Utilization of non-virgin PP material . 41 D.1 Own reprocessed material from pipes and fittings . 41 D.2 External reprocessed and recycled materials with an agreed specification . 41 Annex E (normative)
Compound / formulation for PE material . 43 Annex F (normative)
Utilization of non-virgin PE material . 44 F.1 Own reprocessed material from pipes and fittings . 44 F.2 External reprocessed and recycled materials with an agreed specification . 44 F.3 External reprocessed and recycled material from PE rotational-moulded fittings and other components . 44 Annex G (normative)
Impact test at 23 °C . 46 Annex
°C . 47 Annex I (normative)
Ring flexibility test at 20 % diametric deflection . 48 Annex J (informative)
Survey of possible use of reprocessed and recycled material . 49 Annex K (normative)
Impact test for large diameter pipes with structured wall . 50 K.1 Principle . 50 K.2 Apparatus . 50 K.3 Test samples . 51 K.4 Conditioning . 51 K.5 Procedure . 51 K.6 Test result . 52 Bibliography . 53
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.