Structural timber - Structural timber preservative treated against biological attack

This European Standard specifies general requirements for structural timber that has been treated with preservatives against biological attack.
This European Standard also specifies requirements for the evaluation of conformity and marking of preservative treated timber products when they are placed on the market.
Treatments, which include a biocide, are covered by this standard.
It does not provide details of which preservative treatments are necessary for a particular type of structural timber product to achieve a required service life, as regional climatic differences and prevalent biological agents would need to be taken into account for that purpose.
This European Standard does not cover any subsequent treatment which may be required for structural timber products which have been machined, bored or planed after the CE marking has been applied.
This standard does not cover the qualification of preservation products used to treat structural timber.

Bauholz - Bauholz für tragende Zwecke mit Schutzmittelbehandlung gegen biologischen Befall

Diese Europäische Norm legt allgemeine Anforderungen an Bauholz für tragende Zwecke, das mit Holzschutzmitteln
gegen biologischen Befall behandelt wurde, fest.
Ferner legt diese Europäische Norm Anforderungen an die Konformitätsbewertung und Kennzeichnung von
Holzprodukten fest, die mit Holzschutzmitteln gegen biologischen Befall behandelt wurden, und auf den Markt
gebracht werden sollen.
Diese Norm behandelt Schutzmittelbehandlungen.
Sie enthält keine Einzelheiten, welche Schutzmittelbehandlungen für eine besondere Art von Bauholzprodukten
zum Erzielen einer festgelegten Nutzungsdauer erforderlich sind, da dazu die unterschiedlichen
regionalen klimatischen Bedingungen und die jeweils vorherrschenden Schädlinge berücksichtigt werden
müssten.
Diese Europäische Norm behandelt nicht Nachbehandlungen, die für Bauholzprodukte erforderlich sein
können, wenn diese bearbeitet, mit Bohrungen versehen oder gehobelt wurden, nachdem die CE-Kennzeichnung
aufgebracht wurde.
Diese Norm gilt nicht für die Qualifizierung der für die Bauholzprodukte angewendeten Holzschutzmittel.

Bois de structure - Bois de structure traité avec un produit de préservation contre les attaques biologiques

La présente norme européenne spécifie les exigences générales relatives au bois de structure qui a été traité
par des produits de préservation contre les attaques biologiques.
La présente norme européenne spécifie également les exigences relatives à la conformité et au marquage
des produits en bois traités avec un produit de préservation, lorsque ceux-ci sont placés sur le marché.
Les traitements incluant un produit biocide sont couverts par la présente norme.
Elle ne donne pas de détails sur quels traitements de préservation sont nécessaires pour une type particulier
de produit de structure en bois pour atteindre une durée de vie en service prescrite, dans la mesure où les
différences climatiques régionales et les agents biologiques dominants doivent être pris en compte pour
atteindre cet objectif.
La présente norme européenne ne couvre pas les traitements complémentaires pouvant être requis pour des
produits de structure en bois ayant été usinés, mortaisés ou rabotés après application du marquage CE .
La présente norme européenne ne couvre pas la qualification des produits de traitement utilisés pour traiter le
bois de structure.

Konstrukcijski les - Konstrukcijski les, zaščiten pred biološkimi vplivi

General Information

Status
Published
Publication Date
24-Mar-2009
Withdrawal Date
29-Sep-2009
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
05-May-2020

Buy Standard

Standard
EN 15228:2009
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Bauholz - Bauholz für tragende Zwecke mit Schutzmittelbehandlung gegen biologischen BefallBois de structure - Bois de structure traité avec un produit de préservation contre les attaques biologiquesStructural timber - Structural timber preservative treated against biological attack79.040Les, hlodovina in žagan lesWood, sawlogs and sawn timberICS:Ta slovenski standard je istoveten z:EN 15228:2009SIST EN 15228:2009en,fr,de01-julij-2009SIST EN 15228:2009SLOVENSKI
STANDARD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 15228March 2009ICS 71.100.50; 79.040 English VersionStructural timber - Structural timber preservative treated againstbiological attackBois de structure - Bois de structure traité avec un produitde préservation contre les attaques biologiquesBauholz - Bauholz für tragende Zwecke mitSchutzmittelbehandlung gegen biologischen BefallThis European Standard was approved by CEN on 7 February 2009.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre:
Avenue Marnix 17,
B-1000 Brussels© 2009 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15228:2009: ESIST EN 15228:2009

Preservative treatment not affecting
strength and stiffness properties of treated timber . 11 A.1 General . 11 A.2 Preservatives types . 11 Bibliography . 12
− for testing, the whole area of both wings in the SBI apparatus shall be covered with timber pieces with a minimum thickness of 22 mm, mounted edge to edge (butt jointed), without jointing or bonding and orientated horizontally or vertically; − the pieces shall be supported by timber battens, minimum 30 mm by 30 mm, fixed to the test backing boards at 400 mm to 600 mm centres horizontally or vertically (perpendicular to the orientation of the timber pieces). The results for products tested with a given preservative type and retention value in the analytical zone, shall be applicable for the same preservative type applied at a lower retention, and to timber thicknesses and densities greater than those tested. 4.5 Strength and stiffness properties Strength and stiffness shall be assumed not to be affected in the following cases:  treatments and preservatives listed in Annex A, or  treatments with a penetration class not exceeding class NP2 according to EN 351-1. In any other case (e.g. permeable species and deep treatments with class NP 3 and above and with non organic products) since the treatment might affect the strength and stiffness properties, an evaluation shall be performed according to the following principles:  Two matched samples of 50 commercial size pieces each shall be taken. Matching shall be based on the modulus of elasticity (MOE);
...