Grouts for tiles - Part 5: Determination of water absorption

This European Standard applies to all ceramic tile grouts for internal and external tile installations on walls and floors.
This standard specifies the test method to be used to determine the water absorption coefficient due to capillary action when the grout surface contacts the water without any additional pressure. The coefficient is measured by means of prisms.
This European Standard does not contain performance requirements or recommendations for the design and installation of ceramic tiles.
NOTE   Ceramic tile grouts can also be used for other types of tiles (natural and agglomerated stones, etc.), where these do not adversely affect the stones.

Klebstoffe und Fugenmörtel für Fliesen und Platten - Teil 5: Bestimmung der Wasseraufnahme

Diese Europäische Norm ist auf sämtliche Klebstoffe und Fugenmörtel für keramische Fliesen und Platten an Wand und Boden für innen und außen anwendbar.
Diese Europäische Norm legt das Prüfverfahren zur Bestimmung des Wasseraufnahmekoeffizienten durch Kapillarwirkung ohne zusätzlichen Druck, wenn die Oberfläche des Fugenmörtels mit Wasser in Berührung kommt, fest. Der Koeffizient wird mit Prismen bestimmt.
Diese Europäische Norm enthält keine Anforderungen an und Empfehlungen für die Planung und Verlegung von keramischen Fliesen und Platten.
ANMERKUNG   Fugenmörtel für keramische Fliesen und Platten können auch für andere Materialarten verwendet werden (Natur-, Betonwerksteine usw.), sofern diese die Steine nicht negativ beeinflussen.

Mortiers de joints pour carrelages - Partie 5: Détermination de l'absorption d'eau

La présente Norme européenne s'applique à tous les mortiers utilisés pour le jointoiement de carrelages céramiques sur les murs et au sol, à l'intérieur et à l'extérieur.
La présente norme spécifie la méthode d'essai qui doit être utilisée pour déterminer l'absorption d'eau par capillarité lorsque la surface du mortier est en contact avec de l'eau sans pression particulière. Cette mesure est réalisée sur des éprouvettes prismatiques.
La présente Norme européenne ne contient pas de spécifications, ni de recommandations pour la conception et la pose des carrelages en céramique.
NOTE   Les mortiers de joints peuvent être également utilisés pour d'autres types de carrelage (pierre naturelle ou agglomérée, etc.) s'ils sont compatibles.

Lepila in fugirne malte za ploščice - 5. del: Ugotavljanje vpijanja vode

General Information

Status
Withdrawn
Publication Date
11-Dec-2001
Withdrawal Date
21-Oct-2008
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
22-Oct-2008
Completion Date
22-Oct-2008

Relations

Buy Standard

Standard
EN 12808-5:2002
English language
7 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Klebstoffe und Fugenmörtel für Fliesen und Platten - Teil 5: Bestimmung der WasseraufnahmeMortiers de joints pour carrelages - Partie 5: Détermination de l'absorption d'eauGrouts for tiles - Part 5: Determination of water absorption91.100.23Ceramic tiles91.100.10Cement. Mavec. Apno. MaltaCement. Gypsum. Lime. Mortar83.180LepilaAdhesivesICS:Ta slovenski standard je istoveten z:EN 12808-5:2001SIST EN 12808-5:2002en01-november-2002SIST EN 12808-5:2002SLOVENSKI
STANDARD



SIST EN 12808-5:2002



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 12808-5December 2001ICS 91.100.10English versionGrouts for tiles - Part 5: Determination of water absorptionMortiers de joints pour carrelages - Partie 5: Déterminationde l'absorption d'eauKlebstoffe und Fugenmörtel für Fliesen und Platten - Teil 5:Bestimmung der WasseraufnahmeThis European Standard was approved by CEN on 3 November 2001.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2001 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 12808-5:2001 ESIST EN 12808-5:2002



EN 12808-5:2001 (E)2ContentspageForeword.31Scope.42Normative references.43Sampling.44Test conditions.45Test materials.46Apparatus.47Mixing of grouts.48Preparation of test specimens.59Conditioning.510Test procedure.511Evaluation and expression of results.512Test report.6Bibliography.7SIST EN 12808-5:2002



EN 12808-5:2001 (E)3ForewordThis European Standard has been prepared by Technical Committee CEN /TC 67 "Ceramic tiles", the secretariat ofwhich is held by UNI.This European Standard shall be given the status of a national standard, either by publication of an identical textor by endorsement, at the latest by June 2002, and conflicting national standards shall be withdrawn at the latestby June 2002.According to the CEN/CENELEC Internal Regulations, the national standards organizations of the followingcountries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland,France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden,Switzerland and the United Kingdom.SIST EN 12808-5:2002



EN 12808-5:2001 (E)41 ScopeThis European Standard applies to all ceramic tile grouts for internal and external tile installations on walls andfloors.This standard specifies the test method to be used to determine the water absorption coefficient due to capillaryac
...